header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 219 - 219
1 Dec 2013
Kurdziel M Ackerman J Salisbury M Baker E Verner JJ
Full Access

Purpose:

Acetabular bone loss during revision total hip arthroplasty (THA) poses a challenge for reconstruction as segmental and extensive cavitary defects require structural support to achieve prosthesis stability. Trabecular metal (TM) acetabular augments structurally support hemispherical cups. Positive short-term results have been encouraging, but mid- to long-term results are largely unknown. The purpose of this study was to determine the continued efficacy of TM augments in THA revisions with significant pelvic bone loss.

Methods:

Radiographs and medical records of 51 patients who had undergone THA revision with the use of a TM augment were retrospectively reviewed. Acetabular defects were graded according to the Paprosky classification of acetabular deficiencies based on preoperative radiographs and operative findings. Loosening was defined radiographically as a gross change in cup position, change in the abduction angle (>5°), or change in the vertical position of the acetabular component (>8 mm) between initial postoperative and most recent follow-up radiographs (Figure 1).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 166 - 166
1 Dec 2013
Kurdziel M Sabesan V Ackerman J Sharma V Baker K Wiater JM
Full Access

Purpose:

The optimal degree of conformity between the glenoid and humeral components in cemented total shoulder arthroplasty (TSA) has not been established. Glenoid component stability is thought to be at risk due to the “rocking-horse” phenomenom, which, can lead to increased micromotion and loosening in response to humeral head edge loading. The goal of this biomechanical study is to investigate the influence of glenohumeral mismatch on bone-implant interface micromotion in a cemented glenoid implant model.

Methods:

Twenty-Five cemented glenoid components (Affiniti, Tornier, Inc., Bloomington, MN, USA) were implanted in polyurethane foam biomechanics testing blocks. Five glenoid sizes, 40 mm, 44 mm, 48 mm, 52 mm and 55 mm (n = 5 per glenoid size), were cyclically tested according to ASTM Standard F-2028-08. A 44 mm humeral head (Affiniti, Tornier, Inc., Bloomington, MN, USA) was positioned centrally within the glenoid fixed to a materials testing frame (MTS Mini-Bionix II, Eden Prairie, MN, USA). Phase I testing (n = 3 per glenoid size) involved a subluxation test for determination of the humeral head translation distance which would be used for phase II cyclic testing. During cyclic loading, the humeral head was translated ± distance for 50,000 cycles at a frequency of 2 Hz, simulating approximately 5 years of device use. Glenoid compression, distraction, and superior-inferior glenoid translation were measured throughout testing via two differential variable reluctance transducers.