Advertisement for orthosearch.org.uk
Results 1 - 20 of 96
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1086 - 1093
1 Oct 2023
Kolin DA Sculco PK Gonzalez Della Valle A Rodriguez JA Ast MP Chalmers BP

Aims. Blood transfusion and postoperative anaemia are complications of total knee arthroplasty (TKA) that are associated with substantial healthcare costs, morbidity, and mortality. There are few data from large datasets on the risk factors for these complications. Methods. We retrospectively reviewed the records of TKA patients from a single tertiary care institution from February 2016 to December 2020. There were a total of 14,901 patients in this cohort with a mean age of 67.9 years (SD 9.2), and 5,575 patients (37.4%) were male. Outcomes included perioperative blood transfusion and postoperative anaemia, defined a priori as haemoglobin level < 10 g/dl measured on the first day postoperatively. In order to establish a preoperative haemoglobin cutoff, we investigated a preoperative haemoglobin level that would limit transfusion likelihood to ≤ 1% (13 g/dl) and postoperative anaemia likelihood to 4.1%. Risk factors were assessed through multivariable Poisson regression modelling with robust error variance. Results. In multivariable analyses, each gram of tranexamic acid reduced transfusion likelihood by 39% (adjusted risk ratio (ARR) 0.61 (95% confidence interval (CI) 0.47 to 0.78)). Risk factors associated with an increased risk of transfusion included operating time (ARR 2.07 (95% CI 1.54 to 2.77)) and drain use (ARR 1.73 (95% CI 1.34 to 2.24)). Conclusion. In this study, we found that increased tranexamic acid dosing, decreased operating time, and decreased drain use may reduce transfusions following TKA. We also established a single preoperative haemoglobin cutoff of 13 g/dl that could help minimize transfusions and reduce postoperative complete blood counts. Cite this article: Bone Joint J 2023;105-B(10):1086–1093


Objectives. Tranexamic acid (TXA) is an antifibrinolytic agent used as a blood-sparing technique in total knee arthroplasty (TKA), and is routinely administered by intravenous (IV) or intra-articular (IA) injection. Recently, a novel method of TXA administration, the combined IV and IA application of TXA, has been applied in TKA. However, the scientific evidence of combined administration of TXA in TKA is still meagre. This meta-analysis aimed to investigate the efficacy and safety of combined IV and IA TXA in patients undergoing TKA. Materials and Methods. A systematic search was carried out in PubMed, the Cochrane Clinical Trial Register (Issue12 2015), Embase, Web of Science and the Chinese Biomedical Database. Only randomised controlled trials (RCT) evaluating the efficacy and safety of combined use TXA in TKA were identified. Two authors independently identified the eligible studies, extracted data and assessed the methodological quality of included studies. Meta-analysis was conducted using Review Manager 5.3 software. Results. A total of ten RCTs (1143 patients) were included in this study. All the included studies were randomised and the quality of included studies still needed improvement. The results indicated that, compared with either placebo or the single-dose TXA (IV or IA) group, the combination of IV and IA TXA group had significantly less total blood loss, hidden blood loss, total drain output, a lower transfusion rate and a lower drop in haemoglobin level. There were no statistically significant differences in complications such as wound infection and deep vein thrombosis between the combination group and the placebo or single-dose TXA group. Conclusions. Compared with placebo or the single-dose TXA, the combined use of IV and IA TXA provided significantly better results with respect to all outcomes related to post-operative blood loss without increasing the risk of thromboembolic complications in TKA. Cite this article: Z. F. Yuan, H. Yin, W. P. Ma, D. L. Xing. The combined effect of administration of intravenous and topical tranexamic acid on blood loss and transfusion rate in total knee arthroplasty: combined tranexamic acid for TKA. Bone Joint Res 2016;5:353–361. DOI: 10.1302/2046-3758.58.BJR-2016-0001.R2


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 133 - 134
1 Nov 2013
Parvizi J Diaz-Ledezma C

Total knee replacement (TKR) is an operation that can be performed with or without the use of a tourniquet. Meta-analyses of the available Level-1 studies have demonstrated that the use of a tourniquet leads to a significant reduction in blood loss. The opponents for use of a tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbance as drawbacks. Although there may certainly be reason for concern in arteriopathic patients, there is little evidence that routine use of a tourniquet during TKR results in any of the above complications. The use of a tourniquet, on the other hand, provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimal visualisation. Blood conservation has gained great importance in recent years due to increased understanding of the problems associated with blood transfusion, such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay and increased cost. Based on the authors’ understanding of the available evidence, the routine use of a tourniquet during TKR is justified as good surgical practice. . Cite this article: Bone Joint J 2013;95-B, Supple A:133–4


