Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To

Abstract

Introduction

Medial fix bearing unicompartmental knee replacement (UKR) designs are consider safe and effective implants with many registries data and big cohort series showing excellent survivorship and clinical outcome comparable to that reported for the most expensive and surgically challenging medial UKR mobile bearing designs. However, whether all polyethylene tibial components (all-poly) provided comparable results to metal-backed modular components during medial fix bearing UKR remains unclear. There have been previous suggestions that all-poly tibia UKR implants might show unacceptable higher rates of early failure due to tibial component early loosening especially in high body max index (BMI) patients. This study aims to find out the short and long-term survival rate of all-poly tibia UKR and its relationship with implant thickness and patient demographics including sex, age, ASA and BMI.

Material and Methods

we present the results of a series of 388 medial fixed bearing all-polly tibia UKR done in our institution by a single surgeon between 2007–2019.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 67 - 67
1 Jul 2022
Bhamber N Chaudhary A Middleton S Walmsley K Nelson A Powell R Mandalia V
Full Access

Abstract

Introduction

High posterior tibial slope (PTS) has been recognised as a risk factor for anterior cruciate ligament rupture and graft failure. This prospective randomised study looked at intra-operative findings of concomitant intra-articular meniscal and chondral injuries during a planned ACL reconstruction.

Material and Methods

Prospective data was collected as part of a randomised trial for ACL reconstruction techniques. Intra-operative data was collected and these findings were compared with the PTS measured on plain radiograph by a single person twice through a standardised technique and intra-observer analysis was performed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 24 - 24
1 Jul 2022
Spolton-Dean C Burden E East J Toms A Bhamber N Waterson B
Full Access

Abstract

Introduction

OtisMed Shape Match ® patient specific implant cutting jigs were designed to place TKA in kinematic alignment (KA) rather than traditional mechanical alignment (MA). This product was withdrawn from the market in 2013.

It has been hypothesised that KA might lead to early implant failure. Initial evidence has not supported this.

We present 10 year outcome data for the largest single centre cohort to date.

Methodology

Between 2010 and 2013, 127 Shape Match® TKAs were implanted in 119 individuals.

Retrospective review of long leg post-operative radiographs assessed femoral mechanical anatomical angle (FMA), tibial mechanical angle (TMA), hip-knee-ankle angle (HKA), posterior tibial slope (PTS) and femoral component flexion.

Oxford Knee Scores (OKS), revision and further surgery rates were reviewed.