Adult Spine Deformity (ASD) is a degenerative condition of the adult spine leading to altered spine curvatures and mechanical balance. Computational approaches, like Finite Element (FE) Models have been proposed to explore the etiology or the treatment of ASD, through biomechanical simulations. However, while the personalization of the models is a cornerstone, personalized FE models are cumbersome to generate. To cover this need, we share a virtual cohort of 16807 thoracolumbar spine FE models with different spine morphologies, presented in an online user-interface platform (SpineView). To generate these models, EOS images are used, and 3D surface spine models are reconstructed. Then, a Statistical Shape Model (SSM), is built, to further adapt a FE structured mesh template for both the bone and the soft tissues of the spine, through mesh morphing. Eventually, the SSM deformation fields allow the personalization of the mean structured FE model, leading to generate FE meshes of thoracolumbar spines with different morphologies. Models can be selectively viewed and downloaded through SpineView, according to personalized user requests of specific morphologies characterized by the geometrical parameters: Pelvic Incidence; Pelvic Tilt; Sacral Slope; Lumbar Lordosis; Global Tilt; Cobb Angle; and GAP score. Data quality is assessed using visual aids, correlation analyses, heatmaps, network graphs, Anova and
To analyse bone stresses in humerus-megaprosthesis construct in response to axial loading under varying implant lengths in proximal humeral replacement following tumour excision. CT scans of 10 cadaveric humeri were processed in 3D Slicer to obtain three-dimensional (3D) models of the cortical and cancellous bone. Megaprostheses of varying body lengths (L) were modelled in FreeCAD to obtain the 3D geometry. Four FE models: group A consisting of intact bone; groups B (L=40mm), C (L=100mm) and D (L=120mm) comprising of humerus-megaprosthesis constructs were created. Isotropic linear elastic behaviour was assigned for all materials. A tensile load of 200N was applied to the elbow joint surface with the glenohumeral joint fixed with fully bonded contact interfaces. Static analysis was performed in Abaqus. The bone was divided at every 5% bone length beginning distally. Statistical analysis was performed on maximum von Mises stresses in cortical and cancellous bone across each slice using one-way ANOVA (0-45% bone length) and paired
The current study aims to compare the clinico radiological outcomes between Non-Fusion Anterior Scoliosis (NFASC) Correction and Posterior Spinal Fusion (PSF) for Lenke 5 curves at 2 years follow up. Methods:38 consecutive Lenke 5 AIS patients treated by a single surgeon with NFASC (group A) or PSF (group B) were matched by age, Cobb's angle, and skeletal maturity. Intraoperative blood loss, operative time, LOS, coronal Cobbs, and SRS22 scores at 2 years were compared. Flexibility was assessed by modified Schober's test. Continuous variables were compared using student
Abstract. Objectives. Little is known about the impact of cartilage defects on knee joint biomechanics. This investigation aimed to determine the gait characteristics of patients with symptomatic articular cartilage lesions of the knee. Methods. Gait analyses were performed at the Regional North-West Joint Preservation Centre. Anthropometric measurements were obtained, then 16 retroreflective markers representing the Plug-in-Gait biomechanical model were placed on pre-defined anatomical landmarks. Participants walked for two minutes at a self-selected speed on a treadmill on a level surface, then for 2 minutes downhill. A 15-camera motion-capture system recorded the data. Knee kinematics were exported into Matlab to calculate the average kinematics and spatiotemporal parameters per patient across 20 gait cycles. Depending on the normality of the data, paired
Abstract. Objectives. Direct ink writing (DIW) has gained considerable attention in production of personalized medical implants. Laponite nanoclay is added in polycaprolactone (PCL) to improve printability and bioactivity for bone implants. The 3D structure of DIW printed PCL/Laponite products was qualitatively evaluated using micro-CT. Methods. PCL/LP composite ink was formulated by dissolving 50% m/v PCL in dichloromethane with Laponite loading of up to 30%. The rheological properties of the inks were determined using Discovery HR-2 rheometer. A custom-made direct ink writer was used to fabricate both porous scaffold with 0°/90° lay-down pattern, and solid dumbbell-shaped specimens (ASTM D638 Type IV) with two printing orientations, 0° and 90° to the loading direction in tensile testing. The 3D structure of specimens was assessed using a micro-CT. Independent