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 83 - 83
7 Aug 2023
Sidhu GAS
Full Access

Abstract. Introduction. Multiple strategies, used either in isolation or combination, are available to reduce the need for post-operative blood transfusion in joint replacements. Amongst them, the use of tranexamic acid (TXA) has been rising and this study was conducted to compare the efficacy of topical and intravenous TXA in bilateral total knee replacement patients. Materials and methods. Randomised prospective study with 120 patients (male: female: 25:95) undergoing bilateral TKA. Patients were divided into two groups A and B after computer randomization, who received intravenous or topical (intra-articular) TXA respectively. Results. The average haemoglobin loss in intravenous group was 90.2379 g/L as compared to 39.137 g/L in topical group (p < 0.005). Moreover, there was reduction in blood loss in topical (330.1602 ml) as compared to intravenous group (764.9622 ml). The blood transfusion rate was more for the intravenous group (average 1.73 units) than for the topical group (average 0.75, unit). WOMAC score at 6 weeks in the intravenous group was 12.50, and in the topical group was 7.23 (p value < 0.001). Conclusion. Topical TXA is better than intravenous TXA for reduction of blood loss, which also reduces the need for blood transfusion in bilateral TKA patients


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 971 - 976
1 Sep 2023
Bourget-Murray J Piroozfar S Smith C Ellison J Bansal R Sharma R Evaniew N Johnson A Powell JN

Aims. This study aims to determine difference in annual rate of early-onset (≤ 90 days) deep surgical site infection (SSI) following primary total knee arthroplasty (TKA) for osteoarthritis, and to identify risk factors that may be associated with infection. Methods. This is a retrospective population-based cohort study using prospectively collected patient-level data between 1 January 2013 and 1 March 2020. The diagnosis of deep SSI was defined as per the Centers for Disease Control/National Healthcare Safety Network criteria. The Mann-Kendall Trend test was used to detect monotonic trends in annual rates of early-onset deep SSI over time. Multiple logistic regression was used to analyze the effect of different patient, surgical, and healthcare setting factors on the risk of developing a deep SSI within 90 days from surgery for patients with complete data. We also report 90-day mortality. Results. A total of 39,038 patients underwent primary TKA for osteoarthritis during the study period. Of these, 275 patients developed a deep SSI within 90 days of surgery, representing a cumulative incidence of 0.7%. The annual infection rate did not significantly decrease over the seven-year study period (p = 0.162). Overall, 13,885 (35.5%) cases were excluded from the risk analysis due to missing data. Risk factors associated with early-onset deep SSI included male sex, American Society of Anesthesiologists grade ≥ 3, blood transfusion, acute length of stay, and surgeon volume < 30 TKAs/year. Early-onset deep SSI was not associated with increased 90-day mortality. Conclusion. This study establishes a reliable baseline infection rate for early-onset deep SSI after TKA for osteoarthritis using robust Infection Prevention and Control surveillance data, and identifies several potentially modifiable risk factors. Cite this article: Bone Joint J 2023;105-B(9):971–976


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 33 - 33
1 Jul 2022
Ilo K Lodge C Berber R Matar H Bloch B
Full Access

Abstract. Introduction. It is common practice for all patients to have postoperative bloods tests after total knee arthroplasty (TKA). However there have been significant improvement in perioperative care with arthroplasty surgery. As healthcare systems and providers strive towards a more efficient service we must re-consider whether such an intervention is necessary for all patients. Methodology. This retrospective study included all patients who underwent a primary unilateral TKA at a single tertiary arthroplasty centre during a 1 year period. Electronic medical records of 776 patients were reviewed for patient demographics, length of stay and American Society of Anaesthesiologists grade. Blood tests were examined to investigate the incidence of post operative anaemia requiring transfusion, electrolyte abnormalities that required treatment and the incidence of acute kidney injury. Results. Average length of stay in hospital was 4.3 days. Pre-operative (R=-0.22) & post-operative haemoglobin (R=0.2) levels were both negatively correlated with length of stay (p<0.01). There was 1 patient that required a blood transfusion post operatively due to symptomatic anaemia. This patient underwent a complex primary TKA. Significant abnormal post-operative electrolyte levels were found in 100 (12.9%) of patients. 87 of these patients either had abnormal electrolyte levels pre-operatively or were taking a medication that causes the electrolyte abnormality. Medical treatment for abnormal electrolyte levels was required in 32 (4.1%) of all patients. The incidence of acute kidney injury was 4.4%. Conclusion. Routine blood tests after primary total knee arthroplasty is unnecessary for most patients. Blood tests should only be performed in those with identifiable risk factors


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 21 - 21
7 Aug 2023
Petsiou D Nicholls K Wilcocks K Matthews A Vachtsevanos L
Full Access

Abstract. Introduction. In patients with bilateral unicompartmental knee osteoarthritis, simultaneous bilateral surgery is cost effective, with both patient-specific and wider socioeconomic benefits. There are concerns however regarding higher complication rates with bilateral knee surgery. This study compares simultaneous bilateral unicompartmental knee arthroplasty (UKA), to single side UKA in terms of complications and outcomes. Methodology. This is a retrospective case-control study of single side medial UKA patients (controls) and simultaneous bilateral medial UKA patients (cases). All patients underwent surgery between 2018 and 2022 by a single surgeon. The two cohorts were compared for perioperative blood loss (PBL), length of stay (LOS), complications (infections, blood clots, wound problems), Oxford Knee Score improvement (OKS) and revision surgery, with a follow-up period of up to 5 years. Results. 64 patients were followed up comprising 55 controls and 9 cases. Average length of stay for controls was 1.55 days and 2.22 days for cases (p=0.03). Average haemoglobin drop was 7.5g/l in controls and 12.8g/l in cases (p=0.04). The OKS improvement was comparable in both groups (p=0.95) with no complications and no revision surgery in either group. Conclusion. The statistically significant differences in PBL and LOS were not clinically relevant. There were no blood transfusions and postoperative haemoglobin was within normal range in more than 60% of cases. Simultaneous bilateral unicompartmental knee arthroplasty is a financially favourable and safe option for patients with bilateral knee medial unicompartmental osteoarthritis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 57 - 57
1 Oct 2020
Zois TP Bohm A Mont M Scuderi GR
Full Access

Background. Revision total knee arthroplasty (rTKA) is a complex procedure with increased risk of blood loss and transfusions. The Musculoskeletal Infection Society has included D-dimer as a serology marker for peri-prosthetic infection. The study's intent is to understand the impact of preoperative D-dimer levels on blood loss and venous thromboembolism in revision TKA. Methods. Following IRB approval, rTKA performed by a single surgeon between January 1, 2017 and December 31, 2019 were reviewed. Inclusion criteria consisted of pre-operative D-Dimer, cemented revision TKA of one or both components under tourniquet control. 89 patients met the criteria including 37 males (41.6%) and 52 females (58.4%). Mean ages were 65 for males and 67 for females. The data revealed 54 patients (61%) had an elevated D-dimer (group 1) and 35 patients (39%) had a normal D-dimer (group 2). Sex stratification showed 21 males (57.8%) and 33 females (63.5%) with elevated D-dimer. TXA protocol included 2 grams intravenous (82 patients) or 2 grams intra-articular application (7 patients). Post-operative anticoagulation included Lovenox 40mg daily for 2 weeks followed by aspirin 325 twice daily for 4 weeks. Pre-operative and post-operative hemoglobin, transfusion rates and post-operative VTE within 90 days of surgery were recorded. Results. The mean pre-operative hemoglobin (hgb) was 13.30 and post-operative was 11.21. The mean change in hgb for males was 2.75 and for females 1.91. Both male and female cohorts had an acceptable range and the change in hgb was not statistically significant (p=0.076). Two female patients (2.25%) were transfused, both receiving IV TXA and their pre-operative hgb was lower than the cohort. No VTE events were identified in either groups of patients within the 90 day post-operative period. Conclusion. This study revealed that TXA is effective in reducing blood loss following rTKA and an elevated D-dimer is not a contraindication to its use


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 490 - 497
1 Apr 2016
Maempel JF Wickramasinghe NR Clement ND Brenkel IJ Walmsley PJ

Aims. The pre-operative level of haemoglobin is the strongest predictor of the peri-operative requirement for blood transfusion after total knee arthroplasty (TKA). There are, however, no studies reporting a value that could be considered to be appropriate pre-operatively. . This study aimed to identify threshold pre-operative levels of haemoglobin that would predict the requirement for blood transfusion in patients who undergo TKA. . Patients and Methods. Analysis of receiver operator characteristic (ROC) curves of 2284 consecutive patients undergoing unilateral TKA was used to determine gender specific thresholds predicting peri-operative transfusion with the highest combined sensitivity and specificity (area under ROC curve 0.79 for males; 0.78 for females). Results. Threshold levels of 13.75 g/dl for males and 12.75 g/dl for females were identified. The rates of transfusion in males and females, respectively above these levels were 3.37% and 7.11%, while below these levels, they were 16.13% and 28.17%. Pre-operative anaemia increased the rate of transfusion by 6.38 times in males and 6.27 times in females. Blood transfusion was associated with an increased incidence of early post-operative confusion (odds ratio (OR) = 3.44), cardiac arrhythmia (OR = 5.90), urinary catheterisation (OR = 1.60), the incidence of deep infection (OR = 4.03) and mortality (OR = 2.35) one year post-operatively, and increased length of stay (eight days vs six days, p < 0.001). . Conclusion. Uncorrected low pre-operative levels of haemoglobin put patients at potentially modifiable risk and attempts should be made to correct this before TKA. Target thresholds for the levels of haemoglobin pre-operatively in males and females are proposed. Take home message: Low pre-operative haemoglobin levels put patients at unnecessary risk and should be corrected prior to surgery. Cite this article: Bone Joint J 2016;98-B:490–7


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 135 - 139
1 Nov 2013
Reinhardt KR Osoria H Nam D Alexiades MA Figgie MP Su EP

Blood loss during total knee replacement (TKR) remains a significant concern. In this study, 114 patients underwent TKR, and were divided into two groups based on whether they received a new generation fibrin sealant intra-operatively, or a local infiltration containing adrenaline. Groups were then compared for mean calculated total blood volume (TBV) loss, transfusion rates, and knee range of movement. Mean TBV loss was similar between groups: fibrin sealant mean was 705 ml (281 to 1744), local adrenaline mean was 712 ml (261 to 2308) (p = 0.929). Overall, significantly fewer units of blood were transfused in the fibrin sealant group (seven units) compared with the local adrenaline group (15 units) (p = 0.0479). Per patient transfused, significantly fewer units of blood were transfused in the fibrin sealant group (1.0 units) compared with the local adrenaline group (1.67 units) (p = 0.027), suggesting that the fibrin sealant may reduce the need for multiple unit transfusions. Knee range of movement was similar between groups. From our results, it appears that application of this newer fibrin sealant results in blood loss and transfusion rates that are low and similar to previously applied fibrin sealants. Cite this article: Bone Joint J 2013;95-B, Supple A:135–9


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 635 - 643
1 Apr 2021
Ross LA Keenan OJF Magill M Brennan CM Clement ND Moran M Patton JT Scott CEH

Aims. Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal femoral arthroplasty (DFA). Methods. This was a retrospective cohort study of 60 consecutive unilateral (PDFFs) of Su types II (40/60) and III (20/60) in patients aged ≥ 60 years: 33 underwent LLP-ORIF (mean age 81.3 years (SD 10.5), BMI 26.7 (SD 5.5); 29/33 female); and 27 underwent DFA (mean age 78.8 years (SD 8.3); BMI 26.7 (SD 6.6); 19/27 female). The primary outcome measure was reoperation. Secondary outcomes included perioperative complications, calculated blood loss, transfusion requirements, functional mobility status, length of acute hospital stay, discharge destination and mortality. Kaplan-Meier survival analysis was performed. Cox multivariate regression analysis was performed to identify risk factors for reoperation after LLP-ORIF. Results. Follow-up was at mean 3.8 years (1.0 to 10.4). One-year mortality was 13% (8/60). Reoperation was more common following LLP-ORIF: 7/33 versus 0/27 (p = 0.008). Five-year survival for reoperation was significantly better following DFA; 100% compared to 70.8% (95% confidence interval (CI) 51.8% to 89.8%, p = 0.006). There was no difference for the endpoint mechanical failure (including radiological loosening); ORIF 74.5% (56.3 to 92.7), and DFA 78.2% (52.3 to 100, p = 0.182). Reoperation following LLP-ORIF was independently associated with medial comminution; hazard ratio (HR) 10.7 (1.45 to 79.5, p = 0.020). Anatomical reduction was protective against reoperation; HR 0.11 (0.013 to 0.96, p = 0.046). When inadequately fixed fractures were excluded, there was no difference in five-year survival for either reoperation (p = 0.156) or mechanical failure (p = 0.453). Conclusion. Absolute reoperation rates are higher following LLP fixation of low PDFFs compared to DFA. Where LLP-ORIF was well performed with augmentation of medial comminution, there was no difference in survival compared to DFA. Though necessary in very low fractures, DFA should be used with caution in patients with greater life expectancies due to the risk of longer term aseptic loosening. Cite this article: Bone Joint J 2021;103-B(4):635–643


