header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 3 - 3
1 Aug 2018
Barrack R Nam D Salih R Nahhas C Nunley R
Full Access

To assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular dual mobility acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design.

This was a prospective study of patients  65 years of age, with a BMI  35 kg/m2, and UCLA activity score > 6 who received a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. All patients had a minimum of 2-year clinical follow-up.

Patient reported outcome measures, whole blood metal ion levels (ug/L), and periprosthetic femur BMD were measured at baseline and at 1- and 2-years postoperatively.

43 patients (30 male, 13 female; mean age 52.6 ± 6.5 years) were enrolled. Harris Hip Scores improved from 54.1 ± 20.5 to 91.2 ± 10.8 at 2 years postoperatively (p<0.001). All patients had radiographically well-fixed components, no patients have sustained an instability event, and no patients have required a return to the operating room or revision procedure.

Mean cobalt levels increased from 0.065 ± 0.03 ug/L preoperatively to 0.30 ± 0.51 at 1-year postoperatively (p=0.01), but decreased at 2 years postoperatively to 0.16 ± 0.23 (p=0.2) (Table 1). Four patients (9.3%) had a cobalt level outside the reference range (0.03 to 0.29ug/L) at 2 years postoperatively with values from 0.32 to 0.94. None were symptomatic

The mean femoral BMD ratio was maintained in Gruen zones 2 thru 7 at both 1- and 2-years postoperatively using this stem design (Table 2). At 2 years postoperatively, BMD in the medial calcar was 101.5% of the baseline value.

Use of a modular dual mobility prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at 2 years postoperatively demonstrates the necessity of continued surveillance in this cohort.

For any figures or tables, please contact authors directly: barrackr@wustl.edu


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 36 - 36
1 Jan 2018
Ford M Hellman M Kazarian G Clohisy J Nunley R Barrack R
Full Access

Surface replacement arthroplasty (SRA) has been proposed as a viable option for the treatment of osteoarthritis in young, active patients. Positive results of the Birmingham Hip Resurfacing (BHR) in select patient groups have been described in international series and registry data. We report 5–10 year U.S. follow-up for the BHR at our high volume institution.

314 patients (361 hips) between 2006–2011 underwent BHR at our institution and agreed to participate in research. Demographic features, modified Harris Hip Score, UCLA Activity Score, and satisfaction were recorded for patients with minimum 5-year follow-up (90%). Radiographs were evaluated for implant position and “at risk” signs. Complications, reoperations, and revisions were investigated.

Mean modified Harris Hip and UCLA scores significantly improved postoperatively to scores of 89.96 and 7.90 (p < 0.001), respectively. Kaplan-Meier estimated survival for all-cause revision was 96.7% [95% CI 94.7 – 98.7%] at 5 years and 91.5% [95% CI 85.3 – 97.6%] at 10 years. Estimated survival for aseptic revision in males less than 60 years old with a primary diagnosis of osteoarthritis was 99.5% [95% CI 98.7 – 100%] at 5 years and 98.8% [95% CI 97.0 – 100%] at 10 years. 14 patients required revision, including 5 revisions for adverse local tissue reaction.

Our study demonstrated excellent survivorship and clinical outcomes at 5–10 year follow up for the BHR. These results mirror other series and registry data published outside of the United States. Continued long-term follow-up and additional studies are necessary to validate the long-term safety and outcomes of the BHR, especially in young active arthroplasty patients.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 36 - 43
1 Jan 2018
Hambright D Hellman M Barrack R

Aims

The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging.

Patients and Methods

A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image.