Background. Establishing the diagnosis in a child presenting with an atraumatic limp can be difficult. Clinical prediction algorithms have been devised to distinguish septic arthritis (SA) from transient
The opposable thumb is one of the defining characteristics of human anatomy and is involved in most activities of daily life. Lack of optimal thumb motion results in pain, weakness, and decrease in quality of life. First carpometacarpal (CMC1) osteoarthritis (OA) is one of the most common sites of OA. Current clinical diagnosis and monitoring of CMC1 OA disease are primarily aided by X-ray radiography; however, many studies have reported discrepancies between radiographic evidence of CMC1 OA and patient-related outcomes of pain and disability. Radiographs lack soft-tissue contrast and are insufficient for the detection of early characteristics of OA such as
Introduction:. The earliest evidence of particle-induced response is found in the synovium, leading to osteolytic defect. The degree of
A patient in his thirties developed
Introduction. Persistent pain after medial unicompartmental knee arthroplasty (UKA) is a prevailing reason for revision to total knee arthroplasty (TKA). Many of these pathologies can be addressed arthroscopically. The purpose of this study is to examine the outcomes of patients who undergo an arthroscopy for any reason after medial UKA. Methods. A query of our practice registry revealed 58 patients who had undergone medial UKA between October 2003 and June 2015 with subsequent arthroscopy. Mean interval from UKA to arthroscopy was 22 months (range, 1–101 months). Indications for arthroscopy were acute anterior cruciate ligament tear (1), arthrofibrosis (7),
Purpose of the Study:. Spontaneous intraarticular haemorrhages are the most frequent bleeding episodes encountered in the haemophiliac population, causing pain, joint deformity and arthropathy. Chronic haemophiliac arthropathy is characterised by persistent joint swelling, proliferative
This case series highlights the use of the Ganz approach (trochanteric slide approach) and surgical dislocation for excision of fibrous dysplasia of the femoral neck, pigmented villonodular
Aberrant infrapatellar fat metabolism is a notable feature provoking inflammation and fibrosis in the progression of osteoarthritis (OA). Irisin, a secretory subunit of fibronectin type III domain containing 5 (FNDC5) regulate adipose morphogenesis, energy expenditure, skeletal muscle, and bone metabolism. This study aims to characterize the biological roles of Irisin signaling in an infrapatellar fat formation and OA development. Injured articular specimens were harvested from 19 patients with end-stage knee OA and 11 patients with the femoral neck fracture. Knee joints in mice that overexpressed Irisin were subjected to intra-articular injection of collagenase to provoke OA. Expressions of Irisin, adipokines, and MMPs probed with RT-quantitative PCR. Infrapatellar adiposity, articular cartilage damage, and synovial integrity verified with histomorphometry and immunohistochemistry. Infrapatellar adipose and synovial tissues instead of articular cartilage exhibited Irisin immunostaining. Human OA specimens showed 40% decline in Irisin expression than the non-OA group. In vitro, the gain of Irisin function enabled synovial fibroblasts but not chondrocytes to display minor responses to the IL-1β provocation of MMP3 and MMP9 expression. Of note, Irisin signaling reduced adipogenic gene expression and adipocyte formation of mesenchymal progenitor cells. In collagenase-mediated OA knee pathogenesis, forced FNDC5 expression in articular compromised the collagenase-induced infrapatellar adipose hypertrophy, synovial hypercellularity, and membrane hyperplasia. These adipose-regulatory actions warded off the affected knees from cartilage destruction and gait aberrance. Likewise, intra-articular injection of Irisin recombinant protein mitigated the development of infrapatellar adiposity and
Purpose of study:. “Ganglia are a benign condition taking up the time of competent surgeons who might be more usefully engaged.” – McEvedy. Our aim was to perform a retrospective review comparing preoperative clinical presentation, intraoperative findings and histological diagnosis of all hand and wrist ganglia presenting to the Hand Unit at Chris Hani Baragwanath Hospital. Methods:. A retrospective review of hand and wrist ganglia treated at the Hand Unit at Chris Hani Baragwanath Hospital. Clinical and surgical notes and histology reports were reviewed. All ganglia were removed surgically as directed by clinical findings. Results:. A total of 75 hand and wrist masses were operated over a period of 6 months between January and June 2012. Of these 42 were clinically diagnosed as ganglia. All 42 “ganglia” were removed surgically and sent for histological evaluation. Of these, 40 were diagnosed intra-operatively as ganglia. In 2 cases the diagnoses were changed intra-operatively to
