Advertisement for orthosearch.org.uk
Results 1 - 20 of 183
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 147 - 147
1 Feb 2020
Yang D Huang Y Zhou Y Zhang J Shao H Tang H
Full Access

Aims. The incidence of thigh pain with the short stem varies widely across different studies. We aimed to evaluate the incidence and characteristics of post-operative thigh pain after using a particular bladed short stem and its potential risk factors. Patients and Methods. We respectively reviewed 199 consecutive patients who underwent unilateral total hip replacement using the Tri-lock stem from 2013–2016, of which 168 patients were successfully followed up with minimum two year clinical follow-up. All information about thigh pain and pre- and postoperative HHS score were gathered and all preoperative and immediate postoperative radiographs were available for review. Any complications were recorded. Results. Of the 168 patients, 34 (20.2%) patients reported thigh pain at a mean 3.1 years after surgery. Of these, 2 (5.9%) reported severe pain (NRS 5 or more). The pain was persistent (from surgery to final follow-up) in 13 patients (38.2%) and subsided within 2 years in 10 cases (29.4%). The most common site of pain was the lateral thigh (70.6%). The HHS improved from a mean 54.2 points preoperatively to 79.8 postoperatively. In 123 cases with radiographs at more than 2 years follow-up, all femoral stems were well-fixed and no revision surgery was needed at the latest. BMI and CFI were found to be independent risk factors for thigh pain after using this particular stem component. Conclusions. The incidence of thigh pain in Chinese THA patients with a bladed short stem component design is as high as 20%. Among them, nearly 40% will have some disruption in sleep or daily life. More than one-third of the cases of thigh pain were persistent. A larger BMI and patients with a funnel-type morphology of the femoral canal are independent risk factors for thigh pain in the setting of this particular stem component


Bone & Joint Open
Vol. 3, Issue 11 | Pages 907 - 912
23 Nov 2022
Hurley RJ McCabe FJ Turley L Maguire D Lucey J Hurson CJ

Aims. The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Methods. Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines. Results. Current PPE appears to mitigate more than 90% of ionizing radiation in orthopaedic fluoroscopic procedures. There is a higher exposure to the inner thigh during seated procedures. EPDs provided results for individual procedures. Conclusion. PPE currently used by surgeons in orthopaedic trauma theatre adequately reduces radiation exposure to below recommended levels. Normative data per trauma case show specific anatomical areas of higher exposure, which may benefit from enhanced radiation protection. EPDs can be used to assess real-time radiation exposure in orthopaedic surgery. There may be a role in future medical wearables for orthopaedic surgeons. Cite this article: Bone Jt Open 2022;3(11):907–912


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 46 - 46
1 Feb 2017
Kaneyama R Higashi H Yoshii H Shiratsuchi H Sasho T Suzuki T Matsuno Y Nagamine R Weijia C
Full Access

INTRODUCTION. The extension and flexion gaps are affected by different factors in total knee arthroplasty (TKA). Flexion but not extension gap measurements are influenced by posterior cruciate ligament (PCL) preservation or resection and patella reduction or eversion and thigh weight. If the flexion gap is measured with the thigh placed on the tibia, the measurement results must include the thigh weight; nevertheless, there is no detailed report regarding the thigh weight influence on the flexion gap. In this study, we investigated how thigh weight affected flexion gap measurement. METHODS. Four knees of whole-body fresh-frozen cadavers (Mongolian race) were investigated. The femur and tibia were dissected with a standard measured resection technique. After the femoral component was set, the flexion gap was measured with a knee balancer. The distraction force of 20, 30, and 40 pounds were loaded at the joint level. For each measurement, the influences of the patella reduced or everted (PR or PE) and the PCL preserved or resected (CR or PS) were estimated. The flexion gap was measured five times in four different categories (CR/PR, CR/PE, PS/PR, PS/PE) and the thigh weight was reduced by weights (0, 0.5, 1.0, 2.0, 3.0 kg) using a string and pulley system. During measurement, the femur was just placed on the tibia, and the knee flexion angle was maintained at 90 degrees with a goniometer. After all measurements, the lower limbs were resected, and the thighs were weighed with a scale. Steel-Dwasstest (non-parametric multiple comparison test) were performed for statistical analysis, and p < 0.05 was considered significant. RESULTS. Flexion gap measurement results show over 10 mm difference between the maximum gap (PS/PE, 40 lbs, 3 kg weight reduction) and the minimum gap (CR/PR, 20 lbs distraction, no weight reduction) in this study. When a 0.5 kg weight reduction was applied, there were no significant flexion gap increases compared to no weight reduction situation in almost all categories except for “CR/PR and 40 lbs distraction”. According to the increase of the weight reduction, the flexion gap became larger in all categories. When a 3 kg weight reduction was applied, there were significant flexion gap increases compared to no weight reduction situation in all categories (Table 1-3). The mean thigh weight was 2.3 kg (2.0–2.6 kg). DISCUSSION. The flexion gap is usually measured with the thigh placed on the tibia in TKA, and the measurement results are considered to include the influence of the thigh weight even though this has not been discussed in the literature. From our results, the influence of the thigh weight reduction on the flexion gap was different according to heaviness of the reduction weight. When the reduction weight was over the thigh weight, flexion gap increase relative to the flexion gap without weight reduction was significant in all categories nevertheless different situations of the PCL, patella position, and joint distraction forces. To estimate adequate flexion gap and avoid post-operative flexion gap looseness, the thigh weight should be reduced when the flexion gap is measured


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 36 - 36
1 Jan 2016
Bell C Meere P Borukhov I Rathod P Walker P
Full Access

The use of smart trial components is now allowing a better assessment of soft tissue balancing at the time of total knee replacement surgery. A balanced knee can be defined as one that possesses symmetry, ie. equal and centered lateral and medial forces through the full range of flexion. There is still a need for a standard reproducible surgical test to quickly confirm optimized balancing at surgery with such devices. The Heel Push test is the established standard, by pushing the foot in a cephalad direction while supporting the thigh and keeping the leg stable in the vertical plane. A common variation of this test is the Thigh Pull test where the foot is actively assisted during the cephalad pull of the thigh through deep flexion. The test is an open chain test. The Thigh Pull test may be an improvement since the weight of the leg is alleviated and no supplemental compressive forces are introduced. The directional changes of the lower extremity are thus a result of ligamentous tension and balances. The purpose of this study is to compare the two tests using a standard testing methodology and observe the variation in kinetic parameters in a controlled biomechanical setting. A custom l rig was developed, which independently controls all six degrees of freedom about the knee joint. In addition a commercial navigation system was used to derive instantaneous alignment values and flexion angles between the tibia and femur. The pelvis was fixed to the table and the foot was fitted onto a low friction carriage along a slide rail. The knee design used was cruciate retaining. The pressure mapping system was a wireless tibial trial that provided magnitude of load per compartment. The study is a preliminary cadaveric study reporting the data from two. In this experiment the leg was then tested with the Heel Push and Thigh Pull tests after obtaining optimum soft tissue balance of the cadaveric specimen. From this standard neutral state a series of single surgical variables were introduced to mimic common intra-operative surgical corrections. This was achieved through custom tibial liner and angle shims. The results defied theoretical anticipation. Though the total contact forces with heel push were generally higher than with thigh pull, the relative load distribution between compartments did not follow a trend (see Figure 1). Furthermore in deeper flexion the persistence of relatively high contact pressures would suggest that ligaments still generate intra-articular forces despite the much weaker gravitational effect. The clinical relevance lies in the asymmetry of the load distribution between medial and lateral compartment for the two methods tested. The load asymmetry as tested by the Thigh Pull test may correspond to an open chain in swing phase. This asymmetry would force some axial rotation and tibial femoral alignment deviation that can significantly affect the forces at the time of heel strike. The Heel Push test would be more representative of the compressive forces in a closed chain mode as seen during the stance phase of gait


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 35 - 35
1 Feb 2017
Jo W Lee Y Ha Y Koo K Lim Y Kwon S Kim Y
Full Access

Background. Although thigh pain is an annoying problem after total hip arthroplasty (THA), little information has been known about its natural course. Methods. To determine the frequency, time of onset, and duration of thigh pain after cementless THA, we evaluated 240 patients (240 hips) who underwent primary THA because of femoral head osteonecrosis with the use of a single tapered stem. Results. Twenty-seven patients (11.3%) experienced thigh pain during the follow-up of 3–11 years(mean, 84 months). The pain developed 2–78 months (median, 25 months) after THA. The 75% of pain developed within 36 months. In 25 patients, the pain disappeared postoperatively 1 month-64 months (mean, 17.4 months), and 2 patients (7.4%, 2/27) had persistent thigh pain. There were no differences in the latest Harris Hip Score between the thigh pain group and no thigh pain group. Conclusion. Our results provided basic information about the natural history of thigh pain after cementless THA with a tapered stem design


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 366 - 366
1 Dec 2013
Kaneyama R Nagamine R Weijia C Shiratsuchi H
Full Access

Objective:. Accurate measurement of the extension and flexion gap is important in total knee arthroplasty (TKA). Particularly, the flexion gap may be influenced by several factors; therefore, tension of the posterior cruciate ligament (PCL), knee extensor mechanism, and the thigh weight may need to be considered while estimating the flexion gap. However, there is no comprehensive study on the flexion gap, including an assessment of the influence of gravity on the gap. The purpose of this study is to investigate the influence of PCL, knee extensor mechanism, and thigh weight on the flexion gap by using a fresh frozen cadaver. Methods:. A fresh frozen lower limb that included the pelvis was used for the assessments. The knee was resected by a measured resection technique and a femoral component was implanted to estimate the component gap. The knee was flexed by precisely 90 degrees using a computer navigation system. The flexion gap was measured in different situations: group A, PCL preserved and patella reduced; group B, PCL preserved and patella everted; group C, PCL resected and patella reduced; and group D, PCL resected and patella everted. In each group, the measurements were obtained under 3 different conditions: 1, knee flexed and the lower limb on the operation table under gravity, as is usually done in TKA; 2, hip and knee flexed 90 degrees to avoid the influence of gravity; and 3, knee set in the same position as in condition 1 and the thigh was held by hand to reduce the influence of the thigh weight. Results:. The flexion gap differed according to groups and conditions. Group B was larger than group A in most conditions and group D was larger than group C. The flexion gap in group D was the largest among the 4 groups. The extensor mechanism had influences to the flexion gap (Table 1). In groups A and B, the flexion gaps were similar under conditions 1, 2, and 3; however, in groups C and D, the flexion gaps in condition 1 were smaller than those in conditions 2 and 3. The thigh weight condition had influences to the flexion gap when the PCL was resected (Table 2). Conclusion:. This is the first systemic report about the influences of PCL, extensor mechanism, and thigh weight on flexion gap measurement in TKA. PCL, extensor mechanism, and thigh weight influence the flexion gap and should be considered during TKA surgery. Especially, careful consideration is necessary to estimate the flexion gap when the PCL is resected and the patella is everted because the flexion gap becomes much wider than other situations


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 56 - 56
1 May 2013
Pellegrini V
Full Access

Conventional wisdom holds that aseptic failure of proximal ingrowth femoral stems should be addressed by revision to a longer femoral stem dependent upon more distal fixation. This is a reliable and time-honoured strategy with a high likelihood of success provided secure initial fixation of the revision stem is obtained. Yet, stems reliant upon more distal diaphyseal fixation are accompanied by a greater risk of physiologic thigh pain attributable to the differential in flexural stiffness of the femoral shaft compared with the prosthetic stem. Contemporary proximal ingrowth femoral stems have become the most popular device used in total hip arthroplasty and are traditionally reserved for primary procedures. Nevertheless, the flat tapered design offers a tight fit between the medial and lateral endosteal cortices of the femur, unimpeded by an increasing anteroposterior dimension of the stem, and provides a secure geometrical block to rotational movement of the stem. In instances when the primary stem is not fit to the endosteal cortex on the anteroposterior radiograph, such as with the Corail or SROM devices, the opportunity may exist for revision with a flat tapered proximal ingrowth stem that is upsized to abut the endosteal femoral cortex. Such a strategy preserves the diaphyseal femur for subsequent revision in these typically young patients and avoids the issue of thigh pain in this active population. Likewise, revision of a well-fixed long stem that is associated with unrelenting thigh pain may be similarly accomplished by revision to a flat proximal ingrowth stem provided the integrity of the upper femur can be maintained during the revision. A prophylactic cerclage wire around the proximal femur is a helpful adjunct when using flat tapered proximal ingrowth stems in the revision setting


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 509 - 509
1 Dec 2013
Rathod P Rodriguez J Cooper J
Full Access

INTRODUCTION:. Short femoral stems are receiving increasing attention for less invasive total hip replacement (THR). The purpose of this study is to report our initial experience with a short modular femoral (SMF) stem at a minimum two-year follow up. METHODS:. Twenty-six primary total hip arthroplasties (THAs) using the SMF stem were performed between August 2009 and January 2010. Patients were evaluated clinically with Harris Hip Score (HHS) and radiographically up to two years. Radiographs were analyzed to determine the degree of stem migration from its initial postoperative position. These parameters were compared to those of a cohort of 54 patients implanted with a monolithic tapered wedge stem from the same manufacturer over the same time period. RESULTS:. There were three early revisions of the femoral component for thigh pain in the SMF group, and one revision for CoCr allergy, with improvement in HHS from 60 to 89. Radiographically, 20 of 26 stems (76%) migrated into varus in the first six weeks. Of these, eight patients (29.6%) reported moderate to severe thigh pain. Radiographic evidence of isolated lateral cortical hypertrophy at the stem tip was seen in 46% of study patients, and evidence of osteointegration was seen in all cases by one year. Between one and two years post op the pain had resolved in four patients not revised. It was persistent in one patient. Comparative analysis with the control group demonstrated no significant difference in stem subsidence, but a significantly greater varus shift in coronal-plane angulation (Mean 4.3°, SD 3.8° vs. Mean 1.0°, SD 1.1°; p < 0.0001). Mean HHS was lower in the SMF group (85.2 vs. 91.4; p < 0.01) at last follow up. DISCUSSION AND CONCLUSION:. The SMF stem demonstrated a tendency towards migration into a varus position where the lateral stem touches the lateral cortex of the femur, with resulting relatively higher incidence of thigh pain and early aseptic revision


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 31 - 31
1 May 2016
Maruyama M Shimodaira H
Full Access

OBJECTIVE OF THE STUDY. The objective of this study is to establish the medium-term clinical and radiological results with the cementless three-dimensional Vektor-Titan stem compared with conventional cementless stem, such as PerFix stem. The latter stem has a double-wedge design with a rounded distal portion for canal filling (Fig. 1). MATERIALS AND METHODS. From July, 2004, to May, 2010, fifty seven Vektor-Titan stems and 150 PerFix stems were implanted for the patients with osteoarthritis, avascular necrosis, femoral neck fracture, and rheumatoid arthritis in our hospital. The results were evaluated clinically using Japanese Orthopedic Association (JOA) scores and the Merle d’Aubigne and Postel (M&P) scores. Radiographs were analyzed retrospectively. The criteria used for determining loosening were migration or a total radiolucent zone between the prosthesis/bone cement and host bone, wherein the width increased progressively or change of position, i.e., migration or subsidence of the prosthesis. Migration of the socket seen on the radiograph was defined as either the presence of a ≥2-mm position change or rotation. Position changes of the stem seen on the radiograph were defined as the presence of a progressive subsidence of ≥2 mm or change of position, e.g., varus or valgus. The follow-up period was 9.2 ± 2.6 (range, 5.0–14.0) years. RESULTS. One patient had intraoperative femoral shaft fracture and healed by conservative treatment. The mean JOA and M&P scores improved from preoperative 39.3 and 6.8 points to postoperative 90.9 and 17.2 points, respectively. Thigh pain was less frequent for Vektor-Titan stems (Table 1). Radiolucent lines was far less likely to appear for Vektor-Titan stems evaluated by Gruen's zonal analyses (Table 2). On the other hand, there were radiolucent zones of more than 90% in zone 4 with cementless PerFix stems (Table 2). There was no cases of loosening or postoperative infection. Although signs of bone atrophy were found in the proximal femur and the trochanters in 66.7 % of all cases, bone structure was radiologically normal without stress shielding in most cases (Table 2). On the contrary, there was evidence of an even denser bone structure, such as trabeculae, at the tip of the stem and the lateral implant fixation within the greater trochanter in Vektor-Titan stem cases. These findings remained unchanged over observation periods. DISCUSSION AND CONCLUSIONS. The cementless Vektor-Titan stem is made of Ti6AI7Nb, has got the shape of a straight three-dimensional cone. It has a high proximal volume in the form of a three-dimensional taper with longitudinal ribs. This design achieves strong primary fixation in the proximal metaphysis. Radiologically, newly formed trabeculae toward to the stem were indicative of direct biological fixation at the bone-implant interface. Medium-term results with the cementless Vektor-Titan stem show no implant loosening with stable metaphyseal fixation and preservation of bone structure in the proximal femur and the absence of radiolucent zones around the stem compared with conventional cementless stem


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 19 - 19
1 Jan 2022
Bishnoi A Hughes M Godsiff S
Full Access

Abstract. Background. The use of tourniquet in knee arthroplasty is common but in recent times, it has initiated a debate on its use. Complications from use of tourniquet are well documented in literature but there is less evidence on thigh pain, blood loss and length of stay post arthroplasty. Methods. We included 62 patients undergoing knee arthroplasty either Unicondylar knee arthroplasty or total knee arthroplasty. Patients were allocated randomly in tourniquet and without tourniquet groups. Half of the patients had UKA and other half TKA. Thigh pain was recorded using Visual analogue scale on day 1, 2 and on discharge. A drop in pre-operative and post operative haemoglobin level was recorded too. Independent sample t-test was done to compare the difference between the 2 groups mainly, drop in haemoglobin, thigh pain, knee pain and length of stay. Results. The mean drop in haemoglobin was comparable and was not statistically significant. Thigh pain on day 1 in no tourniquet group had a mean value of 0 and statistically significant difference in thigh pain at day 1,2 and discharge. In subgroup analysis between TKA and UKA the latter had improved results. Conclusions. Knee arthroplasty surgery without the use of tourniquet provides less thigh pain in the post-operative period and there isn't any significant difference in post op haemoglobin drop. None of the patient required any blood transfusion. A trend of early discharge was noted too but probably due to sample size, it wasn't statistically significant


Bone & Joint Open
Vol. 1, Issue 9 | Pages 585 - 593
24 Sep 2020
Caterson J Williams MA McCarthy C Athanasou N Temple HT Cosker T Gibbons M

Aims. The aticularis genu (AG) is the least substantial and deepest muscle of the anterior compartment of the thigh and of uncertain significance. The aim of the study was to describe the anatomy of AG in cadaveric specimens, to characterize the relevance of AG in pathological distal femur specimens, and to correlate the anatomy and pathology with preoperative magnetic resonance imaging (MRI) of AG. Methods. In 24 cadaveric specimens, AG was identified, photographed, measured, and dissected including neurovascular supply. In all, 35 resected distal femur specimens were examined. AG was photographed and measured and its utility as a surgical margin examined. Preoperative MRIs of these cases were retrospectively analyzed and assessed and its utility assessed as an anterior soft tissue margin in surgery. In all cadaveric specimens, AG was identified as a substantial structure, deep and separate to vastus itermedius (VI) and separated by a clear fascial plane with a discrete neurovascular supply. Mean length of AG was 16.1 cm ( ± 1.6 cm) origin anterior aspect distal third femur and insertion into suprapatellar bursa. In 32 of 35 pathological specimens, AG was identified (mean length 12.8 cm ( ± 0.6 cm)). Where AG was used as anterior cover in pathological specimens all surgical margins were clear of disease. Of these cases, preoperative MRI identified AG in 34 of 35 cases (mean length 8.8 cm ( ± 0.4 cm)). Results. AG was best visualized with T1-weighted axial images providing sufficient cover in 25 cases confirmed by pathological findings.These results demonstrate AG as a discrete and substantial muscle of the anterior compartment of the thigh, deep to VI and useful in providing anterior soft tissue margin in distal femoral resection in bone tumours. Conclusion. Preoperative assessment of cover by AG may be useful in predicting cases where AG can be dissected, sparing the remaining quadriceps muscle, and therefore function. Cite this article: Bone Joint Open 2020;1-9:585–593


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 145 - 145
1 Feb 2020
Fukunaga M Ito K
Full Access

When a knee flex deeply, the posterior side of thigh and calf contact. The contact force is unignorable to estimate the load acting on a knee because the force generates extensional moment on the knee, and the moment might be about 20–80% of the flexional moment generated by a floor reacting force. Besides, the thigh-calf contact force varies so much even if the posture or the test subject are the same that it is hard to use the average value to estimate the knee load. We have assumed that the force might change not only by the individual physical size but also by a slight change of the posture, especially the angle of the upper body. Therefore we tried to create the estimation equation for the thigh-calf contact force using both anthropometric sizes and posture angles as parameters. The objective posture was kneeling, both plantarflexing and dorsiflexing the ankle joint. Test subjects were 10 healthy males. They were asked to sit on a floor with kneeling, and to tilt their upper body forward and backward. The estimation equations were created as the linear combinations of the parameters, determining the coefficient as to minimize the root mean square errors. We used the parameters as explanatory variables which could be divided into posture parameters and individual parameters. Posture parameters included the angle of upper body, thigh and lower thigh. Individual parameters included height, weight, axial and circumferential lengths of thigh and lower thigh. The magnitude of the force was normalized by a body weight, and the acting position was expressed by the moment arm length around a knee joint and normalized by a height. As a result, the adjusted coefficient of determination improved and the root mean square error decreased when using both posture and individual parameters, though there were large errors when neglecting either parameters. The accuracy decreased little when using the same equation for plantarflexed and dorsiflexed kneeling in magnitude. The relation of measured and estimated values of the magnitude and acting position, using the common equation with all the parameters. It might be because the difference of the postures could be described by the inclination angle of a thigh. In both postures, the magnitude of a thigh-calf contact force was mainly affected by the posture and acting position by the individual parameters. When calculating the knee joint load, the errors would be about 8.59 Nm on the knee moment and 290 N on the knee load when using just an average, and they would decrease to 2.23 Nm and 74 N respectively using the estimation equation


Abstract. Source of Study: London, United Kingdom. This intervention study was conducted to assess two developing protocols for quadriceps and hamstring rehabilitation: Blood Flow Restriction (BFR) and Neuromuscular Electrical Stimulation Training (NMES). BFR involves the application of an external compression cuff to the proximal thigh. In NMES training a portable electrical stimulation unit is connected to the limb via 4 electrodes. In both training modalities, following device application, a standardised set of exercises were performed by all participants. BFR and NMES have been developed to assist with rehabilitation following lower limb trauma and surgery. They offer an alternative for individuals who are unable to tolerate the high mechanical stresses associated with traditional rehabilitation programmes. The use of BFR and NMES in this study was compared across a total of 20 participants. Following allocation into one of the training programmes, the individuals completed training programmes across a 4-week period. Post-intervention outcomes were assessed using Surface Electromyography (EMG) which recorded EMG amplitude values for the following muscles: Vastus Medialis, Vastus Lateralis, Rectus Femoris and Semitendinosus. Increased Semitendinosus muscle activation was observed post intervention in both BFR and NMES training groups. Statistically significant differences between the two groups was not identified. Larger scale randomised-controlled trials are recommended to further assess for possible treatment effects in these promising training modalities


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 43 - 43
1 Nov 2022
Nebhani N Kumar G
Full Access

