The place of thromboprophylaxis in arthroplasty surgery remains
controversial, with a challenging requirement to balance prevention
of potentially fatal venous thrombo-embolism with minimising wound-related
complications leading to deep infection. We compared the incidence
of fatal pulmonary embolism in patients undergoing elective primary
total hip arthroplasty (THA) between those receiving aspirin, warfarin
and low molecular weight heparin (LMWH) for the chemical component
of a multi-modal thromboprophylaxis regime. A prospective audit database was used to identify patients who
had died within 42 and 90 days of surgery respectively between April
2000 and December 2012. A case note review was performed to ascertain
the causes of death.Aims
Patients and Methods
The available treatments for NSLBP (Non-Specific Low Back Pain) provide, typically, small to moderate average benefits to patients. The aim of this pilot cluster RCT was to test the hypothesis that the use of a patient decision aid together with an informed shared decision making consultation would produce better outcomes in satisfaction with treatment at four month follow-up. We developed a DSP (Decision Support Package). We randomised the physiotherapists and trained those in the intervention arm in informed shared decision making and communication. Participants were recruited from a local physiotherapy department and those allocated to an appointment with an intervention therapist were sent a copy of the DSP in the post. Participants then attended their appointment as usual.Background
Methods
Early detection of Developmental Dysplasia of the Hip (DDH), and treatment, may prevent the need for surgical correction following late presentation. Neonatal examination, and ultrasound screening of at risk groups, does not detect all cases. Most neonates treated in the Intensive Care Unit (NICU) have abdominal radiographs performed during their stay. These include the hips but DDH is not routinely looked for. 50 neonatal abdominal films (five from patients who subsequently were found to have DDH, 45 from patients without this condition) were randomly shown to three paediatric orthopaedic surgeons and three paediatric radiologists on two separate occasions. Each was asked whether they would refer the patient for further investigation. An overall sensitivity of 25.5% (Range 0–60%) and specificity of 93.2% (Range 87–97%) was found with a positive predictive value (PPV) of 14.0% (Range 0–37%) and negative predictive value (NPV)of 96.3% (Range 95–98%). Although the low sensitivity and PPV make interpretation of these films a poor way to diagnose DDH, the high specificity and NPV suggest that they may be used as a prompt to further investigation. Therefore, we propose that DDH should be looked for on these films and, where there is radiological suspicion, ultrasound examination should be advised.
To assess the incidence of fatal pulmonary embolism (PE) following elective total knee replacement (TKR) with a standardised multi-modal prophylaxis regime in a large teaching DGH over a 10 year period. Information was gathered from a prospective audit database, utilising clinical coding for TKR and those that had died within 42 and 90 days. The 10 years from April 2000 were analysed to establish both 42 and 90 day mortality rates. A multi-modal prophylaxis regime for all patients included regional anaesthesia (when possible), mechanical prophylaxis (Flo-tron calf garment per-operatively, AV impulse boots until mobile and anti-embolism stockings for 6 weeks), mobilisation within 24 hours and 75mg aspirin for 4 weeks. A case note review was performed to ascertain the causes of death. Where a patient had been referred to the coroner, the coroner's office was contacted for PM results.Aim
Material and methods
The aim of this prospective randomised study
was to compare the clinical and radiological results of a cemented
all-polyethylene Ultima acetabular component with those of a cementless
porous-coated acetabular component (PFC) following total hip replacement
(THR). A total of 287 patients received either a polyethylene acetabular
component (group A) or a cobalt–chromium porous-coated component
(group B) with an identical cemented femoral component and 28 mm
cobalt-chromium head, thus making it the largest study of its type.
Patients were evaluated radiologically and clinically using the
Harris hip score (HHS). Group A comprised 183 patients (73 male,
110 female) with a mean age of
71.3 years (55 to 89). Group B comprised 104 patients (48 male,
56 female) with a mean age of 69.8 years (56 to 89). A total of
16 patients (13 in Group A, three in Group B) did not have post-operative
data for analysis. The mean follow-up in group A was 7.52 years
(0.4 to 15.0) and in Group B 7.87 years (0.5 to 14.0). At final follow-up the mean HHS was similar between groups A
and B (74.5 (25 to 100) and 78.0 (37 to 100), respectively; p =
0.068). The total number of revisions for any cause was 28, 17 of
which were in group A and 11 in group B. The ten-year survivorship
was 86.8% (95% confidence interval (CI) 78.4 to 92.1) and 89.2%
(95% CI 78.3 to 94.8) for groups A and B, respectively (log-rank
p-value = 0.938). A total of 20 cemented and two cementless acetabular
components had evidence of acetabular radiolucencies or acetabular
component migration at last follow-up (p = 0.001). These results indicate that patients with a cemented all-polyethylene
and cementless porous-coated polyethylene lined acetabular component
have similar long-term clinical outcomes.
286 patients underwent total hip arthroplasty with a cemented titanium femoral implant (Ultima, Johnson & Johnson) between July 1995 and July 2001. The acetabular component was either a porous coated cup or a cemented all-polyethylene cup. A 28mm cobalt chromium head was used in all patients. Patients were prospectively evaluated with clinical examination, Harris hip scores and radiographic assessment. Analysis of the data was performed. Of the 286 patients, 11 patients were excluded from analysis for reasons including incomplete data (8) and death (3). The remaining 275 patients were comprised of 118 males and 157 females with an average age of 70.8 years (55–89 years). The average follow up was 10.5 years (1.03–14.23). The median follow up was 10 years. 177 cemented all-polyethylene and 98 porous coated acetabular cups were used. The average Harris hip scores were 34.4 and 81.25 for preoperative and last follow up visit respectively. 11 stems were revised (aseptic loosening 9, infection 2). Radiographic assessment showed vertical subsidence in 30 patients (10.9%) (>5mm in 6 and < 5mm in 24 patients). Complete cement-bone radiolucency was noted in 11 stems (4%). Radiolucent lines covering < 50% of cement-bone interface were noted in 18 stems (6.5%). There were no cases of cement fracture. Kaplan-Meier survivorship was 91% at 10 years & 89.8% at 12 years.Method
Results
We report a large study of 331 patients at two years post operation who were prospectively randomised to receive either a rotating platform or a fixed bearing knee replacement of an otherwise identical design. The mobile bearing total knee replacement was developed as there are theoretical benefits in that it may allow a better range of motion, better patella tracking and lower wear rates. This study was designed to see if these potential advantages are borne out in practice when using a cruciate retaining design.Summary
Introduction
Previous studies comparing cruciate retaining (CR) and cruciate sacrificing - posterior stabilised (PS) TKRs have failed to demonstrate a difference in outcomes based on numbers of patients recruited. This large study compares clinical outcomes in groups having PS and CR TKR and reports the results at 1 and 2 years post-operatively. A total of 683 patients undergoing TKR were consecutively enrolled in a prospective multi-centre study with 2 arms. In the first arm patients receiving a PS component were randomised to receive either a mobile bearing (176 patients) or fixed bearing (176 patients) implant. In the second arm, patients receiving a CR component were randomised to receive either a mobile bearing (161 patients) or fixed bearing (170 patients) implant. All patients were assessed preoperatively and at one and two years postoperatively using standard tools (Oxford, AKSS, Patellar Score) by independent nurse specialists. The data from the 2 arms of the trial were then analysed to compare differences between PS and CR implants.Introduction
Methods
It is hypothesised that cruciate retention in total knee arthroplasty may result in improved kinematics of the knee by maintaining the femoral rollback seen in the normal knee, resulting in improved function. This study compares clinical outcomes in groups having PS and CR total knee arthroplasty and report the results at 1 and 2 years post-operatively.
Patients with a PS also showed a greater improvement in the AKSS knee score at 1 (p=0.0001) and 2 (p=0.001) years. Knee flexion improvement was also greater in the PS group at 1 (p=0<
0.0001) and 2 (p=0.0035) years. PS knees also achieved better outcomes in these variables in the mobile and fixed subgroups. There were no other significant differences in the scores between the two groups at any stage.
Patients with severe haemophilia have a tendency towards recurrent haemarthroses resulting in chronic synovitis and leading to end stage haemophilic arthropathy. From 1997 to 2001 five patients underwent sequential bilateral total knee replacement. We compared these patients with 13 haemophilic patients undergoing primary unilateral total knee replacement. One senior surgeon performed all surgery using an identical prosthesis under similar surgical and haematological conditions. We reviewed information regarding pre-operative medical condition, antibiotic prophylaxis, blood replacement requirement and tourniquet time were all recorded. The rate of post-operative complications and economic evaluation between the two cohorts was calculated. Functional results were assessed using the Hospital for Special Surgery knee scoring system both pre and postoperatively. We have shown that complication rates following bilateral and unilateral total knee replacements are comparable and that there are no differences in the functional outcomes or complication rates between the two groups. Furthermore, we found that bilateral procedures were advantageous with respect to total rehabilitation times, length of in-patient stay clotting factor usage and cost efficiency.