Vol. 87-B, Issue SUPP_III | Pages 334 - 334
1 Sep 2005
Barrow A Barrow B Radziejowski M
Full Access

Introduction and Aims: Acromioclavicular dislocations and fractures of the distal clavicle present a challenging problem for the treating surgeon. The use of a new specifically designed implant was investigated. A hooked-shaped plate with fixation to the distal clavicle and ‘hook’ placement under the posterior acromion was used.

Method: The procedure was carried out on eight patients. In five patients the injury was a fractured distal clavicle. In three cases an acromioclavicular dislocation was treated. In all cases the time to returning to a functional capacity was analysed. The eventual functional result was indexed from the time of fracture union or complete stabilisation of the dislocations.

Results: All five fractures went on to anatomical union. The three dislocations were all stabilised with no instability or subluxation. In two cases patients complained of impingement symptoms with decreased overhead functional capacity. In both cases the patients regained a full and pain-free range of movement after removal of the implant.

Conclusion: This new implant provides an acceptable alternative in the management of distal clavicle fractures and acromioclavicular dislocations. The complication of impingement is encountered, but this appears to be treatable by removal of the implant after fracture union or joint stabilisation.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 78
1 Mar 2002
Barrow A Barrow B Webster P
Full Access

Acromioclavicular (AC) joint dislocations and fractures of the distal clavicle present challenging problems for the treating surgeon. We treated eight patients using a hook-shaped plate fixed to the distal clavicle and ‘hooked’ under the posterior acromion.

In five patients the injury was a fractured distal clavicle and in three an AC joint dislocation. We analysed the time taken to achieve a functional capacity. The eventual functional result was indexed from the time of fracture union or complete stabilisation of the dislocations.

All five fractures went on to anatomical union. The three dislocations were all stabilised with no instability or sub-luxation. Two patients complained of impingement symptoms and decreased overhead functional capacity. After the implant was removed, both patients regained a full range of pain-free movement.

This is a small study with limited follow-up. However, the results suggest that this new implant provides an acceptable alternative in the management of distal clavicle fractures and AC joint dislocations. The complication of impingement can be treated by removal of the implant after union or stabilisation has been achieved.