Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims

Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

Methods

This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 9 - 9
1 Jan 2017
Pegg E Gill H MacLeod A
Full Access

Femoral head collapse is a possible complication after surgical treatment of femoral neck fractures. The purpose of this study was to examine whether implantation of a Sliding Hip Screw (SHS) or an X-Bolt could increase the risk of femoral head collapse. Similar to traditional hip screws, the X-Bolt is implanted through the femoral neck; however, it uses an expanding cross-shape to improve rotational stability. The risk of collapse was investigated alongside patient factors, such as osteonecrosis. This numerical study assessed the risk of femoral head collapse using linear eigenvalue buckling (an established method [1]), and also from the maximum von Mises stress within the cortical bone. The femoral head was loaded using the pressures reported by Yoshida et al. for a patient sitting down (reported to put the femoral head at greatest risk of collapse [2]), with a peak pressure of 9.4 MPa and an average pressure of 1.59 MPa. The femur was fixed in all degrees of freedom at a plane through the femoral neck. The X-Bolt and SHS were implanted in accordance with the operative techniques. The femoral head and implants were meshed with quadratic tetrahedral elements, and cortical bone was meshed with triangular thin shell elements. A converged mesh seeding density of 1.2 mm was used. All models were create and solved using ABAQUS finite element software (version 6.12, Simulia, Dassault Systèmes, France). The influence of implant type and presence was examined alongside a variety of patient factors:. Osteonecrosis, modelled as a cone of bone of varying angle, and varying modulus values. Cortical thinning. Reduced cortical modulus. Femoral head size. Twenty-two finite element models were run for each implant condition (intact; implanted with the X-Bolt; implanted with a SHS), resulting in a total of 66 models. The finite element models were validated using experimental tests performed on five 4. th. generation composite Sawbones femurs (Malmö, Sweden), and verified against previously published results [1]. No significant difference was found between the X-Bolt and the SHS, for either critical buckling pressure (p=0.964), or the maximum von Mises stress (p=0.274), indicating no difference in the risk of femoral head collapse. The maximum von Mises stress (and therefore the risk of collapse) within the cortical bone was significantly higher for the intact femoral head compared to both implants (X-Bolt: p=0.048, SHS: p=0.002). Of the factors examined, necrosis of the femoral head caused the greatest increase in risk. The study by Volokh et al. [1] concluded that deterioration of the cancellous bone underneath the cortical shell can greatly increase the risk of femoral head collapse, and the results of the present study support this finding. Interestingly the presence of either an X-Bolt or SHS implant appeared to reduce the risk of femoral head collapse


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 93 - 93
1 Dec 2020
Unal OK Dagtas MZ Demir C Najafov T Ugutmen E
Full Access

Abstract. Background. Proximal fibular osteotomy (PFO) was defined to provide a treatment option for knee pain caused by gonarthrosis(1). Minor surgical procedure, low complication rate and dramatic pain relief were the main reasons for popularization of this procedure(2, 3). However, changes at the knee and ankle joint after PFO were not clarified objectively in the literature. Questions/purposes. We asked: 1) Does PFO change the maximum and average pressures at the medial and lateral chondral surface of the tibia plateau? 2) Are chondral surface stresses redistributed at the knee and ankle joint after PFO? 3)Does PFO change the distribution of total load on the knee joint? 4) Can PFO lead to change in alignment of lower limb?. Methods. This study was conducted at Maltepe University Faculty of Medicine Hospital, Orthopedics and Traumatology Department and Yildiz Technical University Mechanical Engineering Department in Istanbul, Turkey, between September 2019 and February 2020. Finite element analysis (FEA) was used to evaluate effects of PFO(4). One 62 years old, female volunteer's X-ray, computer tomography and magnetic resonance imaging images were used for creating right lower limb model. Two different lower limb models were created. One of them was osteotomized model (OM) which was created according to definition of PFO and the other was non-osteotomized model (NOM). To obtain a stress distribution comparison between the two models, 350 N of axial force was applied to the femoral heads of the models. Results. After PFO, the maximum contact pressures at the medial and lateral tibial cartilages decreased 83.2% and 66.9%, respectively at the knee joint. The average contact pressure decreased 26.1% at the medial tibial cartilage and increased 42.4% at the lateral tibial cartilage. The Von Mises stresses decreased 57.1% at the femoral cartilage and decreased 79.1% at tibial cartilage. The stress on the tibial cartilage increased 44.6%, and stress on the talar cartilage increased 7.1% at the ankle joint. Under a 350 N axial force, distribution of the total load at the knee joint was changed and become more homogenous in OM compared to NOM. Change in lower extremity alignment after PFO could not be evaluated with FEA. Conclusion. FEA revealed that PFO causes some changes in knee and ankle joint kinematics. Main loading at the knee joint shifted from medial tibial cartilage to the lateral tibial cartilage after PFO. Additionally, the stresses on each cartilage were redistributed across a wider and more peripheral area. These changes could be the main reason for pain relief at the knee joint. FEA also demonstrated that the Von Mises stresses of the tibial and talar cartilages of the ankle joint increased after PFO. This stress increase may cause long-term arthritic changes in the ankle joint. Level IV; in silico study


