Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 6 - 6
1 Dec 2023
Allott N Banger M Korgaonkar J Thomas R McGregor A
Full Access

Introduction

Anterior tibial translation (ATT) is assessed in the acutely injured knee to investigate for ligamentous injury and rotational laxity. Specifically, there is a growing recognition of the significance of anterior medial rotary laxity (AMRI) as a crucial element in assessing knee stability. Anterior cruciate ligament (ACL) injuries are often accompanied with medial collateral ligament (MCL) damage. It has been suggested that Deep MCL (dMCL) fibres are a primary restraint in rotational displacement. This research aims to quantify the difference in rotational laxity of patients with ACL and MCL injuries to deem if the Feagin-Thomas test can robustly capture metrics of AMRI. 2.

Methods

AMRI was assessed using the Feagin-Thomas test in 7 isolated ACL (iACL) injured participants, 3 combined ACL and superficial fibre MCL (sMCL) injuries, 5 combined ACL and deep fibre MCL injuries, and 21 healthy controls. Displacement values were recorded using an optical motion capture (OMC) system and bespoke processing pipeline which map and model the knee's anterior displacement values relative to the medial compartment. Since absolute values (mm) of rotational laxity vary dependant on the person, values were recorded as a proportion of the rotational laxity obtained from the subject's contralateral leg. Values were compared between each patient group using an ANOVA test and Tukey's honesty significant difference post hoc test. 3.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1088 - 1095
1 Jun 2021
Banger M Doonan J Rowe P Jones B MacLean A Blyth MJB

Aims

Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs.

Methods

The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 89 - 89
1 Aug 2013
Banger M Rowe P Blyth M
Full Access

Time analysis from video footage gives a simple outcome measure of surgical practice against a measured model of use. The added detail that can be produced, over simply recording the usual surgical process data such as tourniquet times, allows us to identify and time the sequence of surgical procedures as stages, to describe issues, and the identification of idiosyncratic behaviours for review and comparison.

Makoplasty (Mako surgical corp. FL, US) partial knee operation times were compared using this technique with those from the Oxford (Biomet, IN, US) partial knee. Three experienced surgeons were observed over 19 Makoplasty procedures ([Consultant 1] 11, [Consultant 2] 5, [Consultant 3] 3) and 2 experienced surgeons over 11 Oxford partial knee procedures ([Consultant 1] 5, [Consultant 2] 6). Times were refined into separate stages that defined the major operative steps of both the Makoplasty and Oxford processes as used by the surgical team at the Glasgow Royal Infirmary, UK. The videos were reviewed for start and stop times for pre-defined actions that would be expected to be observed during each surgical process and from these stage lengths were calculated. For both the Oxford and Mako system 12 comparable stages were identified for comparison and the timing of the various episodes was tested for statistical significance using a Two-Sample, two tail, t-Test. assuming Equal Variances. [Stages: 1. Setup time, 2. Patient on table, 3. Skin incision, 4. Joint Prep, 5. Robot registration (Not in Oxford), 6. Tibial resection, 7. Femoral resection, 8. Trials, 9. Finishing, 10. Cementing and Washout, 11. Closure and dressing, 12. Off table]

The MAKOplasty procedures were on average longer than Oxfords by 27 minutes. This can largely be accounted for in the additional setup stage 4, where in addition to the usual joint preparation taking a couple of minutes approximately 17 minutes were spent in the MAKO cases undertaking image registration and in stage 5 where nearly five minutes were spent in setting up the robot in the MAKO cases.

In conclusion while operative times fell for the Makoplasties across the learning curve they remained elevated once the plateau was reached. It should be remembered that the surgeons had much less experience with the Makoplasty procedure and were undertaking a randomised clinical trial of outcome and hence were not minded to perform the surgery quickly but to the best of their ability and that this may account for some of the elongated surgical time. Indeed other Makoplasty surgeons report an average surgical time of 30–45 minutes per case and 6 cases per day. What is striking is that the additional steps of registration and robot positioning account for a large proportion of the differences and these are mitigated to some extent by quicker trialling of the implant and finishing of the cuts suggesting more confidence in the suitability of the cut surfaces. There is clearly a need to reduce the registration time to produce more cost effective surgeries.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 88 - 88
1 Aug 2013
Banger M Rowe P
Full Access

There is an increasing prevalence of haptic devices in many engineering fields, especially in medicine and specifically in surgery. The stereotactic haptic boundaries used in Computer Aided Orthopaedic Surgery Unicomparmental Knee Arthroplasty (CAOS UKA) systems for assistive milling control can lead to an increase in the force required to manipulate the device; this study presented here has seen a several fold increase in peak forces between haptic and non-haptic conditions of a semi-active preoperative image system.

Orthopaedic Arthroplasty surgeons are required to apply forces ranging from large gripping forces to small forces for delicate manipulation of tools and through a large range of postures. There is also a need for surgeons to move around and position themselves to gain line of sight with the object of interest and to operate while wearing additional clothing such as the protective headwear and double gloves. These factors further complicate comparison with other ergonomic studies of other robotics systems. While robotics has been implemented to reduce fatigue in surgery one area of concern in CAOS is localised user muscle fatigue in high volume use.

In order to create the conditions necessary for the generation of fatigue in a realistic user experience, but in the time available for the participants, an extended period of controlled and prolonged cutting and manipulation of the robotic arm was needed. This pragmatic test requirement makes the test conditions slightly artificial but does indicate areas of high potential for fatigue when interacting with the system in high volume instances.

The surgeon-robotic system interaction was captured using 3 dimensional motion analysis and a force transducer embedded in the end effector of the robotic arm and modelled using an existing upper body model in Anybody software. The kinematic and force information allowed initial calculations of the interaction between the user and the Robotic system. Validation of the model was conducted using Electromyography assessment of activity and fatigue. Optimisation of the model sought to create an efficient cutting regime to reduce cutting time with reduced muscle force in an attempt to reduce users discomfort/fatigue while taking into account anthropometric variations in the users and minimising overall energy requirements, burr path length and maximum muscle force.

From the assessment of a small group of three surgeons with experience of the Robotic system there was little to no experience of above normal localised fatigue during small volume use of the system. Observation of these surgeons operating the robot state otherwise with examples of reactions to discomfort. There is also anecdotal evidence that fatigue becomes more problematic in higher volume work loads.