Bone & Joint Research
Vol. 9, Issue 6 | Pages 322 - 332
1 Jun 2020
Zhao H Yeersheng R Kang X Xia Y Kang P Wang W

Aims. The aim of this study was to examine whether tourniquet use can improve perioperative blood loss, early function recovery, and pain after primary total knee arthroplasty (TKA) in the setting of multiple-dose intravenous tranexamic acid. Methods. This was a prospective, randomized clinical trial including 180 patients undergoing TKA with multiple doses of intravenous tranexamic acid. One group was treated with a tourniquet during the entire procedure, the second group received a tourniquet during cementing, and the third group did not receive a tourniquet. All patients received the same protocol of intravenous tranexamic acid (20 mg/kg) before skin incision, and three and six hours later (10 mg/kg). The primary outcome measure was perioperative blood loss. Secondary outcome measures were creatine kinase (CK), CRP, interleukin-6 (IL-6), visual analogue scale (VAS) pain score, limb swelling ratio, quadriceps strength, straight leg raising, range of motion (ROM), American Knee Society Score (KSS), and adverse events. Results. The mean total blood loss was lowest in the no-tourniquet group at 867.32 ml (SD 201.11), increased in the limited-tourniquet group at 1024.35 ml (SD 176.35), and was highest in the tourniquet group at 1,213.00 ml (SD 211.48). The hidden blood loss was lowest in the no-tourniquet group (both p < 0.001). There was less mean intraoperative blood loss in the tourniquet group (77.48 ml (SD 24.82)) than in the limited-tourniquet group (137.04 ml (SD 26.96)) and the no-tourniquet group (212.99 ml (SD 56.35); both p < 0.001). Patients in the tourniquet group showed significantly higher levels of muscle damage and inflammation biomarkers such as CK, CRP, and IL-6 than the other two groups (p < 0.05). Outcomes for VAS pain scores, limb swelling ratio, quadriceps strength, straight leg raising, ROM, and KSS were significantly better in the no-tourniquet group at three weeks postoperatively (p < 0.05), but there were no significant differences at three months. No significant differences were observed among the three groups with respect to transfusion rate, thrombotic events, or the length of hospital stay. Conclusion. Patients who underwent TKA with multiple doses of intravenous tranexamic acid but without a tourniquet presented lower total blood loss and hidden blood loss, and they showed less postoperative inflammation reaction, less muscle damage, lower VAS pain score, and better early knee function. Our results argue for not using a tourniquet during TKA. Cite this article: Bone Joint Res 2020;9(6):322–332


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 10 - 16
1 Jul 2019
Fillingham YA Darrith B Calkins TE Abdel MP Malkani AL Schwarzkopf R Padgett DE Culvern C Sershon RA Bini S Della Valle CJ

Aims. Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA. The purpose of this multicentre randomized clinical trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA. Patients and Methods. From six-centres, 233 revision TKAs were randomized to one of four regimens: 1 g of intravenous (IV) TXA given prior to the skin incision, a double-dose regimen of 1 g IV TXA given both prior to skin incision and at time of wound closure, a combination of 1 g IV TXA given prior to skin incision and 1 g of intraoperative topical TXA, or three doses of 1950 mg oral TXA given two hours preoperatively, six hours postoperatively, and on the morning of postoperative day one. Randomization was performed based on the type of revision procedure to ensure equivalent distribution among groups. Power analysis determined that 40 patients per group were necessary to identify a 1 g/dl difference in the reduction of haemoglobin postoperatively between groups with an alpha of 0.05 and power of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence. Results. In total, one patient withdrew, five did not undergo surgery, 16 were screening failures, and 25 did not receive the assigned treatment, leaving 186 patients for analysis. There was no significant difference in haemoglobin reduction among treatments (2.8 g/dl for single-dose IV TXA, 2.6 g/dl for double-dose IV TXA, 2.6 g/dl for combined IV/topical TXA, 2.9 g/dl for oral TXA; p = 0.38). Similarly, calculated blood loss (p = 0.65) and transfusion rates (p = 0.95) were not significantly different between groups. Equivalence testing assuming a 1 g/dl difference in haemoglobin change as clinically relevant showed that all possible pairings were statistically equivalent. Conclusion. Despite the higher risk of blood loss in revision TKA, all TXA regimens tested had equivalent blood-sparing properties. Surgeons should consider using the lowest effective dose and least costly TXA regimen in revision TKA. Cite this article: Bone Joint J 2019;101-B(Supple 7):10–16


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 77 - 83
1 Jul 2019
James EW Blevins JL Gausden EB Turcan S Denova TA Satalich JR Ranawat AS Warren RF Ranawat AS

Aims. Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There are limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) versus a matched cohort of patients undergoing TKA with no history of PKLR. Patients and Methods. Patients with a history of ACL or MLK reconstruction who underwent TKA between 2007 and 2017 were identified in a single-institution registry. There were 223 patients who met inclusion criteria (188 ACL reconstruction patients, 35 MLK reconstruction patients). A matched cohort, also of 223 patients, was identified based on patient age, body mass index (BMI), sex, and year of surgery. There were 144 male patients and 79 female patients in both cohorts. Mean age at the time of TKA was 57.2 years (31 to 88). Mean BMI was 29.7 kg/m. 2. (19.5 to 55.7). Results. There was a significantly higher use of constrained implants among patients with PKLR (76 of 223, 34.1%) compared with the control group (40 of 223, 17.9%; p < 0.001). Subgroup analysis showed a higher use of constrained implants among patients with prior MLK reconstruction (21 of 35, 60.0%) compared with ACL reconstruction (55 of 188, 29.3%; p < 0.001). Removal of hardware was performed in 69.5% of patients with PKLR. Mean operative time (p < 0.001) and tourniquet time (p < 0.001) were longer in patients with PKLR compared with controls. There were no significant differences in rates of deep vein thrombosis, pulmonary embolism, infection, transfusion, postoperative knee range of movement (ROM), or need for revision surgery. There was no significant difference in preoperative or postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) scores between groups. Conclusion. Results of this study suggest a history of PKLR results in increased use of constrained implants but no difference in postoperative knee ROM, patient-reported outcomes, or incidence of revision surgery. Cite this article: Bone Joint J 2019;101-B(7 Supple C):77–83


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 201 - 209
1 Feb 2014
Napier RJ Bennett D McConway J Wilson R Sykes AM Doran E O’Brien S Beverland DE

In an initial randomised controlled trial (RCT) we segregated 180 patients to one of two knee positions following total knee replacement (TKR): six hours of knee flexion using either a jig or knee extension. Outcome measures included post-operative blood loss, fall in haemoglobin, blood transfusion requirements, knee range of movement, limb swelling and functional scores. A second RCT consisted of 420 TKR patients randomised to one of three post-operative knee positions: flexion for three or six hours post-operatively, or knee extension. Positioning of the knee in flexion for six hours immediately after surgery significantly reduced blood loss (p = 0.002). There were no significant differences in post-operative range of movement, swelling, pain or outcome scores between the various knee positions in either study. Post-operative knee flexion may offer a simple and cost-effective way to reduce blood loss and transfusion requirements following TKR. We also report a cautionary note regarding the potential risks of prolonged knee flexion for more than six hours observed during clinical practice in the intervening period between the two trials, with 14 of 289 patients (4.7%) reporting lower limb sensory neuropathy at their three-month review. Cite this article: Bone Joint J 2014;96-B:201–9


Bone & Joint Open
Vol. 4, Issue 5 | Pages 338 - 356
10 May 2023
Belt M Robben B Smolders JMH Schreurs BW Hannink G Smulders K

Aims

To map literature on prognostic factors related to outcomes of revision total knee arthroplasty (rTKA), to identify extensively studied factors and to guide future research into what domains need further exploration.

Methods

We performed a systematic literature search in MEDLINE, Embase, and Web of Science. The search string included multiple synonyms of the following keywords: "revision TKA", "outcome" and "prognostic factor". We searched for studies assessing the association between at least one prognostic factor and at least one outcome measure after rTKA surgery. Data on sample size, study design, prognostic factors, outcomes, and the direction of the association was extracted and included in an evidence map.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 25 - 25
1 Oct 2019
Livshetz I Mohamed N Papas PV Delanois RE Mont MA Scuderi GR
Full Access

Background. As the number of total knee arthroplasties (TKA) being performed continues to increase, the number of potential failures requiring revision surgery would also be expected to increase. This study analyzed the trends in revision TKA (rTKA) from 2009 to 2016. Methods. The Nationwide Inpatient Sample (NIS) database was used to identify all rTKA by International Classification of Diseases, Ninth Revision (ICD-9) and Tenth Revision (ICD-10) codes. The diagnoses leading to revision, revision costs, patient and hospital characteristics, and major inpatient complications were compared between 2009 and 2016. Multivariate logistic regression analyses were used to calculate odds ratios (OR) for complications. Results. A total of 453,770 rTKA were performed between 2009 and 2016 (Table 1). The incidence of rTKA between 2009 and 2016 decreased by 4.3% among all age groups and decreased 5.9% in those over 65 years of age. The mean age at revision remained unchanged at 65 years, the mean Length of Stay (LOS) decreased 19.5% from 4.1 to 3.3 days (p<0.001), and the mean hospital costs increased 18.7% from $23,103 to $27,427 (p<0.001). Male to Female ratio remained unchanged with Females making up 58% of rTKA. The rTKA patients in 2016 versus 2009 had significantly lower odds of requiring a blood transfusion (OR 0.26, p<0.001). The rate of myocardial infarction remained unchanged in 2016 versus 2009 (4.1% vs. 4.0%, p=0.52), as did mortality (0.1% vs. 0.2%, p=0.089). Patients in 2016 were significantly less likely to be discharged to a skilled nursing facility (SNF) (26.5% in 2016 vs. 31.6% in 2009, p<0.001). A significantly larger share of rTKA were performed in urban teaching hospitals in 2016 (66.6% in 2016 vs. 41.5% in 2009, p<0.001). Mechanical loosening remained the most common reason for rTKA and increased from 19.7% in 2009 to 28.4% in 2016. Infection remained the second most common reason for rTKA (14.7% in 2009 vs. 12.2% in 2016). Instability was the third most common reason for revision in 2016 (10.7%) but direct comparison with 2009 could not be made since ICD-9 did not include this diagnosis. When comparing 2009 to 2014, an increase in revision rates was noted. Upon inclusion of 2015 and 2016 data, a decrease is noted. The primary limitation of this study is the challenge faced when comparing results from before and after the October 2015 transition of ICD-9 to ICD-10 codes. Conclusions. The incidence of rTKA had decreased slightly between 2009 and 2016 even while the volume of primary TKA continued to rise. Implant loosening became increasingly prevalent as a reason for revision and infection continued to plague patients after TKA. Positive trends were noted, such as decreased rates of blood transfusion, LOS and rates of discharge to SNF. Still, the revision burden remains large, costing approximately $1.4 billion annually and we must continue to attempt to improve outcomes in this patient population. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 21 - 21
1 Mar 2012
Sharda P Alshryda S Shetty A Kalia P Nargol A Maheswaran S
Full Access

PURPOSE OF STUDY. 20-70% of patients need blood transfusion postoperatively. There remain safety concerns regarding allogenic blood transfusion. Tranexamic acid (TA) is a synthetic antifibrinolytic agent that has been successfully used to stop bleeding in other specialties. We applied TA topically prior to the wound closure to find out the effect on blood loss as well as need for subsequent blood transfusion. This method of administration is quick, easy, has less systemic side effect and provides a higher concentration at the bleeding site. MATERIALS AND METHODS. A double blind randomised controlled trial of 154 patients who underwent unilateral primary cemented total knee replacement. Patients were randomised into tranexamic acid group (1g drug mixed with saline to make up 20mls) or placebo (20ml 0.9% saline). The administration technique and drain protocol was standardised for all patients. Drain output was measured at 24 hours, and both groups compared for need of Blood transfusion. Outcome measures - blood loss, transfusion, complications, Euroqol and Oxford Knee Score. RESULTS. The two groups were comparable in age, weight, height, BMI, and Tourniquet time. There was significant difference in the amount of blood loss and blood transfusion in favour of tranexamic acid (p=0.001 and 0.007 respectively). Fourteen patients needed blood transfusion (ranged from 2 to 6 units). Thirteen were in the Placebo group and only one in the Tranexamic acid. There was no significant difference among other outcomes, in particular complications rates such as DVT and PE. Use of Tranexamic acid is recommended as routine to reduce bleeding and blood transfusion rates following primary Total Knee replacement


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 10 - 10
1 Oct 2019
Stulberg BN Zadzilka JD Kreuzer S Long WJ Kissin YD Liebelt RA Campanelli V Zuhars J
Full Access

Introduction. Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate the safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Methods. Inclusion criteria for patients receiving robotic TKA were: primary unilateral TKA; Kellgren-Lawrence OA grade 3 or 4; BMI < 40 kg/m2; coronal plane deformity < 20° varus; sagittal flexion contracture < 15°. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs were specifically identified to evaluate safety (Healy et al, 2013): medial collateral ligament injury; extensor mechanism disruption; neural deficit; periprosthetic fracture; patellofemoral dislocation; tibiofemoral dislocation; and vascular injury. Bleeding complications were also assessed. Malalignment rate, defined as the percentage of patients with more than a ± 3° difference in varus-valgus alignment from the preoperative plan, was used to determine accuracy of the active robotic system. Knee Society Scores (KSS) and Short Form 12 (SF-12) Health Surveys were assessed as clinical outcome measures. For each outcome, results were compared to published values associated with manual TKA. Results. A total of 115 patients were enrolled at 6 US centers and followed for a maximum of 12 months after surgery. Mean surgical time (incision to close) improved consistently as the technique evolved (first 10 cases = 131.5 min, first 20 cases = 122.4 min), with mean robot time = 45.8 min. The incidence of pre-defined AEs identified was 0%, serving as a measure of safety of the procedure. Outside of the pre-defined list, only one AE was definitely associated with the use of the device; a metal pin was left inside the knee joint but no reoperation was performed. No patients required a blood transfusion. Alignment outside of the ± 3° goal was 11.2% with a difference of 0.5° ± 1.9° (mean ± STD), which represents a 45% statistically significant (posterior probability > 0.95) reduction in malalignment compared to the literature (Mason et al, 2007). Mean KSS Functional scores improved from 40.5 at baseline to 65.3 at 3 months, mean KSS Objective scores improved from 36.8 to 81.0, mean KSS Patient Satisfaction scores improved from 14.4 to 30.6, and mean SF-12 Physical Component scores improved from 32.9 to 43.5. Discussion. The TSolution One Total Knee Application is descended from an active robotic system used in >8000 cases outside the United States since 2002. This trial represents the first US based study of this technology for primary TKA. The clinical study demonstrated positive safety outcomes as none of the seven pre-defined AEs were observed and there were no cases requiring transfusion. A positive effectiveness outcome was also demonstrated as the malalignment rate found in this study showed a substantial reduction from the 32% malalignment rate published in the literature for conventional instruments. KSS and SF-12 scores were comparable to other published TKA series. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1025 - 1032
1 Aug 2018
Wang D Wang H Luo Z Meng W Pei F Li Q Zhou Z Zeng W

Aims. The aim of this study was to identify the most effective regimen of multiple doses of oral tranexamic acid (TXA) in achieving maximum reduction of blood loss in total knee arthroplasty (TKA). Patients and Methods. In this randomized controlled trial, 200 patients were randomized to receive a single dose of 2.0 g of TXA orally two hours preoperatively (group A), a single dose of TXA followed by 1.0 g orally three hours postoperatively (group B), a single dose of TXA followed by 1.0 g three and nine hours postoperatively (group C), or a single dose of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively (group D). All patients followed a routine enhanced-recovery protocol. The primary outcome measure was the total blood loss. Secondary outcome measures were hidden blood loss (HBL), reduction in the level of haemoglobin, the rate of transfusion and adverse events. Results. Groups C (661.1 ml, . sd. 262.4) and D (597.7 ml, . sd. 219.6) had significantly lower mean total blood loss compared with groups A and B. The mean HBL was significantly lower in groups B (699.2 ml), C (533.1 ml) and D (469.9 ml) than in group A (p = 0.006, p < 0.001, and p < 0.001, respectively). Groups C (2.22 ml, . sd. 0.91) and D (2.04 ml, . sd. 0.95) had a lower reduction in the level of haemoglobin than groups A and B. However, there were no differences between groups C and D in relation to the three parameters. Conclusion. The addition of two or three postoperative doses of TXA to one preoperative dose produced a significant reduction in blood loss. The two-dose postoperative regimen is the least necessary regimen for clinical efficacy in primary unilateral TKA. The three-dose regimen produced maximum reduction of blood loss. Cite this article: Bone Joint J 2018;100-B:1025–32