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 127 - 127
1 Jul 2014
Boyd J Gill H Zavatsky A
Full Access

Summary Statement. Simulated increases in body weight led to increased displacement, von Mises stress, and contact pressure in finite element models of the extended and flexed knee. Contact shifted to locations of typical medial osteoarthritis lesions in the extended knee models. Introduction. Obesity is commonly associated with increased risk of osteoarthritis (OA). The effects of increases in body weight and other loads on the stresses and strains within a joint can be calculated using finite element (FE) models. The specific effects for different individuals can be calculated using subject-specific FE models which take individual geometry and forces into account. Model results can then be used to propose mechanisms by which damage within the joint may initiate. Patients & Methods. Twelve subject-specific FE models (Abaqus 6.11) of three normal healthy subjects were created by combining geometry (3T T1-weighted MRI scans processed using Mimics 13.0, Geomagic Studio 11, and SolidWorks 2010) and load cases (Vicon and AMTI motion analysis data processed within AnyBody Technology Version 3.0 and Matlab R2007a). Model geometry included the femur and tibia (rigid bodies), tibial cartilage and femoral cartilage (E = 12 MPa, ν = 0.45), and menisci (E. circumferential. = 120 MPa, ν. circumferential. = 0.2; E. axial/radial. = 20 MPa, ν. axial/radial. = 0.3). The tibia was held fixed while loads were applied to the centre of mass of the femur. Frictional contact (µ = 0.02) was modelled between soft tissues. Of the twelve models, six were of extended knees and six were of mid-range flexed (∼50°) knees. Each of these six models represented a paired set: a “normal” model and an “increased-load” model. In the flexed knee “increased-load” models, loads were doubled; in the extended knee “increased-load” models, loads were increased to a standard 2000 N compressive load across the joint (approximately three to four times larger than the original loads). Maximum displacements, von Mises stresses, and contact pressures on the articulating tibial cartilage and femoral cartilage surfaces were calculated; results of the “normal” and “increased-load” models were compared. Results. Increasing the applied loads increased the maximum displacements, von Mises stresses, and contact pressures. Contact shifted anteriorly in the extended knee models to typical locations of medial OA cartilage lesions. No contact shift occurred in the flexed knee models; contact remained in typical locations of lateral OA cartilage lesions, but the contact area extended in all directions, and displacements, stresses, and pressures increased. Discussion/Conclusion. Comparing the “normal” and “increased-load” results suggested two potential mechanical mechanisms involved in osteoarthritic cartilage lesion development. Contact shifted to areas of previously-unloaded cartilage in the extended knee “increased-load” models. Cartilage has regional material properties, with stiffer cartilage in areas of frequent contact and loading; shifting contact to areas of less-stiff cartilage could damage the cartilage and lead to degenerative diseases such as OA. Contact did not shift in the flexed knee “increased-load” models. Instead, the displacements, stresses, and pressures increased while the centres of contact remained relatively stationary. If these contact variables increase beyond a threshold magnitude, the cartilage could be damaged, potentially leading to OA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 32 - 32
4 Apr 2023
Pareatumbee P Yew A Meng Chou S Koh J Zainul-Abidin S Howe T Tan M
Full Access

