Prosthetic joint infections (PJIs) generate significant clinical and socio-economic pressures on the health service. Recent advances in the diagnosis of PJIs, with biomarkers and sonification have aided delineation of PJIs from aseptic processes. However these investigations are not widely available and expensive. Interface membrane histology has been shown to be superior to pseudocapsule histology; we therefore sought to ascertain the diagnostic benefit of deep canal sample microbiology in conjunction with standard pseudocapsule sampling. We performed a prospective study over a 20-month period as part of new multi-disciplinary approach to the management of suspected PJIs. 22 patients underwent 26 procedures at our institution where intra-operative deep canal samples were obtained concurrent to conventional pseudocapsule samples. These samples were cultured and analysed following our standardised microbiological methodology.Introduction
Patients/Materials & Methods
Isolated Weber B lateral malleolus fractures heal uneventfully, but concern that late subluxation may occur due to unrecognised medial ligament tearing, despite an intact mortice on initial radiographs, often results in overtreatment. The aim of this study was to determine the incidence of late talar shift with nonoperative management in a cohort of patients with no initial talar shift, and also record functional outcomes at 16–28 months following injury. This was a retrospective review of 129 patients with Weber B lateral malleolar fractures initially referred to the fracture clinic between October 2011 and October 2012. Eight had obvious talar shift and therefore underwent surgery, with the remaining 121 treated in plaster (n=41), a Velcro boot (n=70) or bandage (n=10). No stress x-rays or MRI scans were performed. Weight-bearing was permitted as pain allowed. Radiographs taken on discharge from the clinic were reviewed to assess talar shift. Functional outcomes assessment was carried out using Manchester Oxford Foot Questionnaire and Olerud-Molander score.Introduction:
Methods:
The technique of femoral cement-in-cement revision
is well established, but there are no previous series reporting its
use on the acetabular side at the time of revision total hip replacement.
We describe the technique and report the outcome of 60 consecutive
acetabular cement-in-cement revisions in 59 patients at a mean follow-up
of 8.5 years (5 to 12). All had a radiologically and clinically
well-fixed acetabular cement mantle at the time of revision. During
the follow-up 29 patients died, but no hips were lost to follow-up.
The two most common indications for acetabular revision were recurrent
dislocation (46, 77%) and to complement femoral revision (12, 20%). Of the 60 hips, there were two cases of aseptic loosening of
the acetabular component (3.3%) requiring re-revision. No other
hip was clinically or radiologically loose (96.7%) at the latest
follow-up. One hip was re-revised for infection, four for recurrent
dislocation and one for disarticulation of a constrained component.
At five years the Kaplan-Meier survival rate was 100% for aseptic
loosening and 92.2% (95% CI 84.8 to 99.6), with revision for any cause
as the endpoint. These results support the use of cement-in-cement revision on
the acetabular side in appropriate cases. Theoretical advantages
include preservation of bone stock, reduced operating time, reduced
risk of complications and durable fixation.
There is evidence that recommends the retention of a well-fixed cement mantle at the time of revision hip arthroplasty. The cement-cement interface has been proven to have greater shear strength than a new bone-cement interface after removing a well-fixed cement mantle. This study reviewed a series of acetabular revision procedures with a minimum 2-year follow-up where the original cement mantle was left intact. From 1988 to 2004, 60 consecutive cement-in-cement revisions of the acetabular component were performed at our institution. Outcome was based on functional assessment using the Oxford, Charnley, and Harris scoring systems as well as radiographic analysis using the DeLee and Charnley criteria. In total 60 procedures were performed in 60 patients (40 female and 20 male), whose mean age at surgery was 75 years (range 40 to 99 years). 80% were performed for recurrent dislocation, 13.3% during femoral component revision, 5% for acetabular component wear, and 1.7% for pain. No case was lost to follow-up. There was one re-revision for aseptic cup loosening at 7 years, with 1 further case of radiological loosening identified at the latest review. There were 6 further cases of dislocation 4 of which were treated with further in-cement revisions. All other cases showed well-fixed components on radiographic analysis and no evidence of failure at the most recent follow up. The cement-in-cement technique already has a good body of evidence based on revision of the femoral component and this study shows that the technique can be applied to acetabular revisions as well with good functional and radiological results in the short to medium term.
There is evidence that recommends the retention of a well-fixed cement mantle at the time of revision hip arthroplasty. The cement-cement interface has been proven to have a greater shear strength than a new bone-cement interface after removing the old cement mantle. This study reviewed a series of acetabular revision procedures with a minimum 2 year follow-up where the original cement mantle was left intact. From 1988 to 2004, 61 consecutive cement-in-cement revisions of the acetabular component were performed at our institution. Outcome was based on functional assessment using the Oxford, Charnley, and Harris scoring systems as well as radiographic analysis using the DeLee and Charnley criteria. In total 61 procedures were performed in 59 patients (40 female and 19 male), whose mean age at surgery was 75 years (range 40 to 99 years). 47 hips (77%) were performed for recurrent dislocation, 12 for polyethylene wear associated with other reasons for revision (aseptic stem loosening in 8, stem fracture in 2, femoral periprosthetic fracture in 1, subluxation in 1), 1 for unexplained pain, and 1 for disarticulation (intraprosthetic dislocation) of a constrained liner. No case was lost to follow-up. There was a significant improvement in the functional scores from the pre-operative status with the patients maintaining a low level of pain. There was one re-revision for aseptic cup loosening at 7 years, with 1 further case of radiological loosening identified at the latest review. There were 6 further cases of dislocation 4 of which were treated with further in-cement revisions. All other cases showed well-fixed components on radiographic analysis and no evidence of failure at the most recent follow up. The cement-in-cement revision technique can be used in selected cases of acetabular revision surgery, providing satisfactory functional outcomes backed up by good radiographic results. Blood loss and surgical time are also significantly decreased.