Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 137 - 137
1 Feb 2020
Dessinger G Argenson J Bizzozero P LaCour M Komistek R
Full Access

Introduction

Numerous fluoroscopic studies have been conducted to investigate kinematic variabilities of total knee arthroplasty (TKA). In those studies, subjects having a posterior stabilized (PS) TKA experience greater weightbearing knee flexion and posterior femoral rollback of the lateral condyle. In those same studies, subjects did experience a high incidence of variable medial condyle motion and reverse axial rotation, especially occurring when the cam engaged the post. More recently, a PS TKA was designed to accommodate both gender and ethnicity. Therefore, the objective of this study was to assess in vivo kinematics for subjects having this TKA type to determine if subjects having this PS TKA experienced more optimal knee kinematics.

Methods

Twenty-five subjects in this study were asked to perform a deep knee bend to maximum knee flexion and a step-up maneuver while under fluoroscopic surveillance. All subjects were patients of one experienced surgeon and received the same PS TKA. Using a 3D-2D registration technique, the CAD models, supplied by the sponsoring company, were superimposed over x-ray images at specified increments throughout the fluoroscopic footage. The kinematics were then analyzed to evaluate lateral anterior/posterior (LAP) and medial anterior/posterior (MAP) condyle translation as well as axial rotation of the femur with respect to the tibia.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 114 - 114
1 Mar 2017
Riviere C Girerd D Ollivier M Argenson J Parratte S
Full Access

Background

A principle of Total Knee Arthroplasty (TKA) is to achieve a neutral standing coronal alignment of the limb (Hip Knee Ankle (HKA) angle) to reduce risks of implant loosening, reduce polyethylene wear, and optimise patella tracking. Several long-term studies have questioned this because the relationship between alignment and implant survivorship is weaker than previously reported. We hypothesize standing HKA poorly predicts implant failure because it does not predict dynamic HKA, dynamic adduction moment, and loading of the knee during gait. Therefore, the aim of our study is to assess the relationship between the standing (or static) and the dynamic (gait activity) HKAs.

Methods

We performed a prospective study on a cohort of 35 patients (35 knees) who were treated with a posterior-stabilized TKA for primary osteoarthritis between November 2012 and January 2013. Three months after surgery each patient had standardized digital full-leg coronal radiographs and was classified as neutrally aligned TKA (17 patients), varus aligned (9 patients), and valgus aligned (4 patients) (figure 1). Patients then performed a gait analysis for level walking and dynamic HKA and adduction moment during the stance phase of gait were measured.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 24 - 24
1 Jan 2016
Argenson J Parratte S Flecher X Aubaniac J
Full Access

Treatment of osteoarthritis of the knee remains a challenging problem since the evolution of the disease may be different in each compartment of the knee, as well as the state of the ligaments. Total knee arthroplasty may provide a reliable long-lasting option but do not preserve the bone stock. In another hand, compartmental arthroplasty is a bone and ligament sparing solution to manage limited osteoarthritis of the knee affecting the medial, lateral or the patello-femoral compartment.1, 2, 3

Patient's selection and surgical indication are based on the physical examination and on the radiological analysis including full-length x-rays and stress x-rays. Clinical experience has shown the need for high flexion in patients who have both high flexibility and a desire to perform deep flexion.

Additionally the shape differences related to anatomy or the patient expectations after the surgery may also affect the surgeon decision. 4

The limited incision into the extensor mechanism allows a quicker recovery which represents a functional improvement for the patient additionally to the cosmetic result. A dedicated physiotherapy starting on the following day allowing weight bearing exercises protected by crutches and focusing on early mobilization and range of motion combined to a multimodal pain management approach is critical despite the type of individualized solution chosen for the patient knee. 5

Since bony landmarks may be different form a patient to another one as well as anatomical shapes, several tools have been developed in order to provide the surgeons an assisted tool during the surgery adapted to each knee, this include navigation, patient specific instrumentation and robotic surgery.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 25 - 25
1 Jan 2016
Argenson J Flecher X Parratte S Aubaniac J
Full Access