Two big problems exist with the all polyethylene cemented tibial component; the polyethylene and the cement. The polyethylene is too weak and flexible to bear high tibial load, so it deforms and loosens. The interface stresses are too high when two flexible structures are poorly bonded and heavily loaded. Modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80's for versatility and to facilitate screw fixation for cementless implants. These designs allow exchange of various polyethylene thicknesses, and aids the addition of stems and wedges. Other advantages include the reduction of inventory, and the potential for isolated tibial polyethylene exchanges as a simpler revision procedure. Several studies have documented the high failure rate of isolated polyethylene exchange procedures, because technical problems related to the original components are left uncorrected. However, revision for wear is the simplest revision ever!. Since the late 1980's the phenomena of polyethylene wear and osteolysis have been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of
Introduction and aim. TKR remains one of the most successful surgeries in orthopedics. Still a sizeable number of patients remain dissatisfied reaching to a level of 30%. Our aim was to examine the excised synovium from the suprapatellar region in all osteoarthritic knees and evaluate the histopathological report to know if in a few cases the unrelenting pain and discomfort could be due to some undiagnosed pathology within the joint. Materials and Methods. We selected 40 consecutive knees at our institution operated from Oct 2014 to Jan 2015. Of the total knees 7 patients were operated as single stage bilateral TKR. Supra patellar synovium was thoroughly excised and sent for histopathology examination. Patients who were clinically, serologically and radiologically diagnosed as rheumatoid arthritis or sero negative arthritis were excluded. The implant used was Maxx Freedom knee (PS design). Results. We found abnormal reports in 8 of our 40 knees (20%). 6 of these were proven to be rheumatoid arthritis whilst 2 of the knees showed chronic villous
Introduction. Instability, loosening, and patellofemoral pain belong to the main causes for revision of total knee arthroplasty (TKA). Currently, the diagnostic pathway requires various diagnostic techniques such as x-rays, CT or SPECT-CT to reveal the original cause for the failed knee prosthesis, but increase radiation exposure and fail to show soft-tissue structures around TKA. There is a growing demand for a diagnostic tool that is able to simultaneously visualize soft tissue structures, bone, and TKA without radiation exposure. MRI is capable of visualising all the structures in the knee although it is still disturbed by susceptibility artefacts caused by the metal implant. Low-field MRI (0.25T) results in less metal artefacts and offers the ability to visualize the knee in weight-bearing condition. Therefore, the aim of this study is to investigate the possibilities of low field MRI to image, the patellofemoral joint and the prosthesis to evaluate the knee joint in patients with and without complaints after TKA. Method. Ten patients, eight satisfied and two unsatisfied with their primary TKA, (NexGen posterior stabilized, BiometZimmer) were included. The patients were scanned in sagittal, coronal, and transversal direction on a low field MRI scanner (G-scan Brio, 0.25T, Esaote SpA, Italy) in weight-bearing and non-weight-bearing conditions with T1, T2 and PD-weighted metal artefact reducing sequences (TE/TR 12–72/1160–7060, slice thickness 4.0mm, FOV 260×260×120m. 3. , matrix size 224×216). Scans were analysed by two observers for:. - Patellofemoral joint: Caton-Descamps index and Tibial Tuberosity-Trochlear Groove (TT-TG) distance. - Prosthesis malalignment: femoral component rotation using the posterior condylar angle (PCA) and tibial rotation using the Berger angle. Significance of differences in parameters between weight-bearing and non-weight-bearing were calculated with the Wilcoxon rank test. To assess the