Advertisement for orthosearch.org.uk
Results 1 - 20 of 132
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 230 - 234
1 Feb 2010
Anderson GA Thomas BP Pallapati SCR

Inability to actively supinate the forearm makes common activities of daily living and certain vocational activities awkward or impossible to perform. A total of 11 patients with deficient supination of the arm underwent transfer of the tendon of flexor carpi ulnaris to the split tendon of brachioradialis with its bony insertion into the radial styloid left intact. Active supination beyond neutral rotation was a mean of 37.2° (25° to 49.5°) at a minimum follow-up of three years, representing a significant improvement (95% confidence interval 25 to 50, p < 0.001). Functional evaluation of the hand after this transfer showed excellent and good results in ten patients and fair in one. The split tendon of brachioradialis as an insertion for transfer of the flexor carpi ulnaris appears to provide adequate supination of the forearm without altering the available pronation and avoids the domination of wrist extension sometimes associated with transfers of the flexor carpi ulnaris to the radial extensors of the wrist


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon. Cite this article: Bone Joint J 2013;95-B:517–22


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 668 - 670
1 May 2012
Gu YP Zhu SM

We describe a new surgical technique for the treatment of lacerations of the extensor tendon in zone I, which involves a tenodesis using a length of palmaris longus tendon one-quarter of its width. After exposing the dorsal aspect of the distal interphalangeal joint and harvesting the tendon, a 1.5 mm drill bit is passed through the insertion of the extensor tendon into the distal phalanx where it penetrates through the skin of the pulp of the digit. The palmaris longus tendon is threaded through the drill hole from dorsal to ventral and the ventral end is tied in a simple knot and trimmed. The palmaris longus tendon is then sutured to the extensor tendon close to its insertion, and also at the middle of the middle phalanx. The operation was undertaken on 67 patients: 27 with an acute injury and 40 patients with a chronic mallet deformity. One finger (or the thumb) was involved in each patient. At a mean follow-up of 12 months (6 to 18), 66 patients (98.5%) received excellent or good results according to both the American Society for Surgery of the Hand (ASSH) classification and Miller’s classification. Tenodesis using palmaris longus tendon after complete division of an extensor tendon in zone 1 is a reliable form of treatment for isolated acute or chronic ruptures


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 633 - 638
1 May 2007
Matthews TJW Smith SR Peach CA Rees JL Urban JPG Carr AJ

We have undertaken an in vivo assessment of the tissue metabolism and cellular activity in torn tendons of the rotator cuff. Cellular oxygen consumption was measured in 13 patients undergoing mini-open repair of small, medium, large and massive full-thickness tears. Measurements were also taken from three control patients who were undergoing open stabilisation of the shoulder with grossly normal tendons. The level of oxygen and nitrous oxide was measured amperometrically using silver needle microelectrodes at the apex of the tear and 1.5 cm from its edge. With nitrous oxide indicating the degree of perfusion, oxygen consumption was calculated at each location to reflect cellular activity. All of the torn tendons had lower levels of cellular activity than the control group. This activity was lower still in the tissue nearest to the edge of the tear with the larger tears showing the lowest activity. This indicated reduced levels of tissue metabolism and infers a reduction in tendon viability. Our findings suggest that surgical repair of torn tendons of the rotator-cuff should include the more proximal, viable tissue, and may help to explain the high rate of re-rupture seen in larger tears


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 370 - 377
1 Mar 2011
Chaudhury S Dicko C Burgess M Vollrath F Carr AJ

We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the rotator cuff and to identify structural differences among anatomically distinct tears. Such information may help to identify biomarkers of tears and to provide insight into the rates of healing of different sizes of tear. The infrared spectra of 81 partial, small, medium, large and massive tears were measured using FTIR and compared with 11 uninjured control tendons. All the spectra were classified using standard techniques of multivariate analysis. FTIR readily differentiates between normal and torn tendons, and different sizes of tear. We identified the key discriminating molecules and spectra altered in torn tendons to be carbohydrates/phospholipids (1030 cm. −1. to 1200 cm. −1. ), collagen (1300 cm. −1. to 1700 cm. −1. and 3000 cm. −1. to 3350 cm. −1. ) and lipids (2800 cm. −1. to 3000 cm. −1. ). Our study has shown that FTIR spectroscopy can identify tears of the rotator cuff of varying size based upon distinguishable chemical and structural features. The onset of a tear is mainly associated with altered structural arrangements of collagen, with changes in lipids and carbohydrates. The approach described is rapid and has the potential to be used peri-operatively to determine the quality of the tendon and the extent of the disease, thus guiding surgical repair


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 489 - 495
1 Apr 2006
Matthews TJW Hand GC Rees JL Athanasou NA Carr AJ

We have studied cellular and vascular changes in different stages of full thickness tears of the rotator cuff. We examined biopsies from the supraspinatus tendon in 40 patients with chronic rotator cuff tears who were undergoing surgery and compared them with biopsies from four uninjured subscapularis tendons. Morphological and immunocytochemical methods using monoclonal antibodies directed against leucocytes, macrophages, mast cells, proliferative and vascular markers were used. Histological changes indicative of repair and inflammation were most evident in small sized rotator cuff tears with increased fibroblast cellularity and intimal hyperplasia, together with increased expression of leucocyte and vascular markers. These reparative and inflammatory changes diminished as the size of the rotator cuff tear increased. Marked oedema and degeneration was seen in large and massive tears, which more often showed chondroid metaplasia and amyloid deposition. There was no association between the age of the patient and the duration of symptoms. In contrast, large and massive tears showed no increase in the number of inflammatory cells and blood vessels. Small sized rotator cuff tears retained the greatest potential to heal, showing increased fibroblast cellularity, blood vessel proliferation and the presence of a significant inflammatory component. Tissue from large and massive tears is of such a degenerative nature that it may be a significant cause of re-rupture after surgical repair and could make healing improbable in this group


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 348 - 351
1 Mar 2005
Kreuz PC Remiger A Lahm A Herget G Gächter A

We treated surgically 16 shoulders with an isolated traumatic rupture of the subscapularis tendon over a six-year period. Nine patients had a total and seven a partial tear of the subscapularis tendon. Repair was undertaken through a small deltopectoral groove approach. The mean Constant score improved in total tears from 38.7 to 89.3 points (p = 0.003) and in partial tears from 50.7 to 87.9 points (p = 0.008). The total tears were significantly more improved by surgery than the partial tears (p = 0.001). The delay between trauma and surgery was inversely proportional to the improvement in the Constant score suggesting that early diagnosis and surgical repair improves outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears. In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001). It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1610 - 1612
1 Dec 2006
Al-Rashid M Theivendran K Craigen MAC

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 767 - 770
1 Sep 1996
Le Huec JC Moinard M Liquois F Zipoli B Chauveaux D Le Rebeller A

We report ten cases of rupture of the distal part of the tendon of biceps brachii in patients aged from 27 to 58 years. MRI allowed assessment of the degree of retraction of the tendon which was related to the integrity of the bicipital expansion. When the retraction exceeded 8 cm the expansion was always ruptured. When there was doubt, or in longstanding injury, MRI allowed the lesions to be defined. Surgical repair was by reinsertion on the radial tuberosity at one or two fixation points in eight patients and reinsertion on the anterior brachial muscle in one. The other patient refused surgery. The MRI findings were confirmed at operation. Use of fixation points allowed minimal intervention, thereby reducing the risk of damaging the radial nerve. One year after operation, dynamometric evaluation of the strength of flexion and supination confirmed that the best results were obtained by reinsertion to the radial tuberosity


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 610 - 613
1 May 2008
Armstrong AL Dias JJ

We describe a new method of stabilising a painful unstable sternoclavicular joint using the sternocleidomastoid tendon and passing it through the medial clavicle and onto the manubrium sternum. This method is simple, reproducible and avoids the potential risks of reefing the joint to the first rib. The technique was used in seven cases of sternoclavicular joint instability in six patients who were reviewed at a mean of 39.7 months (15 to 63). Instability was markedly reduced or eliminated in all cases, but in one there was occasional persistant subluxation. There were minor scar complications after two procedures and one patient had transient ulnar neuritis. This procedure provides satisfactory results in the medium term


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001). In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options. Cite this article: Bone Joint J 2013;95-B:523–9


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 571 - 573
1 May 2000
Kotwal PP Gupta V Malhotra R

Giant-cell tumour of the tendon sheath, also called pigmented villonodular synovitis, is a benign tumour with a high incidence of recurrence. We have tried to identify risk factors for recurrence. Of the 48 patients included in the study, 14 received radiotherapy after surgery. Only two (4%) had a recurrence. This compares favourably with previously reported incidences of between 25% and 45%


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 424 - 425
1 Apr 2000
Ramesh R Britton JM

Over-zealous release of the first dorsal compartment of the wrist for de Quervain’s disease or other lesions such as ganglia, may result in volar subluxation of the tendons of abductor pollicis longus and extensor pollicis brevis. This is usually asymptomatic, but may occasionally become disabling. We describe an operation using part of the extensor retinaculum to stabilise such a subluxation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 208 - 212
1 Feb 2006
Habermeyer P Magosch P Rudolph T Lichtenberg S Liem D

We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42).

The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients.


Bone & Joint Research
Vol. 13, Issue 4 | Pages 169 - 183
15 Apr 2024
Gil-Melgosa L Llombart-Blanco R Extramiana L Lacave I Abizanda G Miranda E Agirre X Prósper F Pineda-Lucena A Pons-Villanueva J Pérez-Ruiz A

Aims. Rotator cuff (RC) injuries are characterized by tendon rupture, muscle atrophy, retraction, and fatty infiltration, which increase injury severity and jeopardize adequate tendon repair. Epigenetic drugs, such as histone deacetylase inhibitors (HDACis), possess the capacity to redefine the molecular signature of cells, and they may have the potential to inhibit the transformation of the fibro-adipogenic progenitors (FAPs) within the skeletal muscle into adipocyte-like cells, concurrently enhancing the myogenic potential of the satellite cells. Methods. HDACis were added to FAPs and satellite cell cultures isolated from mice. The HDACi vorinostat was additionally administered into a RC injury animal model. Histological analysis was carried out on the isolated supra- and infraspinatus muscles to assess vorinostat anti-muscle degeneration potential. Results. Vorinostat, a HDACi compound, blocked the adipogenic transformation of muscle-associated FAPs in culture, promoting myogenic progression of the satellite cells. Furthermore, it protected muscle from degeneration after acute RC in mice in the earlier muscle degenerative stage after tenotomy. Conclusion. The HDACi vorinostat may be a candidate to prevent early muscular degeneration after RC injury. Cite this article: Bone Joint Res 2024;13(4):169–183


Bone & Joint Research
Vol. 12, Issue 8 | Pages 455 - 466
1 Aug 2023
Zhou H Chen C Hu H Jiang B Yin Y Zhang K Shen M Wu S Wang Z

Aims. Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Methods. Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat were harvested at the end of the 12th week after tendon tear and analyzed biomechanically, histologically, and biochemically. Results. Histological analysis of supraspinatus muscle showed that HIIT improved muscle atrophy, fatty infiltration, and contractile force compared to the no exercise group. In the HIIT groups, supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat showed increased expression of tyrosine hydroxylase and uncoupling protein 1, and upregulated the β3AR thermogenesis pathway. However, the effect of HIIT was not present in mice injected with SR59230A, suggesting that HIIT affected muscles via β3AR. Conclusion. HIIT improved supraspinatus muscle quality and function after rotator cuff tears by activating systemic sympathetic nerve fibre near adipocytes and β3AR. Cite this article: Bone Joint Res 2023;12(8):455–466


Bone & Joint Research
Vol. 10, Issue 5 | Pages 298 - 306
1 May 2021
Dolkart O Kazum E Rosenthal Y Sher O Morag G Yakobson E Chechik O Maman E

Aims. Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model. Methods. A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks. Results. Extension of the tendon from preload to the maximum load to failure was significantly better in the PEMF-treated shoulders at three weeks compared to controls (p = 0.038). The percentage strain was significantly higher in the PEMF group at both timepoints (p = 0.037). Collagen organization was significantly better (p = 0.034) as was tissue mineral density in the PEMF-treated group at three weeks (p = 0.028). Tendon immunohistochemistry revealed a prominent increase in type I collagen at the repair site at three weeks following continuous PEMF treatment compared with controls. None of the other tested parameters differed between the groups. Conclusion. MED-generated PEMF may enhance early postoperative tendon-to-bone healing in an acute rat supraspinatus detachment and repair model. Superior biomechanical elasticity parameters together with better collagen organization suggest improved RC healing. Cite this article: Bone Joint Res 2021;10(5):298–306


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives. Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Methods. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio). Results. ICG fluorescence angiography allowed for visualization of blood flow in the rotator cuff in all groups. The adhesive capsulitis group showed significantly earlier enhancement than the other groups. Furthermore, the adhesive capsulitis group had a significantly smaller hypovascular area ratio than the other groups. Conclusion. ICG fluorescence angiography allowed for evaluation of real-time blood flow of the rotator cuff in arthroscopic shoulder surgery. The techniques of ICG fluorescence angiography are simple and easy to observe, observer reliability is high, and it has utility for evaluating blood flow during surgery. Cite this article: N. Doi, T. Izaki, S. Miyake, T. Shibata, T. Ishimatsu, Y. Shibata, T. Yamamoto. Intraoperative evaluation of blood flow for soft tissues in orthopaedic surgery using indocyanine green fluorescence angiography: A pilot study. Bone Joint Res 2019;8:118–125. DOI: 10.1302/2046-3758.83.BJR-2018-0151.R1