To analyse bone stresses in humerus-megaprosthesis construct in response to axial loading under varying implant lengths in proximal humeral replacement following tumour excision. CT scans of 10 cadaveric humeri were processed in 3D Slicer to obtain three-dimensional (3D) models of the cortical and cancellous bone. Megaprostheses of varying body lengths (L) were modelled in FreeCAD to obtain the 3D geometry. Four FE models: group A consisting of intact bone; groups B (L=40mm), C (L=100mm) and D (L=120mm) comprising of humerus-megaprosthesis constructs were created. Isotropic linear elastic behaviour was assigned for all materials. A tensile load of 200N was applied to the elbow joint surface with the glenohumeral joint fixed with fully bonded contact interfaces. Static analysis was performed in Abaqus. The bone was divided at every 5% bone length beginning distally. Statistical analysis was performed on maximum von Mises stresses in cortical and cancellous bone across each slice using one-way ANOVA (0-45% bone length) and paired t-tests (45-70% bone length). To quantify extent of stress shielding, average percentage change in stress from intact bone was also computed. Maximum stress was seen to occur distally and anteriorly above the coronoid fossa. Results indicated statistically significant differences between intact state and shorter megaprostheses relative to longer megaprostheses and proximally between intact and implanted bones. Varying levels of stress shielding were recorded across multiple slices for all megaprosthesis lengths. The degree of stress shielding increased with implant lengthening being 2-4 times in C and D compared to B. Axial loading of the humerus can occur with direct loading on outstretched upper limbs or indirectly through the elbow. Resultant stress shielding effect predicted in longer megaprosthesis models may become clinically relevant in repetitive axial loading during activities of daily living. It is recommended to use shorter megaprosthesis to prevent failure


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 37 - 37
1 Dec 2021
Chen H Gulati A Mangwani J Brockett C Pegg E
Full Access

Abstract. Objectives. The aim of this study was to develop an open-source finite element model of the ankle for identification of the best clinical treatment to restore stability to the ankle after injury. Methods. The ankle geometry was defined from the Visible Human Project Female CT dataset available from the National Library of Medicine, and segmented using Dragonfly software (Object Research Systems, 2020). The finite element model was created with FEBio (University of Utah, 2021) using the dynamic nonlinear implicit solver. Linear isotropic material properties were assigned to the bones (E=7300MPa, ν=0.3, ρ=1730kg/m. 3. ) and cartilage (E=10MPa, ν=0.4, ρ=1100kg/m. 3. ). Spring elements were used to represent the ligaments and material properties were taken from Mondal et al. [1]. Lagrangian contact was defined between the cartilaginous surfaces with μ=0.003. A standing load case was modelled, assuming even distribution of load between the feet. A reaction force of 344.3N was applied to the base of the foot, a muscle force of 252.2N, and the proximal ends of the tibia and fibula were fully constrained. Results. The von Mises stresses closely matched those reported by Mondal et al. for the fibula (Present study: 1.00MPa, Mondal: 1.30MPa) and the talus (Present study: 2.20MPa, Mondal: 2.39MPa). However stresses within the tibia were underpredicted (Present study: 1.08MPa, Mondal: 5.86MPa). This was because the present study modelled a shorter tibial length because of a limitation in the CT slices available, which reduced the bending force. Conclusions. This first step in producing an open source ankle model for the orthopaedics community has shown the potential of the model to generate results comparable with those found in the literature. Future work is underway to examine the robustness of the model under different loading and explore alternative open-source CT datasets. [1] Mondal, S., & Ghosh, R. (2017). J Orthopaedics, 14(3), 329–335. . https://doi.org/10.1016/j.jor.2017.05.003


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 118 - 118
1 Nov 2021
Pareatumbee P Yew A Koh JSB Howe TS Abidin SZ Tan MH
Full Access

