Advertisement for orthosearch.org.uk
Results 1 - 20 of 166
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 122 - 122
1 Mar 2012
Hawkins K Gooding B Rowles J
Full Access

Purpose. A comparison of patient satisfaction of service provided by independent sector treatment centres versus an index NHS hospital in total knee replacement surgery. Methods. Patients were all initially listed for total knee replacement (TKR) by a single consultant from the index NHS hospital, Derbyshire Royal Infirmary (DRI). Patients were sent a postal questionnaire and asked to rate the TKR service provided by a given hospital, based on recent inpatient experience. Questions covered quality of care delivered by hospital staff and quality of ward environment. Overall satisfaction was rated. Patients electing surgery under Patient Choice at an independent sector treatment centre (ISTC) were asked about factors that influenced their hospital choice. 100 consecutive patients undergoing TKR at DRI and 100 patients choosing ISTC hospitals were identified. All surgery occurred between April 2003 and September 2006. Results. Questionnaire response rates were 79% for DRI patients and 54% for ISTC. Overall patient satisfaction for TKR service was 95% for DRI and 87% for ISTC. An equal 61% rated the surgeons as excellent in both DRI and ISTC hospitals. Nurses and physiotherapists (& occupational therapists) both scored more highly in ISTC groups (Nurses 69% v 45%; physio/OT 57% v 35%). Ward environment rated excellent in 73% for ISTC and 24% for DRI. The most common reason for choosing ISTC was shorter waiting list (42%). Conclusion. ISTC hospitals scored more highly in terms of nurses, physiotherapy & occupational therapy, and ward environment. In part, this may arise from better staffing levels and newer facilities in the ISTC sector. Despite this, overall patient satisfaction for TKR service remained greater at the index NHS hospital. This suggests overall satisfaction depends on more complex factors than staff and ward environment. Further work is needed to compare objective clinical outcomes of TKR between hospital groups within the NHS


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 84 - 84
7 Nov 2023
Jordaan K Coetzee K Charilaou J Jakoet S
Full Access

Orthopaedic surgery is a practical surgical specialization field, the exit exam for registrars remains written and oral. Despite logbook evaluation and surgical work-based assessments, the question remains: can registrars perform elective surgery upon qualification? In South Africa, obstacles to elective surgical training include the trauma workload, financial constraints, fellowships and the Covid pandemic. In hip and knee arthroplasty, new approaches like the direct anterior approach (DAA) and robotic-assisted knee surgery also contributed to the dilution of cases available for registrar training. There are concerns that orthopaedic registrars do not perform enough cases to achieve surgical proficiency. Review of the last 4 years of registrar logbooks in hip and knee arthroplasty surgery performed in a single tertiary academic hospital in South Africa. We included all primary total hip replacements (THR), total knee replacements (TKR) and hemiarthroplasties (HA) done for neck of femur (NOF) fractures between 1 April 2019 and 30 March 2023. Differentiation between registrar assisting, registrar performing with consultant supervision and registrar performing independent surgery was done. 990 hip arthroplasties (472 Primary THR, 216 NOF THR, 302 NOF HA) and 316 Primary TKR were performed during the study period. In primary elective THR the posterior approach was dominant and used in 76% of cases. In NOF THA the DAA was dominant used in 98% of cases. Primary TKR robotic-assisted technologies was used in 27% (n=94) cases. Registrars as the primary surgeon were the highest in NOF THA at 70% of cases and the lowest performing TKR at 25%. During 3-month rotations, an average registrar performed 12 (2 TKR and 10 THR) and assisted in 35 (10 TKR and 25 THR) cases. Despite the large number of arthroplasties operations being performed over the last 4-year period, the surgical cases done by registrars are below, the proposed minimal cases to provide surgical proficiency during their training period


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 79 - 79
10 Feb 2023
Ward J Di Bella C
Full Access

For all the research into arthroplasty, provision of total knee arthroplasty (TKR) services based on gender in the Australian context is yet to be explored. International literature points toward a heavily gender biased provision of TKA services, skewed away from female patients. This research has aimed to assess the current experience of Australian female patients and to explore better assessment techniques that could provide more equitable services. A retrospective cohort analysis has been conducted using pre-op PROMs data, where available, from the Australian National Joint Replacement Registry (AOANJRR), between 7 August 2018 and 31 December 2021, including: EQ VAS Health; Oxford Knee Score; joint pain; and KOOS-12. Data was adjusted for age, ASA score, BMI, primary diagnosis, public vs private hospital, surgeon gender and years of practice (as estimated from years of registry data available). Of 1,001,231 procedures performed, 27,431 were able to be analysed (12,300 male and 15,131 female). Gender-based bias against female patients reached statistical significance across all PROM scores, according to the Kruskal-Wallis test of difference (p-value <0.0001). Males were more likely to undergo TKR than females, with odds ratios remaining statistically significant when adjusted for age, ASA score, BMI, primary diagnosis, and hospital type. Numbers were further analysed for surgeon years of recorded practice and surgeon gender with mixed results. This study found that women were less likely to undergo TKR despite worse scores on every pre-op PROM available, thus we demonstrate a statistically significant gender-based bias against female patients. More effort needs to be made to identify the base of this bias and find new ways to assess patients that can provide more equitable provision of healthcare


Strategy regarding patella resurfacing in total knee replacement (TKR) remains controversial. TKR revision rates are reportedly influenced by surgeon procedure volume. The study aim was to compare revision outcomes of TKR with and without patella resurfacing in different surgeon volume groups using data from the AOANJRR. The study population included 571,149 primary TKRs for osteoarthritis. Surgeons were classified as low, medium, or high-volume based on the quartiles of mean primary TKR volume between 2011 and 2020. Cumulative percent revision (CPR) using Kaplan-Meier estimates of survivorship were calculated for the three surgeon volume groups with and without patella resurfacing. Cox proportional hazards models, adjusted for age and sex, were used to compare revision risks. High-volume surgeons who did not resurface the patella had the highest all-cause CPR (20-year CPR 10.9%, 95% CI [10.0%, 12.0%]). When the patella was resurfaced, high-volume surgeons had the lowest revision rate (7.3%, 95% CI [6.4%, 8.4%]). When the high-volume groups were compared there was a higher rate of revision for the non-resurfaced group after 6 months. When the medium-volume surgeon groups were compared, not resurfacing the patella also was associated with a higher rate of revision after 3 months. The low-volume comparisons showed an initial higher rate of revision with patella resurfacing, but there was no difference after 3 months. When only patella revisions were considered, there were higher rates of revision in all three volume groups where the patella was not resurfaced. TKR performed by high and medium-volume surgeons without patella resurfacing had higher revision rates compared to when the patella was resurfaced. Resurfacing the patella in the primary procedure protected against revision for patella reasons in all surgeon volume groups. Level of evidence: III (National registry analysis)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 18 - 18
1 Jun 2023
Hoellwarth J Oomatia A Al Muderis M
Full Access

Introduction. Transtibial osseointegration (TFOI) for amputees has limited but clear literature identifying superior quality of life and mobility versus a socketed prosthesis. Some amputees have knee arthritis that would be relieved by a total knee replacement (TKR). No other group has reported performing a TKR in association with TTOI (TKR+TTOI). We report the outcomes of nine patients who had TKR+TTOI, followed for an average 6.5 years. Materials & Methods. Our osseointegration registry was retrospectively reviewed to identify all patients who had TTOI and who also had TKR, performed at least two years prior. Four patients had TKR first the TTOI, four patients had simultaneous TKR+TTOI, and one patient had 1 OI first then TKR. All constructs were in continuity from hinged TKR to the prosthetic limb. Outcomes were: complications prompting surgical intervention, and changes in daily prosthesis wear hours, Questionnaire for Persons with a Transfemoral Amputation (QTFA), and Short Form 36 (SF36). All patients had clinical follow-up, but two patients did not have complete survey and mobility tests at both time periods. Results. Six (67%) were male, average age 51.2±14.7 years. All primary amputations were performed to manage traumatic injury or its sequelae. No patients died. Five patients (56%) developed infection leading to eventual transfemoral amputation 36.0±15.3 months later, and 1 patient had a single debridement six years after TTOI with no additional surgery in the subsequent two years. All patients who had transfemoral amputation elected for and received transfemoral osseointegration, and no infections occurred, although one patient sustained a periprosthetic fracture which was managed with internal fixation and implant retention and walks independently. The proportion of patients who wore their prosthesis at least 8 hours daily was 5/9=56%, versus 7/9=78% (p=.620). Even after proximal level amputation, the QTFA scores improved versus prior to TKR+TTOI, although not significantly: Global (45.2±20.3 vs 66.7±27.6, p=.179), Problem (39.8±19.8 vs 21.5±16.8, p=.205), Mobility (54.8±28.1 vs 67.7±25.0, p=.356). SF36 changes were also non-significant: Mental (58.6±7.0 vs 46.1±11.0, p=.068), Physical (34.3±6.1 vs 35.2±13.7, p=.904). Conclusions. TKR+TTOI presents a high risk for eventual infection prompting subsequent transfemoral amputation. Although none of these patients died, in general, TKR infection can lead to patient mortality. Given the exceptional benefit to preserving the knee joint to preserve amputee mobility and quality of life, it would be devastating to flatly force transtibial amputees with severe degenerative knee joint pain and unable to use a socket prosthesis to choose between TTOI but a painful knee, or preemptive transfemoral amputation for transfemoral osseointegration. Therefore, TTOI for patients who also request TKR must be considered cautiously. Given that this frequency of infection does not occur in patients who have total hip replacement in association with transfemoral osseointegration, the underlying issue may not be that linked joint replacement with osseointegrated limb replacement is incompatible, but may require further consideration of biological barriers to ascending infection and/or significant changes to implant design, surgical technique, or other yet-uncertain factors


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 20 - 20
1 Jan 2022
Kattimani R Denning A Syed F
Full Access

Abstract. Background. The European population is consistently getting older and this trend is expected to continue with fastest rise seen in those over 85 years old. As a consequence there will be more nonagenarians (over 90 years old) having lower limb arthroplasty. Objectives. To compare the length of stay, readmission and one year mortality between nonagenarians and people aged between 70 to 80 years after having lower limb arthroplasty. Methods. Retrospective review of patients electronic records over 90 years following total knee replacement (TKR) or total hip replacement (THR). The length of stay after surgery, 30 day readmission rate and one year mortality were compared with control group aged between 70 to 80 years who had lower limb arthroplasty during the same period. Results. There were 31 nonagenarians with mean age of 91.6 years and the control group consisted of 31 patients with the mean age of 74.6 years. The average length of stay was 5 days in the nonagenarians compared to 4 days in the younger group. There was no difference in the 1 year mortality. 30 day readmission's was 16% in the older cohort and 5% in the younger. There was an increase in trend of nonagenarians having lower limb arthroplasty over the years. Conclusions. There is increasing number of nonagenarians undergoing lower limb arthroplasty. Nonagenarians and those aged between 70 to 80 years have comparable length of stay and 1 year mortality but higher rate of readmissions after lower limb arthroplasty


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 24 - 24
1 Jan 2022
Shaeir M Raad M Graham S Shrivastava R
Full Access

Abstract. Background. Blood transfusion requirement after primary total hip replacements (THR) and total knee replacements (TKR) was found to be related to increased post-operative complications rate and length of hospital stay. Pre-operative haemoglobin level remains the single most important factor determining the requirement for post-operative blood transfusion. Methods. We carried out a local retrospective audit of 977 THRs and TKRs in 2019. Pre-operative and pre-transfusion haemoglobin levels for transfused group of patients were recorded. Results. A total of 977 patients had THRs and TKRs of which 34 (3.5%) had blood transfusions. From the 437 THRs, 24(5.5%) had bloods transfusions of which 19 were female. From the 540 TKRs 10(1.8%) were transfused, 9 were female. The average length of stay (LOS) for those transfused was 6.8 days and the average LOS for our trust is 3.2 days. Conclusion. The incidence of blood transfusion after primary THR or TKR was 3.5% in 2019. The majority of patients who received post-operative blood transfusion were found to have pre-operative haemoglobin level below 12 g/dl representing 61.7% of all the transfused patients. Transfused patients had more than double the average expected length of stay. The incidence of blood transfusion and associated risks can be improved by early detection and proper management of pre-op anaemia. Pre-assessment clinic has got a pivotal role but needs reminding of pre-op haemoglobin management strategies. Pre-operative optimisation of patients using either oral, intravenous iron supplements or erythropoietin according to the blood management protocol by the Royal College of Surgeons


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 24 - 24
1 Aug 2013
Sriphirom P Chompoosang T khongphaophong M Churasiri P
Full Access

Few previous studies showed that the conventional total knee replacement (TKR) has affection to the same side of talar tilt (TT). We expected to prevent this problem by the computer-assisted (CAS) TKR. The purpose of this study was to compare between pre and post-operative talar tilt and ankle clinical assessment on the CAS TKR and the Conventional TKR in 28 patients (56 knees) whom underwent bilateral TKR. 28 patients, 56 knees, whom underwent both CAS total knee replacement (TKR) and conventional total knee replacement (TKR), in both knees, with the combination of Gap Balance and Measurement Resection techniques performed by one surgeon (P. Sriphirom) at Rajavithi Hospital, Bangkok. The post-operative has a 12 months follow-up for ankle radiographic finding by tibiotalar angle (TTA), tibial articular surface angle (TAS), and talar tilt (TT) = (TAS-TTA) and for ankle clinical assessment by foot functional index (FFI) from pre-operation and post-operation from both groups. The study also compares the CAS TKR with the Conventional TKR for pre-operation and post-operation. 56 knees, 28 patients, mean age = 67.79 years whom underwent bilateral TKR by the Conventional group and the CAS group had pre-operative TT (TT = TAS − TTA). The Conventional group = 1.5 (−5, 8), the CAS group = 0.5 (−5, 8), P value = 0.65. On post-operative TT the Conventional group = 0.0 (−5, 3), the CAS group = 1.0 (−3, 8), the P value = 0.4. The comparison of pre-operative TT and post-operative TT in the Conventional group, the P value = 0.01. On pre-operative TT and post-operative TT in the CAS group, the P value = 0.65. TT was significantly different in the Conventional group but was not significantly different in the CAS group. The ankle clinical assessment by foot functional index (FFI), which are (1) Pain, (2) Difficulty living, and (3) Daily life activity limitation. The pre-operative FFI in the Conventional group = 1.85 (0.81, 6.88) and pre-operative FFI in the CAS group = 1.91 (0.24, 66.5), the P value = 0.57. The post-operative FFI in the Conventional group = 1.68 (0.24, 7.0) and post-operative FFI in the CAS group = 1.65 (0.24, 6.76), the P value = 0.04, which showed a significantly different between the post-operative FFI from both groups. In the Conventional group the post-operative FFI was not significantly different from pre-operative FFI, the P value = 0.2 but for the CAS group the post-operative FFI was not significantly different from pre-operative FFI, the P value = 0.04. This study showed that the conventional TKR effected to post-operative talar, tilt but CAS TKR has less effect and was not significantly different to ankle joint. Finally, the study needs to be conducted on more patients and to be observed on a longer term follow-up


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 7 - 7
1 Feb 2021
Glenday J Gonzalez FQ Wright T Lipman J Sculco P Vigdorchik J
Full Access

Introduction. Varus alignment in total knee replacement (TKR) results in a larger portion of the joint load carried by the medial compartment. [1]. Increased burden on the medial compartment could negatively impact the implant fixation, especially for cementless TKR that requires bone ingrowth. Our aim was to quantify the effect varus alignment on the bone-implant interaction of cementless tibial baseplates. To this end, we evaluated the bone-implant micromotion and the amount of bone at risk of failure. [2,3]. Methods. Finite element models (Fig.1) were developed from pre-operative CT scans of the tibiae of 11 female patients with osteoarthritis (age: 58–77 years). We sought to compare two loading conditions from Smith et al.;. [1]. these corresponded to a mechanically aligned knee and a knee with 4° of varus. Consequently, we virtually implanted each model with a two-peg cementless baseplate following two tibial alignment strategies: mechanical alignment (i.e., perpendicular to the tibial mechanical axis) and 2° tibial varus alignment (the femoral resection accounts for additional 2° varus). The baseplate was modeled as solid titanium (E=114.3 GPa; v=0.33). The pegs and a 1.2 mm layer on the bone-contact surface were modeled as 3D-printed porous titanium (E=1.1 GPa; v=0.3). Bone material properties were non-homogeneous, determined from the CT scans using relationships specific to the proximal tibia. [2,4]. The bone-implant interface was modelled as frictional with friction coefficients for solid and porous titanium of 0.6 and 1.1, respectively. The tibia was fixed 77 mm distal to the resection. For mechanical alignment, instrumented TKR loads previously measured in vivo. [5]. were applied to the top of the baseplate throughout level gait in 2% intervals (Fig.1a). For varus alignment, the varus/valgus moment was modified to match the ratio of medial-lateral force distribution from Smith et al. [1]. (Fig.1b). Results. For both alignments and all bones, the largest micromotion and amount of bone at risk of failure occurred during mid stance, at 16% of gait (Figs.2,3). Peak micromotion, located at the antero-lateral edge of the baseplate, was 153±32 µm and 273±48 µm for mechanical and varus alignment, respectively. The area of the baseplate with micromotion above 40 µm (the threshold for bone ingrowth. [3]. ) was 28±5% and 41±4% for mechanical and varus alignment, respectively. The amount of bone at risk of failure at the bone-implant interface was 0.5±0.3% and 0.8±0.3% for the mechanical and varus alignment, respectively. Discussion. The peak micromotion and the baseplate area with micromotion above 40 µm increased with varus alignment compared to mechanical alignment. Furthermore, the amount of bone at risk of failure, although small for both alignments, was greater for varus alignment. These results suggest that varus alignment, consisting of a combination of femoral and tibial alignment, may negatively impact bone ingrowth and increase the risk of bone failure for cementless tibial baseplates of this TKR design


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 2 - 2
1 May 2016
Affatato S Jaber S Paola T
Full Access

Introduction. Wear and survival of total joint replacements do not depend on the duration of the implant in situ, but rather on the amount of its use, i.e. the patient's activity level [1]. With this in mind, the present study was driven by two questions: (1) How does total knee replacement (TKR) respond to the simulation of daily highly demanding activities? (2) How does implant size affect wear response of total knee replacement (TKR)?. Materials & Methods. Two sets of the same total knee prosthesis (TKP), different in size (#2 and #6), equal in design, were tested on a three-plus-one knee joint simulator for two million cycles using a highly demanding daily load waveform [2], replicating a stair-climbing movement. The results were compared with two sets of TKP previously tested with the ISO level walking task. Gravimetric and micro-Raman spectroscopic analyses were carried out on the polyethylene inserts. Visual comparison with in vivo explants was carried out and digital microscopy was used to characterize the superficial structure of all the TKPs and explanted components. Results. The average volumetric loss of the UHMWPE inserts tested for 2Mc under ISO standard level walking were 21.36 ±1 mm3 and 41 ±2 mm3 for the size #2 and size #6, respectively. The average volumetric mass loss after two million cycles for the size #2 under the stair climbing simulation was 44 ±6 mm3. Microscope examinations showed some deep scratches along the flexion/extension movements for all the components. A decrease in crystallinity, induced by mechanical stress was observed on all polyethylene components and was quantitatively confirmed by the orthorhombic fraction αo value. Conclusion. These preliminary results showed that under more severe conditions for size #2, the material properties change according to a different wear mechanism and a decrease in crystallinity occurs. Under the ISO 14243-2 load profile, an increase in crystallinity was observed; whereas under the more demanding conditions, a decrease in crystallinity occurs. Analyses on the size #6 component are in progress


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 90 - 90
1 Jul 2020
Khan J Ahmed R
Full Access

To determine the effect of Dexamethasone on post-operative pain management in patients undergoing Total Knee Arthroplasty in terms of numerical pain rating scale and total opoid consumption. This Randomized Controlled Trail (RCT) was conducted for 02 years (7th September 2015 to 6th September 2017). All patients undergoing primary Unilateral Total Knee Replacement (TKR) for Osteoarthritis knee were included in the study. Patients with poor glycemic control (HbA1c > 7.6), Hepatic/Renal failure, corticosteroids/ Immunosuppression drug usage in the last 06 months, known psychiatric illnesses were excluded from the study. All patients were operated by consultant Orthopaedic surgeon under Spinal Anaesthesia and tourniquet control using medial para-patellar approach. Patients were randomly divided into 02 groups, A and B. 79 patients were placed in each group. Group A given 0.1mg/kg body weight Dexamethasone Intravenously 15 minutes prior to surgery and another dose 24 hours post-operatively while in group B (control group) no Dexamethasone given. Post-operative pain using the numerical pain rating scale (NRS) and total narcotics consumed converted to morphine dose equivalent noted immediately post-op, 12-, 24- and 48-hours post-operatively. Data analysis done using SPSS version 23. A total of 158 patients were included in the study. Of the total, 98 (62.02%) were females and 60 (37.98%) males. Average BMI of patients 26.94 ±3.14 kg/m2. Patients in group A required less post-operative analgesics (p < 0 .01) and had a better numerical pain rating scale score (p < 0 .01) as compared to group B. Pain scores at 24- and 48-hours post-op were significantly less for Dexamethasone group (p < 0 .01). Use of Dexamethasone per- and post-operatively reduces the pain and amount of analgesics used in patients undergoing TKA. For any reader queries, please contact . drjunaidrmc@gmail.com


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 56 - 56
1 Feb 2020
Broberg J Howard J Lanting B Vasarhelyi E Yuan X Naudie D Teeter M
Full Access

Introduction. Surgeons performing a total knee replacement (TKR) have two available techniques available to help them achieve the proper bone resections and ligament tension – gap balancing (GB) and measured resection (MR). GB relies on balancing ligaments prior to bony resections whereas bony resections are made based on anatomical landmarks in MR. Many studies have been done to compare the joint kinematics between the two techniques, however the results have been varied. These studies were not done with anatomically designed prostheses. The Journey II (Smith & Nephew, Memphis, TN) is one such design which attempts to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Given the design differences between anatomical and non-anatomical prostheses, it is important to investigate whether one technique provides superior kinematics when an anatomical design is used. We hypothesize that there will be no difference between the two techniques. Methods. A total of 56 individuals were recruited to receive a Journey II prosthesis and randomized evenly to groups where the GB technique or MR technique is used. For all patients in the study, a series of radiostereometric analysis (RSA) images were acquired at 3-months post-operatively at different knee flexion angles, ranging in 20° increments from 0° to 120°. Model-based RSA software (RSACore, Leiden, Netherlands) was used to obtain the 3D positions and orientations of the femoral and tibial implant components, which were in turn used to obtain kinematic measures (contact locations and magnitude of excursion) for each condyle. Results. Preliminary results for the anterior-posterior (AP) contact locations from 33 patients (18 GB, 15 MR) are displayed in Figure 1. There were no significant differences in medial and lateral contact locations between the GB and MR groups for all angles of flexion. However, the pattern of medial contact for the MR technique displays more paradoxical anterior motion at mid-flexion (40°–60°) than the GB group. There were no significant differences in magnitude of excursion between groups on both medial (mean difference=1.96 mm, p=0.16) and lateral (mean difference=0.21 mm, p=0.79) condyles, indicating that posterior femoral rollback is similar between groups. Conclusions. Early results suggest that the MR technique is associated with slightly more abnormal kinematics than the GB technique when an anatomical prosthesis design is used for TKR. The GB technique may be more appropriate than MR technique for implanting anatomically designed knee replacements. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 55 - 55
1 Feb 2020
Broberg J Howard J Lanting B Vasarhelyi E Yuan X McCalden R Naudie D Teeter M
Full Access

Introduction. Despite improvements in the survivorship of total knee replacements (TKR) over the years, patient satisfaction following TKR has not improved, with approximately 20% of patients recording dissatisfaction with their new knee joint. It is unclear why many patients feel this way, but it may relate in part to implant designs that do not provide a “natural” feeling knee. Implant manufacturers continue to introduce new concepts for implant design, which are essential for reaching the goal of a “normal” knee after TKR surgery. The Journey II TKR (Smith & Nephew) was developed with this goal in mind. Its anatomical design attempts to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Our objective is to examine patients receiving the Journey II TKR to measure the knee joint contact kinematics of the Journey II TKR compared to a non-anatomically designed implant by the same manufacturer. We hypothesize that the Journey II TKR will have more natural contact kinematics that differ from the non-anatomically designed implant. Methods. A total of 28 individuals were recruited to receive a Journey II TKR, matching an existing prior cohort with a non-anatomical design from the same manufacturer (Legion TKR, Smith & Nephew). For both groups, a series of radiostereometric analysis (RSA) images were acquired at different knee flexion angles, ranging in 20° increments from 0° to 120°. Model-based RSA software (RSACore, Leiden, Netherlands) was used to obtain the 3D positions and orientations of the femoral and tibial implant components, which were in turn used to obtain kinematic measures (contact locations and magnitude of excursion) for each condyle. Results from the Journey II TKR group at 3 months post-operation were compared to the 2-year post-operative measurements from the Legion TKR group. Results. Preliminary results for the anterior-posterior (AP) contact locations from 38 patients (15 Journey II TKR, 23 Legion TKR) are displayed in Figure 1. The Journey II TKR group showed more anterior contact medially and laterally relative to the Legion TKR group at many angles, however the overall pattern from 0°–120° was similar. There was no significant difference between groups with respect to magnitude of excursion on both medial (mean difference=1.29 mm, p=0.19) and lateral (mean difference=0.69 mm, p=0.60) condyles. Conclusions. Early results suggest that paradoxical anterior motion and reduced posterior femoral rollback are present in the anatomically designed Journey II TKR, suggesting that it does not provide substantially different knee kinematics compared to the non-anatomically designed Legion TKR. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 5 - 5
1 Feb 2020
Burton W Myers C Rullkoetter P
Full Access

Introduction. Gait laboratory measurement of whole-body kinematics and ground reaction forces during a wide range of activities is frequently performed in joint replacement patient diagnosis, monitoring, and rehabilitation programs. These data are commonly processed in musculoskeletal modeling platforms such as OpenSim and Anybody to estimate muscle and joint reaction forces during activity. However, the processing required to obtain musculoskeletal estimates can be time consuming, requires significant expertise, and thus seriously limits the patient populations studied. Accordingly, the purpose of this study was to evaluate the potential of deep learning methods for estimating muscle and joint reaction forces over time given kinematic data, height, weight, and ground reaction forces for total knee replacement (TKR) patients performing activities of daily living (ADLs). Methods. 70 TKR patients were fitted with 32 reflective markers used to define anatomical landmarks for 3D motion capture. Patients were instructed to perform a range of tasks including gait, step-down and sit-to-stand. Gait was performed at a self-selected pace, step down from an 8” step height, and sit-to-stand using a chair height of 17”. Tasks were performed over a force platform while force data was collected at 2000 Hz and a 14 camera motion capture system collected at 100 Hz. The resulting data was processed in OpenSim to estimate joint reaction and muscle forces in the hip and knee using static optimization. The full set of data consisted of 135 instances from 70 patients with 63 sit-to-stands, 15 right-sided step downs, 14 left-sided step downs, and 43 gait sequences. Two classes of neural networks (NNs), a recurrent neural network (RNN) and temporal convolutional neural network (TCN), were trained to predict activity classification from joint angle, ground reaction force, and anthropometrics. The NNs were trained to predict muscle and joint reaction forces over time from the same input metrics. The 135 instances were split into 100 instances for training, 15 for validation, and 20 for testing. Results. The RNN and TCN yielded classification accuracies of 90% and 100% on the test set. Correlation coefficients between ground truth and predictions from the test set ranged from 0.81–0.95 for the RNN, depending on the activity. Predictions from both NNs were qualitatively assessed. Both NNs were able to effectively learn relationships between the input and output variables. Discussion. The objective of the study was to develop and evaluate deep learning methods for predicting patient mechanics from standard gait lab data. The resulting models classified activities with excellent performance, and showed promise for predicting exact values for loading metrics for a range of different activities. These results indicate potential for real-time prediction of musculoskeletal metrics with application in patient diagnostics and rehabilitation. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 69 - 69
1 Feb 2020
Kebbach M Geier A Darowski M Krueger S Schilling C Grupp T Bader R
Full Access

Introduction. Persistent patellofemoral (PF) pain is a common postoperative complication after total knee arthroplasty (TKA). In the USA, patella resurfacing is conducted in more than 80% of primary TKAs [1], and is, therefore, an important factor during surgery. Studies have revealed that the position of the patellar component is still controversially discussed [2–4]. However, only a limited number of studies address the biomechanical impact of patellar component malalignment on PF dynamics [2]. Hence, the purpose of our present study was to analyze the effect of patellar component positioning on PF dynamics by means of musculoskeletal multibody simulation in which a detailed knee joint model resembled the loading of an unconstrained cruciate-retaining (CR) total knee replacement (TKR) with dome patella button. Material and Methods. Our musculoskeletal multibody model simulation of a dynamic squat motion bases on the SimTK data set (male, 88 years, 66.7 kg) [5] and was implemented in the multibody dynamics software SIMPACK (V9.7, Dassault Systèmes Deutschland GmbH, Gilching, Germany). The model served as a reference for our parameter analyses on the impact on the patellar surfacing, as it resembles an unconstrained CR-TKR (P.F.C. Sigma, DePuy Synthes, Warsaw, IN) while offering the opportunity for experimental validation on the basis of instrumented implant components [5]. Relevant ligaments and muscle structures were considered within the model. Muscle forces were calculated using a variant of the computed muscle control algorithm. PF and tibiofemoral (TF) joints were modeled with six degrees of freedom by implementing a polygon-contact model, enabling roll-glide kinematics. Relative to the reference model, we analyzed six patellar component alignments: superior-inferior position, mediolateral position, patella spin, patella tilt, flexion-extension and thickness. The effect of each configuration was evaluated by taking the root-mean-square error (RMSE) of the PF contact force, patellar shift and patellar tilt with respect to the reference model along knee flexion angle. Results. The analysis showed that the PF contact force was mostly affected by patellar component thickness (RMSE=440 N) as well as superior-inferior (RMSE=199 N), and mediolateral (RMSE=98 N) positioning.. PF kinematics was mostly affected by mediolateral positioning, patellar component thickness, and superior-inferior positioning. Medialization of the patellar component reduced the peak PF contact force and caused a lateral patellar shift. Discussion. Based on our findings, we conclude that malalignment in mediolateral and superior-inferior direction, tilt and thickness of patellar resurfacing are the most important intraoperative parameters to affect PF dynamics. It could be shown that the translational positioning is more critical than rotational positioning regarding PF contact force. Reported findings are in good agreement with previous experimental and clinical studies [2–4]. Our data reveal that patellar component positioning has to be aligned precisely during total knee arthroplasty to prevent postoperative complications. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 14 - 14
1 Apr 2019
Azhar MS Ahmed S Gogi N Walsh G Chakrabarty G
Full Access

Background of study. Total Knee Replacement (TKR) is one of the commonest elective arthroplasty operations. Crepe dressings are used following TKR by most surgeons as it may provide comfort and hemostasis through external pressure however, may reduce early range of motion (ROM). Avoiding crepe dressings after TKR saves operating time, avoids bulky dressings (which may reduce ROM) and allows interventions such as cryotherapy in the early post-operative period. There are no published studies comparing the use of crepe dressing after TKR with an impermeable dressing alone. Materials and Methods. We did a retrospective study, analysing patients who had a TKR with the use of crepe dressings compared with patients who had an impermeable dressing alone. All patients had cruciate retaining PFC Implants through the medial para-patellar approach. We compared ROM (at initial physio contact and on discharge), rate of wound leakage, opioid requirements and duration of inpatient stay. Results. Data from 40 patients with similar demographics was analysed; 20 in each group. There was no significant difference in; the ROM at initial physiotherapy contact and at discharge (P< 0.01), rate of wound leakage, opioid use and pain score during inpatient stay. The duration of inpatient stay was shorter in patients in whom a crepe dressing was not used. Conclusion. Avoiding the use of Crepe dressings after TKR does not improve early ROM, pain scores, opioid use or wound leakage in the immediate post-operative period. The duration of inpatient stay was shorter without a crepe dressing. Therefore, both practices can be safely used in clinical practice


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 27 - 27
1 Apr 2019
Shah N Vaishnav M Patel M Wankhade U
Full Access

Objective. To evaluate the clinical and functional outcomes obtained by combination of high-flexion Freedom® Total Knee System (TKS) and mini-subvastus approach in total knee replacement patients. Method. This is a retrospective, observational, real world study conducted at Mumbai in India from 2011 to 2016. All patients who were above the age of 18 and operated for total knee replacement (TKR) with mini-subvastus approach using Freedom (Maxx Medical) by the senior author were included. The Implant survivorship was the survey endpoint; primary endpoint was range of motion (ROM); and secondary endpoints were AKSS (American Knee Society Score) and WOMAC (Western Ontario and McMaster Universities Osteoarthritis) scores collected pre- and post-operatively. Results. 184 patients with 242 knees (126 unilateral and 58 bilateral) were operated with high-flexion TKS. Average age of patients was 70 ± 6.2 years. The mean ROM increased from 99.4°±10.44° (50°-120°) preoperatively to 116.78°±8.18° (88°–140°) postoperatively (p<0.001). Clinical and functional AKSS scores improved from 60.83±5.12 to 91.16±2.19 (p<0.001) and 65.35±3.52 to 99.13±4.61 (p<0.001) respectively. There average WOMAC pain scores improved from 12.12±1.72 to 0.066±0.37 (<0.0001). Moreover, post-operative WOMAC stiffness and function scores depicted significant improvement from 4.43±0.97 to 0.03±0.26 (p<0.0001) and 0.03±0.26 to 0.18±1.21 (p<0.0001) respectively at a mean follow-up of 3.71 ± 0.98 years. Implant survivorship was 100%. Conclusion. High-flexion Freedom® TKS demonstrated a satisfactory clinical and functional improvements including high flexion when operated by the mini-subvastus approach at a mean FU of 4 years


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 124 - 124
1 Apr 2019
Karia M Ali A Harris S Abel R Cobb J
Full Access

Background. Defining optimal coronal alignment in Total Knee Replacement (TKR) is a controversial and poorly understood subject. Tibial bone density may affect implant stability and functional outcomes following TKR. Our aim was to compare the bone density profile at the implant-tibia interface following TKR in mechanical versus kinematic alignment. Methods. Pre-operative CT scans for 10 patients undergoing medial unicompartmental knee arthroplasty were obtained. Using surgical planning software, tibial cuts were made for TKR with 7 degrees posterior slope and either neutral (mechanical) or 3 degrees varus (kinematic) alignment. Signal intensity, in Hounsfield Units (HU), was measured at 25,600 points throughout an axial slice at the implant-tibia interface and density profiles compared along defined radial axes from the centre of the tibia towards the cortices (Hotelling's t-squared and paired t-test). Results. From the tibial centre towards the lateral cortex, trabecular bone density for kinematic and mechanical TKR are similar in the inner 50% but differ significantly beyond this (p= 0.012). There were two distinct density peaks, with peak trabecular bone density being higher in kinematic TKR (p<0.001) and peak cortical bone density being higher in mechanical TKR (p<0.01). The difference in peak cortical to peak trabecular signal was 43 HU and 185 HU respectively (p<0.001). On the medial side there was no significant difference in density profile and a linear increase from centre to cortex. Conclusions. In the lateral proximal tibia, there is significantly less difference between peak cortical and peak trabecular bone densities in kinematic TKR compared to mechanical TKR. Laterally, mechanical TKR may be more dependent upon cortical bone for support compared to kinematic TKR, where trabecular bone density is higher. This may have implications for surgical planning and implant design


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 27 - 27
1 Feb 2020
Bloomfield R Williams H Broberg J Lanting B Teeter M
Full Access

Objective. Wearable sensors have enabled objective functional data collection from patients before total knee replacement (TKR) and at clinical follow-ups post-surgery whereas traditional evaluation has solely relied on self-reported subjective measures. The timed-up-and-go (TUG) test has been used to evaluate function but is commonly measured using only total completion time, which does not assess joint function or test completion strategy. The current work employs machine learning techniques to distinguish patient groups based on derived functional metrics from the TUG test and expose clinically important functional parameters that are predictive of patient recovery. Methods. Patients scheduled for TKR (n=70) were recruited and instrumented with a wearable sensor system while performing three TUG test trials. Remaining study patients (n=68) also completed three TUG trials at their 2, 6, and 13-week follow-ups. Many patients (n=36) have also participated up to their 26-week appointment. Custom developed software was used to segment recorded tests into sub-activities and extract 54 functional metrics to evaluate op/non-operative knee function. All preoperative TUG samples and their standardized metrics were clustered into two unlabelled groups using the k-means algorithm. Both groups were tracked forward to see how their early functional parameters translated to functional improvement at their three-month assessment. Test total completion time was used to estimate overall functional improvement and to relate findings to existing literature. Patients that completed their 26-week tests were tracked further to their most recent timepoint. Results. Preoperative clustering separated two groups with different test completion times (n=46 vs. n=22 with mean times of 13s vs. 22s). Of the faster preoperative group, 63% of patients maintained their time, 26% improved, and 11% worsened whereas of the slower preoperative group, 27% maintained, 64% improved, and 9% worsened. The high improvement group improved their times by 4.9s (p<0.01) between preoperative and 13-week visits whereas the other group had no significant change. Test times were different between both groups preoperatively (p<0.001) and at 6 (p=0.01) and 13 (p=0.03) weeks but not at 26 weeks (p=0.67). The high improvement group reached an overall improvement of 9s (p<0.01) at 26 weeks whereas the low improvement group still showed no improvement greater than the TUG minimal detectable change of 2.2s (1.8s, p<0.01)[1]. Test sub-activity times for both groups at each timepoint can be seen in Figure 1. Conclusions. This work has demonstrated that machine learning has the potential to find patterns in preoperative functional parameters that can predict functional improvement after surgery. While useful for assigning labels to the distinguished clusters, test completion time was not among the top distinguishable metrics between groups at three months which highlights the necessity for these more descriptive performance metrics when analyzing patient recovery. It is expected that these early predictions will be used to realistically adjust patient expectations or highlight opportunities for physiotherapeutic intervention to improve future outcomes. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 33 - 33
1 Feb 2020
Maag C Cracaoanu I Langhorn J Heldreth M
Full Access

INTRODUCTION. Implant wear testing is traditionally undertaken using standardized inputs set out by ISO or ASTM. These inputs are based on a single individual performing a single activity with a specific implant. Standardization helps ensure that implants are tested to a known set of parameters from which comparisons may be drawn but it has limitations as patients perform varied activities, with different implant sizes and designs that produce different kinematics/kinetics. In this study, wear performance has been evaluated using gait implant specific loading/kinematics and comparing to a combination deep knee bend (DKB), step down (SD) and gait implant specific loading on cruciate retaining (CR) rotating platform (RP) total knee replacements (TKR). This combination activity profile better replicates patient activities of daily living (ADL). METHODS. Two sets of three ATTUNE. ®. size 5 right leg CR RP TKRs (DePuy Synthes, Warsaw, IN) were used in a study to evaluate ADL implant wear. Implant specific loading profiles were produced via a validated finite element lower limb model [1] that uses activity data such as gait (K1L_110108_1_86p), SD (K1L_240309_2_144p), and DKB (K9P_2239_0_9_I1) from the Orthoload database [2] to produce external boundary conditions. Each set of components were tested using a VIVO joint simulator (AMTI, Watertown, MA, Figure 1) for a total of 4.5 million cycles (Mcyc). All cycles were conducted at 0.8Hz in force-control with flexion driven in displacement control. Bovine calf serum lubricant was prepared to a total protein concentration of 18g/L and maintained at 37°±2°C. Wear of the tibial inserts was quantified via gravimetric methods per ISO14243–2:2009(E). Polyethylene tibial insert weights were taken prior to testing and every 0.5Mcyc there after which corresponded to serum exchange intervals. The multi-activity test intervals were split into10 loops of 1,250 DKB, 3,000 SD, and 45,750 gait cycles in series. Based on activity data presented by Wimmer et al. the number of cycles per activity and activities used is sufficient for a person that is considered active [3]. A loaded soak control was used to compensate for fluid absorption in wear rate calculations. Wear rates were calculated using linear regression. RESULTS SECTION. The wear rate for the gait-only activity test was calculated to be 0.20±0.04mg/Mcyc conversely the wear rate for the multi-activity test was 2.65±0.67mg/Mcyc (Figure 2). Wear scars can be found in Figure 3. Using a two-sided t-test of unequal variance, it was found that there was a significant difference between the two wear rates (p=0.004). DISCUSSION. Adding activities to the wear simulation test significantly increased the average wear rate of the test samples, confirming that changes in cross shear from different activities will tend to increase the wear of an implant. The results of this study prove that single activity wear testing may not be the most clinically severe wear testing that can be used for pre-clinical wear assessment. For any figures or tables, please contact the authors directly