Aims. Blood
Objectives. Tranexamic acid (TXA) is an antifibrinolytic agent used as a blood-sparing technique in total knee arthroplasty (TKA), and is routinely administered by intravenous (IV) or intra-articular (IA) injection. Recently, a novel method of TXA administration, the combined IV and IA application of TXA, has been applied in TKA. However, the scientific evidence of combined administration of TXA in TKA is still meagre. This meta-analysis aimed to investigate the efficacy and safety of combined IV and IA TXA in patients undergoing TKA. Materials and Methods. A systematic search was carried out in PubMed, the Cochrane Clinical Trial Register (Issue12 2015), Embase, Web of Science and the Chinese Biomedical Database. Only randomised controlled trials (RCT) evaluating the efficacy and safety of combined use TXA in TKA were identified. Two authors independently identified the eligible studies, extracted data and assessed the methodological quality of included studies. Meta-analysis was conducted using Review Manager 5.3 software. Results. A total of ten RCTs (1143 patients) were included in this study. All the included studies were randomised and the quality of included studies still needed improvement. The results indicated that, compared with either placebo or the single-dose TXA (IV or IA) group, the combination of IV and IA TXA group had significantly less total blood loss, hidden blood loss, total drain output, a lower
Total knee replacement (TKR) is an operation
that can be performed with or without the use of a tourniquet. Meta-analyses
of the available Level-1 studies have demonstrated that the use
of a tourniquet leads to a significant reduction in blood loss.
The opponents for use of a tourniquet cite development of complications
such as skin bruising, neurovascular injury, and metabolic disturbance
as drawbacks. Although there may certainly be reason for concern
in arteriopathic patients, there is little evidence that routine
use of a tourniquet during TKR results in any of the above complications.
The use of a tourniquet, on the other hand, provides a bloodless
field that allows the surgeon to perform the procedure with expediency
and optimal visualisation. Blood conservation has gained great importance
in recent years due to increased understanding of the problems associated
with blood
Abstract. Introduction. Multiple strategies, used either in isolation or combination, are available to reduce the need for post-operative blood
Aims. This study aims to determine difference in annual rate of early-onset (≤ 90 days) deep surgical site infection (SSI) following primary total knee arthroplasty (TKA) for osteoarthritis, and to identify risk factors that may be associated with infection. Methods. This is a retrospective population-based cohort study using prospectively collected patient-level data between 1 January 2013 and 1 March 2020. The diagnosis of deep SSI was defined as per the Centers for Disease Control/National Healthcare Safety Network criteria. The Mann-Kendall Trend test was used to detect monotonic trends in annual rates of early-onset deep SSI over time. Multiple logistic regression was used to analyze the effect of different patient, surgical, and healthcare setting factors on the risk of developing a deep SSI within 90 days from surgery for patients with complete data. We also report 90-day mortality. Results. A total of 39,038 patients underwent primary TKA for osteoarthritis during the study period. Of these, 275 patients developed a deep SSI within 90 days of surgery, representing a cumulative incidence of 0.7%. The annual infection rate did not significantly decrease over the seven-year study period (p = 0.162). Overall, 13,885 (35.5%) cases were excluded from the risk analysis due to missing data. Risk factors associated with early-onset deep SSI included male sex, American Society of Anesthesiologists grade ≥ 3, blood
Abstract. Introduction. It is common practice for all patients to have postoperative bloods tests after total knee arthroplasty (TKA). However there have been significant improvement in perioperative care with arthroplasty surgery. As healthcare systems and providers strive towards a more efficient service we must re-consider whether such an intervention is necessary for all patients. Methodology. This retrospective study included all patients who underwent a primary unilateral TKA at a single tertiary arthroplasty centre during a 1 year period. Electronic medical records of 776 patients were reviewed for patient demographics, length of stay and American Society of Anaesthesiologists grade. Blood tests were examined to investigate the incidence of post operative anaemia requiring
Abstract. Introduction. In patients with bilateral unicompartmental knee osteoarthritis, simultaneous bilateral surgery is cost effective, with both patient-specific and wider socioeconomic benefits. There are concerns however regarding higher complication rates with bilateral knee surgery. This study compares simultaneous bilateral unicompartmental knee arthroplasty (UKA), to single side UKA in terms of complications and outcomes. Methodology. This is a retrospective case-control study of single side medial UKA patients (controls) and simultaneous bilateral medial UKA patients (cases). All patients underwent surgery between 2018 and 2022 by a single surgeon. The two cohorts were compared for perioperative blood loss (PBL), length of stay (LOS), complications (infections, blood clots, wound problems), Oxford Knee Score improvement (OKS) and revision surgery, with a follow-up period of up to 5 years. Results. 64 patients were followed up comprising 55 controls and 9 cases. Average length of stay for controls was 1.55 days and 2.22 days for cases (p=0.03). Average haemoglobin drop was 7.5g/l in controls and 12.8g/l in cases (p=0.04). The OKS improvement was comparable in both groups (p=0.95) with no complications and no revision surgery in either group. Conclusion. The statistically significant differences in PBL and LOS were not clinically relevant. There were no blood
Background. Revision total knee arthroplasty (rTKA) is a complex procedure with increased risk of blood loss and
Aims. The pre-operative level of haemoglobin is the strongest predictor
of the peri-operative requirement for blood
Blood loss during total knee replacement (TKR)
remains a significant concern. In this study, 114 patients underwent TKR,
and were divided into two groups based on whether they received
a new generation fibrin sealant intra-operatively, or a local infiltration
containing adrenaline. Groups were then compared for mean calculated
total blood volume (TBV) loss,
Aims. Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal femoral arthroplasty (DFA). Methods. This was a retrospective cohort study of 60 consecutive unilateral (PDFFs) of Su types II (40/60) and III (20/60) in patients aged ≥ 60 years: 33 underwent LLP-ORIF (mean age 81.3 years (SD 10.5), BMI 26.7 (SD 5.5); 29/33 female); and 27 underwent DFA (mean age 78.8 years (SD 8.3); BMI 26.7 (SD 6.6); 19/27 female). The primary outcome measure was reoperation. Secondary outcomes included perioperative complications, calculated blood loss,
Aims. The aim of this study was to examine whether tourniquet use can improve perioperative blood loss, early function recovery, and pain after primary total knee arthroplasty (TKA) in the setting of multiple-dose intravenous tranexamic acid. Methods. This was a prospective, randomized clinical trial including 180 patients undergoing TKA with multiple doses of intravenous tranexamic acid. One group was treated with a tourniquet during the entire procedure, the second group received a tourniquet during cementing, and the third group did not receive a tourniquet. All patients received the same protocol of intravenous tranexamic acid (20 mg/kg) before skin incision, and three and six hours later (10 mg/kg). The primary outcome measure was perioperative blood loss. Secondary outcome measures were creatine kinase (CK), CRP, interleukin-6 (IL-6), visual analogue scale (VAS) pain score, limb swelling ratio, quadriceps strength, straight leg raising, range of motion (ROM), American Knee Society Score (KSS), and adverse events. Results. The mean total blood loss was lowest in the no-tourniquet group at 867.32 ml (SD 201.11), increased in the limited-tourniquet group at 1024.35 ml (SD 176.35), and was highest in the tourniquet group at 1,213.00 ml (SD 211.48). The hidden blood loss was lowest in the no-tourniquet group (both p < 0.001). There was less mean intraoperative blood loss in the tourniquet group (77.48 ml (SD 24.82)) than in the limited-tourniquet group (137.04 ml (SD 26.96)) and the no-tourniquet group (212.99 ml (SD 56.35); both p < 0.001). Patients in the tourniquet group showed significantly higher levels of muscle damage and inflammation biomarkers such as CK, CRP, and IL-6 than the other two groups (p < 0.05). Outcomes for VAS pain scores, limb swelling ratio, quadriceps strength, straight leg raising, ROM, and KSS were significantly better in the no-tourniquet group at three weeks postoperatively (p < 0.05), but there were no significant differences at three months. No significant differences were observed among the three groups with respect to
Aims. Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA. The purpose of this multicentre randomized clinical trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA. Patients and Methods. From six-centres, 233 revision TKAs were randomized to one of four regimens: 1 g of intravenous (IV) TXA given prior to the skin incision, a double-dose regimen of 1 g IV TXA given both prior to skin incision and at time of wound closure, a combination of 1 g IV TXA given prior to skin incision and 1 g of intraoperative topical TXA, or three doses of 1950 mg oral TXA given two hours preoperatively, six hours postoperatively, and on the morning of postoperative day one. Randomization was performed based on the type of revision procedure to ensure equivalent distribution among groups. Power analysis determined that 40 patients per group were necessary to identify a 1 g/dl difference in the reduction of haemoglobin postoperatively between groups with an alpha of 0.05 and power of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence. Results. In total, one patient withdrew, five did not undergo surgery, 16 were screening failures, and 25 did not receive the assigned treatment, leaving 186 patients for analysis. There was no significant difference in haemoglobin reduction among treatments (2.8 g/dl for single-dose IV TXA, 2.6 g/dl for double-dose IV TXA, 2.6 g/dl for combined IV/topical TXA, 2.9 g/dl for oral TXA; p = 0.38). Similarly, calculated blood loss (p = 0.65) and
Aims. Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There are limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) versus a matched cohort of patients undergoing TKA with no history of PKLR. Patients and Methods. Patients with a history of ACL or MLK reconstruction who underwent TKA between 2007 and 2017 were identified in a single-institution registry. There were 223 patients who met inclusion criteria (188 ACL reconstruction patients, 35 MLK reconstruction patients). A matched cohort, also of 223 patients, was identified based on patient age, body mass index (BMI), sex, and year of surgery. There were 144 male patients and 79 female patients in both cohorts. Mean age at the time of TKA was 57.2 years (31 to 88). Mean BMI was 29.7 kg/m. 2. (19.5 to 55.7). Results. There was a significantly higher use of constrained implants among patients with PKLR (76 of 223, 34.1%) compared with the control group (40 of 223, 17.9%; p < 0.001). Subgroup analysis showed a higher use of constrained implants among patients with prior MLK reconstruction (21 of 35, 60.0%) compared with ACL reconstruction (55 of 188, 29.3%; p < 0.001). Removal of hardware was performed in 69.5% of patients with PKLR. Mean operative time (p < 0.001) and tourniquet time (p < 0.001) were longer in patients with PKLR compared with controls. There were no significant differences in rates of deep vein thrombosis, pulmonary embolism, infection,
In an initial randomised controlled trial (RCT)
we segregated 180 patients to one of two knee positions following total
knee replacement (TKR): six hours of knee flexion using either a
jig or knee extension. Outcome measures included post-operative
blood loss, fall in haemoglobin, blood
To map literature on prognostic factors related to outcomes of revision total knee arthroplasty (rTKA), to identify extensively studied factors and to guide future research into what domains need further exploration. We performed a systematic literature search in MEDLINE, Embase, and Web of Science. The search string included multiple synonyms of the following keywords: "revision TKA", "outcome" and "prognostic factor". We searched for studies assessing the association between at least one prognostic factor and at least one outcome measure after rTKA surgery. Data on sample size, study design, prognostic factors, outcomes, and the direction of the association was extracted and included in an evidence map.Aims
Methods
Background. As the number of total knee arthroplasties (TKA) being performed continues to increase, the number of potential failures requiring revision surgery would also be expected to increase. This study analyzed the trends in revision TKA (rTKA) from 2009 to 2016. Methods. The Nationwide Inpatient Sample (NIS) database was used to identify all rTKA by International Classification of Diseases, Ninth Revision (ICD-9) and Tenth Revision (ICD-10) codes. The diagnoses leading to revision, revision costs, patient and hospital characteristics, and major inpatient complications were compared between 2009 and 2016. Multivariate logistic regression analyses were used to calculate odds ratios (OR) for complications. Results. A total of 453,770 rTKA were performed between 2009 and 2016 (Table 1). The incidence of rTKA between 2009 and 2016 decreased by 4.3% among all age groups and decreased 5.9% in those over 65 years of age. The mean age at revision remained unchanged at 65 years, the mean Length of Stay (LOS) decreased 19.5% from 4.1 to 3.3 days (p<0.001), and the mean hospital costs increased 18.7% from $23,103 to $27,427 (p<0.001). Male to Female ratio remained unchanged with Females making up 58% of rTKA. The rTKA patients in 2016 versus 2009 had significantly lower odds of requiring a blood
PURPOSE OF STUDY. 20-70% of patients need blood
Introduction. Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate the safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Methods. Inclusion criteria for patients receiving robotic TKA were: primary unilateral TKA; Kellgren-Lawrence OA grade 3 or 4; BMI < 40 kg/m2; coronal plane deformity < 20° varus; sagittal flexion contracture < 15°. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs were specifically identified to evaluate safety (Healy et al, 2013): medial collateral ligament injury; extensor mechanism disruption; neural deficit; periprosthetic fracture; patellofemoral dislocation; tibiofemoral dislocation; and vascular injury. Bleeding complications were also assessed. Malalignment rate, defined as the percentage of patients with more than a ± 3° difference in varus-valgus alignment from the preoperative plan, was used to determine accuracy of the active robotic system. Knee Society Scores (KSS) and Short Form 12 (SF-12) Health Surveys were assessed as clinical outcome measures. For each outcome, results were compared to published values associated with manual TKA. Results. A total of 115 patients were enrolled at 6 US centers and followed for a maximum of 12 months after surgery. Mean surgical time (incision to close) improved consistently as the technique evolved (first 10 cases = 131.5 min, first 20 cases = 122.4 min), with mean robot time = 45.8 min. The incidence of pre-defined AEs identified was 0%, serving as a measure of safety of the procedure. Outside of the pre-defined list, only one AE was definitely associated with the use of the device; a metal pin was left inside the knee joint but no reoperation was performed. No patients required a blood
Aims. The aim of this study was to identify the most effective regimen
of multiple doses of oral tranexamic acid (TXA) in achieving maximum
reduction of blood loss in total knee arthroplasty (TKA). Patients and Methods. In this randomized controlled trial, 200 patients were randomized
to receive a single dose of 2.0 g of TXA orally two hours preoperatively
(group A), a single dose of TXA followed by 1.0 g orally three hours
postoperatively (group B), a single dose of TXA followed by 1.0 g
three and nine hours postoperatively (group C), or a single dose
of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively
(group D). All patients followed a routine enhanced-recovery protocol.
The primary outcome measure was the total blood loss. Secondary
outcome measures were hidden blood loss (HBL), reduction in the
level of haemoglobin, the rate of