Periprosthetic femoral fracture (PFF) following primary total hip arthroplasty (THA) is of raising concern with the aging of the population. The aim of this retrospective study was to assess the incidence of early PFF associated with Charnley- Kerboull (CK) stems cemented line-to-line according to the “French paradox” principles through the anterior approach (AA) in patients older than 70 years old. This monocentric study involved 25 surgeons with various level of experience. From a prospectively collected database, all CK stems (AmisK®, Medacta, Castel San Pietro, Switzerland) done consecutively from January 2018 to May 2022 through the AA in patients older than 70 years were included. The measured parameters included canal flare index (CFI), morphological cortical index (MCI), canal-calcar ratio (CCR), ilium-ischial ratio (IIR), ilium overhang, and anterior superior iliac spine (ASIS) to greater trochanter distance. Dorr classification was also recorded. A total of 416 CK stems performed by 25 surgeons were included. All patients had a minimal 3-month follow-up. The mean age was 77.4 years, and the mean BMI was 25.3 kg/m2. According to the Dorr classification 240 hips were of Dorr type A, 144 Dorr type B, and 2 Dorr type C. Mean CFI, MCI, CCR, IIR and ASIS-GT were 3.8, 0.5, 2.8, 2.5, and 101mm, respectively. Amongst the 416 THAs, one (0.24%; 95% CI 0.20 – 0.28%) early PFF Vancouver type B2 fracture that occurred 24 days postoperatively was observed. This study demonstrated that CK stems cemented according to the “French Paradox” were associated with an extremely low rate of early PFF in patients over 70 years. The observed results are better than those reported with uncemented or taper slip cemented stems. Longer follow-up is warranted to evaluate further rate of fracture that may occur during the bone remodeling process around the femoral component.
Conventional cemented acetabular components are
reported to have a high rate of failure when implanted into previously
irradiated bone. We recommend the use of a cemented reconstruction
with the addition of an acetabular reinforcement cross to improve
fixation. We reviewed a cohort of 45 patients (49 hips) who had undergone
irradiation of the pelvis and a cemented total hip arthroplasty
(THA) with an acetabular reinforcement cross. All hips had received
a minimum dose of 30 Gray (Gy) to treat a primary nearby tumour
or metastasis. The median dose of radiation was 50 Gy (Q1 to Q3:
45 to 60; mean: 49.57, 32 to 72). The mean follow-up after THA was 51 months (17 to 137). The cumulative
probability of revision of the acetabular component for a mechanical
reason was 0% (0 to 0%) at 24 months, 2.9% (0.2 to 13.3%) at 60
months and 2.9% (0.2% to 13.3%) at 120 months, respectively. One
hip was revised for mechanical failure and three for infection. Cemented acetabular components with a reinforcement cross provide
good medium-term fixation after pelvic irradiation. These patients
are at a higher risk of developing infection of their THA. Cite this article:
The purpose of this study was to define immediate post-operative ‘quality’ in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.