14.1% of men &
22.8% of women over 45 years show symptoms of osteoarthritis OA of the knee [ CT and MRI data of a cadaveric knee were used to create geometrically accurate 3D models of the femur, tibia, fibula, menisci and cartilage and tendon of the knee joint, using the Mimics V12.11 commercially-available software (Materialise, Belgium). The Simulation module was used to register the bones and the soft tissues. The resulting STL files were exported to CATIA V5R18 pre-processor to generate surface meshes and create the corresponding 3D solid and FE models of the osseous and soft tissues from the STL cloud of points. The Young’s moduli for cortical bone, cancellous bone, cartilages, menisci and ligaments were taken from literature as 17 GPa, 500 MPa, 12 MPa, 60 Mpa and 1.72 MPa respectively [ FE analysis results of this study show that HTO reduces stresses in specific regions of the knee, which are associated with OA progression [
In our unit we noted a number of complications resulting from suboptimal fracture fixations of ankles some of which required revision. It was decided to review fracture fixation of ankles in the unit to see whether the basic principles of fixation was being followed in our DGH.
In every case the fibula fixation did not include a cortical lag screw.
By ensuring that operating surgeons have the appropriate training and experience in basic fracture fixation before being allowed to undertake such procedures, our unit hopes to show an improvement on these figures by the time this audit is repeated.
The reduced stability of hydroxyapatite (HA)-coated implants in osteopenic conditions is considered to be a major problem. We therefore developed a model of a boosted cementless implantation in osteopenic rats. Twelve-week-old rats were either ovariectomised (OVX) or sham-operated (SO), and after 24 weeks plain or HA-coated implants were inserted. They were treated with either a prostaglandin EP4 receptor agonist (ONO-4819) or saline for one month. The EP4 agonist considerably improved the osteoporosis in the OVX group. Ultrastructural analysis and mechanical testing showed an improvement in the implant-bone attachment in the HA-coated implants, which was further enhanced by the EP4 agonist. Although the stability of the HA-coated implants in the saline-treated OVX rats was less than in the SO normal rats, the administration of the EP4 agonist significantly compensated for this shortage. Our results showed that the osteogenic effect of the EP4 agonist augmented the osteoconductivity of HA and significantly improved the stability of the implant-bone attachment in the osteoporotic rat model.