header advert
Results 1 - 9 of 9
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 55 - 55
1 Apr 2018
Pierrepont J Miller A Bruce W Bare J McMahon S Shimmin A
Full Access

Introduction

Appropriate prosthetic alignment is an important factor in maintaining stability and maximising the performance of the bearing after total hip replacement (THR). With a cementless component, the anteversion of the native femur has been shown to influence the anteversion of the prosthetic stem. However, the extent to which anteversion of a cementless stem can be adjusted from the native anteversion has seldom been reported. The aim of this study was to investigate the difference between native and stem anteversion with two different cementless stem designs.

Method

116 patients had 3-dimensional templating as part of their routine planning for THR (Optimized Ortho, Sydney). 96 patients from 3 surgeons (AS, JB, SM) received a blade stem (TriFit TS, Corin, UK) through a posterior approach. 18 patients received a fully HA-coated stem (MetaFix, Corin, UK) through a posterior approach by a single surgeon (WB). The anteversion of the native femoral neck was measured from a 3D reconstruction of the proximal femur. All patients received a post-operative CT scan which was superimposed onto the pre-op CT scan. The difference between native and achieved stem anteversion was then measured. As surgeons had differing philosophies around target stem anteversion, the differences amongst surgeons were also investigated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 53 - 53
1 Apr 2018
Pierrepont J Stambouzou C Bruce W Bare J Boyle R McMahon S Shimmin A
Full Access

Introduction & aims

Correct prosthetic alignment is important to the longevity and function of a total hip replacement (THR). With the growth of 3-dimensional imaging for planning and assessment of THR, the importance of restoring, not just leg length and medial offset, but anterior offset has been raised. The change in anterior offset will be influenced by femoral anteversion, but there are also other factors that will affect the overall change after THR. Consequently, the aim of this study was to investigate the relationship between anterior offset and stem anteversion to determine the extent to which changing anteversion influences anterior offset.

Method

Sixty patients received a preoperative CT scan as part of their routine planning for THR (Optimized Ortho, Sydney). All patients received a Trinity cementless shell and a cemented TaperFit stem (Corin, UK) by the senior author through an anterolateral approach. Stem anteversion was positioned intraoperatively to align with cup anteversion via a modified Ranawat test. Postoperatively, patients received a CT scan which was superimposed onto the pre-op CT scan. The difference between native and achieved stem anteversion was measured, along with the 3-dimensional change in head centre from pre-to post-op. Finally, the relationship between change in stem anteversion and change in anterior offset was investigated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 61 - 61
1 Dec 2017
Davies G Bradford N Oliver R Verheul R Bruce W Walsh W
Full Access

Aim

The prevention of surgical-site infection (SSI) is of great importance. Airborne particulate correlates with microbial load and SSI. There are many potential sources of airborne particulates in theatre and from an experimental point of view impossible to control. We evaluated the effectiveness of a novel air decontamination-recirculation system (ADRS) in reducing airborne particles in a laboratory environment and controlled the introduction of particulate using diathermy.

Methods

Airborne particles were measured with and without activation of the ADRS in PC2 laboratory to provide a baseline. Particles were generated in a controlled manner utilising electrocautery ablation of porcine skin tissue. Ablation was performed at 50W power (Cut) for 60 seconds at a constant rate with and without the ADRS operating in the PC2 laboratory. Particles were measured continuously in 30s intervals at two sites 0.5m and 3m from the site of diathermy. Adequate time was allowed for return to baseline between each repetition. Each experiment was repeated 10 times.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 24 - 24
1 Mar 2013
Brinkman J Bubra P Walker P Walsh W Bruce W
Full Access

In order to emulate normal knee kinematics more closely and thereby potentially improve wear characteristics and implant longevity the Medial Pivot type knee replacement geometry was designed. In the current study the clinical and radiographic results of 50 consecutive knee replacements using a Medial Pivot type knee replacement are reported; results are compared to the Australian Orthopaedic Associations National Joint Replacement Registry. The patients' data were crossed checked against the registry to see if they had been revised elsewhere. After a mean follow-up of 9.96 years results show that the Medial Pivot Knee replacement provides good pain relief and functional improvement according to KSS and Womac scores and on subjective patient questionnaires. There was one minor revision; insertion of a patella button at 6.64 years FU. There were no major revisions; all implants appeared to be well fixed on standard radiographic examination. While the revision rate for the Medial Pivot knee according to the Australia Joint Registry results is higher compared to all other types of knee replacements in the registry, and to what is reported in the literature on the medial pivot knee, it is not in the current series. Revision rate was similar to what is reported on in the literature, but after a longer follow-up period. However, long term follow-up is required to draw definitive conclusions on the longevity of this type of implant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 316 - 316
1 Mar 2013
Russell N Rives A Bruce W Pelletier M Walsh W
Full Access

Introduction

Gamma Irradiation is often considered the gold standard for sterilizing bone allograft. However, a dose dependant decrease in the static mechanical properties of gamma irradiated bone has been well established. Supercritical Fluid Sterilization (SCF) using carbon dioxide represents a potential alternate method to sterilize allografts. This study aimed to evaluate the effect of SCF on the static and dynamic (fatigue) properties of cortical bone in 3-point bending.

Methods

Eighty paired 18-month old rabbit humeri were randomized to 4 treatments: Gamma Irradiation at 10 kGy or 25 kGy, SCF Control and SCF with Peracetic Acid (Figure 1) (n=20 pairs per group). One side was treated while the other acted as a control. Ten pairs in each group were tested statically at 5 mm/min; while ten were tested dynamically between 15–150 N at 4 Hz. Samples were fatigued to failure or 50000 cycles (run-out). All testing was performed at room temperature in a saline bath. A 2-tailed t-test was used to test for significance within pairs and a one-way ANOVA with Games-Howell post-hoc test was used to test between groups.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 207 - 207
1 Mar 2013
Johns B Pelletier M Bertollo N Hancock N Walsh W Bruce W
Full Access

Introduction

Initial stability of the tibial component influences the success of uncemented total knee arthroplasty. In uncemented components, osseointegration provides long-term fixation which is particularly important for the tibial component. Osseointegration is facilitated by minimising bone-implant interface micromotion to within acceptable limits. To investigate initial stability, this study compares the micromotion and initial seating of two uncemented hydroxyapatite-coated tibial components, the Genesis II and Profix. This is the first stability comparison of two hydroxyapatite-coated tibial components.

Methods

Six components of each type were implanted into synthetic tibias by a single orthopaedic surgeon. Good coverage was achieved. No screws or articular inserts were used. Initial seating was measured using ImageJ software at five areas on each tibia. Tibias were transected and their proximal section implanted into a molten alloy parallel to horizontal. Dynamic mechanical testing was performed using a hydraulic 858-Bionix machine. Prostheses underwent unilateral axial point-loading of 700N cyclically applied four times. The load was applied to three locations approximating femoral loading points. The loading cycle was repeated six times at each point, allowing micromotion to be recorded at three contralateral locations. Micromotion was measured by optical lasers. After dynamic testing, two tibial components of each type were removed with claw pliers while measuring the force required on the 858-Bionix machine. Implant under-surfaces were photographed for wear.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 294 - 294
1 Mar 2013
Oliver R Brinkman M Christou C Bruce W Walsh W
Full Access

Introduction

The reduction of intraoperative blood loss during total knee arthroplasty (TKA) and total hip arthroplasty (THA) and even organ resection is an important factor for surgeons as well as the patient. In order to cauterize blood vessels to stop bleeding diathermy is commonly used and involves the use of high frequency and induces localized tissue damage and burning. Saline-coupled bipolar sealing RFE technology however has been shown to reduce tissue carbonization, however the dosage effects of RFE are not well known for both bone and soft tissue. This study examined sealing progression of blood vessels using a range of energy levels of saline-coupled bipolar RFE on bone and various soft tissues in a non-survival animal study.