Introduction and Objective. Curative resection of proximal humerus tumours is now possible in this era of limb salvage with endoprosthetic replacement considered as the preferred reconstructive option. However, it has also been linked with mechanical and non-mechanical failures such as stem fracture and aseptic loosening. One of the challenges is to ensure that implants will endure the mechanical strain under physiological loading conditions, especially crucial in long surviving patients. The objective is to investigate the effect of varying prosthesis length on the bone and implant stresses in a reconstructed humerus-prosthesis assembly after tumour resection using finite element (FE) modelling. Methods. Computed tomography (CT) scans of 10 humeri were processed in Mimics 17 to create three-dimensional (3D) cortical and cancellous solid bone models. Endoprostheses of different lengths manufactured by Stryker were modelled using Solidworks 2020. The FE models were divided into four groups namely group A consisting of the intact humerus and groups B, C and D composed of humerus-prosthesis assemblies with a body length of 40, 100 and 120 mm respectively and were meshed using linear 4-noded tetrahedral elements in 3matic 13. The models were then imported into Abaqus CAE 6.14. Isotropic linear elastic behaviour with an elastic modulus of 13400, 2000 and 208 000 MPa were assigned to the cortical bone, cancellous bone and prosthesis respectively and a Poisson's ratio of 0.3 was assumed for each material. To represent the lifting of heavy objects and twisting motion, a tensile load of 200 N for axial loading and a 5 Nm torsional load for torsional loading was applied separately to the elbow joint surface with the glenohumeral joint fixed and with all contact interfaces defined as fully bonded. A comparative analysis against literature was performed to validate the intact model. Statistical analysis of the peak von Mises stress values collected from predicted stress contour plots was performed using a one-way repeated measure of analysis of variance (with a Bonferroni post hoc test) using SPSS Statistics 26. The average change in stress of the resected models from the intact state were then determined. Results. The validation of the intact humerus displayed a good agreement with literature values. The peak bone stress occurred distally above the coronoid and olecranon fossa closer to the load application region in the intact and resected bone models with a significant amount of loading borne by the cortical bone, while the peak implant stress occurred at the bone-prosthesis contact interface under both loading conditions. Based on the results obtained, a statistically significant difference (p =.013) in implant stress was only seen to occur between groups B and C under tension. Results illustrate initiation of stress shielding with the bone bearing lesser stress with increasing resection length which may eventually lead to implant failure by causing bone resorption according to Wolff's law. The peak implant stress under torsion was 3–5 times the stress under tension. The best biomechanical behaviour was exhibited in Group D, having the least average change in stress from the intact model, 5% and 3.8% under tension and torsion respectively. It can be deduced that the shorter the prosthesis length, the more pronounced the effect on cortical bone remodelling. With the maximum bone and implant stresses obtained being less than their yield strength, it can be concluded that the bone-implant construct is safe from failure. Conclusions. The developed FE models verified the influence of varying the prosthesis length on the bone and implant stresses and predicted signs of stress shielding in longer endoprostheses. By allowing for 2 cm shortening in the upper extremity and post-surgical scarring, it is beneficial to err towards a shorter endoprosthesis


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 39 - 39
1 Nov 2018
Del-Valle-Mojica J Alonso-Rasgado M Jiménez-Cruz D Bailey C Board T
Full Access

In order to reduce the risk of dislocation larger femoral heads in total hip arthroplasty (THA) are being used by surgeons in recent years. The standard head size of 28 mm used in 73% of all hip procedures in 2003 was used in only 29% in 2016; whereas head sizes of 32 mm and 36 mm combined, were used in 70%. The increase of head size effectively reduces the thickness of the acetabular cup, altering the load transfer. Herein, this research work investigates the effect of increasing the femoral head size on the stresses of the periacetabular bone at two selected regions: A1 (superior) and A2 (anterior). Three Finite Element models were developed from CT scan data of a hemipelvis implanted with a cemented all-polyethylene acetabular cup with a 50 mm outer diameter and inner diameter to accommodate three head sizes: 28 mm, 32 mm and 36 mm. The peak reaction force at the hip joint during one leg stand for an overweight patient with a body weight of 100 Kg was simulated for head sizes investigated. We found that highest average von Mises stress was 5.7 MPa and occurred in the cortical bone of region A1 which is located within Zone 1 boundaries (Charnley &DeLee); whereas a lower stress of 4.0 MPa occurred at region A2. In the two regions the stresses were the same for the three head sizes. Periacetabular bone was found to be insensitive to the increase of femoral head diameter in cemented THA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 183 - 183
1 Jul 2014
Zderic I Windolf M Gueorguiev B Stadelmann V
Full Access

Summary. Time-lapsed CT offers new opportunities to predict the risk of cement leakage and to evaluate the mechanical effects on a vertebral body by monitoring each incremental injection step in an in-vitro vertebroplasty procedure. Introduction. Vertebroplasty has been shown to reinforce weak vertebral bodies and to prophylactically reduce fracture risks. However, bone cement leakage is a major vertebroplasty related problem which can cause severe complications. Leakage risk can be minimised by injecting less cement into the vertebral body, inevitably compromising the mechanical properties of the augmented bone, as a proper endplate-to-endplate connection of the injected cement is needed to obtain a mechanical benefit. Thus the cement flow in a vertebroplasty procedure requires a better understanding. This study aimed at developing a method to monitor the cement flow in a vertebral body and its mechanical effect. Materials and Methods. Eight fresh frozen human cadaveric vertebrae were prepared for augmentation by performing a bitrans- or bipedicular approach. Following they were XTremeCT-scanned (Scanco, Switzerland) at a nominal resolution of 82µm. A custom made setup enabled to fix the vertebrae in the CT bore (Siemens Emotion6) centrically. Bone cement (Vertecem V+, Synthes GmbH, Switzerland) was injected monopedicularly via a syringe driver (Harvard Apparatus, USA). Injection forces were recorded through a load cell (Type 9211, Kistler Instrumente AG, Switzerland) placed on the driver. Either a custom PEEK cannula or a trocar was inserted into each pedicle of a vertebra to allow artifact-free CT scanning. After each milliliter of injection a CT scan of the vertebra was performed at a nominal resolution of 0.63mm. Subsequently, the CT images were resampled to the original XTremeCT image and the cement cloud was segmented. The image data were then further processed for micro finite element (microFE) modeling (FAIM, Numerics88, Canada). The models were then solved for axial stiffness and Von Mises Stress (VMS) distribution. Finally, the vertebrae underwent a biomechanical quasistatic axial compression test (Mini Bionix II 858, MTS Systems Corp., USA). Results. Endplate-to-endplate connection of the cement was reached in 4 vertebrae. The average volume needed to reach the connection was 5.0±1.2 ml. Cement leakage occurred in all vertebrae, whereby in 4 cases the cement leaked into the spine channel. Each successive cement injection step was characterised with an increase of peak injection forces (16.5±12.7N at 1ml to 70.82±21.14N at 6ml). With respect to axial stiffness the mechanical tests and the microFE models correlated well (R. 2. = 0.778). Analyzing the top 100 VMS an elevated stress concentration between the endplate and the cement was observed unless the endplate was in direct contact with the cement. Conclusion. Cement flow can be monitored precisely at each injection step using the time-lapsed CT approach. Combined with microFE modeling the mechanical properties of the augmented bone can be evaluated for different incremental cement volumes injected. Our results suggest augmenting the bone until an endplate-to-endplate connection is established as otherwise partial filling would increase the risk of failure in the trabecular bone structure. This is in close agreement to other studies


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 549 - 556
1 Apr 2007
Udofia I Liu F Jin Z Roberts P Grigoris P

Finite element analysis was used to examine the initial stability after hip resurfacing and the effect of the procedure on the contact mechanics at the articulating surfaces. Models were created with the components positioned anatomically and loaded physiologically through major muscle forces. Total micromovement of less than 10 μm was predicted for the press-fit acetabular components models, much below the 50 μm limit required to encourage osseointegration. Relatively high compressive acetabular and contact stresses were observed in these models. The press-fit procedure showed a moderate influence on the contact mechanics at the bearing surfaces, but produced marked deformation of the acetabular components. No edge contact was predicted for the acetabular components studied.

It is concluded that the frictional compressive stresses generated by the 1 mm to 2 mm interference-fit acetabular components, together with the minimal micromovement, would provide adequate stability for the implant, at least in the immediate post-operative situation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis.