Aims. The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. Methods. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. Results. There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the
Despite advancements, revision rates following total ankle replacement (TAR) are high in comparison to other total joint replacements. This explant analysis study aimed to investigate whether there was appreciable metal particulate debris release from various contemporary TARs by describing patterns of material loss. Twenty-eight explanted TARs (9 designs: 3 fixed and 6 mobile bearing), revised for any reason, were studied. The articulating surfaces of the metal tibial and talar components as well as the polyethylene insert were assessed for damage features using light microscopy. Based on the results of the microscopic analysis, scanning electron microscopy with energy dispersive X-ray spectroscopy was performed to determine the composition of embedded debris identified, as well as non-contacting 3D profilometry. Pitting, indicative of material loss, was identified on the articulating surfaces of 54% of
Aims. Total ankle arthroplasty (TAA) has become the most reliable surgical solution for patients with end-stage arthritis of the ankle. Aseptic loosening of the talar component is the most common complication. A custom-made artificial talus can be used as the talar component in a combined TAA for patients with poor bone stock of the talus. The purpose of this study was to investigate the functional and clinical outcomes of combined TAA. Patients and Methods. Ten patients (two men, eight women; ten ankles) treated using a combined TAA between 2009 and 2013 were matched for age, gender, and length of follow-up with 12 patients (one man, 11 women; 12 ankles) who underwent a standard TAA. All had end-stage arthritis of the ankle. The combined TAA features a
Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up.Aims
Methods
Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018.Aims
Methods
The aim of this study was to capture 12-month outcomes from a representative multicentre cohort of patients undergoing total ankle arthroplasty (TAA), describe the pattern of patient-reported outcome measures (PROMs) at 12 months, and identify predictors of these outcome measures. Patients listed for a primary TAA at 19 NHS hospitals between February 2016 and October 2017 were eligible. PROMs data were collected preoperatively and at six and 12 months including: Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ (foot and ankle)) and the EuroQol five-dimension five-level questionnaire (EQ-5D-5L). Radiological pre- and postoperative data included Kellgren-Lawrence score and implant position measurement. This was supplemented by data from the National Joint Registry through record linkage to determine: American Society of Anesthesiologists (ASA) grade at index procedure; indication for surgery, index ankle previous fracture; tibial hind foot alignment; additional surgery at the time of TAA; and implant type. Multivariate regression models assessed outcomes, and the relationship between MOXFQ and EQ-5D-5L outcomes, with patient characteristics.Aims
Methods
The purpose of this study was to evaluate the
change in sagittal tibiotalar alignment after total ankle arthroplasty (TAA)
for osteoarthritis and to investigate factors affecting the restoration
of alignment. . This retrospective study included 119 patients (120 ankles) who
underwent three component TAA using the Hintegra prosthesis. A total
of 63 ankles had anterior displacement of the talus before surgery
(group A), 49 had alignment in the normal range (group B), and eight
had posterior displacement of the talus (group C). Ankles in group
A were further sub-divided into those in whom normal alignment was
restored following TAA (41 ankles) and those with persistent displacement
(22 ankles). Radiographic and clinical results were assessed. Pre-operatively, the alignment in group A was significantly more
varus than that in group B, and the posterior slope of the tibial
plafond was greater (p <
0.01 in both cases). The posterior slope
of the
We describe the medium-term results of a prospective study of 200 total ankle replacements at a single-centre using the Scandinavian Total Ankle Replacement. A total of 24 ankles (12%) have been revised, 20 by fusion and four by further replacement and 27 patients (33 ankles) have died. All the surviving patients were seen at a minimum of five years after operation. The five-year survival was 93.3% (95% confidence interval (CI) 89.8 to 96.8) and the ten-year survival 80.3% (95% CI 71.0 to 89.6). Anterior subluxation of the talus, often seen on the lateral radiograph in osteoarthritic ankles, was corrected and, in most instances, the anatomical alignment was restored by total ankle replacement. The orientation of the
We present the outcomes in 38 consecutive patients who had total ankle replacement using the Ankle Evolution System with a minimum follow-up of four years. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score and regular standardised anteroposterior and lateral weight-bearing radiographs were obtained. Patient satisfaction and complications were recorded and the survival of the implants was demonstrated by the Kaplan-Meier method. The mean follow-up was for 57.8 months (48 to 80). The cumulative survival rate at six years was 94.7% (95% confidence interval 80.3 to 98.7). The mean total AOFAS score was 88.1 (53 to 100). The mean score for pain was 35.8 (20 to 40). Ten patients presented with edge-loading of whom nine had corrective surgery. Two ankles were revised, one to an arthrodesis and the other to replace the
We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.Aims
Methods
Background. Revision total ankle arthroplasty (TAA) can be extremely challenging due to bone loss and deformity. We present the results examining the preliminary indications and short term outcomes for the use of the Salto XT revision prosthesis. Material and methods. We conducted an IRB approved prospective review revision TAA performed in two institutions using the Salto XT. There were 40 patients (24 females and 16 males with an average age of 65 years (45–83), who had undergone previous TAA (Agility 27, Salto 4, STAR 4, Buechal Pappas 1), and 4 patients who underwent staged procedures for infection. The primary indications for the revision were loosening and subsidence (34), malalignment (17), cyst formation (8), infection (4). Results. Severe bone loss of the talus (30) and distal tibia (5) caused by erosion or cysts (8) were treated with cancellous bone graft (33), cement (7), or a combination (12). A press fit of the
