Advertisement for orthosearch.org.uk
Results 1 - 20 of 190
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 81 - 81
1 Mar 2021
Yaghmour KM Hossain F Konan S
Full Access

Abstract. Objective. In this systematic review we aim to compare wound complication rates from Negative Pressure Wound Therapy (NPWT) to dry sterile surgical dressings in primary and revision total knee arthroplasty (TKA). Methods. A search was performed using PubMed, Embase, Science Direct, and Cochrane Library. Eligible studies included those investigating the use of NPWT in primary and revision TKA. Exclusion criteria included studies investigating NPWT not related to primary or revision TKA; studies in which data relating to NPWT was not accessible; missing data; without an available full text, or not well reported. We also excluded studies with poor scientific methodology. All publications were limited to the English language. Abstracts, case reports, conference presentations, and reviews were excluded. Welch independent sample t-test was used for the statistical analysis. Results. Our review identified 11 studies evaluating 1,414 patients. Of the 1,181 primary TKA patients analysed (NPWT = 416, surgical dressing = 765), the overall wound complication rates in patients receiving NPWT ranged from 0% – 63% (Median 7.30%, SD ± 21.44) This is in comparison to complication rates of 2.8% – 19% (Median 6.50%, SD ± 6.59) in the dry dressing group. The difference in complication rates between the two groups was not statistically significant (p =0.337). In the revision TKA cohort of 279 patients (NPWT group = 128, dry dressing group = 151), the overall wound complication rates in the NPWT group ranged between 6.7% – 12% (Median 9.80%, SD ± 2.32) vs 23.8% – 30% (Median 26.95%, SD ± 2.53) in the dry dressing group. This difference was statistically significant (p<0.001). Conclusion. NPWT dressing demonstrated statistically significant reduction in wound complication rates when used in revision TKA but not primary TKA when compared to dry sterile dressings. This is probably due to higher wound related risks encountered with revision TKA surgery compared to primary TKA surgery. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 48 - 48
4 Apr 2023
Yang Y Li Y Pan Q Wang H Bai S Pan X Ling K Li G
Full Access

Treatment for delayed wound healing resulting from peripheral vascular diseases and diabetic foot ulcers remain a challenge. A novel surgical technique named Tibial Cortex Transverse Transport has been developed for treating peripheral ischaemia, with encouraging clinical effects. However, its underlying mechanisms remain unclear. In present study, we aimed to explore the wound healing effects after undergoing this novel technique via multiple ways. A novel rat model of Tibial Cortex Transverse Transport was established with a designed external fixator and effects on wound healing were investigated. All rats were randomized into 3 groups, with 12 rats per group: sham group (negative control), fixator group (positive control) and Tibial Cortex Transverse Transport group. Laser speckle perfusion imaging, vessel perfusion, histology and immunohistochemistry were used to evaluate the wound healing processes. Gross and histological examinations showed that Tibial Cortex Transverse Transport technique accelerated wound closure and enhanced the quality of the newly formed skin tissues. In Tibial Cortex Transverse Transport group, HE staining demonstrated a better epidermis and dermis recovery, while immune-histochemical staining showed that Tibial Cortex Transverse Transport technique promoted local collagen deposition. Tibial Cortex Transverse Transport technique also benefited to angiogenesis and immunomodulation. In Tibial Cortex Transverse Transport group, blood flow in the wound area was higher than that ofother groups according to laser speckle imaging with more blood vessels observed. Enhanced neovascularization was seen in the Tibial Cortex Transverse Transport group with double immune-labelling of CD31 and α-SMA. The M2 macrophages at the wound site in the Tibial Cortex Transverse Transport group was also increased. Tibial cortex transverse transport technique accelerated wound healing through enhanced angiogenesis and immunomodulation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 69 - 69
2 Jan 2024
Dintheer A Jaeger P Hussien A Snedeker J
Full Access

Extracellular matrix (ECM) mechanical cues guide healing in tendons. Yet, the molecular mechanisms orchestrating the healing processes remain elusive. Appropriate tissue tension is essential for tendon homeostasis and tissue health. By mapping the attainment of tensional homeostasis, we aim to understand how ECM tension regulates healing. We hypothesize that diseased tendon returns to homeostasis only after the cells reach a mechanically gated exit from wound healing. We engineered a 3D mechano-culture system to create tendon-like constructs by embedding patient-derived tendon cells into a collagen I hydrogel. Casting the hydrogel between posts anchored in silicone allowed adjusting the post stiffness. Under this static mechanical stimulation, cells remodel the (unorganized) collagen representing wound healing mechanisms. We quantified tissue-level forces using post deflection measurements. Secreted ECM was visualized by metabolic labelling with non-canonical amino acids, click chemistry and confocal microscopy. We blocked cell-mediated actin-myosin contractility using a ROCK inhibitor (Y27632) to explore the involvement of the Rho/ROCK pathway in tension regulation. Tissue tension forces reached the same homeostatic level at day 21 independent of post compliance (p = 0.9456). While minimal matrix was synthesized in early phases of tissue formation (d3-d5), cell-deposited ECM was present in later stages (d7-d9). More ECM was deposited by tendon constructs cultured on compliant (1Nm) compared to rigid posts (p = 0.0017). Matrix synthesized by constructs cultured on compliant posts was less aligned (greater fiber dispersion, p = 0.0021). ROCK inhibition significantly decreased tissue-level tensional forces (p < 0.0001). Our results indicate that tendon cells balance matrix remodeling and synthesis during tissue repair to reach an intrinsically defined “mechanostat setpoint” guiding tension-mediated exit from wound healing towards homeostasis. We are identifying specific molecular mechanosensors governing tension-regulated healing in tendon and investigate the Rho/ROCK system as their possible downstream pathway


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 95 - 95
17 Apr 2023
Gupta P Butt S Galhoum A Dasari K
Full Access

Between 2016–2019, 4 patients developed hip infections post-hemiarthroplasty. However, between 2020–2021 (Covid-19 pandemic period), 6 patients developed hip infections following hip hemiarthroplasty. The purpose of the investigation is to establish the root causes and key learning from the incident and use the information contained within this report to reduce the likelihood of a similar incident in the future. 65 patients presented with a neck of femur fracture during Covid-19 pandemic period between 2020–2021, 26 had hip hemiarthroplasty of which 6 developed hip infections. Medical records, anaesthetic charts and post-hip infections guidelines from RCS and NICE were utilised. Proteus, Enterococci and Strep. epidermis were identified as the main organisms present causing the hip infection. The average number of ward moves was 4 with 90% of patients developing COVID-19 during their hospital stay. The chance of post-operative wound infection were multifactorial. Having had 5 of 6 patients growing enterococci may suggest contamination of wound either due to potential suboptimal hygiene measures, inadequate wound management /dressing, potential environmental contamination if the organisms (Vancomycin resistant enterococci) are found to be of same types and potential hospital acquired infection due to inadequate infection control measures or suboptimal hand hygiene practices. 3 of the 5 patients grew Proteus, which points towards suboptimal hygiene practices by patients or poor infection control practices by staff. Lack of maintenance of sterility in post op wound dressings alongside inexperience of the handling of post-operative wound in non-surgical wards; multiple ward transfers exceeding the recommended number according to trust guidelines especially due to pandemic isolation measures and COVID-19 infection itself had resulted in an increased rate of hip infections during the COVID-19 pandemic. Multidisciplinary team education and planned categorisation and isolation strategy is essential to minimise the rate of further hip infections during the pandemic period in future


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 98 - 98
1 Mar 2021
Yaghmour KM Hossain F Konan S
Full Access

Abstract. Objective. In this systematic review we aim to analyse the economical impact of using Negative Pressure Wound Therapy (NPWT) in primary total knee arthroplasty (TKA). Methods. Four medical electronic databases were searched. Eligible studies included those investigating the costs of NPWT in primary TKA. Exclusion criteria included studies investigating cost of NPWT not related to primary TKA. We also excluded studies with poor scientific methodology. We retrieved and analysed data on dressing costs and hospital length of stay (LOS). Results. Three studies (359 patients) reported on dressing and associated health care costs, and two further studies (330 patients) reported on hospital LOS in primary TKA. The cost of NPWT ranged between £125 and £196; with an average cost of £155, compared to £23 for the regular surgical dressing. The hospital LOS in NWPT patients ranged from 1.9 – 3.8 days, while LOS in patients managed with regular surgical dressing ranged between 2.3 – 4.7 days. The hospital LOS accounted for delayed discharge due to wound complications. Any extended LOS secondary to medical comorbidities or for other reasons were not included here. Conclusion. Our pooled analysis found a decrease in hospital LOS from wound related problems when using NWPT instead of regular dressings after accounting for other variables responsible for LOS. If the mean cost of overnight inpatient hospital stay for elective TKA is estimated as £275, the range of overnight admission cost for one TKA patient would be £522 - £1045 when NPWT dressing is used, and £632.5 - £1292 when using regular dressings. The cost savings from reduced LOS amounts to £110 - £247 per patient when NPWT is used. We hypothesize that in primary TKA patients with high risk of wound related problems that may delay discharge from hospital, there may be an overall cost saving when using NWPT dressings. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 25 - 25
1 Nov 2018
Peixoto R Zeugolis D
Full Access

A suitable wound closure is an indispensable requirement for an uncomplicated and expedient recovery after an abdominal surgery. The closure technique will have a great impact on the healing process of the wound. Surgical complications, such as wound dehiscence (sometimes associated with evisceration), infection, hernia, nerve injury and incisional pain are very common in the postoperative period of an abdominal surgery. Besides, although their development can be promoted by other risk factors like age, sex, lifestyle, diet, health condition, the closure method can also influence the emergence of these undesirable complications. For this reason, and having the wellbeing and quality of life of the patients in mind, particularly high-risk patients, a closure system consisting of anchors applied on either side of the wound that aims to reduce the tension caused on the surrounding tissues of a wound and, consequently, decrease the risk of herniation was evaluated in a pilot animal study and compared with the traditional suture approach


To describe clinical situations for use of modified VAC in POC based on: diagnosis, comorbidities, BMI, wound size in cm, days following trauma when VAC was first applied, total duration of uninterrupted use, frequency of change, settings, bacterial growth, outcomes. To report the outcomes of mVAC use in POC within 6 months to help improve and standardize its application in the institution. This study involves data gathering from inpatients handled by orthopedic surgeons in training and subspecialty rotations in POC. The data collected are highly dependent on the doctors-in-charge's complete charting, thorough reporting and accurate documentation. Modified Vacuum Assisted Closure (mVAC) is used frequently in this study and is defined as a form of revised, adapted and reformed use of VAC based on available materials in the involved institution. The materials that are included are, but not limited to the following: sterile Uratex™ blue foam, nasogastric or suction tubing, phlegm suction machine, Bactigras™ and Opsite™ or Ioban™. A total of 58 patients were included in the study. The average age of the population was 35 and are predominantly male. The most common mechanism of injury was motorcycle accident and 37 of the patients were diagnosed with an open fracture of the lower extremity with open tibia fractures (22) being the most common. Average wound area measured was 24.12 cm. 3. All patients yield a bacteria growth with e. coli being the most frequent. Average during of uninterrupted use was 39 days. Of the 58 included in the study, 8 patients underwent STSG, 2 had a flap coverage surgery, 4 patients eventually underwent amputation and 33 with complete resolution of soft tissue defect after conversion to biologic dressing post-mVAC. The rest of the population were still ongoing mVAC at the end of the study. mVAC is an alternative temporary medium for soft tissue coverage for cases with or without concomitant fractures. mVAC promotes removal of exudate from the wound, supports wound apposition and granulation bed proliferation. Usage mVAC helps prepare for skin coverage procedure and on some cases leads to full resolution of defect


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 67 - 67
1 Dec 2020
Debnath A Rathi N Suba S Raju D
Full Access

Introduction. Intraarticular calcaneal fractures often need open reduction and internal fixation (ORIF) with plate osteosynthesis. The wound complication is one of the common problems encountered following this and affects the outcome adversely. Our study was done to assess how far postoperative slab/cast can avert wound complications. Methods. Out of 42 patients with unilateral intraarticular calcaneal fractures, 20 were offered postoperative slab/cast and this was continued for six weeks. The remaining 22 patients were not offered any plaster. All patients were followed-up for two years. Results. The incidence of wound dehiscence was 2 in the plaster group as well as 8 in the non-plaster group and this was statistically significant (p = 0.02). Also, significantly lower heel widening was reported in the plaster group (p = 0.03). Although, there was no significant difference in the patient-reported outcome (Maryland Foot Score) and the incidence of pain between the two groups, the occurrence of neurological deficit following surgery and the postoperative range of movements were comparable in these two groups. Conclusion. Thus, it may be concluded that postoperative plaster application for the initial six weeks could be a low-cost yet effective way to reduce wound complications following plate osteosynthesis in intraarticular calcaneal fractures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 47 - 47
1 Aug 2013
Siddiqui M Bidaye A Baird E Jones B Stark A Abu-Rajab R Anthony I Ingram R
Full Access

We compared the postoperative wound discharge rates and 3 months clinical results of three types of wound closure and dressing – 2-octylcyanoacrylate with Opstie (G+O), 2-octylcyanoacrylate with Tegaderm (G+T), and Opsite without 2-octylcyanoacrylate (O) in patients having primary total hip arthroplasty. We randomised 141 patients scheduled for primary total hip arthroplasty into 3 arms of this study- G+O, G+T, or O. The extent of wound discharge was recorded on a diagrammatic representation of the dressing in situ on paper and graded each day. Dressings were left in-situ provided the extent of wound discharge allowed for this. The patient was clinically reviewed at 3 months to assess their scar length, cosmesis, scar discomfort, and evidence of superficial or deep wound sepsis. A greater number of patients dressings remained dry on day 1 postoperatively in the two groups with 2-octylcyanoacrylate compared to the no glue group p=0.001. G+T group had a significantly lower proportion of patients with increased leakage of wounds on 2. nd. postoperative day p=0.044. At 3 months review, there was no statistical difference in the Hollander score or scar discomfort. In patients who have had primary total hip arthroplasty, usage of 2-octylcyanoacrylate for wound closure along with Tegaderm dressing reduces wound discharge. The same effect is not noted in glue with Opsite group. Whilst dressing changes required in the non-glue group compared from the two glue groups did not reach statistical significance, this may have clinical relevance for patients and nursing staff. No effect on postoperative length of stay, or wound complications was noted


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 50 - 50
1 Apr 2018
Hafez M Cameron R Rice R
Full Access

Background. Surgical wound closure is not the surgeon”s favorite part of the total knee arthroplasty (TKA) surgery however it has vital rule in the success of surgery. Knee arthoplasty wounds are known to be more prone to infection, breakdown or delayed healing compared to hip arthroplasty wounds, and this might be explained by the increased tensile force applied on the wound with knee movement. This effect is magnified by the enhanced recovery protocols which aim to obtain high early range of movement. Most of the literature concluded that there is no difference between different closure methods. Objectives. We conducted an independent study comparing the complication rate associated with using barbed suture (Quill-Ethicon), Vicryl Rapide (polyglactins910-Ethicon) and skin staples for wound closure following TKA. Study Design & Methods. Retrospective study where the study group included all the patients admitted to our unit for elective primary knee arthroplasty in 2015, we excluded patients admitted for partial knee arthroplasty, revision knee arthroplasty or arthroplasty for treatment of acute trauma due to the relatively higher complication rates. All the patients notes were reviewed to identify wound related problems such as wound dehiscence, wound infection and delayed healing (defined as delayed wound healing more than 6 weeks). Results. 327 patients were included in this study; 151 in Quill group, 99 in staples group and 77 in the last group where the wound closed with Rapide. We identified 9 (5.9%) cases of wound dehiscence in the Quill group, 3 cases of wound dehiscence in each of other two groups (3.8%) with Rapide and (3%) with staples. On the other hand superficial wound infection was higher with staples with 6 (6%) cases of wound infection compared to the other groups, wound infection occurred in 2 patients (2.5%) with Rapide and 5 patients (3.3%) in the Quill”s group. Most of the delayed wound healing happened after using Quill where it is reported in 5 patients (3.3%) and the lowest was in staples group with 1 patient (1%) and slightly higher percentage in Rapide group 2 patients (2.5%). The total figure of wound related problems was the highest in Quill”s group with 19 reported cases (12.5%), lower in staples” group with 10 cases (1.1%) and the lowest in Rapide”s group with 7 cases (9%). Conclusions. Our study showed different results to the reported literature suggesting that each closure method has its own advantages and disadvantages. Quill is quick, knotless and absorbable but on the other side it is significantly more expensive than other alternatives and it is associated with the highest complication rates. On the other hand Rapide is cheap absorbable alternative with the lowest percentage of wound problems but on the negative side it is time consuming. Finally staples method is the quickest, relatively cheap and rarely associated with wound dehiscence but it is not absorbable which might cause inconvenience to patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 95 - 95
1 Nov 2018
Järvinen T
Full Access

CAR (CARSKNKDC) is a systemically administered wound-homing peptide that specifically recognizes angiogenic blood vessels and extravasates into sites of injury. CAR peptide requires heparan sulfate proteoglycans (HSPGs) for its cell penetrating activity. Syndecan-4 (SDC4) is a HSPG and binding to it triggers the wound re-epithelialization process. We have discovered that CAR peptide has the inherent ability to promote wound healing; wounds close and re-epithelialize significantly faster in CAR treated mice than in control groups (PBS and mutant peptide, i.e. mCAR injections). To delineate the molecular mechanism by which CAR accelerates wound healing, we focused on the requirement of HSPG binding for CAR peptide function. We demonstrate that CAR peptide endocytosis and its stimulation of keratinocyte cell migration are both dependent on SDC4. Finally, we show that the systemic administration of CAR peptide stimulates wound re-epithelialization only in WT mice, but not in SDC4 knockout (KO) mice. As SDC4 has very restricted expression in skin wounds, we propose that CAR peptide activates SDC4 function to promote re-epithelialization. CAR peptide may provide an entirely new way of enhancing wound healing, and perhaps tissue regeneration in general. This therapeutic approach is systemic, yet target organ- and cell- specific, and dependent on the naturally occurring SDC4 dependent migratory pathway that is crucial for tissue regeneration


Bone & Joint Research
Vol. 6, Issue 4 | Pages 231 - 244
1 Apr 2017
Zhang J Yuan T Zheng N Zhou Y Hogan MV Wang JH

Objectives. After an injury, the biological reattachment of tendon to bone is a challenge because healing takes place between a soft (tendon) and a hard (bone) tissue. Even after healing, the transition zone in the enthesis is not completely regenerated, making it susceptible to re-injury. In this study, we aimed to regenerate Achilles tendon entheses (ATEs) in wounded rats using a combination of kartogenin (KGN) and platelet-rich plasma (PRP). Methods. Wounds created in rat ATEs were given three different treatments: kartogenin platelet-rich plasma (KGN-PRP); PRP; or saline (control), followed by histological and immunochemical analyses, and mechanical testing of the rat ATEs after three months of healing. Results. Histological analysis showed well organised arrangement of collagen fibres and proteoglycan formation in the wounded ATEs in the KGN-PRP group. Furthermore, immunohistochemical analysis revealed fibrocartilage formation in the KGN-PRP-treated ATEs, evidenced by the presence of both collagen I and II in the healed ATE. Larger positively stained collagen III areas were found in both PRP and saline groups than those in the KGN-PRP group. Chondrocyte-related genes, SOX9 and collagen II, and tenocyte-related genes, collagen I and scleraxis (SCX), were also upregulated by KGN-PRP. Moreover, mechanical testing results showed higher ultimate tensile strength in the KGN-PRP group than in the saline control group. In contrast, PRP treatment appeared to have healed the injured ATE but induced no apparent formation of fibrocartilage. The saline-treated group showed poor healing without fibrocartilage tissue formation in the ATEs. Conclusions. Our results show that injection of KGN-PRP induces fibrocartilage formation in the wounded rat ATEs. Hence, KGN-PRP may be a clinically relevant, biological approach to regenerate injured enthesis effectively. Cite this article: J. Zhang, T. Yuan, N. Zheng, Y. Zhou, M. V. Hogan, J. H-C. Wang. The combined use of kartogenin and platelet-rich plasma promotes fibrocartilage formation in the wounded rat Achilles tendon entheses. Bone Joint Res 2017;6:231–244. DOI: 10.1302/2046-3758.64.BJR-2017-0268.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1106 - 1109
1 Aug 2009
Branstetter JG Jackson SR Haggard WO Richelsoph KC Wenke JC

We used a goat model of a contaminated musculoskeletal defect to determine the effectiveness of rapidly-resorbing calcium-sulphate pellets containing amikacin to reduce the local bacterial count. Our findings showed that this treatment eradicated the bacteria quickly, performed as well as standard polymethylmethacrylate mixed with an antibiotic and had many advantages over the latter. The pellets were prepared before surgery and absorbed completely. They released all of the antibiotic and did not require a subsequent operation for their removal. Our study indicated that locally administered antibiotics reduced bacteria within the wound rapidly. This method of treatment may have an important role in decreasing the rate of infection in contaminated wounds


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 12 - 12
1 Nov 2018
McQuail PM McCartney BS McKenna P
Full Access

