Defining optimal coronal alignment in Total Knee Replacement (TKR) is a controversial and poorly understood subject. Tibial bone density may affect implant stability and functional outcomes following TKR. Our aim was to compare the bone density profile at the implant-tibia interface following TKR in mechanical versus kinematic alignment. Pre-operative CT scans for 10 patients undergoing medial unicompartmental knee arthroplasty were obtained. Using surgical planning software, tibial cuts were made for TKR with 7 degrees posterior slope and either neutral (mechanical) or 3 degrees varus (kinematic) alignment. Signal intensity, in Hounsfield Units (HU), was measured at 25,600 points throughout an axial slice at the implant-tibia interface and density profiles compared along defined radial axes from the centre of the tibia towards the cortices (Hotelling's t-squared and paired t-test).Background
Methods
Accurate measurement of knee motion is necessary for assessment of natural joint function and in the diagnosis of pathology. In particular, precise knowledge of natural knee mechanics provides useful metrics for comparison to knee function following total knee arthroplasty (TKA). Reported measurements of natural knee kinematics during activities of daily living are rare, and often do not include both tibiofemoral (TF) and patellofemoral (PF) articulations. What's more, most studies record knee motion of younger subjects that are not necessarily representative of the age range associated with degenerative changes and TKA. The purpose of this study was to measure TF and PF kinematics of healthy older adults as they performed activities of daily living, including tasks considered more demanding for the knee [1]. High speed stereo radiography (HSSR) was used to measure the kinematics of the PF and TF joints. HSSR utilizes two views of the knee to capture 3D sub-mm measurements accurate to within ±0.15 mm in translation and ±0.41° in rotation [2]. Eight healthy subjects (4M/4F, 64.4±8.2 years, BMI: 27.6±4.8 kg/m2) performed six activities of daily living: seated knee extension, lunge, chair rise, gait, pivot and step down (Figure 1). The 3D geometry of the femur, tibia, and patella of each subject was reconstructed from CT and used to track bone motions using Autoscoper (Brown University, Providence RI). Motion of the tibia and patella were reported relative to a coordinate system centered in the posterior condyles of the femur [3]. Average range of motion (ROM) for each DOF was calculated as the difference between the maximum and the minimum value and averaged across the subjects for each activity.Introduction
Methods
Patellar resurfacing affects patellofemoral (PF) kinematics, contact mechanics, and loading on the patellar bone. Patients with total knee arthroplasty (TKA) often exhibit adaptations in movement patterns that may be linked to quadriceps deficiency and the mechanics of the reconstructed knee [1]. Previous comparisons of PF kinematics between dome and anatomic resurfacing have revealed differences in patellar sagittal plane flexion [2], but further investigation of PF joint mechanics is required to understand how these differences influence performance. The purpose of this study was to compare PF mechanics between medialized dome and medialized anatomic implants using subject-specific computational models. A high-speed stereo radiography (HSSR) system was used to capture 3D sub-mm measurement of bone and implant motion [3]. HSSR images were collected for 10 TKA patients with Attune® (DePuy Synthes, Warsaw, IN) posterior-stabilized, rotating-platform components, 5 with medialized dome and 5 with medialized anatomic patellar components (3M/7F, 62.5±6.6 years, 2.2±0.6 years post-surgery, BMI: 26.2±3.5 kg/m2), performing two activities of daily living: knee extension and lunge (Figure 1). Relative motions were tracked using Autoscoper (Brown University, Providence, RI) for implant geometries obtained from the manufacturer. A statistical shape model was used to predict the patella and track motions [4]. Subject-specific finite element models of the experiment were developed for all subjects and activities [5]. The model included implant components, patella, quadriceps, patellar tendon, and medial and lateral PF ligaments (Figure 2a). While tibiofemoral kinematics were prescribed based on experimental data, the PF joint was unconstrained. A constant 1000N quadriceps load was distributed among four muscle groups. Soft tissue attachments and pre-strain in PF ligaments were calibrated to match experimental kinematics [5]. Model outputs included PF kinematics, patellar and contact force ratios, patellar tendon angle, and moment arm.Introduction
Methods
Modularity in total knee arthroplasty, particularly in revisions, is a common method to fit the implants to a patient's anatomy when additional stability or fixation is needed. In such cases, it may be necessary to employ multiple points of modularity to better match the anatomy. Taper junction strength at each of these levels is critical to maintain the mechanical stability of the implant and minimize micromotion. This effect of distributed assembly loads through multiple tapers and the resulting strength of the construct have not been previously evaluated on this revision tibial implant. The purpose of this study was to evaluate the possible dissipation of impaction force through multiple taper connections as compared to a single connection. Two different constructs representative of modular implants were studied: a construct with a single axial taper connection (Group A; representing implant-stem) was compared to a construct with an adaptor that included two, offset, modular taper connections (Group B; representing implant-adapter-stem). For Group A, the stem taper was assembled and impacted through the stem. For Group B, the two tapers of the adapter and stem were hand assembled with the mating components and impacted simultaneously through the stem. Assembly load for each construct was recorded. As shown in Figure 1, the constructs were then fixed in a mechanical test frame and an axial distraction force was applied to the end of the stem at a constant displacement rate of 0.075 mm/sec until taper separation or mechanical failure occurred. Force and displacement data were recorded at 50 Hz. Disassembly force was normalized to assembly force for each component. Minitab software was used to analyze the data using a t-test.Objectives
Methods
Total elbow arthroplasty (TEA) has been shown to be a treatment option for elderly patients with complex distal humeral fractures and osteoporotic bone. The published results have often included rheumatoid patients who traditionally would be expected to do well from elbow arthroplasty. Only short-term results have been published using this technique in non-rheumatoid patients. The current study contains the largest number and longest follow-up of non-rheumatoid patients whose fractures have been treated with a non-custom TEA. In total there were 26 patients, mean age 72 years, 22 female and 4 male, 25% dominant arm. The mean follow-up was of 5 years. There was 1 case of loosening, 1 radial nerve palsy and 2 cases of heterotrophic ossification. At final review the mean range of flexion/extension was 97.5 degrees and the mean range of pronation/supination was 151.75 degrees. The mean Mayo Elbow Performance score was 92. We would suggest that TEA provides a very satisfactory outcome in elderly patients with complex distal humeral fractures, the benefit of which can be observed at a mean of 5 years.