Abstract. Extended Trochanteric Osteotomy (ETO) improves surgical exposure and aids femoral stem and bone cement removal in Revision Total Hip Replacement (RTHR) surgery. The aim of this study was to identify healing rates and complications of ETO in RTHR. Methods. From 2012 to 2019 we identified patients who underwent ETO for RTHR. Data collected demographics, BMI, diabetes, anticoagulants, indication for ETO, surgical approach, length of ETO and complications. Descriptive analysis of patient demographics, multiple linear regression analysis was performed to assess ETO complications. Results. There were 63 patients with an average age of 69 years. Indications for ETO were aseptic loosening (30), infection (15), periprosthetic fracture (9), recurrent dislocation (5), broken implant (4). There were 44 cemented and 19 uncemented femoral stem that underwent ETO. Average time from index surgery was 12 years (less than a year to 38 years). All procedures were through posterolateral approach and all ETO were stabilised with cables. Average length of ETO was 12.5cm. BMI varied from 18 to 37. There were 5 diabetics and 16 on anticoagulants. All but one ETO went on to unite. Other complications included infection, dislocations, lateral thigh pain and significant limp. Discussion. Fixation of ETO can be with either wires or cables or plate with cables/screws. Advantages of cables are no irritation over greater trochanter, no disruption of gluteus medius/vastus lateralis continuity, reproducible tension in cables and use of torque limiter minimises loss of tension in cables


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 100 - 100
23 Feb 2023
Tran T Driessen B Yap V Ng D Khorshid O Wall S Yates P Prosser G Wilkinson M Hazratwala K
Full Access

Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless tapered stem and 74 received a morphometric designed proximally coated tapered stem). PROMs and blood serum markers were assessed preoperatively and at intervals up to 2-years postoperatively. In addition, measures of femoral stem fit, fill and subsidence at 2-years post-operatively were measured from radiographs by three observers, with an intra-class correlation coefficient of 0.918. A mixed effects model was employed to compare the two prosthesis over the study period. A p-value <0.05 was considered statistically significant. Demographics, Dorr types and blood serum markers were similar between groups. Both stems demonstrated a significant improvement in PROMs between the pre- and post-operative measurements, with no difference at any timepoint (p > 0.05). The fully coated tapered collarless femoral stem had a non-significantly higher intra-operative femoral fracture rate (5.8% vs 1.4%, p = 0.24), with all patients treated with cable fixation and partial weight bearing. The mean subsidence at 2-years was 2.5mm +/- 2.3mm for the morphometric stem and 2.4mm +/- 1.8mm for the fully coated tapered collarless femoral stem (p = 0.879). There was one outlier in each group with increased subsidence (fully coated tapered collarless femoral stem 6.9mm, morphometric wedge stem 7.4mm), with both patients reporting thigh pain at 2 years. When compared with an established stem, the newer designed morphometric wedge stem performed well with comparable radiological and PROM outcomes at 2 year follow up. Continued follow-up is required for long term benchmarking


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 36 - 36
10 Feb 2023
Driessen B Yap V Ng D Korshid O Wall S Yates P Prosser G Wilkinson M Hazratwala K Tran. T
Full Access

Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless tapered stem and 70 received a morphometric designed proximally coated tapered stem). PROMs and blood serum markers were assessed preoperatively and at intervals up to 2-years postoperatively. In addition, measures of femoral stem fit, fill and subsidence at 2-years post-operatively were measured from radiographs by three observers, with an intra-class correlation coefficient of 0.918. A mixed effects model was employed to compare the two prostheses over the study period. A p-value <0.05 was considered statistically significant. Demographics and Dorr types were similar between groups. Both stems demonstrated a significant improvement in PROMs between the pre- and post-operative measurements, with no difference at any timepoint (p > 0.05). The fully coated tapered collarless femoral stem had a non-significantly higher intra-operative femoral fracture rate (5.8% vs 1.4%, p = 0.24), with all patients treated with cable fixation and partial weight bearing. The mean subsidence at 2-years was 2.5mm +/- 2.3mm for the morphometric stem and 2.4mm +/- 1.8mm for the fully coated tapered collarless femoral stem (p = 0.879). There was one outlier in each group with increased subsidence (fully coated tapered collarless femoral stem 6.9mm, morphometric wedge stem 7.4mm), with both patients reporting thigh pain at 2 years. When compared with an established stem, the newer designed morphometric wedge stem performed well with comparable radiological and PROM outcomes at 2 year follow up. Continued follow-up is required for long term benchmarking


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 87 - 87
1 Dec 2022
Sepehri A Lefaivre K Guy P
Full Access