Orthopaedic surgical site infections (SSI's) prolong total hospital stays by a median of 2 weeks per patient, approximately double re-hospitalization rates, and increase healthcare costs by more than 300%. Patients with orthopaedic SSI's have significant reductions in their health-related quality of life. We performed a systematic review and meta-analysis to compare differences in outcomes between use of sutures and non-absorbable staples for closure of orthopaedic surgical wounds in adults. The primary outcomes were rates of superficial and deep SSI. Secondary outcomes included wound dehiscence, length of hospital stay, patient satisfaction and pain during removal of closure material. Data sources including PubMed, EMBASE, Scopus, Web of Science, Cochrane Library, . clinicaltrials.gov. , National Institute for Health and Research, UK clinical trials gateway were searched for randomised controlled trials (RCT's) meeting inclusion criteria. Sixteen RCT's published between 1987 and 2017 were included. Overall, wound infection outcomes (superficial and deep infections combined) showed no statistically significant difference between closure with staples compared with sutures with arelative risk of 1.17 (95% CI 0.59–2.30, p=0.66). A subgroup was performed specific to hip wound infection outcomes. Interestingly, a sensitivity analysis demonstrated sutures to be statistically favourable (p=0.04) in terms of hip wound infection outcomes. There was no statistically significant difference among secondary outcomes between sutures and staple groups. Overall it appears the choice of sutures or staples in closure of orthopaedic wounds has no effect on wound complications. However, caution is needed in applying the findings to different population groups due to heterogeneity across studies


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 40 - 40
1 Aug 2013
Mackie A Kazi Z Shah K
Full Access

The incidence of wound complications after a hip or a knee replacement is well established, but there is no such data about foot/ankle surgery. Without this data it is difficult to compare performance between different care-providers. It is also difficult to benchmark services that could potentially be provided by a wide range of care providers (chiropodists, podiatrists, podiatric surgeons, general orthopaedic surgeons with a small foot/ankle practice, etc). Our aim was to establish the incidence of wound complications after foot/ankle surgery and provide a baseline for future comparison. Our study was done in two parts. First part was to conduct an opinion-survey of BOFAS members with a substantial foot/ankle practice, on wound complications from foot/ankle surgery in their own practice. Second part was to conduct a prospective study on the incidence of wound complications from our own foot/ankle practice. The study was registered as an audit and did not require ethical approval. All wound complications (skin necrosis, wound dehiscence, superficial and deep infections) were recorded prospectively. Record of such data was obtained by an independent observer, and from multiple sources, to avoid under-reporting. 60 % of the responders to our survey had a predominant foot/ankle practice (exclusive or at least 75 % of their practice was foot/ankle surgery) and were included for further analysis of their responses. A large majority of these responders (64%) reported a rate of 2–5 % for superficial infection, and a significant majority (86 %) reported a deep infection rate of less than 2 %. Results from our own practice showed an incidence of superficial infection of 2.8 % and deep infection of 1.5 %. With increasing focus on clinical outcome measures as an indicator of quality, it is imperative to publish data on wound complications/ infection after foot/ankle surgery, and in the absence of such data, our two-armed study (survey-opinion and prospective audit) provides a useful benchmark for future comparisons


Bone & Joint Research
Vol. 2, Issue 12 | Pages 276 - 284
1 Dec 2013
Karlakki S Brem M Giannini S Khanduja V Stannard J Martin R

Objectives. The period of post-operative treatment before surgical wounds are completely closed remains a key window, during which one can apply new technologies that can minimise complications. One such technology is the use of negative pressure wound therapy to manage and accelerate healing of the closed incisional wound (incisional NPWT). . Methods. We undertook a literature review of this emerging indication to identify evidence within orthopaedic surgery and other surgical disciplines. Literature that supports our current understanding of the mechanisms of action was also reviewed in detail. . Results. A total of 33 publications were identified, including nine clinical study reports from orthopaedic surgery; four from cardiothoracic surgery and 12 from studies in abdominal, plastic and vascular disciplines. Most papers (26 of 33) had been published within the past three years. Thus far two randomised controlled trials – one in orthopaedic and one in cardiothoracic surgery – show evidence of reduced incidence of wound healing complications after between three and five days of post-operative NPWT of two- and four-fold, respectively. Investigations show that reduction in haematoma and seroma, accelerated wound healing and increased clearance of oedema are significant mechanisms of action. . Conclusions. There is a rapidly emerging literature on the effect of NPWT on the closed incision. Initiated and confirmed first with a randomised controlled trial in orthopaedic trauma surgery, studies in abdominal, plastic and vascular surgery with high rates of complications have been reported recently. The evidence from single-use NPWT devices is accumulating. There are no large randomised studies yet in reconstructive joint replacement. Cite this article: Bone Joint Res 2013;2:276–84


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 144 - 144
4 Apr 2023
Markel D Chatterji R Bou-Akl T Wu B Dietz P Ren W
Full Access

Irrigation with antiseptic agents, antibiotics, and surfactants are used for treatment and prevention of infections. Despite desirable microbicidal actions, studies have demonstrated cytotoxic effects on host tissue that may impair healing. This study investigated the extent of tissue damage caused by commonly used irrigation solutions in the presence or absence of infection.

Air pouches created in 60 balb/c mice were divided into two groups (n=30): infected with Staphylococcus aureus and control. One week later the infected group was subdivided into 5 subgroups (n=6) based on irrigation solutions and by day 0 (immediately) and day7 after irrigation (n=3). Solutions included Saline, Bacitracin, Clorpactin, Irrisept and Bactisure. In infected group wash fluid was collected for quantitative analysis of bacterial growth. At the specified times mice were sacrificed, pouch tissue sent for histology, and sections analyzed for inflammation, necrosis, and edema.

Inflammation decreased in infected vs sterile pouches for all solutions except Bacitracin day 0 and for all solutions day 7 with significance in all except Bacitracin (p<0.05). On day 0, necrosis increased in infected vs sterile pouches in Bacitracin (p=0.006), Irrisept (p=0.18), or Bactisure (p=0.07); however, on day 7, necrosis significantly decreased in infected pouches for all solutions (p<0.05) except for Clorpactin (p=0.18). Edema decreased in infected vs sterile pouches on day 0 for all solutions with significance in saline, Irrisept, and Bacitracin (p<0.05). On day 7, infected pouches had decreased edema in saline, Bacitracin, and Bactisure (p<0.05) and increased in Irrisept (p<0.05) and Clorpactin (p=0.069) compared to sterile pouches. Bacterial culture of washouts demonstrated that Clorpactin, Irrisept and Bactisure controlled the infection, whereas saline and Bacitracin showed bacterial multiplication 3.9 × 10^7 CFU/ml and 6.7 × 10^7 CFU/ml respectively. Bacitracin wash showed significantly more bacteria growth compared to Clorpactin (p=0.024), Irrisept (p=0.025) and Bactisure (p=0.025).

Tissue damage varied with irrigation solutions and the presence or absence of infection. Presence of bacteria appeared to lead to less tissue inflammation and edema. Tissue necrosis varied over time with different solutions. Surgeons must weigh risks and benefits when selecting solutions and determining when to irrigate.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 12 - 12
1 Apr 2018
Marques EM Blom AW Erik L Vikki W Sian N
Full Access

Background. The Arthroplasty Pain Experience (APEX) studies are two randomised controlled trials in primary total hip (THR) and knee replacement (TKR) at a large UK orthopaedics centre. APEX investigated the effect of local anaesthetic wound infiltration (LAI), administered before wound closure, in addition to standard analgesia, on pain severity at 12 months. This abstract reports results of the within-trial economic evaluations. Methods. Cost-effectiveness was assessed from the health and social care payer perspective in relation to quality adjusted life years (QALYs). Resource use was collected from hospital records and patient-completed postal questionnaires, and valued using unit cost estimates from local NHS Trust and national tariffs. Missing data were imputed using chained equations. Costs and outcomes were compared per trial arm and plotted in cost-effectiveness planes. The economic results were bootstrapped incremental net monetary benefit statistics (INMB) and cost-effectiveness acceptability curves. One-way deterministic sensitivity analyses explored any methodological uncertainty. Results. In both trials, LAI was cost-saving and more effective than standard care. Using the £20,000 per QALY threshold, in THR, the INMB was £1,125 (95%BCI, £183 to £2,067) and the probability of being cost-effective was over 98%. In TKR, the INMB was £264 (95%BCI, −£710 to £1,238), with only 62% probability of being cost-effective. Considering an NHS perspective only, LAI was no longer dominant in THR, but still highly cost-effective, with an INMB of £961 (95%BCI, £50 to £1,873). Conclusions. Administering LAI is a cost-effective treatment option in THR and TKR surgeries. The evidence is stronger for THR, because of larger QALY gain. In TKR, there is more uncertainty around the economic result, and smaller QALY gains, but results point to LAI being cheaper than standard analgesia, which includes a femoral nerve block. Trial Registration. ISRCTN96095682, 29/04/2010. Funding. NIHR Programme Grant for Applied Research RP-PG-0407-10070


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 32 - 32
1 Aug 2013
Hopper G Deakin A Crane E Clarke J
Full Access

