Advertisement for orthosearch.org.uk
Results 1 - 20 of 1950
Results per page:
Bone & Joint Open
Vol. 4, Issue 2 | Pages 79 - 86
10 Feb 2023
McLaughlin JR Johnson MA Lee KR

Aims. The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). Methods. The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four. Results. Seven femoral components (18%) required revision, and none for septic loosening. Four well fixed stems were removed during acetabular revision and three were revised for late infection. One femoral component (3%) was loose by radiological criteria. The mean Harris Hip Score improved from 47 points (SD 4.62) preoperatively to 83 points (SD 9.27) at final follow-up. With revision for any reason as the endpoint, survival of the femoral component was 80% (95% confidence interval (CI) 61% to 90%) at 32 years. With revision for aseptic loosing femoral component, survival was 99% (95% CI 93% to 99%). Conclusion. With regards to aseptic loosening, the Taperloc femoral component provides excellent fixation at a mean follow-up of 32 years. Cite this article: Bone Jt Open 2023;4(2):79–86


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims. Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. Methods. We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m. 2. (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97). Results. There were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case. Conclusion. While dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface. Cite this article: Bone Joint J 2024;106-B(4):352–358


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. Methods. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. Results. No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). Conclusion. There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165–170


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 65 - 74
1 Jan 2016
Phadnis J Huang T Watts A Krishnan J Bain GI

Aims. To date, there is insufficient evidence available to compare the outcome of cemented and uncemented fixation of the humeral stem in reverse shoulder arthroplasty (RSA). . Methods. A systemic review comprising 41 clinical studies was performed to compare the functional outcome and rate of complications of cemented and uncemented stems in RSA. These included 1455 cemented and 329 uncemented shoulders. The clinical characteristics of the two groups were similar. Variables were compared using pooled frequency-weighted means and relative risk ratios (RR). Results. Uncemented stems had a significantly higher incidence of early humeral stem migration (p < 0.001, RR 18.1, 95% confidence interval (CI) 5.0 to 65.2) and non-progressive radiolucent lines (p < 0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence of post-operative fractures of the acromion compared with cemented stems (p = 0.004, RR 14.3, 95% CI 0.9 to 232.8). There was no difference in the risk of stem loosening or revision between the groups. The cemented stems had a greater relative risk of infection (RR 3.3, 95% CI 0.8 to 13.7), nerve injury (RR 5.7, 95% CI 0.7 to 41.5) and thromboembolism (RR 3.9, 95% CI 0.2 to 66.6). The functional outcome and range of movement were equivalent in the two groups. . Discussion. RSA performed with an uncemented stem gives them equivalent functional outcome and a better complication profile than with a cemented stem. The natural history and clinical relevance of early stem migration and radiolucent lines found with uncemented stems requires further long-term study. Take home message: This study demonstrates that uncemented stems have at least equivalent clinical and radiographic outcomes compared with cemented stems when used for reverse total shoulder arthroplasty. . Cite this article: Bone Joint J 2016;98-B:65–74


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1000 - 1007
1 Sep 2024
Gong T Lu M Sheng H Li Z Zhou Y Luo Y Min L Tu C

Aims. Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. Methods. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively. Results. Overall, 21 patients (16%) encountered complications, and the rate of aseptic loosening was 7% (9/134). The survival rate up to 8.5 years was 93% for aseptic loosening as the endpoint, and 88% for any reason as the endpoint, retrospectively. Conclusion. The use of an uncemented distal femoral endoprosthesis with a short, curved stem demonstrated a low incidence of aseptic loosening and achieved long-term survivorship of up to nine years. Meanwhile, aseptic loosening typically occurs in the early stage postoperatively. Cite this article: Bone Joint J 2024;106-B(9):1000–1007


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 18 - 18
23 Feb 2023
Grant M Zeng N Lin M Farrington W Walker M Bayan A Elliot R Van Rooyen R Sharp R Young S
Full Access