Abstract. Objectives. The objective of this study was to determine the kinematic factor(s) underlying the reduction in walking velocity displayed by total hip arthroplasty (THA) patients in comparison to healthy controls during walking gait. Methods. Eleven patients with well-functioning THA (71 ± 8 years, Oxford Hip Score = 46 ± 3) and ten healthy controls (61 ± 5 years) participated within this study. Sagittal plane lower limb kinematics were captured using a 10 camera Qualisys motion capture system, sampling at 200Hz, as participants walked overground at a self-selected pace. Bivariate linear regression was used to explore the relationship between walking velocity and a number of kinematic variables in a deterministic manner. Kinematic variables significantly associated with walking velocity were compared between THA and healthy groups utilising independent samples
Abstract. OBJECTIVES. Although surgical periacetabular osteotomy (PAO) for hip dysplasia aims to optimise acetabular coverage and restore hip function, it is unclear how surgery affects capsular mechanics and joint stability. The purpose was to examine how the reoriented acetabular coverage affects capsular mechanics and joint stability in dysplastic hips. METHODS. Twelve cadaveric dysplastic hips (n = 12) were denuded to the capsule and mounted onto a robotic tester. The robot positioned each hip in multiple flexion angles (Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°) and performed internal-external rotations and abduction-adduction to 5 Nm in each rotational or planar direction. Each hip underwent a PAO, preserving the capsule, and was retested postoperatively in the robot. Paired sample
Abstract. OBJECTIVES. Cam femoroacetabular impingement (FAI – femoral head-neck deformity) and developmental dysplasia of the hip (DDH – insufficient acetabular coverage) constitute a large portion of adverse hip loading and early degeneration. Spinopelvic anatomy may play a role in hip stability thus we examined which anatomical relationships can best predict range of motion (ROM). METHODS. Twenty-four cadaveric hips with cam FAI or DDH (12:12) were CT imaged and measured for multiple femoral (alpha angles, head-neck offset, neck angles, version), acetabular (centre-edge angle, inclination, version), and spinopelvic features (pelvic incidence). The hips were denuded to the capsule and mounted onto a robotic tester. The robot positioned each hip in multiple flexion angles (Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°); and performed internal-external rotations to 5 Nm in each position. Independent
Autologous micro-fragmented adipose tissue (MFAT) for the treatment of symptomatic knee osteoarthritis (OA) is gaining interest although there is still a lack of supportive data on safety and clinical efficacy. This study primarily aimed to identify patient- and pathology-related parameters to tighten patient selection criteria for future clinical MFAT application. Secondly, the overall (1) therapeutic response rate (TRR), (2) short-term clinical effect, (3) effect durability and (4) therapeutic safety was investigated at a minimal follow-up of 1 year. Sixty-four subjects (91 knees) with symptomatic knee OA (mild-severe on MRI) were enrolled in a prospective single-centre case series. Ethical approval was obtained from the local and academic ethical committee (#B300201733775). After liposuction, the adipose tissue was mechanically processed in a Lipogem® device which eventually produced 6–9cc MFAT. Subjects were clinically assessed by means of the KOOS, NRS, UCLA and EQ-5D at baseline and 1, 3, 6 and 12 months after injection. Adverse events were meticulously recorded. The TRR was defined according to the OMERACT-OARSI criteria. A baseline MRI was scored following the MOAKS system. Paired sample
We hypothesized that using the navigation system, intra-operative knee kinematics after implantation measured may predict that post-operative kinematic in activities of daily living. Our aim was to compare intra-operative knee kinematics by a computed tomography (CT)-based navigation system and post-operative by the 2- to 3-dimensional registration techniques (2D3D). This study were performed for 8 patients (10 knees, medial osteoarthritis) who underwent primary PS TKA using CT-based navigation system. The median follow-up period from operation date to fluoroscopic surveillance date was 13 months (range 5 – 37 months). Navigation and 2D3D had a common coordinate origin for components. Medial and lateral femoral condyle anterior-posterior translation (MFT and LFT) were respectively defined as the distance of the projection of the points (which was set on the top of the posterior femoral pegs) onto the axial plane of the tibial coordinate system. Intraoperative kinematics was measured using the navigation system after final implantation and closure of the retinaculum during passive full flexion and extension imposed by the surgeon. Under fluoroscopic surveillance in the sagittal plane, each patient was asked to perform sequential deep knee flexion under both weight bearing (WB) and non-weight bearing (NWB) conditions from full extension to maximum flexion. Repeated two-way ANOVA (tasks × flexion angles) were used, and then post-hoc test (paired
