Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 28 - 28
19 Aug 2024
Bell L Stephan A Pfirrmann CWA Stadelmann V Schwitter L Rüdiger HA Leunig M
Full Access

The direct anterior approach (DAA) is a popular minimally invasive approach for total hip arthroplasty (THA). It usually involves ligation of the lateral femoral circumflex artery's ascending branch (a-LFCA), which contributes to the perfusion of the tensor fasciae latae (TFL) muscle. Periarticular muscle status and clinical outcome were assessed after DAA-THA after a-LFCA preservation versus ligation.

We evaluated surgical records of 161 patients undergoing DAA-THA with tentative preservation of the a-LFCA by the senior author between May and November 2021. Among 92 eligible patients, 33 (35 hips) featured successful preservation, of which 20 (22 hips, 13 female) participated in the study. From 59 patients with ligated a-LFCA, 26 (27 hips, 15 female) were enrolled, constituting the control group. MRI and clinical examinations were performed at 17–26 months to analyze volume and fatty infiltration of the TFL, gluteus medius and gluteus minimus muscles relative to the contralateral non-THA hip (15 preserved, 18 ligated). Clinical and radiographic data was retrospectively extracted from patient files. Patient-reported outcomes (PROMs) were added from the THA registry.

There was a relative difference in TFL muscle volume of -6.27 cm3 (−9.89%, p=0.018) after a-LFCA preservation versus -8.6 cm3 (=11.62%, p=0.002) after ligation, without group differences (p>0.340). a-LFCA preservation showed lower relative TFL fatty infiltration (p=0.10). Gluteal muscle status was similar between sides and groups. Coxa valga morphology was more frequent in a-LFCA preservation (83%) than ligation (17%). Clinical outcomes showed high patient satisfaction in both groups, without difference in PROMs, but less anterolateral soft-tissue swelling after a-LFCA preservation (p<0.001).

Despite excellent clinical results in both groups, preservation of the a-LFCA was associated with less TFL fatty infiltration and soft tissue swelling. Provided there is no compromise of intraoperative access we recommend a-LFCA preservation for DAA-THA.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1197 - 1205
1 Jul 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

A typical pattern of blood loss associated with total hip arthroplasty (THA) is 200 ml intraoperatively and 1.3 l in the first 48 postoperative hours. Tranexamic acid (TXA) is most commonly given as a single preoperative dose only and is often withheld from patients with a history of thromboembolic disease as they are perceived to be “high-risk” with respect to postoperative venous thromboembolism (VTE). The TRanexamic ACid for 24 hours trial (TRAC-24) aimed to identify if an additional 24-hour postoperative TXA regime could further reduce blood loss beyond a once-only dose at the time of surgery, without excluding these high-risk patients.

Methods

TRAC-24 was a prospective, phase IV, single centre, open label, parallel group, randomized controlled trial (RCT) involving patients undergoing primary unilateral elective THA. The primary outcome measure was the indirect calculated blood loss (IBL) at 48 hours. The patients were randomized into three groups. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional oral regime for 24 hours postoperatively, group 2 only received the intraoperative dose, and group 3 did not receive any TXA.


Bone & Joint Research
Vol. 10, Issue 1 | Pages 22 - 30
1 Jan 2021
Clement ND Gaston P Bell A Simpson P Macpherson G Hamilton DF Patton JT

Aims

The primary aim of this study was to compare the hip-specific functional outcome of robotic assisted total hip arthroplasty (rTHA) with manual total hip arthroplasty (mTHA) in patients with osteoarthritis (OA). Secondary aims were to compare general health improvement, patient satisfaction, and radiological component position and restoration of leg length between rTHA and mTHA.

Methods

A total of 40 patients undergoing rTHA were propensity score matched to 80 patients undergoing mTHA for OA. Patients were matched for age, sex, and preoperative function. The Oxford Hip Score (OHS), Forgotten Joint Score (FJS), and EuroQol five-dimension questionnaire (EQ-5D) were collected pre- and postoperatively (mean 10 months (SD 2.2) in rTHA group and 12 months (SD 0.3) in mTHA group). In addition, patient satisfaction was collected postoperatively. Component accuracy was assessed using Lewinnek and Callanan safe zones, and restoration of leg length were assessed radiologically.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 862 - 866
1 Jul 2018
Darrith B Bell JA Culvern C Della Valle CJ

Aims

Accurate placement of the acetabular component is essential in total hip arthroplasty (THA). The purpose of this study was to determine if the ability to achieve inclination of the acetabular component within the ‘safe-zone’ of 30° to 50° could be improved with the use of an inclinometer.