Joint registries suggest a downward trend in the use of uncemented Total Knee Replacements (TKR) since 2003, largely related to reports of early failures of uncemented tibial and patella components. Advancements in uncemented design such as trabecular metal may improve outcomes, but there is a scarcity of high-quality data from randomised trials. 319 patients <75 years of age were randomised to either cemented or uncemented TKR implanted using computer navigation. Patellae were resurfaced in all patients. Patient outcome scores, re-operations and radiographic analysis of radiolucent lines were compared. Two year follow up was available for 287 patients (144 cemented vs 143 uncemented). There was no difference in operative time between groups, 73.7 v 71.1 mins (p= 0.08). There were no statistical differences in outcome scores at 2 years, Oxford knee score 42.5 vs 41.8 (p=0.35), International Knee Society 84.6 vs 84.0 (p=0.76), Forgotten Joint Score 66.7 vs 66.4 (p=0.91). There were two revisions, both for infection one in each group (0.33%). 13 cemented and 8 uncemented knees underwent re-operation, the majority of these being manipulation under anaesthetic (85.7%), with no difference (8.3% vs 5.3%, 95% CI -2.81% to 8.89%, p = 0.31). No difference was found in radiographic analysis at 2 years, 1 lucent line was seen in the cemented group and 3 in the uncemented group (0.67% v 2.09%, 95%CI -4.1% to 1.24%, p = 0.29). We found no difference in clinical or radiographic outcomes between cemented and uncemented TKR including routine patella resurfacing at two years. Early results suggest there is no difference between cemented and uncemented TKR at 2 years with reference to survivorship, patient outcomes and radiological parameters


Bone & Joint Open
Vol. 4, Issue 10 | Pages 782 - 790
18 Oct 2023
Hamilton DF Gaston P Macpherson GJ Simpson P Clement ND

Aims. The primary aim of this study is to assess the survival of the uncemented hydroxyapatite (HA) coated Trident II acetabular component as part of a hybrid total hip arthroplasty (THA) using a cemented Exeter stem. The secondary aims are to assess the complications, joint-specific function, health-related quality of life, and radiological signs of loosening of the acetabular component. Methods. A single-centre, prospective cohort study of 125 implants will be undertaken. Patients undergoing hybrid THA at the study centre will be recruited. Inclusion criteria are patients suitable for the use of the uncemented acetabular component, aged 18 to 75 years, willing and able to comply with the study protocol, and provide informed consent. Exclusion criteria includes patients not meeting study inclusion criteria, inadequate bone stock to support fixation of the prosthesis, a BMI > 40 kg/m. 2. , or THA performed for pain relief in those with severely restricted mobility. Results. Implant survival, complications, functional outcomes and radiological assessment up to ten years following index THA (one, two, five, seven, and ten years) will be performed. Functional assessment will include the Oxford Hip Score, Forgotten Joint Score, 12-Item Short Form Health Survey, EuroQol five-dimension health questionnaire, and pain and patient satisfaction. Radiological assessment with assess for acetabula lucent lines, lysis, and loosening according to DeLee and Charnley zones. Conclusion. This study is part of a stepwise introduction of a new device to orthopaedic practice, and careful monitoring of implants should be carried out as part of the Beyond Compliance principles. The results of this study will provide functional, radiological, and survival data to either support the ongoing use of the HA acetabulum or highlight potential limitations of this new implant before wide adoption. Cite this article: Bone Jt Open 2023;4(10):782–790


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1475 - 1480
1 Nov 2015
Inngul C Blomfeldt R Ponzer S Enocson A

The aim of this randomised controlled study was to compare functional and radiological outcomes between modern cemented and uncemented hydroxyapatite coated stems after one year in patients treated surgically for a fracture of the femoral neck. A total of 141 patients aged > 65 years were included. Patients were randomised to be treated with a cemented Exeter stem or an uncemented Bimetric stem. The patients were reviewed at four and 12 months. The cemented group performed better than the uncemented group for the Harris hip score (78 vs 70.7, p = 0.004) at four months and for the Short Musculoskeletal Function Assesment Questionnaire dysfunction score at four (29.8 vs 39.2, p = 0.007) and 12 months (22.3 vs 34.9, p = 0.001). The mean EQ-5D index score was better in the cemented group at four (0.68 vs 0.53, p = 0.001) and 12 months (0.75 vs 0.58, p = < 0.001) follow-up. There were nine intra-operative fractures in the uncemented group and none in the cemented group. . In conclusion, our data do not support the use of an uncemented hydroxyapatite coated stem for the treatment of displaced fractures of the femoral neck in the elderly. Cite this article: Bone Joint J 2015;97-B:1475–80


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 15 - 15
23 Jun 2023
Ricotti RG Flevas D Sokrab R Vigdorchik JM Sculco TP Sculco PK
Full Access

Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden. Currently, uncemented stems are highly preferred in primary THA, but have been associated with higher risk of PFF compared to cemented stems. The use of collared stems in uncemented primary THA has shown promise in reducing PFF rates postoperatively. This retrospective study included 2,294 uncemented primary THAs using the posterior approach performed by two attending surgeons from January 2016 to December 2022. Both surgeons switched from a collarless femoral stem design to a collared design in May 2020. Data was collected regarding stem design, frequency of PFF, and requirement for revision surgery. Periprosthetic fractures were identified and confirmed using medical records and/or radiographic imaging. Fracture rates and percentages between collared and collarless stems were then analyzed. A Fisher's Exact Test was performed to determine if there was a significant association between collared and collarless stem use on PFF rates. A total of 2,294 uncemented primary THAs performed by 2 surgeons were eligible for analysis. 903 (39.4%) patients received a collared stem, and 1,391 (60.6%) patients received a collarless stem. In total, 14 (0.6%) PFFs occurred over the study period. There was 1 fracture (0.1%) out of 903 collared stems, and 13 fractures (0.9%) out of 1,391 collarless stems (p = 0.012). Collared stems were associated with a significant decrease in PFF rate when compared to collarless stems in uncemented primary THA. Future studies are encouraged to continue to investigate PFF and other complication rates with the use of a collared stem design


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 76 - 76
10 Feb 2023
Hooper G Gillespie W Maddumage S Snell D Williman J
Full Access

Our objective was to examine revision rates and patient reported outcome scores (PROMS) for cemented and uncemented primary total knee joint replacement (TKJR) at six months, one year and five years post-operatively. Patients and Methods: This matched cohort study involved secondary analyses of data collected as part of a large prospective observational study monitoring outcomes following knee replacement in Christchurch, New Zealand. Cemented and uncemented TKJR participants (n = 1526) were matched on age (± 5 years), sex and body mass index (BMI). From this larger sample, PROMS data, Oxford Knee Score and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), out to five years post-operatively were analysed for a matched subset of participants (n = 252). The average age of participants was 67.9 years (SD 9.4, range 38-94). There were no differences between cemented and uncemented cohorts on the basis of age, sex, BMI or comorbidities, revision rates or PROMS outcomes. Cemented procedures had greater skin to skin times than uncemented procedures (p < 0.01). Unadjusted outcomes comparing risk for revision across the two participant cohorts did not significantly differ. Overall rates for revision were low (cemented 3.2% v uncemented 2.7%, p=0.70). Propensity adjusted associations between baseline characteristics (age, sex, BMI, comorbidity, baseline Oxford and baseline WOMAC scores) also revealed no differences in risk for revision at any post-operative timepoint. In this large multi-surgeon matched cohort study there were no significant differences in functional outcomes or revision rates, when outcomes following modern cemented and uncemented TKJR were compared out to 5-year follow up. Based on our findings, uncemented TKJR is predictable irrespective of patient's age, BMI or gender


