Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 7 - 7
1 Feb 2013
Stevenson A Lougher L Cumming S Clark D Amirfeyz R
Full Access

The trapeziometacarpal joint (TMJ) is the most commonly involved arthritic joint in the hand and is often injected in the outpatient setting. This study assesses the accuracy of TMJ injections.

Six pairs of thawed, fresh-frozen cadaveric upper limbs were placed in the anatomic position. The limbs were randomized to be injected by one of two clinicians (a senior and a junior orthopaedic trainee). The TMJ of these specimens was palpated and injected with 0.5mls aqueous jelly dyed with methylene blue. An independent investigator dissected the specimens and the location of the dye was recorded. A Posterior-Anterior radiograph was then taken to assess the bony anatomy of the joint and graded according to Eaton's classification.

Dye was found inside the joint capsule in 10 (83%) of the 12 specimens. Using Fishers Exact test no significant difference was found between the 2 injectors (p=0.46). The 2 joints where the dye was extra-articular had grade III and IV arthritis, whereas all other joints were graded I.

This study shows that good accuracy of TMJ injection can be achieved using palpation in the earlier stages of TMJ arthritis, when surface anatomy is accurate enough for an intra-articular injection. This is also when synovitis is more prevalent and injections are more relevant. However the failure rate of injections increases as the disease advances.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 2 - 2
1 Feb 2013
McCann P Sarangi P Baker R Blom A Amirfeyz R
Full Access

Total Shoulder Resurfacing (TSR) provides a reliable solution for the treatment of glenohumeral arthritis. It confers a number of advantages over traditional joint replacement with stemmed humeral components, in terms of bone preservation and improved joint kinematics.

This study aimed to determine if humeral reaming instruments produce a thermal insult to subchondral bone during TSR. This was tested in vivo on 13 patients (8 with rheumatoid arthritis and 5 with osteoarthritis) with a single reaming system and in vitro with three different humeral reaming systems on saw bone models. Real-time infrared thermal video imaging was used to assess the temperatures generated.

Synthes Epoca instruments generated average temperatures of 40.7°C (SD 0.9°C) in the rheumatoid group and 56.5°C (SD 0.87°C) in the osteoarthritis group (p = 0.001). Irrigation with room temperature saline cooled the humeral head to 30°C (SD 1.2°C). Saw bone analysis generated temperatures of 58.2°C (SD 0.79°C) in the Synthes (Epoca) 59.9°C (SD 0.81°C) in Biomet (Copeland) and 58.4°C (SD 0.88°C) in the Depuy (CAP) reamers (p=0.12).

Humeral reaming with power driven instruments generates considerable temperatures both in vivo and in vitro. This paper demonstrates that a significant thermal effect beyond the 47°C threshold needed to induce osteonecrosis is observed with humeral reamers, with little variation seen between manufacturers. Irrigation with room temperature saline cools the reamed bone to physiological levels, and should be performed regularly during this step in TSR.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 53 - 53
1 Jan 2013
Thyagarajan D Amirfeyz R Blewitt N
Full Access

Total Elbow Replacements are indicated for pain and disability in patients with rheumatoid and osteoarthritis of the elbow. The quality of the cementation has been specifically studied and shown to be directly related to the clinical outcome and implant survival.

Aim

The aim of our study is to radiologically assess and grade the cementation around the components following total elbow replacement (GSB 3 or Coonrad Morrey) in two groups of patients.

Materials and methods

Group I underwent total elbow replacement using Heraeus cement gun with medium palacos viscosity cement and group 2 using Zimmer cement gun with simplex medium viscosity cement. Average age in Group 1 was 72.3 (range 67–88 yrs) and group 2 was 69 years (range 52–87 yrs)

3 Coonrad Morrey and 13 GSB 3 total elbow replacement were used in Group 1 and 2 Coonrad Morrey and 14 GSB 3 in group 2. The primary indication for surgery was osteoarthritis, rheumatoid arthritis, post traumatic arthritis and seronegative arthritis in both groups. The cementation was assessed radiologically using three grading system (Morrey, Gerber & Bristol).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 8 - 8
1 Sep 2012
Blackburn J Qureshi A Amirfeyz R Bannister GC
Full Access

Approximately one-fifth of patients are not satisfied with total knee arthroplasty (TKA). Preoperative variables associated with poorer outcomes are severity and chronicity of pain and psychological disease, which may present as anxiety and depression. It is unclear whether this is constitutional or the result of knee pain. To address this, we explored the association of anxiety and depression with knee disability before and after TKA.

Forty patients undergoing TKA completed Hospital Anxiety and Depression Scale (HADS) and Oxford Knee Scores (OKS) preoperatively and at three and six months postoperatively. Both were elevated preoperatively and improved significantly post-operatively (P<0.001). The severity of preoperative anxiety and depression was associated with worse knee disability (coefficient −0.409, p=0.009). Postoperatively reduction in anxiety and depression was associated with improvement in knee disability after three (coefficient −0.459, p=0.003) and six months (coefficient −0.428, p=0.006).

The difficulty in interpreting preoperative anxiety and depression and the outcome of TKA is establishing whether they are the cause or effect of pain in the knee. As anxiety and depression improves with knee pain and function, this study suggests that knee pain contributes to the psychological symptoms and that a successful TKA offers an excellent chance of improving both.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 108 - 108
1 Sep 2012
Burston B Barnett A Amirfeyz R Yates P Bannister G
Full Access

We have prospectively followed up 191 consecutive primary total hip replacements utilising a collarless polished tapered (CPT) femoral stem, implanted in 175 patients between November 1992 and November 1995.

At a mean follow-up of 15.9 years (range 14 – 17.5) 86 patients (95 hips) were still alive (25 men and 61 women) and available for routine follow up. Clinical outcome was determined from a combination of the Harris (HHS) and Oxford (OHS) hip scores. Radiological assessment was with antero-posterior radiographs of both hips and a lateral radiograph of the operated hip. The radiographs were evaluated using well-recognised assessment techniques.

There was no loss to follow up, with clinical data available on all 95 hips. Five patients were too frail to undergo radiographic assessment, therefore radiological assessment was performed on 90 hips (95%). At the latest follow-up, the mean HHS was 78 (range 28 – 100) and the mean OHS was 36 (range 15 – 48). Stems subsided within the cement mantle, with a mean total subsidence of 2.1mm (range 0.4 – 24). Higher grades of heterotopic bone formation were significantly associated with males (p<0.001) and hypertrophic osteoarthritis (p<0.001). Acetabular wear was associated with increased weight (p<0.001) and male sex (p=0.005). Amongst the cohort, only 1 stem (1.1%) has been revised due to aseptic loosening. This patient required reaming of their canal prior to implantation, as a result of a previous femoral osteotomy. The rate of stem revision for any cause was 7.4% (7 stems), of which 4.2% (4 stems) resulted from infection following revision of the acetabular component. Twenty patients (21.1%) required some sort of revision procedure; all except 3 of these resulted from failure of the acetabular component. Cemented cups had a significantly lower revision burden (2.7%) than Harris Galante uncemented components (21.8%) (p<0.001).

The CPT stem continues to provide excellent radiological and clinical outcomes at 15 years following implantation. Its results are consistent with other polished tapered stem designs. Cup failure remains a problem and is related in part to inadequate bearings and biological abnormalities.