In recent years there has been growing interest in enhanced recovery regimes in lower limb arthroplasty due to potential clinical benefits of early mobilisation along with cost-savings. Following adoption of this regime in a district general hospital, it was observed that traditional dressings were a potential barrier to its success with ongoing wound problems in patients otherwise fit for discharge. The aim of this audit was to assess current wound care practice, implement a potentially improved regime and re-evaluate practice. A prospective clinical audit was performed over a three month period involving 100 patients undergoing hip or knee arthroplasty. Fifty patients with traditional dressings were evaluated prior to change in practice to a modern dressing (Aquacel™ Surgical). Fifty patients were then evaluated with the new dressing to complete the audit cycle. Clinical outcome measures included wear time, number of changes, blister rate and length of stay. Statistical comparisons were performed using Mann Whitney or Fisher's Exact test (statistical significance, p<0.05). Wear time for the traditional dressing (2 days) was significantly shorter than the modern dressing (7 days), p<0.001, and required more changes (0 vs. 3 days), p<0.001. 20% of patients developed blisters with the traditional dressing compared with 4% with the modern dressing (p=0.028). Length of stay was the same for the modern dressing (4 days) compared with the traditional dressing (4 days). However, in the modern group 75% of patients were discharged by day 4 whereas in the traditional group this took until day 6. This audit highlights the problems associated with traditional dressings with frequent early dressing changes, blistering and delayed discharge. These adverse outcomes can be minimised with a modern dressing specifically designed for the demands of lower limb arthroplasty. Units planning to implement enhanced recovery regimes should consider adopting this dressing to avoid compromising patient discharge


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 24 - 24
17 Nov 2023
Alturkistani Z Amin A Hall A
Full Access

Abstract. Objective. The preparation of host degenerate cartilage for repair typically requires cutting and/or scraping to remove the damaged tissue. This can lead to mechanical injury and cartilage cell (chondrocytes) death, potentially limiting the integration of repair material. This study evaluated cell death at the site of cutting injury and determined whether raising the osmotic pressure (hyper-osmolarity) prior to injury could be chondroprotective. Methods. Ex vivo human femoral head cartilage was obtained from 13 patients (5 males and 8 females: 71.8 years old) with Ethical Permission and Patient consent. Cartilage wells were created using 3 or 5mm biopsy punches. Cell death at the wounded edge of the host cartilage and the edge of the extracted explants were assessed by quantifying the percentage of cell death (PCD) and measuring the width of the cell death zone at identified regions of interest (ROI) using the confocal laser scanning microscopy and image analysis software. To assess the chondroprotective effect of hyper-osmolarity, cartilage specimens were incubated in 340 or 600mOsm media, five minutes prior to injury to allow the chondrocytes to respond to the altered osmolarity. Wounded cartilage explants and cartilage wells were then cultured for a further 150 minutes following injury. Results. In 340mOsm media, the PCD around the 3mm cartilage wells was significantly less compared to the corresponding explants (20.05±10.24% vs 35.25±4.86%; P=0.0003). When using the 5mm biopsy punch, the PCD at the wound edges was significantly lower when compared to the 3mm cartilage wells (13.33±7.80% vs 20.05±10.24%; P=0.0121) at the same osmolarity. The width of the cell death zone for the well edges for both 3 and 5mm punches was significantly narrower when compared to their corresponding harvested cartilage explants in 340mOsm media (P<0.0001; P=0.0218, respectively). Exposing cartilage to raised osmolarity (600mOsm) prior to injury significantly reduced the PCD for cartilage wells produced by the 3mm biopsy punches (from 20.05±10.24% to 12.24±6.00%; P=0.0025). In addition, the zone of cell death was marginally reduced at the edges of the 5mm cartilage wells (19.25±15.78mm to 12.72±9.09mm; P=0.0499). Conclusions. The choice of biopsy punch and the osmolarity of the incubation medium prior to cartilage injury markedly affected the extent of chondrocyte death both at the edges of the cartilage wells and the explants. The smaller biopsy punch caused more chondrocyte death in the native cartilage wells compared to the larger punch, but this could be compensated for by the chondroprotective effect of raising the osmotic pressure. In general, there was less cell death at the wounded edges of the cartilage wells, compared to the explants. These results suggest that there is scope for further optimising the cutting implements used to create the cartilage wells and protecting chondrocytes by hyper-osmolarity in order to minimize cell death at cut edges and potentially enhance integration between cartilage repair material and host cartilage. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project