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 16 - 16
23 Feb 2023
Tay M Bolam S Coleman B Munro J Monk A Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand. Unicompartmental knee arthroplasty (UKA) is effective for patients with isolated compartment osteoarthritis, however the procedure has higher revision rates. Long-term survivorship and accurate characterisation of revision reasons are limited by a lack of long-term data and standardised revision definitions. We aimed to identify survivorship, risk factors and revision reasons in a large UKA cohort with up to 20 years follow-up. Patient, implant and revision details were recorded through clinical and radiological review for 2,137 consecutive patients undergoing primary medial UKA across Auckland, Canterbury, Counties Manukau and Waitematā DHB between 2000 and 2017. Revision reasons were determined from review of clinical, laboratory, and radiological records for each patient using a standardised protocol. To ensure complete follow-up data was cross-referenced with the New Zealand Joint Registry to identify patients undergoing subsequent revision outside the hospitals. Implant survival, revision risk and revision reasons were analysed using Cox proportional-hazards and competing risk analyses. Implant survivorship at 15 years was comparable for cemented fixed-bearing (cemFB; 91%) and uncemented mobile-bearing (uncemMB; 91%), but lower for cemented mobile-bearing (cemMB; 80%) implants. There was higher incidence of aseptic loosening with cemented implants (3–4% vs. 0.4% uncemented, p<0.01), osteoarthritis (OA) progression with cemMB implants (9% vs. 3% cemFB/uncemMB; p<0.05) and bearing dislocations with uncemMB implants (3% vs. 2% cemMB, p=0.02). Compared with the oldest patients (≥75 years), there was a nearly two-fold increase in risk for those aged 55–64 (hazard ratio 1.9; confidence interval 1.1-3.3, p=0.03). No association was found with gender, BMI or ASA. Cemented mobile-bearing implants and younger age were linked to lower implant survivorship. These were associated with disease progression and bearing dislocations. The use of cemented fixed-bearing and uncemented mobile-bearing designs have superior comparable long-term survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 12 - 12
10 Feb 2023
Boyle A Zhu M Frampton C Poutawera V Vane A
Full Access

Multiple joint registries have reported better implant survival for patients aged >75 years undergoing total hip arthroplasty (THA) with cemented implant combinations when compared to hybrid or uncemented implant combinations. However, there is considerable variation within these broad implant categories, and it has therefore been suggested that specific implant combinations should be compared. We analysed the most common contemporary uncemented (Corail/Pinnacle), hybrid (Exeter V40/Trident) and cemented (Exeter V40/Exeter X3) implant combinations in the New Zealand Joint Registry (NZJR) for patients aged >75 years. All THAs performed using the selected implants in the NZJR for patients aged >75 years between 1999 and 2018 were included. Demographic data, implant type, and outcome data including implant survival, reason for revision, and post-operative Oxford Hip Scores were obtained from the NZJR, and detailed survival analyses were performed. Primary outcome was revision for any reason. Reason for revision, including femoral or acetabular failure, and time to revision were recorded. 5427 THAs were included. There were 1105 implantations in the uncemented implant combination group, 3040 in the hybrid implant combination group and 1282 in the cemented implant combination group. Patient reported outcomes were comparable across all groups. Revision rates were comparable between the cemented implant combination (0.31 revisions/100 component years) and the hybrid implant combination (0.40 revisions/100 component years) but were statistically significantly higher in the uncemented implant combination (0.80/100 component years). Femoral-sided revisions were significantly greater in the uncemented implant combination group. The cemented implant and hybrid implant combinations provide equivalent survival and functional outcomes in patients aged over 75 years. Caution is advised if considering use of the uncemented implant combination in this age group, predominantly due to a higher risk of femoral sided revisions. The authors recommend comparison of individual implants rather than broad categories of implants


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 12 - 12
3 Mar 2023
Dewhurst H Boktor J Szomolay B Lewis P
Full Access

Background. In recent years, ‘Get It Right First Time (GIRFT)’ have advocated cemented replacements in femoral part of Total hip arthroplasty (THA) especially in older patients. However, many studies were unable to show any difference in outcomes and although cemented prostheses may be associated with better short-term pain outcomes there is no clear advantage in the longer term. It is not clear when and why to do cemented instead of cementless. Aim. To assess differences in patient reported outcomes in uncemented THAs based on patient demographics in order to decide when cementless THA can be done safely. Method. Prospective data collection of consecutive 1079 uncemented THAs performed for 954 patients in single trust between 2010 and 2020. Oxford Hip Score (OHS) and complications were analysed against demographic variables (age, sex, BMI, ASA) and prosthesis features (femoral and acetabular size, offset and acetabular screws). Results. The mean pre-operative OHS was 14.6 which improved to 39.0 at 1 year follow up (P Value=0.000). There was no statistically significant difference between OHS outcome in patients aged over 70 versus younger groups. With a small number of revisable complications increase with age from 50s upwards. Male patients’ OHS score was on average 2.4 points higher than women. Men, however were 2.9 times more likely to experience fractures and high offset hips were 2.5 times more likely to experience dislocations. DAIR, intraoperative calcar fractures, post-operative fractures and dislocations were not associated with worse OHS. Patients with increased BMI had worse pre and post-operative hip functions yet, there was a significant multivariate association between increased BMI and increased improvement in OHS from pre-op to 1 year in women aged 55–80 and men under the age of 60. Femoral stem size increases with age but decreases in male patients over 80. There was no difference found in OHS between bilateral hip replacements and unilateral, nor was there any change found with laterality side of the replacement. Conclusions. This study suggests that ageing >70 is not associated with poorer outcomes despite small number of revisable complication rates that increase with age from 50 upwards. Men had marginally higher average OHS than women At 1 year. Higher BMI or ASA scores are associated with worse pre-operative hips and worse final outcome score. Despite this, the Delta OHS increases with increased BMI shown in the 55–80 year old female patients and male patients under 60. Key Words: THR, Uncemented, Oxford hip score, outcome


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 6 - 6
1 Aug 2021
Kennedy I Hrycaiczuk A Ng N Sheerins O Patil S Jones B Stark A Meek D
Full Access

Periprosthetic fractures (PPF) of the femur following total hip arthroplasty represent a significant complication with a rising incidence. The commonest subtype is Vancouver B2 type, for which revision to a long uncemented tapered fluted stem is a widely accepted management. In this study we compare this procedure to the less commonly performed cement-in-cement revision. All patients undergoing surgical intervention for a Vancouver B2 femoral PPF in a cemented stem from 2008 – 2018 were identified. We collated patient age, gender, ASA score, BMI, operative time, blood transfusion requirement, change in haemoglobin (Hb) level, length of hospital stay and last Oxford Hip Score (OHS). Radiographic analysis was performed to assess time to fracture union and leg length discrepancy. Complications and survivorship of implant and patients were recorded. 43 uncemented and 29 cement-in-cement revisions were identified. There was no difference in patient demographics between groups. A significantly shorter operative time was found in the cement-in-cement group, but there was no difference in transfusion requirement, Hb change, or length of hospital stay. OHS was comparable between groups. A non-significant increase in overall complication rates was found in the revision uncemented group, with a significantly higher dislocation rate. Time of union was comparable and there were no non-unions in the cement-in-cement group. A greater degree of stem subsidence was found in the uncemented group. There was no difference in any revision surgery required in either group. Three patients in the uncemented group died in the perioperative period, compared to none in the cement-in-cement group. With appropriate patient selection, both cement-in-cement and long uncemented tapered stem revision represent appropriate treatment options for Vancouver B2 fractures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 53 - 53
1 Oct 2020
Larson D Rosenberg J Lawlor M Garvin KL Hartman C Lyden E Konigsberg B
Full Access