The rate of arterial injury in trauma patients with pelvic ring fractures has been cited as high as 15%. Addressing this source of hemorrhage is essential in the management of these patients as mortality rates are reported as 50%. Percutaneous techniques to control arterial bleeding, such as embolization and REBOA, are being employed with increasing frequency due to their assumed lower morbidity and invasiveness than open exploration or cross clamping of the aorta. There are promising results with regards to the mortality benefits of angioembolization. However, there are concerns with regards to morbidity associated with embolization of the internal iliac vessels and its branches including surgical wound infection, gluteal muscle necrosis, nerve injury, bowel infarction, and thigh / buttock claudication. The primary aim of this study is to determine whether pelvic arterial embolization is associated with surgical site infection (SSI) in trauma patients undergoing pelvic ring fixation. This observational cohort study was conducted using US trauma registry data from the American College of Surgeons (ACS) National Trauma Database for the year of 2018. Patients over the age of 18 who were transported through emergency health services to an ACS Level 1 or 2 trauma hospital and sustained a pelvic ring fracture treated with surgical fixation were included. Patients who were transferred between facilities, presented to the emergency department with no signs of life, presented with isolated penetrating trauma, and pregnant patients were excluded from the study. The primary study outcome was surgical site infection. Multivariable logistic regression was performed to estimate treatment effects of angioembolization of pelvic vessels on surgical site infection, adjusting for known risk factors for infection. Study analysis included 6562 trauma patients, of which 508 (7.7%) of patients underwent pelvic angioembolization. Overall, 148 (2.2%) of patients had a surgical site infection, with a higher risk (7.1%) in patients undergoing angioembolization (unadjusted odds ratio (OR) 4.0; 95% CI 2.7, 6.0; p < 0 .0001). Controlling for potential confounding, including patient demographics, vitals on hospital arrival, open fracture, ISS, and select patient comorbidities, pelvic angioembolization was still significantly associated with increased odds for surgical site infection (adjusted OR 2.0; 95% CI 1.3, 3.2; p=0.003). This study demonstrates that trauma patients who undergo pelvic angioembolization and operative fixation of pelvic ring injuries have a higher surgical site infection risk. As the use of percutaneous hemorrhage control techniques increase, it is important to remain judicious in patient selection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 29 - 29
1 Dec 2022
Tyrpenou E Lee D Robbins S Ippersiel P Antoniou J
Full Access

Hip instability is one of the most common causes for total hip arthroplasty (THA) revision surgery. Studies have indicated that lumbar fusion (LF) surgery is a risk factor for hip dislocation. Instrumented spine fusion surgery decreases pelvic tilt, which might lead to an increase in hip motion to accommodate this postural change. To the best of our knowledge, spine-pelvis-hip kinematics during a dynamic activity in patients that previously had both a THA and LF have not been investigated. Furthermore, patients with a combined THA and LF tend to have greater disability. The purpose was to examine spine-pelvis-hip kinematics during a sit to stand task in patients that have had both THA and LF surgeries and compare it to a group of patients that had a THA with no history of spine surgery. The secondary purpose was to compare pain, physical function, and disability between these patients. This cross-sectional study recruited participants that had a combined THA and LF (n=10; 6 females, mean age 73 y) or had a THA only (n=11; 6 females, mean age 72 y). Spine, pelvis, and hip angles were measured using a TrakSTAR motion capture system sampled at 200 Hz. Sensors were mounted over the lateral thighs, base of the sacrum, and the spinous process of the third lumbar,12th thoracic, and ninth thoracic vertebrae. Participants completed 10 trials of a standardized sit-to-stand-to-sit task. Hip, pelvis, lower lumbar, upper lumbar, and lower thoracic sagittal joint angle range of motion (ROM) were calculated over the entire task. In addition, pain, physical function, and disability were measured with clinical outcomes: Hip Disability Osteoarthritis Outcome Score (pain and physical function), Oswestry Low Back Disability Questionnaire (disability), and Harris Hip Score (pain, physical function, motion). Physical function performance was measured using 6-Minute Walk Test, Stair Climb Test, and 30s Chair Test. Angle ROMs during the sit-to-stand-to-sit task and clinical outcomes were compared between THA+LF and THA groups using independent t-tests and effect sizes (d). The difference in hip ROM was approaching statistical significance (p=0.07). Specifically, the THA+LF group had less hip ROM during the sit-to-stand-to-sit task than the THA only group (mean difference=11.17, 95% confidence interval=-1.13 to 23.47), which represented a large effect size (d=0.83). There were no differences in ROM for pelvis (p=0.54, d=0.28) or spinal (p=0.14 to 0.97; d=0.02 to 0.65) angles between groups. The THA+LF group had worse clinical outcomes for all measures of pain, physical function, and disability (p=0.01 to 0.06), representing large effect sizes (d=0.89 to 2.70). Hip ROM was not greater in the THA+LF group, and thus this is unlikely a risk factor for hip dislocation during this specific sit-to-stand-to-sit task. Other functional tasks that demand greater excursions in the joints should be investigated. Furthermore, the lack of differences in spinal and pelvis ROM were likely due to the task and the THA+LF group had spinal fusions at different levels. Combined THA+LF results in worse clinical outcomes and additional rehabilitation is required for these patients


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 44 - 44
1 Dec 2022
Turgeon T Bohm E Gascoyne T Hedden D Burnell C
Full Access

This study used model-based radiostereometric analysis (MBRSA) to compare migration of a recently introduced cementless hip stem to an established hip stem of similar design. Novel design features of the newer hip stem included a greater thickness of hydroxyapatite coating and a blended compaction extraction femoral broach. Fifty-seven patients requiring primary total hip arthroplasty (THA) were enrolled at a single centre. Patients were randomized to receive either an Avenir collarless stem and Trilogy IT cup (ZimmerBiomet) or a Corail collarless stem and Pinnacle cup (DePuy Synthes) via a posterior or lateral approach. Both stems are broach-only femoral bone preparation. RSA beads (Halifax Biomedical) were inserted into the proximal femur during surgery. Patients underwent supine RSA imaging a 6 weeks (baseline), 6, 12, and 24 months following surgery. The primary study outcome was total subsidence of the hip stem from baseline to 24 months as well as progression of subsidence between 12 and 24 months. These values were compared against published migration thresholds for well-performing hip stems (0.5mm). The detection limit, or precision, of MBRSA was calculated based on duplicate examinations taken at baseline. Patient reported outcome measures were collected throughout the study and included the Oxford-12 Hip Score (OHS), EuroQoL EQ-5D-5L, Hip Osteoarthritis Score (HOOS) as well as visual analogue scales (VAS) for thigh pain and satisfaction. Analysis comprised of paired and unpaired t-tests with significance set at p≤0.05. Forty-eight patients (30 males) were included for analysis; 7 patients received a non-study hip stem intra-operatively, 1 patient suffered a traumatic dislocation within three weeks of surgery, and 1 patient died within 12 months post-surgery. RSA data was obtained for 45 patients as three patients did not receive RSA beads intra-operatively. Our patient cohort had a mean age of 65.9 years (±;7.2) at the time of surgery and body mass index of 30.5 kg/m2 (±;5.2). No statistical difference in total stem migration was found between the Avenir and Corail stems at 12 months (p=0.045, 95%CI: −0.046 to 0.088) and 24 months (p=0.936, 95% CI: −0.098 to 0.090). Progression of subsidence from 12-24 months was 0.011mm and 0.034mm for the Avenir and Corail groups which were not statistically different (p=0.163, 95%CI: −0.100 to 0.008) between groups and significantly less than the 0.5mm threshold (pNo statistically significant differences existed between study groups for any pre-operative function scores (p>0.05). All patients showed significant functional improvement from pre- to post-surgery and no outcome measures were different between study groups with exception of EQ-5D-5L health visual analogue scale at 12 months which showed marginally superior (p=0.036) scores in the Avenir group. This study was not powered to detect differences in clinical outcomes. This study has demonstrated no statistical difference in subsidence or patient-reported outcomes between the Corail hip stem and the more recently introduced Avenir hip stem. This result is predictable as both stems are of a triple-tapered design, are coated with hydroxyapatite, and utilize a broach-only bone preparation technique. Both stem designs demonstrate migration below 0.5mm suggesting both are low-risk for aseptic loosening in the long-term


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 28 - 28
1 Feb 2021
Domb B Annin S Diulus S Ankem H Meghpara M Shapira J Rosinsky P Maldonado D Lall A
Full Access

Background. Total hip arthroplasty (THA) has been and continues to be the gold standard for treatment of end-stage osteoarthritis. With each year, implant characteristics are evolving to increase patient-reported outcomes and decrease complications. Purpose: to report minimum 2-year outcomes and complications in patients who underwent robotic-arm assisted THA using Corin versus Stryker-type implants. Methods. Data were prospectively collected on patients who underwent THA with Corin-type implants (both cup and stem) and THA using Stryker implants between June 2011 and July 2016. A 1:1 propensity match was performed using the following 5 covariates: age, body mass index, gender, Charlson score and smoking status. Surgical outcomes were assessed at minimum 2-year follow-up using the Forgotten Joint Score (FJS), Harris Hip Score (HHS), Veterans RAND 12-item physical and mental health survey, Short Form 12 physical and mental health survey, Visual Analog Score (VAS), and patient satisfaction. The exclusion criteria were previous hip condition/surgery, workers compensation, or were unwilling. Results. Of the eligible 774 cases, 645 patients (83.3%) had minimum 2-year follow-up and met inclusion and exclusion criteria. Of the 645 patients, 323 had Corin implants, and 155 had Stryker implants. The 1:1 propensity match successfully yielded 290 patients (145 per implant group) which had a minimum 2-year follow-up at a mean 38.3 months (range, 24.1–65.3 months). Average age was 59.9 (range, 34.92–79.89 Stryker group, 30.65–75.92 Corin group) for each group and average BMI were 30.0 (range, 19.05–49.33) kg/m. 2. for the Stryker group and 29.77 (range, 20.15–55.37) kg/m. 2. for the Corin group. FJS (P=0.0388) and patient satisfaction (P=0.0019) were significantly higher in the Stryker implant group than the Corin implant group. There were nine cases of postoperative thigh numbness or paresthesias, three cases of wound infection, and one case of nonunion in the Corin-implant group. There were four cases of postoperative thigh numbness or parasthesias and six cases of wound infection in the Stryker-implant group. Conclusion. At minimum 2-year follow-up, patients who had undergone THA with Stryker-type implants had significantly higher FJS and satisfaction and a trend toward decreased complications than patients with Corin-type implants. These results can help guide decision making for surgical instrumentation by arthroplasty surgeons