The prevalence of obesity is increasing substantially around the world. Elevated BMI increases the risk of complications following total hip arthroplasty (THA). We sought to evaluate trends in BMI and complication rates of obese patients undergoing primary THA over the last 30 years. Through our institutional total joint registry, we identified 15,455 primary THAs performed for osteoarthritis from 1990 to 2019. Patients were categorized according to the World Health Organization (WHO) obesity classification and groups were trended over time. Cox proportional hazards regression analysis controlling for confounders was used to investigate the association between year of surgery and two-year risk of any reoperation, any revision, dislocation, periprosthetic joint infection (PJI), venous thromboembolism (VTE), and periprosthetic fracture. Regression was stratified by three separate groups: non-obese; WHO Class I and Class II (BMI 30 to 39 kg/m2); and WHO Class III patients (BMI ≥ 40 kg/m2).Aims
Methods
The relative advantages and disadvantages of two-stage versus one-stage management of infected total hip arthroplasties are the current subject of intense debate. To understand the merits of each approach detailed information on the short and, importantly, longer-term outcomes of each must be known. The purpose of this study was to assess the long-term results of two-stage exchange arthroplasty for THAs in one of the largest series to date. We identified 331 infected THAs treated with a two-stage exchange arthroplasty between 1993 and 2021 at a single institution. Patients were excluded if they had prior treatment for infection. Mean age at reimplantation was 66 years, 38% were female, and mean BMI was 30 kg/m2. PJI diagnosis was based on the 2011 MSIS criteria. A competing risk model accounting for death was utilized. Mean follow up was 8 years. The cumulative incidence of reinfection was 7% at 1 year and 11% at 5 and 10 years. Factors predictive of reinfection included BMI>30 kg/m2 (HR 2; p=0.049), and need for a spacer exchange (HR 3.2; p=0.006). The cumulative incidence of any revision was 13% at 5 and 10 years. The cumulative incidence of aseptic revision was 3% at 1 year, 7% at 5 years, and 8% at 10 years. Dislocation occurred in 33 hips (11% at 10 years; 45% required revision). Factors predictive of dislocation were female sex (HR 2; p=0.047) and BMI<30 kg/m2 (HR 3; p=0.02). The mean HHS improved from 54 to 75 at 10 years. In this series of 331 two-stage exchange arthroplasties performed for infected hips, we found a low aseptic revision rate (8%) and a low rate of reinfection (11%) at 10 years. These long-term mechanical and infection data must be kept in mind when considering a paradigm shift to one-stage exchanges. Level of Evidence: Level III
Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term implant survivorship, risk factors, complications, and clinical outcomes of contemporary primary THAs in this difficult cohort. Our institutional total joint registry was used to identify 119 primary THAs performed in 109 patients with an angular proximal femoral deformity between 1997 and 2017. The deformity was related to previous femoral osteotomy in 85%, and developmental or metabolic disorders in 15%. 53% had a predominantly varus angular deformity. The mean age was 44 years, mean BMI was 29 kg/m2, and 59% were female. An uncemented metaphyseal fixation stem was used in 30%, an uncemented diaphyseal fixation stem in 28%, an uncemented modular body stem with metaphyseal fixation sleeve in 24%, and a cemented stem in 18%. Simultaneous corrective femoral osteotomy was performed in 18%. Kaplan-Meier survivorships and Harris hip scores were reported. Mean follow-up was 8 years. The 10-year survivorships free of femoral loosening, aseptic femoral revision, any revision, and any reoperation were 95%, 93%, 90% and 88%, respectively. Revisions occurred in 13 hips for: aseptic femoral component loosening (3), stem fracture (2), dislocation (2), aseptic acetabular loosening (2), polyethylene liner exchange (2), and infection (2). Preoperative varus angular deformities were associated with a higher risk of any revision (HR 10, p=0.03), and simultaneous osteotomies with a higher risk of any reoperation (HR 3.6, p=0.02). Mean Harris hip scores improved from 52 preoperatively to 82 at 10 years (p<0.001). In the largest series to date of primary THAs in patients with angular proximal femoral deformities, we found a good 10-year survivorship free from any revision. Varus angular deformities, particularly those treated with a simultaneous osteotomy due to the magnitude or location of the deformity, had a higher reoperation rate. Keywords: Proximal femoral deformity; dysplasia; femoral osteotomy; survivorship; revision Level of evidence: Level III, comparative retrospective cohort
Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m2 (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97).Aims
Methods
Contemporary outcomes of primary total hip arthroplasties (THAs) with highly cross-linked polyethylene (HXLPE) liners in patients with inflammatory arthritis have not been well studied. This study examined the implant survivorship, complications, radiological results, and clinical outcomes of THA in patients with inflammatory arthritis. We identified 418 hips (350 patients) with a primary diagnosis of inflammatory arthritis who underwent primary THA with HXLPE liners from January 2000 to December 2017. Of these hips, 68% had rheumatoid arthritis (n = 286), 13% ankylosing spondylitis (n = 53), 7% juvenile rheumatoid arthritis (n = 29), 6% psoriatic arthritis (n = 24), 5% systemic lupus erythematosus (n = 23), and 1% scleroderma (n = 3). Mean age was 58 years (SD 14.8), 66.3% were female (n = 277), and mean BMI was 29 kg/m2 (SD 7). Uncemented femoral components were used in 77% of cases (n = 320). Uncemented acetabular components were used in all patients. Competing risk analysis was used accounting for death. Mean follow-up was 4.5 years (2 to 18).Aims
Methods
There is a paucity of mid-term data on modular dual-mobility (MDM) constructs versus large (≥40 mm) femoral heads (LFH) in revision total hip arthroplasties (THAs). The purpose of this study was to update our prior series at 10 years, with specific emphasis on survivorships free of re-revision for dislocation, any re-revision, and dislocation. We identified 300 revision THAs performed at a single tertiary care academic institution from 2011 to 2014. Aseptic loosening of the acetabular component (n=65), dislocation (n=59), and reimplantation as part of a two-stage exchange protocol (n=57) were the most common reasons for index revision. Dual-mobility constructs were used in 124 cases, and LFH were used in 176 cases. Mean age was 66 years, mean BMI was 31 kg/m2, and 45% were female. Mean follow-up was 7 years. The 10-year survivorship free of re-revision for dislocation was 97% in the MDM cohort and 91% in the LFH cohort with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 5.2; p=0.03). The 10-year survivorship free of any re-revision was 90% in the MDM cohort and 84% in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.5; p=0.04). The 10-year survivorship free of any dislocation was 92% in the MDM cohort and 87% in the LFH cohort. There was a trend towards an increased risk of any dislocation in the LFH cohort (HR 2.3; p=0.06). In this head-to-head comparison, revision THAs using MDM constructs had a significantly lower risk of re-revision for dislocation compared to LFH at 10 years. In addition, there was a trend towards lower risk of any dislocation. Level of Evidence: IV
Cup-cage constructs are one of several methods commonly used to treat severe acetabular bone loss during contemporary revision total hip arthroplasty. The purpose of this study was to provide a long-term results of the technique with emphasis on implant survivorship, radiographic results, and clinical outcomes for both full and half cup-cage reconstructions. We identified 57 patients treated with a cup-cage reconstruction for major acetabular bone loss between 2002–2012. All patients had Paprosky Type 2B through 3B bone loss, with 60% having an associated pelvic discontinuity. Thirty-one patients received a full cup-cage construct, and 26 a half cup-cage. Mean age at reconstruction was 66 years, 75% were female, and the mean BMI was 27 kg/m2. Mean follow-up was 10 years. The 10-year cumulative incidences of any revision were 14% and 12% for the full and half cup-cage construct groups, respectively. Of the 9 revisions, 3 were for dislocation, 2 for aseptic loosening and construct failure (both were pelvic discontinuities), 1 for adverse local tissue reaction, and 1 for infection with persistent pelvic discontinuity. The 10-year cumulative incidences of revision for aseptic loosening were 4.5% and 5% for the full and half cup-cage constructs, respectively. Of the unrevised cases, incomplete and non-progressive zone 3 radiolucent lines were observed in 10% of patients in each group. Three patients experienced partial motor and sensory sciatic nerve palsies (2 in the full and 1 in the half cup-cage group). Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip scores. Full and half cup-cage reconstructions for major acetabular defects were successful at 10 years in regards to acetabular fixation without appreciable differences between the two techniques. However, zone 3 radiolucent lines were not uncommon in association with discontinuities, and dislocation continues to be a problem.
There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems. We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m2, and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized. The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up. This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI. Level of Evidence: IV
The last two decades have seen remarkable technological advances in total hip arthroplasty (THA) implant design. Porous ingrowth surfaces and highly crosslinked polyethylene (HXLPE) have been expected to dramatically improve implant survivorship. The purpose of the present study was to evaluate survival of contemporary cementless acetabular components following primary THA. 16,421 primary THAs performed for osteoarthritis between 2000 and 2019 were identified from our institutional total joint registry. Patients received one of 12 contemporary cementless acetabular designs with HXLPE liners. Components were grouped based on ingrowth surface into 4 categories: porous titanium (n=10,952, mean follow-up 5 years), porous tantalum (n=1223, mean follow-up 5 years), metal mesh (n=2680, mean follow-up 6.5 years), and hydroxyapatite (HA) coated (n=1566, mean follow-up 2.4 years). Kaplan-Meier analyses were performed to assess the survivorship free of acetabular revision. A historical series of 182 Harris-Galante-1 (HG-1) acetabular components was used as reference. The 15-year survivorship free of acetabular revision was >97% for all 4 contemporary cohorts. Compared to historical control, porous titanium (HR 0.06, 95% CI 0.02–0.17, p<0.001), porous tantalum (HR 0.09, 95%CI 0.03–0.29, p<0.001), metal mesh (HR 0.11, 95%CI 0.04–0.31, p<0.001), and HA-coated (HR 0.14, 95%CI 0.04–0.48, p=0.002) ingrowth surfaces had significantly lower risk of any acetabular revision. There were 16 cases (0.1%) of acetabular aseptic loosening that occurred in 8 (0.07%) porous titanium, 5 (0.2%) metal mesh, and 3 (0.2%) HA-coated acetabular components. 7 of the 8 porous titanium aseptic loosening cases occurred in one known problematic design. There were no cases of aseptic loosening in the porous tantalum group. Modern acetabular ingrowth surfaces and HXLPE liners have improved on historical results at the mid-term. Contemporary designs have extraordinarily high revision-free survivorship, and aseptic loosening is now a rare complication. At mid-term follow-up, survivorship of contemporary uncemented acetabular components is excellent and aseptic loosening occurs in a very small minority of patients.
The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m2 (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2).Aims
Methods
Septic arthritis of the hip often leads to irreversible osteoarthritis (OA) and the requirement for total hip arthroplasty (THA). The aim of this study was to report the mid-term risk of any infection, periprosthetic joint infection (PJI), aseptic revision, and reoperation in patients with a past history of septic arthritis who underwent THA, compared with a control group of patients who underwent THA for OA. We retrospectively identified 256 THAs in 244 patients following septic arthritis of the native hip, which were undertaken between 1969 and 2016 at a single institution. Each case was matched 1:1, based on age, sex, BMI, and year of surgery, to a primary THA performed for OA. The mean age and BMI were 58 years (35 to 84) and 31 kg/m2 (18 to 48), respectively, and 100 (39%) were female. The mean follow-up was 11 years (2 to 39).Aims
Methods
The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies, implant survivorship, and IPFF clinical outcomes. A total of 76 patients treated for an IPFF from February 1985 to April 2018 were reviewed. Prior to fracture, at the hip/knee sites respectively, 46 femora had primary/primary, 21 had revision/primary, three had primary/revision, and six had revision/revision components. Mean age and BMI were 74 years (33 to 99) and 30 kg/m2 (21 to 46), respectively. Mean follow-up after fracture treatment was seven years (2 to 24).Aims
Methods
Patients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of aseptic acetabular component loosening. However, several series have reported improved results with tantalum acetabular components. The purpose of this study was to assess implant survivorship, radiographic results, and clinical outcomes of contemporary, non-tantalum, porous acetabular components in the setting of prior pelvic radiation. We retrospectively reviewed 33 patients (38 hips) with prior therapeutic pelvic radiation between 2006 and 2016 who underwent primary THA. The mean overall pelvic radiation dose was 6300 cGy with a mean latency period to THA of 5 years. The most common acetabular component was Pinnacle (Depuy-Synthes) in 76%, followed by Trident (Stryker) in 8%, Tritanium (Stryker) in 8%, Trilogy (Zimmer-Biomet) in 5%, and G7 (Zimmer-Biomet) in 3%. Eighty-seven percent of cups were fixed with screws, of which the mean number used was 3. The mean age at primary THA was 74 years, 76% were male, and the mean BMI was 30 kg/m2. Mean follow-up was 5 years.Introduction
Methods
The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFF). Our study aimed to assess treatment methodologies, implant survivorship, and clinical outcomes of patients with IPFF. 77 patients treated for an IPFF from 1985–2017 at a single large referral center were reviewed. Prior to the fracture, at the hip/knee sites respectively 46 femurs had primary/primary, 21 had revision/primary, 3 had primary/revision and 7 had revision/revision components. Mean age and BMI were 74 years and 30 kg/m2, respectively. Mean follow-up after fracture treatment was 7 years.Introduction
Methods
Trochanteric fractures account for up to 20% of all periprosthetic fractures occurring during or after total hip arthroplasties (THAs). They are frequently managed conservatively except in cases with significant displacement. There is a paucity of literature describing the indications and results of operative or non-operative management of these fractures. 173 trochanteric fractures occurred in 171 patients, after all primary THAs performed from 1989–2017. Mean age at fracture was 64-years, with 65% being female. Mean follow-up was 7.6-years. Patient's radiographs and Harris Hip Scores (HHS) were recorded. There were 85 (49%) intraoperative and 88 postoperative fractures. Mean time from THA to fracture was 66 months for the postoperative group. 79 (46%) cases were fixed (68 intraoperative, 11 postoperative). Fixation was considered at the discretion of the surgeon. Within the 88 postoperative fractures, 30 were associated with polyethylene wear and osteolysis. 77 were initially treated conservatively and 11 were immediately fixed (8 revisions due to osteolysis, and 3 fracture fixations due to disability associated to displacement >1cm). 19 of the 30 postoperative fractures associated with polyethylene wear and osteolysis, eventually underwent revision.Background
Methods
Uncemented dual-tapered stems are a popular choice for primary total hip arthroplasty (THA). The purpose of this study was to examine long-term outcomes after primary THA utilizing a single dual-tapered stem. Utilizing our total joint registry, we retrospectively identified 1215 THAs (1055 patients) performed with an uncemented dual-tapered stem from 1998 to 2009. Mean age was 55 years, 70% were male, and mean BMI was 30 kg/m2. Mean follow-up was 10 years. Analysis included implant survivorship, clinical outcomes, and radiographic results.Background
Patients and Methods
The purpose of this multicenter, randomized clinical trial was to determine the optimal dosing regimen of tranexamic acid (TXA) to minimize perioperative blood loss for revision total hip arthroplasty (THA). Six centers prospectively randomized 155 revisions to one of four regimens: 1g of intravenous (IV) TXA prior to incision, a double dose regimen of 1g IV TXA prior to incision and 1g IV TXA during wound closure, a combination of 1g IV TXA prior to incision and 1g intraoperative topical TXA, or three doses of 1950mg oral TXA administered 2 hours preoperatively, 6 hours postoperatively, and on the morning of postoperative day one. Randomization was based upon revision subgroups to ensure equivalent group distribution, including: femur only, acetabulum only, both component, explant/spacer, and second stage reimplantation. Patients undergoing an isolated modular exchange were excluded. An Background
Methods
Pelvic discontinuity is a challenging complication. One treatment option that has garnered enthusiasm is acetabular distraction. This method obtains stability via distraction of the discontinuity and placement of an oversized socket (± augments) and elastic recoil of the pelvis. The aims of this study were to report implant survivorship, radiographic results, clinical outcomes, and complications of acetabular distraction for pelvic discontinuity in the largest series to date. We retrospectively identified all revision THAs with a Paprosky 3B defect and pelvic discontinuity between 2005 and 2017. Of the 162 patients, 32 were treated with distraction. The mean distraction achieved was 5mm (range, 3–8mm). In addition to distraction with a hemispherical cup, augments were utilized in 3 and cages in 19. The mean age at revision was 68 years with 75% female. Mean follow-up was 3 years.Introduction
Methods
Adverse local tissue reactions (ALTR) can result in devastating soft tissue and osseous destruction, while potentially increasing the risk of concomitant periprosthetic joint infection (PJI). The aims of this study were to evaluate cobalt (Co) and chromium (Cr) levels generated in simulators from metal-on-polyethylene (MoP) and ceramic-on-polyethylene (CoP) constructs, and determine their impact on native tissues and PJI risk through evaluation of human adipose-derived mesenchymal stem cells (AMSCs) and Ten hip simulator constructs were assembled with 36-mm high-offset femoral heads, highly cross-linked polyethylene liners, and titanium stems. Five constructs used CoCr femoral heads and five used ceramic. Constructs were submerged in bovine serum (BS) and run for 1,000,000 cycles. Samples of BS were collected and evaluated for CoCr concentration. Various concentrations of CoCr were chosen for further assessment of cytotoxicity and growth impact on AMSCs and Introduction
Methods
There is renewed interest in dislocation after surgical approach with popularization of the direct anterior approach. The purported advantage of both the lateral and direct anterior approaches is decreased risk of dislocation. The purpose of this study was to assess the risk of dislocation by approach following modern primary THA. All primary THAs at a single academic institution from 2010 to 2017 were analyzed through our institutional total joint registry. There were 7023 THAs including 3754 posterior, 1732 lateral, and 1537 direct anterior. Risk of dislocation was assessed against the competing risks of revision surgery and death as well as by individual patient and surgical factors including surgical approach. Risk of revision surgery was considered as a secondary outcome. Step-wise selection was utilized to develop multivariable models. Clinical outcomes were documented with the Harris Hip Score (HHS). Mean age was 63 years, 51% were female, and mean body mass index (BMI) was 30 kg/m2. Minimum follow-up was 2 years.Introduction
Methods