Patients and Methods

We reviewed 167 primary THAs performed by a single surgeon over a period of 14 months. Procedures were performed at two institutions: an inpatient hospital, where an inclinometer was used (inclinometer group); and an ambulatory centre, where an inclinometer was not used as it could not be adequately sterilized (control group). We excluded 47 patients with a body mass index (BMI) of > 40 kg/m2, age of > 68 years, or a surgical indication other than osteoarthritis whose treatment could not be undertaken in the ambulatory centre. There were thus 120 patients in the study, 68 in the inclinometer group and 52 in the control group. The inclination angles of the acetabular component were measured from de-identified plain radiographs by two blinded investigators who were not involved in the surgery. The effect of the use of the inclinometer on the inclination angle was determined using multivariate regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 45 - 45
1 Jan 2018
Darrith B Bell J Culvern C Della Valle C
Full Access

Accurate placement of the acetabular component is essential in Total Hip Arthroplasty (THA). The purpose of this study is to determine if an analog spirit level can improve the surgeon's ability to achieve acetabular inclination within the “safe-zone” of 30 to 50 degrees.

We reviewed 167 primary THAs performed by a single surgeon over 14 months. Procedures were performed at two facilities, an inpatient hospital where a spirit level was utilized and an ambulatory facility where it was not. We excluded 47 patients with a BMI>40, age>68 or a surgical indication other than osteoarthritis who were not candidates for the ambulatory center. Cup inclination angles were measured from de-identified plain radiographs by two blinded investigators not involved in the index procedures. The effect of level usage on inclination angle was determined using multivariate regression analysis.

The mean inclination angle for the 68 hips performed with the level was 42.9 degrees (95% CI: 41.7–44.0) compared to 46.5 degrees (95% CI: 45.2–47.7) for the 52 hips without it (p<.001). Regression analysis demonstrated a 9.1% difference in cup inclination due to the level (p<.001), and THAs performed without the level were 3 times more likely to result in inclinations > 50 degrees (OR 2.8, p=.036). The two investigators' measurements demonstrated a correlation of 0.95 (95% CI: 0.93–0.97).

Use of a simple spirit level resulted in a significant reduction in the number of outliers compared to the freehand technique. The spirit level may be a simple and inexpensive tool to improve acetabular component abduction angles.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 299 - 305
1 Mar 2014
Bell KR Clement ND Jenkins PJ Keating JF

We performed a case–control study to compare the rates of further surgery, revision and complications, operating time and survival in patients who were treated with either an uncemented hydroxyapatite-coated Corail bipolar femoral stem or a cemented Exeter stem for a displaced intracapsular fracture of the hip. The mean age of the patients in the uncemented group was 82.5 years (53 to 97) and in the cemented group was 82.7 years (51 to 99) We used propensity score matching, adjusting for age, gender and the presence or absence of dementia and comorbidities, to produce a matched cohort receiving an Exeter stem (n = 69) with which to compare the outcome of patients receiving a Corail stem (n = 69). The Corail had a significantly lower all-cause rate of further surgery (p = 0.016; odds ratio (OR) 0.18, 95% CI 0.04 to 0.84) and number of hips undergoing major further surgery (p = 0.029; OR 0.13, 95% CI 0.01 to 1.09). The mean operating time was significantly less for the Corail group than for the cemented Exeter group (59 min [12 to 136] vs 70 min [40 to 175], p = 0.001). The Corail group also had a lower risk of a peri-prosthetic fracture (p = 0.042; OR 0.19, 95% CI 0.01 to 1.42) . There was no difference in the mortality rate between the groups. There were significantly fewer complications in the uncemented group, suggesting that the use of this stem would result in a decreased rate of morbidity in these frail patients. Whether this relates to an improved functional outcome remains unknown.

Cite this article: Bone Joint J 2014;96-B:299–305.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1035 - 1039
1 Aug 2013
Ebreo D Bell PJ Arshad H Donell ST Toms A Nolan JF

Metal artefact reduction (MAR) MRI is now widely considered to be the standard for imaging metal-on-metal (MoM) hip implants. The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended cross-sectional imaging for all patients with symptomatic MoM bearings. This paper describes the natural history of MoM disease in a 28 mm MoM total hip replacement (THR) using MAR MRI. Inclusion criteria were patients with MoM THRs who had not been revised and had at least two serial MAR MRI scans. All examinations were reported by an experienced observer and classified as A (normal), B (infection) or C1–C3 (mild, moderate, severe MoM-related abnormalities). Between 2002 and 2011 a total of 239 MRIs were performed on 80 patients (two to four scans per THR); 63 initial MRIs (61%) were normal. On subsequent MRIs, six initially normal scans (9.5%) showed progression to a disease state; 15 (15%) of 103 THRs with sequential scans demonstrated worsening disease on subsequent imaging.

Most patients with a MoM THR who do not undergo early revision have normal MRI scans. Late progression (from normal to abnormal, or from mild to more severe MoM disease) is not common and takes place over several years.

Cite this article: Bone Joint J 2013;95-B:1035–9.