Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 75 - 75
1 Dec 2021
Carrasco FC Karbysheva S Pérez-Prieto D Margaryan D Barbera OF Trampuz A Garcia JCM
Full Access

Aim

Quadrupled hamstring anterior cruciate ligament plasties (4xHp) have been described as having a higher risk of infection than bone patellar tendon bone plasties (BPTBp). There are 2 theories that might explain this phenomenon. One is the presence of sutures in a 4xHp that could act as a foreign body, The other is the more complex preparation of a 4xHp that might lead to higher contamination rates during the process. The objective of the present study was to evaluate the formation of biofilm in these plasties and to compare it between a 4xHp and a BPTBp. The hypothesis was that the presence of sutures in 4xHp would increase the amount of biofilm present in them in comparison to BPTBp.

Method

A descriptive in vitro study was conducted. One 4xHp and one BPTBp were prepared. They were subsequently divided into 8 fragments. Three of them were reserved for negative control, and the rest were contaminated with a strain of S. Epidermidis (ATCC 35984) 10–5. Finally, a quantitative analysis was carried out by means of microcalorimetry and sonication with plating. Additionally, a qualitative analysis was carried out by means of electron microscopy.