To investigate differences between the Reamer Irrigator Aspirator and the AO reamer on fat embolism outcome using a porcine model.

All animal procedures were approved and performed in accordance with the Animal Care Committee at St. Michael’s hospital. Following anesthetic administration, the animals were stabilised for thirty minutes. One third of the pig’s blood volume was withdrawn to simulate hemorrhagic shock. Each animal was kept in a state of hypovolemia for an hour before transfusion and resuscitation. Once the animal was stabilised surgical exposure of the distal femur was completed. A 12 mm Reamer Irrigator Aspirator or AO reamer was used depending on which group the animal was assigned to. Blood work was obtained at: baseline, immediately after induction of hypovolemia, one hour post hypovolemia, post stabilization, one minute, five minutes, 1.5 hours and three hours after reaming. The results were analyzed for activation of the coagulation system, platelet and neutrophil activation, and cytokine elevation. ANOVA was the primary tool used to assess statistical significance.

There was no statistical difference between the two reamers with respect to PT, APTT, and fibrinogen. There was a statistical difference in D-dimer at 1.5 and three hours post-reaming, with the RIA showing a lower value. Neither reamer demonstrated any systemic platelet nor neutrophil activation. TNF-alpha spiked immediately post-reaming with the RIA group returning to baseline values and the AO group remaining elevated. There is a spike in IL-1B post reaming in the AO group, however this was not seen in the RIA group. No statistical difference was detected between the two reamers.

All markers for platelet and neutrophil activation and the coagulation cascade were measured at the systemic level. Although there is no statistical difference between the RIA and AO reamer, it is possible that activated cells were removed from the systemic circulation and sequestered as thrombi in the pulmonary microvasculature. This hypothesis may be supported by a drop in platelet count and an increase in D-dimer, with the AO reamer suggesting greater thrombi formation. The trends in IL-1B and TNF-alpha seem to suggest that the RIA abrogates the post-reaming proinflammatory state.