Introduction. Periprosthetic cyst formation following ankle replacement, requiring revision surgery, has previously been reported. The exact pathogenesis of cyst formation is unclear but considered to be due to a combination of biological and mechanical factors. Our objective was to review the incidence of periprosthetic cyst formation following Mobility ankle replacement and their outcome. Patients and methods. We reviewed all the Mobility ankle replacements performed by the senior author from Oct 2005 till May 2012. Serial radiographs were reviewed to identify the presence of cystic lesions in the tibia or the talus. Results. 124 Mobility ankle replacements were performed in 116 patients during our study period. Average age was 65 years (22 to 88) with male to female ratio of 2:1. Average follow-up was 32 months (7 to 73). Radiographic review of the most recent available radiograph showed cystic changes in the distal tibia in 10 patients (8%). One patient had cystic appearance pre-operatively which was not found to be progressive after replacement. Seven patients were asymptomatic. Three patients presented with ankle pain, which was thought to be due the cyst. One of the symptomatic patients had undergone revision of
Introduction. With increasing numbers of primary total ankle replacements being performed, the number of revision ankle surgeries is expected to rise also. We present the results of the revision procedures for failed Scandinavian total ankle replacements. Patients and methods. We retrospectively reviewed all the Scandinavian TAR done by the senior author from March 1999 till Jan 2006. Patients who underwent revision surgery were identified and their data was collected including indications for revision surgery, procedure performed, symptoms and the overall outcome. Results. 25 patients underwent revision of Scandinavian TARs between April 2000 and April 2012 out off a total of 213 primary STARs (11%). Average age was 68 years (45 to 82), with male to female ratio of 4:1. The causes of failure of primary implants included broken polyethylene inserts in 12 patients, aseptic loosening in 6 and ankle instability in 7 patients. No septic loosening was found in any of our patients. Revision procedures which were performed in these patients included exchange of inserts in 13 patients, revision of all components in 2, revision of
Introduction. Total ankle replacement (TAR) surgery remains a reasonable alternative to arthrodesis in a select group of patients with end stage ankle joint arthritis. We describe the early results of a prospective study of the first 50 Zenith total ankle replacements performed by a single surgeon (SKG). Methods. Demographic details, Visual Analogue Score (VAS) for pain (0, no pain; 10, worst possible pain), AOFAS scores, ‘would have surgery again’ and satisfaction levels were collated, pre-operatively and at their most recent outpatient review. Any post-operative complications were noted. Radiographs were also assessed for evidence of loosening, progressive osteolysis, subsidence and overall alignment of the implant. Results. One patient died at 25 months following surgery from unrelated causes. No patients have been lost to follow up. A review of 50 patients (35 males, 15 females; mean age 65 years, range 44–88 years) with a mean follow up of 30 months (range 11–48) included 48 patients with osteoarthritis and two patients with rheumatoid arthritis. There was one medial malleolar fracture at the time of surgery which required fixation and one fracture of the lateral malleolus which was picked up at the six week review. At their latest review the VAS and AOFAS score had improved significantly and 46 patients were satisfied and 4 patients unsatisfied with the outcome of surgery. One patient has cyst formation around the
Introduction. There is no published series described change in bone mineral density (BMD) after ankle replacement. We present the results of a prospective study examining the effect of total ankle replacement (TAR) upon local bone mineral density (BMD). Aim. To design a method and assess the effect of TAR loading on local ankle bones, by analysing the BMD of different area around ankle before and after Mobility TAR. Methods. 23 patients undergoing Mobility ankle arthroplasty for osteoarthritis had preoperative bone densitometry scans of the ankle, repeated at 1 and 2 years after surgery. BMD of 2 cm. 2. areas around ankle were measured. Pre- and postoperative data were compared. Results: Mean BMD within the lateral malleolus decreased significantly from 0.5g/cm. 2. to 0.42g/cm. 2. (17%, P > 0.01), at 1 & 2 years postoperatively. Mean BMD within medial malleolus decreased slightly from 0.67g/cm. 2. to 0.64 g/cm. 2. at the same period. However BMD at medial side metaphysic of tibia increased by 7%. There was little increase in BMD in tibia just proximal to implant and at talus. Discussion and Conclusion. Absence of stress shielding around distal tibia, just proximal to
To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA). A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated.Aims
Methods
The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon. We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated.Aims
Patients and Methods
Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent. A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.Aims
Patients and Methods
A failed total ankle arthroplasty (TAA) is often associated with
much bone loss. As an alternative to arthrodesis, the surgeon may
consider a custom-made talar component to compensate for the bone
loss. Our aim in this study was to assess the functional and radiological
outcome after the use of such a component at mid- to long-term follow-up. A total of 12 patients (five women and seven men, mean age 53
years; 36 to77) with a failed TAA and a large talar defect underwent
a revision procedure using a custom-made talar component. The design
of the custom-made components was based on CT scans and standard
radiographs, when compared with the contralateral ankle. After the
anterior talocalcaneal joint was fused, the talar component was
introduced and fixed to the body of the calcaneum.Aims
Patients and Methods
The last decade has seen a considerable increase
in the use of in total ankle arthroplasty (TAA) to treat patients
with end-stage arthritis of the ankle. However, the longevity of
the implants is still far from that of total knee and hip arthroplasties. The aim of this review is to outline a diagnostic and treatment
algorithm for the painful TAA to be used when considering revision
surgery. Cite this article: