Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 13
1 Mar 2002
Beck A Augat P Krischak G Gebhard F Kinzl L Claes L
Full Access

In vitro experiments have shown, that stabilisation of the fibula in complete fractures of the lower leg give more stability compared to a single stabilisation of the tibia. However it is not known how this biomechanical conditions influence the bone healing process. To investigate the effect of fibula stability in tibia fracture healing tibial osteotomies in rats with and without fibula fractures were compared.

Male wistar rats (n=18) were operated by a transverse osteotomy of the proximal tibia of the left leg. Fracture was stabilised by intramedullary nailing. In 8 cases an additional closed fibula fracture was performed. The healing period was 21 days.

Each whole leg was examined by x-ray. After explantation of the tibia and removing of the nail and the fibula, the tibia was examined by CT-Scan, three-point-bending and histological evaluation.

Animals, who had a fibula fracture along with the tibia fracture presented with delayed healing. Density in CT-scan was 30% lower (p=0,0002) in animals with a fibula fracture (405mg/ccm, SD:64) compared to those without a fibula fracture (mean=577mg/ccm, SD:17). In three point bending the bending stiffness was 79% lower (p=0,0006) in animals with a fibula fracture (mean=252Nmm/mm, SD:118) compared to animals without a fibula fracture (mean=1219Nmm/mm, SD:478). The breaking force was 59% lower (p=0,0004) in animals with a fibula fracture (mean=17,5N, SD:6) compared to animals without a fibula fracture (mean=42,4N, SD:14).

Complete fractures of the lower leg healed considerably worse than solitary fractures of the tibia. We conclude that the missing of rotational stability of our k-wire fixation of the tibia with a unfixed fibula fracture is one of the reasons for the delay in fracture repair. The results support the in vitro findings of the biomechanical importance of the fibula for the stability of tibia fractures.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages 14 - 14
1 Mar 2002
Beck A Augat P Krischak G Gebhard F Kinzl L Claes L
Full Access

Non-steroidal anti-rheumatics (NSAR) are often used in patients with fractured bones for analgetic reasons. This animal experiment was performed to determine the influence of NSAR on the process of fracture healing. As an alternative central acting analgetic without peripheral effect Tramadol was included in this experiment.

Wistar rats were operated by a transverse osteotomy of the proximal tibia of the left leg, fracture was stabilized by intramedullary nailing (healing period 21 days). All therapeutics were applied orally, twice a day. The animals were divided in 4 groups, 10 rats each: Group 1 was treated with placebo, group2 with tramadol (20mg/kg bodyweight/day), group3 with Diclofenac-Colestyramin (5mg/kg/bw./day) over 7 days followed by 14 days placebo, group4 with Diclofenac-Colestyramin (5mg/kg/bw./day) over 21 days. On day 21 the rats were sacrificed and each leg was examined by x-ray, than the tibia was examined by CT-Scan, three-point-bending and histological evaluation.

There were no significant differences between group1 and 2 and between group3 and 4, respectively. Therefore the data of group1 and 2 as well as group3 and 4 are put together.

The results of CT and 3-point-bending showed, that rats treated by Diclofenac presented with delayed fracture healing compared to those treated by placebo or Tramadol. Bone density was 30% lower (p = 0,0001) in animals treated with Diclofenac (mean = 577mg/ccm, SD:53,1 in group1 and 2 vs. mean = 404,3mg/ccm, SD:27,3 in group3 and 4).

The breaking force was 45% (p = 0,0009) lower (mean = 42,4N, SD:14,2 vs. mean = 23,3N, SD:8,2) and the bending stiffness 56% (p = 0,0039) lower (mean = 1218,9Nmm/mm, SD:477,9 vs. mean = 532,6Nmm/mm, SD:389,9) in animals, treated with diclofenac. Diclofenacserumlevels on day 21 in rats with longtime diclofenac application (mean = 242ng/ml, SD:47,7) were comparable to those in humans.

Oral application of Diclofenac significantly delayed fracture healing in rats. This effect might be comparable to other NSAR and fracture healing in humans.