Materials and Methods

Following institutional ethical approval, three mature sheep were used to examine the cancellous bone of the femoral trochlear groove and soft tissue (liver, kidney, lung, pancreas and mesentry peritoneum) subjected to the following treatment regime varying by watts and time: (1) untreated control, (2) 50 W for 1 sec, 2 sec, 3 sec and 5 sec, (3) 140 W for 1 sec, 2 sec, 3 sec and 5 sec and (4) 170 W for 1 sec, 2 sec, 3 sec and 5 sec. The Aquamantys™ System Generator and hand piece (Salient Surgical Technologies, Inc, Portsmouth, NH) coupled to a saline (0.9% NaCl) drip was used to apply RFE to the various tissues. Two clinical diathermy settings were used as controls. Tissues were immediately harvested, fixed in 10% buffered formalin and prepared for routine paraffin histology. Stained sections were evaluated in a blinded fashion for the acute in vivo response.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 126 - 126
1 May 2012
Russell N Rives A Pelletier M Hoffman M Bruce W Walsh W
Full Access

Cortical bone is a complex composite material composed of an inorganic mineral phase and organic matrix of type I collagen and various non-collagenous proteins. The hierarchical organisation of bone results in a transversely isotropic material with the mechanical properties in the long-axis (z) being superior to the radial and circumferential axes which are equivalent. This directional dependence of bone has been well reported, whilst the mechanisms/anisotropy are more difficult to study. This study examined the anistropic nature of cortical bone and the influence of different sterilisation procedures.

Ninety cortical bone cubes were prepared using established techniques (Walsh and Guzelsu) and randomly allocated to three treatments; control, 15 KGy, Super Critical Fluid (SCF) (n=30 per group). The ultrasonic moduli was examined using longitudinal sound waves at 5 MHz using a pulse receive technique. Unconfined compression was performed non-destructively in longitudinal (z), circumferential (ï±) and radial orientations (r). Samples were tested to failure in the z axis. A two-way analysis of variance (treatment and time) followed by a Games Howell post hoc test and covariate analysis was performed using SPSS for Windows.

Data from this study revealed some interesting and intriguing results with respect to the effects of gamma irradiation and dense gas technology on the properties of cortical bone and load transmission. A statistical decrease in the compressive stiffness and strength was noted with 15 KGy of whilst SCF treatment did not alter the properties in the r or ï orientations. Similar results were found with respect to the ultrasonic moduli (data not shown). The pilot data confirmed the adverse effects of bone in compression following gamma irradiation as we found in our recently presented ORS work. However, the study in compression demonstrated that the directional dependence that makes cortical bone a transversely isotropic material is removed following gamma irradiation with SCF did not appear to have this effect.

The effects of gamma irradiation on the mechanical performance of allografts in the long bone axis may play a role in their in vivo performance. The removal of the anisotropy following gamma irradiation provides insight into the relationship(s) between the mineral and organic constituents, which requires further study.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 112 - 112
1 Mar 2012
Biant L Bruce W Walker P Herrmann S Walsh W
Full Access

‘High flexion’ polyethylene tibial tray inserts are available from total knee replacement (TKR) manufacturers. There is currently no published data available that examines how much extra knee flexion these new implants give or if there are any wear consequences for the change in design. The high flexion inserts are narrower posteriorly than standard inserts and have chamfers anteriorly and on the post in cruciate sacrificing designs.

This prospective randomised controlled trial of 100 patients undergoing posterior stabilised TKR compared knee flexion, measured intra-operatively by a computer navigation system, of the standard and high flexion trial inserts in the same knee. Patients were then randomised to receive either a standard or ‘high flexion’ definitive component and the stability assessed. The post-operative knee flexion of all patients was measured at six months.

High flexion inserts did not give significantly more knee flexion than standard inserts either per-operatively at the trial insert stage, or at six months post-op and resulted in marginally more anterior draw. The average per-operative difference in flexion between standard and high flex inserts measured in the same knee was 3.2° (range -4-18°) The average knee flexion at 6 months post op was 106° for both groups. The average change in knee flexion comparing pre and post op was 2.3° for the high flex group and 0.6° for the standard insert group.

Laboratory Tek scan contact pressure analysis at the surface of the standard and high flexion designs was not significantly different, but the thinner polyethylene of the high flexion design raises questions about wear characteristics. High flexion polyethylene inserts are probably not justified in terms of improved knee flexion, but may be a useful option in certain technical circumstances during TKR such as patella baja or if the patella impinges on the post in deep flexion.