reliability the inter and intra observer reliability was calculated with a two-way random effects model intra class correlation coefficient (ICC). The two unsatisfied patients underwent revision arthroplasty and intra-operative findings were compared with MRI findings. Results. In the satisfied group, a significant difference was found between TT-TG distance in non-weight-bearing and weight-bearing condition (p=0.018), with a good interrater reliability ICC=0.89. Furthermore, differences between weight-bearing and non-weight-bearing were found for the CD ratio, however, not significant (p=0.093), with a good interrater reliability ICC=0.89. The Berger angle could be measured with an excellent interrater reliability (ICC=0.94). The PCA was hard to assess with a poor interrater reliability (ICC=0.48). For one unsatisfied patient a deviation was found for tibial component rotation, according to the perioperative findings as, ‘malposition of the tibial component’. For the other unsatisfied patient revision surgery was performed due to aseptic loosening in which the MRI showed a notable amount of
Aim. This study aims to determine the value of MRI in children with hip pain which remained unexplained following routine investigations including ultrasound examination. Materials and methods. Retrospective review of clinical notes and MRI findings in all children who received and MRI scan for undiagnosed hip pain over three years. Results. Fifty five children underwent an MRI scan of their hips for unexplained hip pain. 29 were male and 26 were female. The mean age was 10.9 years. The MR study provided a diagnosis in 22 children (40%), and was normal in 33 children (60%). Five cases were considered to be due to transient
Introduction. The purpose of this study was to assess the rate of revision subacromial decompression and identify different pathologies. Materials/Methods. We analysed the patients who underwent Revision Arthroscopic Subacromial decompression from our prospective database of shoulder patients. Between April 2003 and Dec 2010, 797 patients underwent arthroscopic subacromial decompression. Patients who underwent any other procedure i.e. biceps tenotomy, capsular release, cuff repair were excluded from the study. Of these, 37 underwent a revision subacromial decompression (Revision rate 4.6%). The indication for revision procedure was persistent pain or restricted movements not responding to physiotherapy and injections. Results. We found that 1) Patients having cuff pathology i.e. partial tear or degenerate cuff were more likely to need a revision procedure (11/37 and 92/797, p = 0.001). 2) The rate of ACJ excision done for residual pain after primary subacromial decompression was similar to the rate of ACJ excision at the time of the primary procedure (7/37 vs. 100/797, p= 0.5). 3) Presence of Calcific deposits did not have any influence on the risk of having a revision procedure (2/37 and 12/797, p= 0.1). 4) Patients found to have
Background. Cartilage lesions in chronic lateral ligament deficiency are common with the incidence rates mentioned in the previous literature up to 30%. However, other intra-articular pathologies in the unstable ankle have received little attention. Anterolateral impingement associated with
Introduction:. Unicompartmental knee arthroplasty (UKA) is a well established method for treatment of single compartment arthritis. However, a subset of patients still present with continued pain after their procedure in the setting of a normal radiographic examination. We propose the use of magnetic resonance imaging (MRI) as a useful modality in determining the etiology of symptoms in symptomatic unicompartmental knee arthroplasties. Materials & Methods:. An IRB-approved retrospective analysis of 300 consecutive unicompartmental knee arthroplasties between 2008–2010 found 28 cases symptomatic for continued pain. Magnetic resonance imaging was performed with a 1.5 T Surface Coil unit after clinical and radiographic assessment. MRI evaluation included assessment for osteoarthritis,
Two big problems exist with the all-polyethylene cemented tibial component; the polyethylene and the cement. The polyethylene is too weak and flexible to bear high tibial load, so it deforms and loosens. The interface stresses are too high when two flexible structures are poorly bonded and heavily loaded. Modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80's for versatility and to facilitate screw fixation for cementless implants. These designs allow exchange of various polyethylene thicknesses, and aids the addition of stems and wedges. Other advantages include the reduction of inventory, and the potential for isolated tibial polyethylene exchanges as a simpler revision procedure. Several studies have documented the high failure rate of isolated polyethylene exchange procedures, because technical problems related to the original components are left uncorrected. However, revision for wear is the simplest revision ever!. Since the late 1980's the phenomena of polyethylene wear and osteolysis has been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of
Two big problems exist with the all-polyethylene cemented tibial component; the polyethylene and the cement. The polyethylene is too weak and flexible to bear tibial load, so it deforms and loosens. The interface stresses are too high when two flexible structures are poorly bonded and heavily loaded. Modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-1980s for versatility and to facilitate screw fixation for cementless implants. These designs allow exchange of various polyethylene thicknesses, and aid the addition of stems and wedges. Other advantages include the reduction of inventory, and the potential for isolated tibial polyethylene exchanges as a simpler revision procedure. Several studies have documented the high failure rate of isolated polyethylene exchange procedures, because technical problems related to the original components are left uncorrected. However, revision for wear is the simplest revision ever!. Since the late 1980s the phenomena of polyethylene wear and osteolysis have been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of
Introduction. We previously reported a 28% short-term corrosion-related revision rate of recalled Rejuvenate modular stem. The purpose of this study was to assess the mid-term clinical results and survivorship of this implant. Methods. Between June 2009 and July 2012, 73 total hip arthroplasty (THA) in 63 patients with the Rejuvenate modular neck implant were performed by a single surgeon and prospectively followed. Average age was 63.2 ± 12.6 years (28 to 86). Elevated metal ion (= 2 µg/L), pain, or positive MRI findings were indication for revision surgery. Correlation between patient factors with serum metal ion levels and revisions were analyzed. Results. At an average follow-up of 4.2 ± 0.6 years (3.0 to 5.5), 57 hips (48 patients, 78%) were revised at mean of 3.2 ± 1 years (1 to 5.5); and 6 other have been scheduled for surgery. The Kaplan-Meier survivorship was 22 % at 5.5 years. Visible corrosion was seen at the trunion-stem junction in each revision case. 51 of 57 hips undergoing revision (89%), had elevated preoperative serum Co levels, 24 (42%) had elevated preoperative Cr. The average serum Co and Cr ion levels prior to revision surgery were 10 ± 8 µg/L (0.3 to 40) and 2.3 ± 1.5 µg/L (1 to 7.4), respectively. There was a significant correlation between revision surgery and younger age (p=0.0137). 52 hips underwent MRI evaluation, 22 hips (42%) had positive findings correlated to pain (p=0.025): 11 hips demonstrated adverse local soft tissue reactions such as fluid collection, capsular thickening, osteolysis, or
Juvenile idiopathic arthritis(JIA) is chronic inflammation commonly occurs in early childhood. Recently, biological therapies are used in JIA at the early stage as same as rheumatoid arthritis, due to retain joint cartilage. However, some of young patients have painful knee problems requiring knee replacement. We experienced 4 cases of JIA treated by knee arthroplasty. The average age at surgery was 33.5 years (range, 26–38 years) with a mean follow-up of 9.5 years (range, 5–18 years). We evaluated the knee range of motion and functional outcomes by the Knee Society Score (KSS), implant selection, postoperative complication, surgery of another joint. Mean range of motion improved from 76.3° (0°–120°) at pre-operation to 110.6° (80°–130°) at post-operation (P<0.05). Mean KSS increased from 47.3 ±20.1 preoperatively to 86.9 ±11.1 (P<0.01) at last follow-up and the mean KSS function from 27.5 ±25.9 to 62.5±20.2 at last follow-up (P<0.05). All of the TKAs were cemented, 5 were cruciate-retaining implant designs, whereas 2 TKAs had constrained posterior stabilized implant designs. Patellar resurfacing was undergone in all knees. Bone graft required in 1 knee within severe knee deformity. Complication were occurred in 5 knees. Medial instability in 2 knees. Skin necrosis, MCL avulsion, recurrence of the