Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 6 - 6
1 Sep 2012
Burkhart TA Dunning CE Andrews DM
Full Access

Purpose

Fractures to the distal radius are costly and debilitating injuries. While it is generally accepted that the leading cause of these injuries is a fall onto an outstretched arm, the mechanics of the injury are less well understood. The main limitations of past research are the use of unrealistic loading rates or uncontrolled loading protocols. Therefore, the purpose of this research was to examine the mechanical response of the distal radius pre-fracture and at fracture, under dynamic loads indicative of a forward fall.

Method

Eight cadaveric radius specimens were cleaned of all soft tissues and potted at a 75o angle (representative of the angle between the volar radius and the ground) up to the distal third of the radius. A custom designed pneumatic impact system was used to apply impulsive impacts to the specimen at increasing energy levels until failure occurred. The intra-articular surface of the radius rested against a model scaphoid and lunate made from high density polyethylene (Sawbones) attached to a 5 degree of freedom load cell that in turn was attached to an impact plate. The position of the carpals within the intra-articular surface simulated 45o of wrist extension. Following failure (defined as the specimen being fractured into at least 2 distinct pieces), the specimens were removed from the testing apparatus and the location, type, pattern and severity of injury was noted and classified using the Frykman and Melone classification systems. Energy input and force variables were also collected at failure.