The aim of this study was to report the procedure survival and patient-reported outcomes in a consecutive series of patients <50yrs at the time of hip arthroplasty with a metal-on-metal hip resurfacing system who have progressed to a minimum of 10yrs follow-up. Patients presenting for treatment of degenerative conditions of the hip electing to undergo hip resurfacing were included in a clinical registry (N=226 patients; 238 procedures). Procedure survival was confirmed by crosschecking to the Australian Orthopaedic Association National Joint Replacement Registry and comparing to all procedures by other surgeons nationwide. Kaplan-meier survival curves with 95% confidence intervals were constructed, while patient-reported outcome measures were compared with
This investigation of elite male collegiate basketball players aims to determine 1) the change in 3D dynamic functional variables across a single season and 2) correlate cross-season changes in functional variables with changes in clinical and quantitative ultrasound measures. Eleven male college basketball players (mean age 19, range 18–21 years) from a single team underwent baseline patellar tendon shear wave (SW) elastography and dynamic function at the start of the season (Visit1) and at a late-season time point (Visit2). Players reported their VISA-P scores every two weeks across their 24-week season. Each athlete performed a box-ground-box jump five times while 3D lower extremity kinematic and kinetic variables were collected. Functional measures included for landing (LAND) and take-off (TOFF) phases: knee valgus angle, valgus torque, and peak limb force. Knee valgus angular impulse and ground contact time were also measured. Paired
Objectives. Whilst gait speed is variable between healthy and injured adults, the extent to which speed alone alters the 3D in vivo knee kinematics has not been fully described. The purpose of this prospective study was to understand better the spatiotemporal and 3D knee kinematic changes induced by slow compared with normal self-selected walking speeds within young healthy adults. Methods. A total of 26 men and 25 women (18 to 35 years old) participated in this study. Participants walked on a treadmill with the KneeKG system at a slow imposed speed (2 km/hr) for three trials, then at a self-selected comfortable walking speed for another three trials. Paired
Instability accounts for approximately 20% of all revision total knee arthroplasty (TKA), however diagnostic tests remain crude and subjective. The aim of this examination was to evaluate the feasibility of pressure mat (SB Mat, TekScan) analyses of functional tasks to differentiate instability in a clinical setting. Five patients (M = 4; age = 69.80±7.05 years; weight = 79.73±20.12 kg) with suspected TKA instability were examined compared to five healthy controls (M = 1; age = 46.80±7.85 years; weight = 71.54±16.17 kg). Peak pressure and time parameters were measured during normal gait and two-minute bilateral stance. Side-to-side pressure distribution was calculated over 10-second intervals during the second minute. Pressure distributions were expressed relative to bodyweight (%BW).
Introduction Leg length inequalities (LLIs) are a common finding in every orthopaedic practice. They can be classified into anatomical and functional LLIs. LLIs can e.g. cause gait and balance disabilities, low back pain and functional scoliosis of the spine. In patients with a total hip replacement a higher rate of aseptic loosening of the prosthesis was found when LLIs were present (Gurney 2002). Until today LLIs are treated statically by wooden blocs, which are placed under the shorter extremity, until the pelvis is levelled. However, the correction of LLIs should also be evaluated dynamically to examine the influence of correction onto the spine and pelvis during gait. Therefore, we seek to evaluate in this pilot study the influence of simulated LLIs on spine and pelvis during gait. Methods A total of 30 healthy subjects (17 females & 13 males) with an average age of 24.4 years were measured in this study. First, LLIs (1 to 4 cm) were simulated with the subjects standing on a simulation platform, which height could be controlled, as previously described (Betsch 2012). In addition, a specially designed sandal with different insole heights (1 to 4 cm) was used to simulate LLIs under dynamic condition while subjects were walking on a treadmill. Changes in pelvic position and spinal posture caused by the LLIS were measured using a rasterstereographic system (Formetric 4D motion, Diers International GmbH, Germany). All data were checked for Gaussian distribution by the Chi square test. Student
Background. Some models of knee osteoarthritis (OA) suggest that the properties of knee tissues are adapted in healthy joints, and that OA development is due to a breakdown in the equilibrium among tissue properties. Cartilage thickness and bone density are particularly important properties in this regard because both are related to the mechanical environment. This study tested the hypothesis that locations of thickest cartilage are associated with locations where bone density is the highest in non-OA tibias. Method. CT-arthrography was performed on six non-OA subjects (2 males; 58± 15 years old). Images were segmented to build 3D models of the bone and cartilage structures. Maps of cartilage thickness were calculated for the medial and lateral subchondral bone areas by measuring the distance between bone and cartilage structures. Bone density maps were calculated based on the intensity of the CT-arthrography signal in the first 3mm of bone. The location of thickest cartilage and most dense bone were measured in the medial and lateral compartments. These locations were then normalised, and paired
Background. New marker free motion analysis systems are being used extensively in the area of sports medicine and physiotherapy. The accuracy and validity of use in an orthopaedic setting have not been fully assessed for these newer marker free motion analysis systems. The aim of this study is to compare leg length and varus/valgus knee measurements performed by leg measurement x-ray, and performed using the new marker free motion analysis system (Organic motion biostage). Methods. Patients attending the orthopaedic department for total knee replacements were recruited. They underwent radiological leg measurement x-ray, clinical leg measurement, and finally assessment using the organic motion biostage system. These were analysed using the motion monitor software, microsoft excel and minitab 16. Results. For 23 patients assessed, all methods showed a statistically significant result (p<0.05) using paired
Patellofemoral pain syndrome (PFPS) is a common knee disorder in active individuals. Movement dysfunction of valgus positioning at the knee during weight-bearing is frequently seen in PFPS. A single-leg squat (SLS) is a test commonly used in physiotherapy to assess for movement dysfunction. Kinesio-Tape (KT) is gaining in popularity in treating PFPS and claims to alter muscle recruitment and motor control, however evidence is weak. Objective: To evaluate the effect of KT applied to the quadriceps on muscle activity with electromyography (EMG) of the rectus femoris, vastus lateralis and vastus medialis oblique and motor control via the frontal plane projection angle (FPPA) using 2-dimensional video analysis. A convenience sample of healthy females were recruited and performed 5 single-leg squats with and without KT. EMG of the quadriceps was recorded and dynamic valgus assessed via the FPPA using Dartfish video analysis software. Eccentric and concentric EMG data was recorded and the FPPA measured in single-leg stance and the depth of the squat. Institutional ethical approval was obtained for the study. 16 active females were assessed (mean age 28.94 +6.58 years). Wilcoxon signed-rank tests found no significant change in eccentric or concentric EMG of the quadriceps (%MVC) with KT compared to without (p values 0.35–0.86). Paired-sample
Objectives. To assess the clinical and cost-effectiveness of a virtual fracture clinic (VFC) model, and supplement the literature regarding this service as recommended by The National Institute for Health and Care Excellence (NICE) and the British Orthopaedic Association (BOA). Methods. This was a retrospective study including all patients (17 116) referred to fracture clinics in a London District General Hospital from May 2013 to April 2016, using hospital-level data. We used interrupted time series analysis with segmented regression, and direct before-and-after comparison, to study the impact of VFCs introduced in December 2014 on six clinical parameters and on local Clinical Commissioning Group (CCG) spend. Student’s
Background. Recent studies have suggested that full-limb radiographs are more accurate and sensitive than short film radiographs for pre-operative measurement of the anatomical angles required to achieve optimal knee alignment in Total Knee Arthroplasty (TKA). However, there are drawbacks associated with their use including excess radiation to the pelvic organs, the need for specialised radiography equipment and increased cost. Given these drawbacks, we compared the use of MRI scans, a commonly performed pre-operative investigation, with short film knee radiographs for measurement of knee alignment. Objective. To investigate whether knee alignment measurements made on MRI scans correlate with those measured on short film knee radiographs in patients with osteoarthritic knees. Methods. We retrospectively reviewed short film knee radiographs and MRI scans of 50 patients with knee osteoarthritis. The plain radiographs had to be performed whilst weight bearing. The MRI scans were performed supine and non-weight bearing. The exclusion criteria included previous trauma to the knee, previous TKA and previous fracture of the lower limb. 4 angle measurements defined by The American Knee Society: alpha, beta, sigma and gamma were measured using each of the 2 modalities. Kolmogorov-Smirnov and two- tailed paired