Patients with transfemoral amputation (TFA) often
experience problems related to the use of socket-suspended prostheses.
The clinical development of osseointegrated percutaneous prostheses
for patients with a TFA started in 1990, based on the long-term
successful results of osseointegrated dental implants. Between1999 and 2007, 51 patients with 55 TFAs were consecutively
enrolled in a prospective, single-centre non-randomised study and
followed for two years. The indication for amputation was trauma
in 33 patients (65%) and tumour in 12 (24%). A two-stage surgical
procedure was used to introduce a percutaneous implant to which
an external amputation prosthesis was attached. The assessment of
outcome included the use of two self-report questionnaires, the
Questionnaire for Persons with a Transfemoral Amputation (Q-TFA)
and the Short-Form (SF)-36. The cumulative survival at two years’ follow-up was 92%. The
Q-TFA showed improved prosthetic use, mobility, global situation
and fewer problems (all p <
0.001). The physical function SF-36
scores were also improved (p <
0.001). Superficial infection
was the most frequent complication, occurring 41 times in 28 patients
(rate of infection 54.9%). Most were treated effectively with oral
antibiotics. The implant was removed in four patients because of loosening
(three aseptic, one infection). Osseointegrated percutaneous implants constitute a novel form
of treatment for patients with TFA. The high cumulative survival
rate at two years (92%) combined with enhanced prosthetic use and
mobility, fewer problems and improved quality of life, supports
the ‘revolutionary change’ that patients with TFA have reported
following treatment with osseointegrated percutaneous prostheses. Cite this article:
The first osseointegrated transfemoral amputation prosthesis operation was performed in Gothenburg in 1990. The aim is improving quality of life for patients who cannot use conventional socket prosthesis. In 1999 the prospective OPRA-study (Osseointegrated Prosthesis for Rehabiliation of Amputees) was initiated with standardized surgery, equipment and rehabilitation program. The surgery consists of a two-stage procedure. At the primary surgery (S1), a titanium screw (the fixture) is inserted into the remaining diaphyseal bone. The fixture is 80 mm long with a diameter of 16–20 mm (+0.5 mm increments). The patient is hospitalized 5-7 days. At the secondary surgery (S2), six months later, an abutment is inserted into the fixture. The abutment has a hexagonal press-fitting into the fixture and is secured by an abutment screw. The patient remains hospitalized 10–12 days. Gradual increase of load and activity is initiated over a 6 month period.Aim
Method