Introduction. Revision total knee arthroplasty (TKA) is becoming increasingly common in the United States as the population ages and larger numbers of primary TKA are performed in younger individuals. Cemented or uncemented tibial stems are frequently used in revision cases. Decreased clinical outcomes and patient satisfaction have been described for revision TKA. This study aims to determine if the presence of overall pain and tibial pain at the end of the stem differs between cemented and uncemented tibial stems in revision TKA. Methods. This was a retrospective cohort study comparing patients who underwent revision TKA utilizing cemented or uncemented tibial stems in a 15-year period at a single institution with at least two-year follow-up. Exclusion criteria included age under 18, isolated revisions of the femoral component or polyethylene exchanges, lack of preoperative or postoperative imaging, insufficient operative or implant records available for electronic chart review, revision procedures performed at outside facilities, patients who were deceased at the time of survey administration, refusal to participate in the study, and failure to return the mailed survey or respond to a telephone follow-up questionnaire. Radiographic analysis included calculation of the percentage of the tibial canal filled with the implant, as well as measurement of the diameter of the tibial stem. Radiographs were also reviewed for evidence of cavitary defects, pedestal formation, radiolucent lines, and periprosthetic fractures. Mailed surveys addressing overall pain, tibial pain, and satisfaction were analyzed using Fisher's exact test and the independent sample t-test. Logistic regression was used to adjust for age, gender, and preoperative bone loss. Results. A total of 110 patients were included (63 cemented and 47 uncemented stems). No statistically significant differences in stem length, operative side, or indications for revision were found. The uncemented group had a significantly higher percent canal fill (p < 0.0001). Tibial pain at the end of the stem was present in 25.3% of cemented stems and 25.5% of uncemented stems (p = 1.00). There was a trend towards more overall pain in the uncemented cohort, but this did not reach statistical significance. Only 74.6% of cemented patients and 78.7% of uncemented patients were satisfied following revision TKA (p = 0.66). Conclusion. The data supports our hypothesis that there are no differences in end-of-stem pain or overall pain between cemented and uncemented tibial stems in revision TKA. High rates of dissatisfaction were noted in both cohorts postoperatively, consistent with previous literature. Patient factors likely play a large role in the presence of postoperative pain. These factors should be further evaluated in future studies in an effort to reduce pain and improve patient satisfaction


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1774 - 1782
1 Dec 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims. The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. Methods. A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries. Results. The distribution of liner geometries were neutral (39.4%; 79,822), 10° (34.5%; 69,894), 15° (21.6%; 43,722), offset reorientating (2.8%; 5705), offset neutral (0.9%; 1,767), and 20° (0.8%; 1,601). There were 690 (0.34%) revisions for instability. Compared to neutral liners, the adjusted subhazard ratios of revision for instability were: 10°, 0.64 (p < 0.001); 15°, 0.48 (p < 0.001); and offset reorientating, 1.6 (p = 0.010). No association was found with other geometries. 10° and 15° liners had a time-dependent lower risk of revision for instability within the first 1.2 years. In posterior approaches, 10° and 15° liners had a lower risk of revision for instability, with no significant difference between them. The protective effect of lipped over neutral liners was not observed in laterally approached THAs. There were 604 (0.3%) revisions for loosening, but no association between liner geometry and revision for loosening was found. Conclusion. This registry-based study confirms a lower risk of revision for instability in posterior approach THAs with 10° or 15° lipped liners compared to neutral liners, but no significant difference between these lip sizes. A higher revision risk is seen with offset reorientating liners. The benefit of lipped geometries against revision for instability was not seen in laterally approached THAs. Liner geometry does not seem to influence the risk of revision for loosening. Cite this article: Bone Joint J 2021;103-B(12):1774–1782


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 5
1 Mar 2002
Kulkarni R Bourgeault C Greer N Loch D Bechtold J Kyle R Gustilo R
Full Access

Aim: The objective of this study was to compare the initial stability of an uncemented curved long stem femoral component (ABR, Zimmer, Warsaw Indiana) implanted using conventional broaching to an uncemented ABR implanted as a revision using morselized compacted allograft to fill a circumferential proximal bone defect. Materials and Methods: Primary: Eight fresh frozen human femurs were implanted with correctly sized ABR stems without cement using standard surgical instruments and 1mm distal overreaming. The implant was loaded cyclically at 3 hz on a MTS servohdraulic materials test frame in a direction representing the peak force of the stance phase of the gait (2.5 X body weight). A 3-dimensional motion measurement device with six linear variable transformers measure the relative motion between the bone and the prosthesis with an accuracy of 0.5μm. The contruct was loaded in ten cycle increments until the component was seated and then recoverable motion was recorded over a further ten loading cycles. Revision: In the revision case bone loss was modelled by removing all the cancellous bone from the proximal femur with 1mm distal overreaming. Morselized bone graft was impacted into the defect using specially prepared smooth tamps shaped to the geometry of the ABR stem. The original prosthesis was then reimplanted without the use of cement. The seating and testing cycles were repeated. Primary and revision vectors were compared using a paired students t – test. Results: There was no statistically significant difference in the magnitude of the resultant vector of the 3 translational components of the micro motion between the two methods of implantation (p=0.19). Conclusions: Initial stability of a cementless femoral implant is a requirement for bone ingrowth. The use of compacted morsellized allograft in a revision Total Hip Arthroplasty with a proximal circumferential defect can provide a stable bed for the implantation of an uncemented femoral component. The revised implant using the compacted allograft method was initially as stable as the primary implantation. This technique would be particularly applicable when the surgeon would like to avoid the use of cement in a revision setting. The use of this method for uncemented revision Total Hip Arthroplasty should be studied further in a clinical setting before it is advocated for widespread use


