There is a lack of evidence as to the best way to deliver rehabilitation following TKA. Previous work has suggested that postoperative physiotherapy applied to all patients is not effective at improving one-year post-surgical outcomes. The aim of this study was to target physiotherapy to those at risk of poor outcome following TKA, and to determine if a therapist-led intervention offered superior results compared to a home-exercise based protocol in this ‘at risk’ group. The Targeted Rehabilitation to Improve Outcomes (TRIO) study was a prospective randomised controlled trial run at 15-centres in the UK. Patients were identified as ‘potential poor outcome’ based on an Oxford Knee Score (OKS) classification at 6-weeks post-surgery and randomised to either therapist-led or home-exercise based protocols. Patients were reviewed by a physiotherapist and commenced 18-exercise sessions over 6-weeks. The therapist-led group undertook a progressive functional protocol (modified weekly in 1-1 contact sessions) in contrast to the static home-exercise based regime. Evaluation took place following rehabilitation intervention, then at 6-months and 1-year post-surgery. Primary outcome was comparative group OKS at 1-year. Secondary outcomes included, ‘worst’ and ‘average’ pain scores, OXS and EQ-5D, and satisfaction questionnaire. Health economic (cost-utility) analysis was undertaken from NHS perspective up to 1-year post-surgery. Incremental cost per Quality Adjusted Life Years (QALYs) were calculated from intervention costs, patient reported primary and secondary care usage, and EQ-5D data. 4264 patients were screened, 1296 were eligible, 334 patients were randomised, 8 were lost to follow-up, therapy compliance was >85%. Clinically meaningful improvement in OKS (between baseline and 1-year) was seen in both arms (p < 0 .001). Between group difference in 1-year OKS was 1.91 (95%CI, −0.17–3.99) points favouring the therapist-led arm (p=0.07). Incorporating all time point data, between group difference in OKS was 2.25 points (95%CI, 0.61–3.90, p=0.008). Small, non-significant reductions (< 5 %) in both worst and average pain scores were observed favouring the therapist-led group. Enhanced satisfaction with pain relief (OR 1.65, p < 0 .02), ability to perform daily functional tasks (OR 1.66, p < 0 .02), and perform heavy functional tasks (OR 1.6, p=0.04) was reported in the therapist-led group. There was a small non-significant difference of 0.02 points (95%CI −0.02–0.06) between groups in EQ-5D, resulting in a £12,125 cost per QALY of delivering the therapist led intervention with a 57% chance of being cost-effective at the standard UK policy threshold of £20,000 per QALY. TRIO is the largest randomised trial of physiotherapy following TKA, and the first to target rehabilitation to patients at risk of poor outcomes. Both therapist-led and home-exercise based rehabilitation groups made clinically meaningful improvements in outcome by 1-year. We observed a modest difference in OKS in favour of therapist-led rehabilitation compared to the home-exercises which was not statistically significant. The relatively tight confidence intervals suggests that any difference which might exist is too small to be clinically relevant. Patient satisfaction with outcome was however higher in those that received greater physiotherapist contact. While cost per QALY estimates were below UK policy threshold, this result is uncertain and insufficient to make accept-decline recommendations.
Knee arthroplasty is an effective intervention for painful arthritis when conservative measures have failed. Despite recent advances in component design and implantation techniques, a significant proportion of patients experience problems relating to the patella-femoral joint (PFJ). Detailed knowledge of the shape and orientation of the normal and replaced femoral trochlea groove is critical when considering potential causes of anterior knee pain. Furthermore, to date it has proved difficult to establish a diagnosis due to shortcomings in current imaging techniques for obtaining satisfactory coronal plane motion data of the patella in the replaced knee. The aim of this study was to correlate the trochlea shape of normal and replaced knees with corresponding coronal plane PFJ kinematic data. Bony and cartilagenous trochlea geometries from 3T MRI scans of 20 normal healthy volunteers were compared with both anatomical and standard total knee replacements (TKR) and patellofemoral joint replacement (PFJR) geometries. Following segmentation and standardized alignment, the path of the apex of the trochlea groove was measured using customized Matlab software. (Fig1). Next, kinematic data of the 20 normal healthy volunteers (Normal) was compared with that of 20 TKR, and 20 PFJR patients using the validated MAUSTM system Introduction
Method
Previous attempts to measure coronal plane patellofemoral kinematics following knee replacement have suffered from methodological drawbacks; the patella being obscured by the components, metal artefact and technical inaccuracies. The aim of this study was to assess whether there was any significant difference in the patellofemoral kinematics between normal, TKR and PFJR patients using the validated MAUS™ technique (combining motion analysis with ultrasound). 60 patients were recruited into three groups; normal healthy volunteers (Normal), TKR, and PFJR patients. The MAUS technique incorporates a 12 camera analysis system (providing gross alignment data for tibial and femoral segments) and an ultrasound probe (providing coordinates of bony landmarks on patella femur and tibia) during a squat exercise. 6 DOF kinematics were described between 0 and 90° flexion. The validated accuracy of the MAUS technique registering the ultrasound images within the motion capture system is 1.84 mm (2 × SD). Movements of the Normal group were significantly different from the TKR group (p=0.03) and the PFJR group (p<0.01), whilst there was no significant difference between the TKR and PFJR groups (p=0.27). Our data suggest that many aspects of patellofemoral kinematics are absent following TKR and PFJR, which could be addressed in future designs of knee TKR and PFJR.
This study examines variations in knee arthroplasty patient reported outcome measures according to patient age. We analysed prospectively collected outcome data (OKS, Eq5D, satisfaction, and revision) on 2456 primary knee arthroplasty patients. Patients were stratified into defined age groups (< 55, 55–64, 65–74, 75–84, and ≥85 years). Oxford Knee Score and Eq5D were analysed pre-operatively, and postoperatively at 6 months and 2 years. Absolute scores and post-operative change in scores were calculated and compared between age groups. Satisfaction scores (0–100) were analysed at 6 months post-operatively. Linear, logistic and ordinal regression modelling was used to describe the association between age and outcomes, for continuous, binary and ordinal outcomes, respectively. Kaplan-Meier analysis was performed to describe revision rates at 2 years.Objectives
Methods
There is uncertainty about the relationship between improvement in range of motion (ROM) and functional outcome or patient satisfaction after total hip arthroplasty (THA). Using data from a prospective multi-centre study we investigated this relationship. We recorded the Oxford Hip Score (OHS), Merle d'Aubigne and Postel score (MDA) and range of motion (ROM) preoperatively and at one and five years and a patient satisfaction questionnaire at five years. Complete 5 year data were available for 342 patients.Introduction
Methods
We examined data from a large prospectively collected dataset which followed up patients after Exeter total hip replacement (THR) - the Exeter Primary Outcome Study. We studied 78 patients who had total hip replacement for osteoarthritis on a morphologically normal hip, and in whom the other hip was also morphologically normal for comparison. All selected patients had complete patient outcome data at 1 and 5 years, and x-rays at 1 year were available. We measured accuracy of reconstruction on AP Pelvis radiographs. The parameters measured were difference in height of lesser trochanter from horizontal pelvic line (LLD); length from ASIS to greater trochanter (indicating abductor length, AL); length from symphysis to centre of femoral head (SFH); length from centre of head to axis of femur (offset). We examined clinical outcomes including gain of Oxford Hip Score (DOHS) at 1 and 5 years, absolute OHS at 1 and 5 years, and absolute SF-36 Physical Functioning and Role Physical scores at 1 and 5 years. Examining the ratios of AL, SFH, Offset, Offset to SFH ratio and LLD between side of THR and unaffected side all showed marked variation. Thus the ratio of SFH varied from 0.85 to 1.11. For further analysis we divided the patients into 3 groups on the basis of variability of the ratio from 1; we examined whether the clinical scores above varied between these 3 groups. 1 way ANOVA demonstrated no significant difference for any of the clinical outcomes for any of the 5 grouped x-ray variables. Accuracy of reconstruction has been shown to affect the risk of dislocation after THR. Our results indicate that clinical outcomes of total hip replacement appear resilient to some degree of surgical inaccuracy. Future trials of navigation should be designed to demonstrate not only improved accuracy but also improved clinical outcome.
Despite interest, the current rate of day-case anterior cruciate ligament reconstruction (ACLR) in the UK remains low. Although specialised care pathways with standard operating procedures (SOPs) have been effective in reducing length of stay following some surgical procedures, this has not been previously reported for ACLR. We evaluate the effectiveness of SOPs for establishing day-case ACLR in a specialist unit. Fifty patients undergoing ACLR between May and September 2010 were studied prospectively (“study group”). SOPs were designed for pre-operative assessment, anaesthesia, surgical procedure, mobilisation and discharge. We evaluated length of stay, readmission rates, patient satisfaction and compliance to SOPs. A retrospective analysis of 50 patients who underwent ACLR prior to implementation of the day-case pathway was performed (“standard practice group”).Background
Methods
Interest in soft tissue Radiostereometric Analysis (RSA) is rising. Previous authors have tried, with varying levels of success, to use this technique to analyse the intra-substance portion of anterior cruciate ligament (ACL) graft constructs. These methods were either prone to large amounts of marker migration, deemed unsuitable for in-vivo use or, where alternative markers such as stainless steel sutures were used, lost the inherent accuracy that made RSA an attractive tool in the first place. We describe a modification of tantalum marker balls that allows for a new method of secure fixation to soft tissue in order to accurately analyse stretch, displacement and, potentially, dynamic movement using RSA. 1.5 mm tantalum tendon markers were predrilled with 0.3 mm holes, allowing them to be sutured directly to soft tissue. Using a previously described ACL graft model, the amount of marker ball migration was then analysed using RSA after cyclical loading between 20 N and 170 N at 25 Hz for 225,000 cycles.Aims
Methods
Acetabular cup lucency predicts cup survival. The relationship of subchondral plate removal and cup survival is unclear. Using data from a prospective study conducted between January 1999 and January 2002 we investigated the role of subchondral plate removal in cemented acetabular cup survival at five years. A number of cemented cups were implanted using antero-lateral and posterior approaches.1400 cups were inserted. 935 cups (67%) were followed up at 5 years and acetabular radiolucency (AR) recorded.Introduction
Methods
A femoral head/neck ratio (HNR) of less than 1.27 is associated with an increased risk of arthritis. The aim of this study was to establish whether there is evolutionary evidence that the homonin, bipedal stance has led to alterations in HNR that predispose humans to osteoarthritis (OA). Specimens provided by The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford were grouped according to gait pattern, HAKF (Hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and homonin/bi-pedal. Specimens included those from Devonion, Triassic, Jurrasic, Cretaceous, Miocene, Paleolithic, Pleistocene periods to modern day. Three-dimensional skeletal geometries were segmented using CT images and HNR measurements were taken from coronal views. These were compared with the HNR of 119 asymptomatic human volunteers and 210 patients that had a hip joint replacement for primary OA. Species of the HAKF group had the smallest HNR (1.10, SD:0.09). Species of the Arboreal group had significantly higher HNR (1.63, SD:0.15) in comparison to the Bipedal group (1.41, SD:0.04) (p=0.006), Human (1.33, SD:0.08) and the OA group (1.3, SD:0.09). The range of movement associated with arboreal habitat caused an associated change in HNR. This study would suggest that the HNR peaked in the Miocene period with species that ambulated on both ground and trees. More recent homonin gait appears to have developed a smaller HNR and humans have the smallest amongst their close ancestors. Evolutionary theory would suggest that modern environmental pressures might pre-dispose future hominin evolution to OA, secondary to a further reduction in HNR.
Preoperative psychological distress has been reported to predict poor outcome and patient dissatisfaction after total hip replacement (THR). We investigated this relationship in a prospective multi-centre study between January 1999 and January 2002. We recorded the Oxford Hip Score (OHS) and SF36 score preoperatively and up to five years after surgery and a global satisfaction questionnaire at five year follow up for 1039 patients. We dichotomised the patients into the mentally distressed (Mental Health Scale score - MHS <50) and the not mentally distressed (MHS (50) groups based on their pre-operative MHS of the SF36. 776 (677 not distressed and 99 distressed) out of 1039 patients were followed up at 5 years.Introduction
Methods
This study aims to investigate femoral blood flow during Metal-on-Metal Hip Resurfacing (MMHR) by monitoring oxygen concentration during the operative procedure. Patients undergoing MMHR using the posterior approach were evaluated. Following division of fascia lata, a calibrated gas-measuring electrode was inserted into the femoral neck, aiming for the supero-lateral quadrant of the head. Baseline oxygen concentration levels were detected after electrode insertion 2-3cm below the femoral head surface and all intra-operative measures were referenced against these. Oxygen levels were continuously monitored throughout the operation. Data from ten patients are presented. Oxygen concentration dropped most noticeably during the surgical approach and was reduced by 62% (Std.dev +/-26%) following dislocation and capsulectomy. Insertion of implants resulted in a further oxygenation decrease by 18% (Std.dev +/-28%). The last obtained measure before wound closure detected 22% (Std.dev +/-31%) of initial baseline oxygen levels. Variation between subjects was observed and three patients demonstrated a limited recovery of oxygen levels during implant insertion and hip relocation. Intra-operative measurement of oxygen concentration in blood perfusing the femoral head is feasible. Results in ten patients undergoing MMHR showed a dramatic effect on the oxygenation in the femoral head during surgical approach and implant fixation. This may increase the risk of avascular necrosis and subsequent femoral neck fracture. Future experiments will determine if less invasive procedures or specific positioning of the limb can protect the blood supply to femoral neck and head.