Improving the adaptation between the implant and the patient bone during total hip arthroplasty (THA) may improve the survival of the implant. This requires a perfect understanding of the tridimensional characteristics of the patient hip. The perfect evaluation of the tridimensional anatomy of the patient hip can be done pre-operatively using X-rays and CT-scan. All patients underwent a standard x-rays evaluation in the same center according to the same protocol. Pre-operatively, the frontal analysis of the hip geometry was performed and the optimal center of rotation, CCD angle, neck length and lever arm was analyzed to choose the optimal solution for proper balance of the hip in order to obtain adequate range of motion, appropriate leg length, and correct tension of the abductors muscles. Standard or lateralized monoblock stems can be valid or modular neck shape can be choosen among 9 available shape. These 9 frontal shapes are available in standard, anteverted or retroverted shapes, leading to 27 potential neck combinations. In case of important hip deformation, a custom implant can be used in order to balance the extra-medullar geometry without compromising the intra-medullary adaptation of the stem.

We prospectively included 209 hips treated in our institution with total hip arthroplasty performed using a supine Watson-Jones approach and the same anatomic stem. The mean patient age was 68 years and the mean BMI 26 Kg/m². Intra-operatively the sagittal anatomy of the hip was analyzed and standard, ante or retro modular necks were tested for the frontal shape defined pre-operatively.

According to the pre-operative frontal planning, non-standard necks were required in 24 % of the cases to restore the anatomy of the hip. Intra-operatively, a sagittal correction using anteverted neck was required in 5% of the cases and retroverted necks in 18% of the cases. Harris hip score improved from 56 to 95 points at min. 5 year follow-up. No leg length discrepancy greater than 1 cm was observed. Restoration of the lever arm (mean 39.3 mm, range 30 to 49 mm) and of the neck length (55.2, range 43 to 68 mm) was adapted for 95% compared to the non operate opposite side. Disturbed anatomy like in DDH or post-traumatic cases may require additional solutions to balance the hip such combined osteotomy or customized stem and neck.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 8 - 8
1 Dec 2013
Argenson J Ollivier M Parratte S Flecher X Aubaniac J
Full Access

Introduction:

Recent studies have concluded that gender influences hip morphology at the time of surgery as well as dysplastic development of the hip. This may lead to a particular choice of implant including stem design and/or neck modularity. In this study we hypothesized that not only gender but also morphotype and etiology (primary osteoarthritis versus aseptic osteonecrosis) may be a significant factor to predict the anatomy of the hip at the time of total hip arthroplasty (THA).

Methods:

We reviewed 690 patients undergoing THA for primary arthritis (OA) or avascular osteonecrosis (AVN) between April 2000 and June 2005 and stratified each into three groups based on their anatomic constitution: endomorph (EN), ectomorph (ECT), or mesomorph (ME) (determined by the ratio: pelvic width/total leg length measured on full-length X-rays). Two independent observers measured twice four parameters on preoperative CT scan: neck-shaft-angle angle (NSA), femoral offset value (FO), helitorsion (Ht) value and femoral neck anteversion (Av).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 137 - 137
1 Sep 2012
Parratte S Lesko F Zingde S Anderle M Mahfouz M Komistek R Argenson J
Full Access

Introduction

Previous fluoroscopic studies compared total knee arthroplasty (TKA) kinematics to normal knees. It was our hypothesis that comparing TKA directly to its non-replaced controlateral knee may provide more realistic kinematics information. Using fluoroscopic analysis, we aimed to compare knee flexion angles, femoral roll-back, patellar tracking and internal and external rotation of the tibia.

Material and methods

15 patients (12 women and 3 men) with a mean age of 71.8 years (SD=7.4) operated by the same surgeon were included in this fluoroscopic study. For each patient at a minimum one year after mobile-bearing TKA, kinematics of the TKA was compared to the controlateral knee during three standardized activities: weight-bearing deep-knee bend, stair climbing and walking. A history of trauma, pain, instability or infection on the non-replaced knee was an exclusion criteria. A CT-scan of the non-replaced knee was performed for each patient to obtain a 3-D model of the knee. The Knee Osteoarthitis Outcome Score (KOOS) was also recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 39 - 39
1 Sep 2012
Leszko F Zingde S Argenson J Dennis D Wasielewski R Mahfouz M Komistek R De Bock T
Full Access

Anterior knee pain is one of the most frequently reported musculoskeletal complaints in all age groups. However, patient's complaints are often nonspecific, leading to difficulty in properly diagnosing the condition. One of the causes of pain is the degeneration of the articular cartilage. As the cartilage deteriorates, its ability to distribute the joint reaction forces decreases and the stresses may exceed the pain threshold. Unfortunately, the assessment of the cartilage condition is often limited to a detailed interview with the patient, careful physical examination and x-ray imaging. The X-ray screening may reveal bone degeneration, but does not carry sufficient information of the soft tissues' conditions. More advanced imaging tools such as MRI or CT are available, but these are expensive, time consuming and are only suitable for detection of advanced arthritis. Arthroscopic surgery is often the only reliable option, however due to its semi-invasive nature, it cannot be considered as a practical diagnostic tool. However, as the articular cartilage degenerates, the surfaces become rougher, they produce higher vibrations than smooth surfaces due to higher friction during the interaction. Therefore, it was proposed to detect vibrations non-invasively using accelerometers, and evaluate the signals for their potential diagnostic applications.

Vibration data was collected for 75 subjects; 23 healthy and 52 subjects suffering from knee arthritis. The study was approved by the IRB and an Informed Consent was obtained prior to data collection. Five accelerometers were attached to skin around the knee joint (at the patella, medial and lateral femoral condyles, tibial tuberosity and medial tibial plateau). Each subject performed 5 activities; (1) flexion-extension, (2) deep knee bend, (3) chair rising, (4) stair climbing and (5) stair descent. The vibration and motion components of the signals were separated by a high pass filter. Next, 33 parameters of the signals were calculated and evaluated for their discrimination effectiveness (Figure 1). Finally the pattern recognition method based on Baysian classification theorem was used for classify each signal to either healthy or arthritic group, assuming equal prior probabilities.

The variance and mean of the vibration signals were significantly higher in the arthritic group (p=2.8e-7 and p=3.7e-14, respectively), which confirms the general hypothesis that the vibration magnitudes increase as the cartilage degenerates. Other signal features providing good discrimination included the 99th quantile, the integral of the vibration signal envelope, and the product of the signal envelope and the activity duration. The pattern classification yielded excellent results with the success rate of up to 92.2% using only 2 features, up to 94.8% using 3 (Figure 2), and 96.1% using 4 features.

The current study proved that the vibrations can be studied non-invasively using a low-cost technology. The results confirmed the hypothesis that the degeneration of the cartilage increases the vibration of the articulating bones. The classification rate obtained in the study is very encouraging, providing over 96% accuracy. The presented technology has certainly a potential of being used as an additional screening methodology enhancing the assessment of the articular cartilage condition.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 7 - 7
1 Sep 2012
Argenson J
Full Access

Background

Acetabular component malpositioning during hip arthroplasty increases the risk of dislocation, reduces range of motion and can be responsible for early wear and loosening. There have been numerous reports on the optimal orientation of the acetabular component in total hip arthroplasty (THA). Lewinnek et al recommended an abduction angle of 40°±10° and an anteversion of 15°±10° for cup alignment in THA. The purpose of the in vivo study was to compare computer assisted acetabular component insertion versus free-hand placement. The goal of the cadaveric study was to compare in vitro a new tool using ultrasound with the standard percutaneous manual methods for the anterior pelvic plane registration during computer-assisted total hip arthroplasty.

Methods

A controlled randomized matched prospective study was performed in two groups of 30 patients. In the first group, cup positioning was assisted by an imageless computer assisted orthopaedics system, based on Bone Morphingâ (CAOS+ group). In the control group, a free-hand cup placement was performed (CAOS- group). A same cementless cup has been used in the two groups. All the patients were operated by the same surgeon through an anterolateral approach. Cup anteversion and abduction angles were measured on three-dimensional CT-scan reconstruction postoperatively for each patient by an independent observer with special cup evaluation software. In vitro, four clinicians were asked to register ten times in a randomly change order the anterior pelvic plane landmarks in four different acquisition conditions: a cutaneous acquisition, a draped cutaneous acquisition, ultrasound acquisition and a direct bone acquisition on two cadavers. The mean and standard deviation of error for each anterior pelvic plane acquisition method were expressed as rotation and tilt about the relevant reference plane and compared.