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 198 - 204
1 Feb 2020
Perlbach R Palm L Mohaddes M Ivarsson I Schilcher J

Aims. This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993. Methods. Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register. Results. Among patients with possible follow-up of ten and 15 years, 152 and 72 patients remained alive without revision of the acetabular component. The number of deaths was 61 and 50, respectively. Of those who died, six patients in each group had a reoperation performed before death. The number of patients with a reoperation was 22 for those with ten-year follow-up and 21 for those with 15 years of follow-up. The Kaplan-Meier implant survival rate for aseptic loosening among all 370 patients in the cohort was 96.3% (95% confidence interval (CI) 94.1 to 98.5) after ten years and 92.8% (95% CI 89.2 to 96.6) after 15 years. Conclusion. Extensive bone impaction grafting combined with uncemented revision components appears to be a reliable method with favourable long-term survival. This technique offers the advantage of bone stock restoration and disputes the long-standing perception that uncemented components require > 50% of host bone contact for successful implant survival. Cite this article: Bone Joint J 2020;102-B(2):198–204


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1067 - 1074
1 Dec 2021
El-Bakoury A Khedr W Williams M Eid Y Hammad AS

Aims. After failed acetabular fractures, total hip arthroplasty (THA) is a challenging procedure and considered the gold standard treatment. The complexity of the procedure depends on the fracture pattern and the initial fracture management. This study’s primary aim was to evaluate patient-reported outcome measures (PROMs) for patients who underwent delayed uncemented acetabular THA after acetabular fractures. The secondary aims were to assess the radiological outcome and the incidence of the associated complications in those patients. Methods. A total of 40 patients underwent cementless acetabular THA following failed treatment of acetabular fractures. The postoperative clinical and radiological outcomes were evaluated for all the cohort. Results. The median (interquartile range (IQR)) Oxford Hip Score (OHS) improved significantly from 9.5 (7 to 11.5), (95% confidence interval (CI) (8 to 10.6)) to 40 (39 to 44), (95% CI (40 to 43)) postoperatively at the latest follow-up (p < 0.001). It was worth noting that the initial acetabular fracture type (simple vs complex), previous acetabular treatment (ORIF vs conservative), fracture union, and restoration of anatomical centre of rotation (COR) did not affect the final OHS. The reconstructed centre of rotation (COR) was restored in 29 (72.5%) patients. The mean abduction angle in whom acetabular fractures were managed conservatively was statistically significantly higher than the surgically treated patients 42.6° (SD 7.4) vs 38° (SD 5.6)) (p = 0.032). We did not have any case of acetabular or femoral loosening at the time of the last follow-up. We had two patients with successful two-stage revision for infection with overall eight-year survival rate was 95.2% (95% CI 86.6% to 100%) with revision for any reason at a median (IQR) duration of follow-up 50 months (16 to 87) months following THA. Conclusion. Delayed cementless acetabular THA in patients with previous failed acetabular fracture treatments produces good clinical outcomes (PROMS) with excellent survivorship, despite the technically demanding nature of the procedure. The initial fracture treatment does not influence the outcome of delayed THA. In selected cases of acetabular fractures (either nondisplaced or with secondary congruency), the initial nonoperative treatment neither resulted in large acetabular defects nor required additional acetabular reconstruction at the time of THA. Cite this article: Bone Jt Open 2021;2(12):1067–1074