Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 65 - 65
1 Jun 2012
Quah C Yeoman MS Cizinauskas A Cooper K König MA McNally D Boszczyk BM
Full Access

Introduction. Lumbar spondylolysis is a fatigue fracture of the pars interarticularis and correlates with Spina Bifida Oculta (SBO) in 67%. Hpothesis. Load is normally transferred across the arch in axial rotation. Bifid arch results in increased strain across the isthmus of the loaded inferior articular process. Aim of investigation. Finite element (FE) analysis of altered load transfer in combined axial rotation and anteroposterior shear in SBO potentially predisposing to fatigue fracture of the pars interarticularis. Methods. FE models of natural and SBO (L5-S1) including ligaments were axially load to 1kN and an axial rotation of 3° applied. Bilateral stresses and strains on intact and SBO lateral inferior lines of the L5 isthmus were assessed and compared. Results. Under 1000N axial load: Maximum von Mises stress observed on left and right lateral inferior lines of L5 isthmus were 0.13 and 0.24 MPa, with maximum equivalent strain values of 1.56 and 2.91 (strain, for natural spine and SBO, respectively. Combined with 3° axial rotation (rotation of spinal processes toward right lateral side): Left lateral L5 isthmus stresses increased to 0.49 and 0.77 MPa for natural spine and SBO, respectively. Right lateral L5 isthmus values increased to 0.67 and 0.95 MPa for natural spine and SBO, respectively. The percentage increase in SBO strains compared to the natural spine on the L5 isthmus were +57.9 and +40.2%. Conclusion. Significant load transfer occurs through the vertebral arch in axial rotation. In SBO this load transfer is lost and mechanical demand on the isthmus is significantly increased. Strain increases across the L5 isthmus in axial rotation by +40.2% to +57.9% compared to normal and may predispose to fatigue fracture


Bone & Joint Research
Vol. 10, Issue 12 | Pages 797 - 806
8 Dec 2021
Chevalier Y Matsuura M Krüger S Traxler H Fleege† C Rauschmann M Schilling C

Aims

Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques.

Methods

Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S4). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads.