Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 315 - 315
1 Jul 2014
Dhooge Y Wentink N Theelen L van Hemert W Senden R
Full Access

Summary. The ankle X-ray has moderate diagnostic power to identify syndesmotic instability, showing large sensitivity ranges between observers. Classification systems and radiographic measurements showed moderate to high interobserver agreement, with extended classifications performing worse. Introduction. There is no consensus regarding the diagnosis and treatment of ankle fractures with respect to syndesmotic injury. The diagnosis of syndesmotic injury is currently based on intraoperative findings. Surgical indication is mainly made by ankle X-ray assessment, by several classification systems and radiographic measurements. Misdiagnosis of the injury results in suboptimal treatment, which may lead to chronic complaints, like instability and osteoarthritis. This study investigates the diagnostic power and interobserver agreement of three classification methods and radiographic measures, currently used to assess X-ankles and to identify syndesmotic injury. Patients and Methods. Twenty patients (43.2 ± 15.3yrs) with an ankle fracture, indicated for surgery, were prospectively included. All patients received a preoperative ankle X-ray, which was assessed by several observers: two orthopaedic surgeons, one trauma surgeon and two radiologists. The ankle X-ray was assessed on syndesmotic injury/stability and presence of fractures (fibula, medial/tertius malleolus). Three classification systems were used: Weber, AO-Müller (short-version n=3 options; extended-version n=27 options), Lauge-Hansen (short-version n=5 options; extended-version n=17 options) and two radiographic measurements were done: tibiofibular overlap (TFO) and ratio medial clearspace/superior clear space (MCS/SCS). All observers were instructed about the assessments before the measurements. During surgery, a proper intraoperative description of the syndesmosis was noted. Agreement (%), Intraclass Correlation Coefficients (ICC) and Kappa were calculated to determine interobserver agreement. Kappa statistic was interpreted according to Landis and Koch. To test the diagnostic power of ankle X-rays to identify syndesmotic instability, sensitivity and specificity were calculated with intraoperative findings serving as golden standard. Results. Six of 20 ankles showed syndesmotic instability intraoperatively. An overall sensitivity of 43% (specificity: 78) was found for X-rays in identifying syndesmotic instability, showing a wide range in sensitivity between observers (17–83%), with radiologists performing better (range 50–83%) than surgeons (range: 17–33%). Overall, substantial to perfect interobserver agreement (range 70–100%) was found for all short classification systems, showing an average kappa ≥0.60. The agreement reduced for more extended classification systems. E.g. observer agreement for the AO-Muller classification with 3, 9 and 27 options was respectively 85% (kappa 0.66), 68% (kappa 0.57) and 55% (kappa 0.51). One observer deviated slightly from others in all classification assessments. Removing this observer resulted in excellent agreement for all classification systems (>90%). Radiographic measurements showed moderate to high interobserver agreement, with TFO performing best (avg. ICC 0.88). Discussion/Conclusion. In ankle fractures, a preoperative X-ray has low sensitivity in detecting syndesmotic instability, showing large sensitivity ranges between observers. Further study is needed to investigate the contribution of classification systems in determining the best treatment method for syndesmotic injury. Ankle X-ray assessment using the three classification systems and radiographic measures was consistent among observers. Disagreement between observers can be attributed to intrinsic differences among the systems (e.g. stepwise classification vs. single assessment). No preference for one specific classification was found, as all showed comparable interobserver agreement. However classification systems with few options are recommended, as the observer agreement reduced with more extending classifications


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 50 - 50
11 Apr 2023
Souleiman F Zderic I Pastor T Gehweiler D Gueorguiev B Galie J Kent T Tomlinson M Schepers T Swords M
Full Access

The quest for optimal treatment of acute distal tibiofibular syndesmotic disruptions is still in progress. Using suture-button repair devices is one of the dynamic stabilization options, however, they may not be always appropriate for stabilization of length-unstable syndesmotic injuries. Recently, a novel screw-suture repair system was developed to address such issues. The aim of this study was to investigate the performance of the novel screw-suture repair system in comparison to a suture-button stabilization of unstable syndesmotic injuries. Eight pairs of human cadaveric lower legs were CT scanned under 700 N single-leg axial loading in five foot positions – neutral, 15° external/internal rotation and 20° dorsi-/plantarflexion – in 3 different states: (1) pre-injured (intact); (2) injured, characterized by complete syndesmosis and deltoid ligaments cuts simulating pronation-eversion injury types III and IV as well as supination-eversion injury type IV according to Lauge-Hansen; (3) reconstructed, using a screw-suture (FIBULINK, Group 1) or a suture-button (TightRope, Group 2) implants for syndesmotic stabilization, placed 20 mm proximal to the tibia plafond. Following, all specimens were: (1) biomechanically tested over 5000 cycles under combined 1400 N axial and ±15° torsional loading; (2) rescanned. Clear space (diastasis), anterior tibiofibular distance, talar dome angle and fibular shortening were measured radiologically from CT scans. Anteroposterior (AP), axial, mediolateral and torsional movements at the distal tibiofibular joint level were evaluated biomechanically via motion tracking. In each group clear space increased significantly after injury (p ≤ 0.004) and became significantly smaller in reconstructed compared with both pre-injured and injured states (p ≤ 0.041). In addition, after reconstruction it was significantly smaller in Group 1 compared to Group 2 (p < 0.001). AP and axial movements were significantly smaller in Group 1 compared with Group 2 (p < 0.001). No further significant differences were identified/detected between the groups (p ≥ 0.113). Although both implant systems demonstrate ability for stabilization of unstable syndesmotic injuries, the screw-suture reconstruction provides better anteroposterior translation and axial stability of the tibiofibular joint and maintains it over time under dynamic loading. Therefore, it could be considered as a valid option for treatment of syndesmotic disruptions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 22 - 22
4 Apr 2023
Souleiman F Zderic I Pastor T Gehweiler D Gueorguiev B Galie J Kent T Tomlinson M Schepers T Swords M
Full Access

The quest for optimal treatment of acute distal tibiofibular syndesmotic disruptions is still in full progress. Using suture-button repair devices is one of the dynamic stabilization options, however, they may not be always appropriate for stabilization of length-unstable syndesmotic injuries. Recently, a novel screw-suture repair system was developed to address such issues. The aim of this study was to investigate the performance of the novel screw-suture repair system in comparison to a suture-button stabilization of unstable syndesmotic injuries. Eight pairs of human cadaveric lower legs were CT scanned under 700 N single-leg axial loading in five foot positions – neutral, 15° external/internal rotation and 20° dorsi-/plantarflexion – in 3 different states: (1) pre-injured (intact); (2) injured, characterized by complete syndesmosis and deltoid ligaments cuts simulating pronation-eversion injury types III and IV, and supination-eversion injury type IV according to Lauge-Hansen; (3) reconstructed, using a screw-suture (FIBULINK, Group 1) or a suture-button (TightRope, Group 2) implants for syndesmotic stabilization, placed 20 mm proximal to the tibia plafond/joint surface. Following, all specimens were: (1) biomechanically tested over 5000 cycles under combined 1400 N axial and ±15° torsional loading; (2) rescanned. Clear space (diastasis), anterior tibiofibular distance, talar dome angle and fibular shortening were measured radiologically from CT scans. Anteroposterior, axial, mediolateral and torsional movements at the distal tibiofibular joint level were evaluated biomechanically via motion tracking. In each group clear space increased significantly after injury (p ≤ 0.004) and became significantly smaller in reconstructed compared with both pre-injured and injured states (p ≤ 0.041). In addition, after reconstruction it was significantly smaller in Group 1 compared to Group 2 (p < 0.001). Anteroposterior and axial movements were significantly smaller in Group 1 compared with Group 2 (p < 0.001). No further significant differences were detected between the groups (p ≥ 0.113). Conclusions. Although both implant systems demonstrate ability for stabilization of unstable syndesmotic injuries, the screw-suture reconstruction provides better anteroposterior translation and axial stability of the tibiofibular joint and maintains it over time under dynamic loading. Therefore, it could be considered as a valid option for treatment of syndesmotic disruptions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 5 - 5
2 Jan 2024
Huyghe M Peiffer M Cuigniez F Tampere T Ashkani-Esfahani S D'Hooghe P Audenaert E Burssens A
Full Access

One-fourth of all ankle trauma involve injury to the syndesmotic ankle complex, which may lead to syndesmotic instability and/or posttraumatic ankle osteoarthritis in the long term if left untreated. The diagnosis of these injuries still poses a deceitful challenge, as MRI scans lack physiologic weightbearing and plain weightbearing radiographs are subject to beam rotation and lack 3D information. Weightbearing cone-beam CT (WBCT) overcomes these challenges by imaging both ankles during bipedal stance, but ongoingdebate remains whether these should be taken under weightbearing conditions and/or during application of external rotation stress. The aim of this study is study therefore to compare both conditions in the assessment of syndesmotic ankle injuries using WBCT imaging combined with 3D measurement techniques. In this retrospective study, 21 patients with an acute ankle injury were analyzed using a WBCT. Patients with confirmed syndesmotic ligament injury on MRI were included, while fracture associated syndesmotic injuries were excluded. WBCT imaging was performed in weightbearing and combined weightbearing-external rotation. In the latter, the patient was asked to internally rotate the shin until pain (VAS>8/10) or a maximal range of motion was encountered. 3D models were developed from the CT slices, whereafter. The following 3D measurements were calculated using a custom-made Matlab® script; Anterior tibiofibular distance (AFTD), Alpha angle, posterior Tibiofibular distance (PFTD) and Talar rotation (TR) in comparison to the contralateral non-injured ankle. The difference in neutral-stressed Alpha angle and AFTD were significant between patients with a syndesmotic ankle lesion and contralateral control (P=0.046 and P=0.039, respectively). There was no significant difference in neutral-stressed PFTD and TR angle. Combined weightbearing-external rotation during CT scanning revealed an increased AFTD in patients with syndesmotic ligament injuries. Based on this study, application of external rotation during WBCT scans could enhance the diagnostic accuracy of subtle syndesmotic instability


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 43 - 43
1 Nov 2021
Peiffer M Arne B Sophie DM Thibault H Kris B Jan V Audenaert E
Full Access

Introduction and Objective. Forced external rotation is hypothesized as the key mechanism of syndesmotic ankle injuries. This complex trauma pattern ruptures the syndesmotic ligaments and induces a three-dimensional deviation from the normal distal tibiofibular joint configuration. However, current diagnostic imaging modalities are impeded by a two-dimensional assessment, without taking into account ligamentous stabilizers. Therefore, our aim is two-fold: (1) to construct an articulated statistical shape model of the normal ankle with inclusion of ligamentous morphometry and (2) to apply this model in the assessment of a clinical cohort of patients with syndesmotic ankle injuries. Materials and Methods. Three-dimensional models of the distal tibiofibular joint were analyzed in asymptomatic controls (N= 76; Mean age 63 +/− 19 years), patients with syndesmotic ankle injury (N = 13; Mean age 35 +/− 15 years), and their healthy contralateral equivalent (N = 13). Subsequently, the statistical shape model was generated after aligning all ankles based on the distal tibia. The position of the syndesmotic ligaments was predicted based on previously validated iterative shortest path calculation methodology. Evaluation of the model was described by means of accuracy, compactness and generalization. Canonical Correlation Analysis was performed to assess the influence of syndesmotic lesions on the distal tibiofibular joint congruency. Results. Our presented model contained an accuracy of 0.23 +/− 0.028 mm. Mean prediction accuracy of ligament insertions was 0.53 +/− 12 mm. A statistically significant difference in anterior syndesmotic distance was found between ankles with syndesmotic lesions and healthy controls (95% CI [0.32, 3.29], p = 0.017). There was a significant correlation between presence of syndesmotic injury and the morphological distal tibiofibular configuration (r = 0.873, p <0,001). Conclusions. In this study, we constructed a bony and ligamentous statistical model representing the distal tibiofibular joint Furthermore, the presented model was able to detect an elongation injury of the anterior inferior tibiofibular ligament after traumatic syndesmotic lesions in a clinical patient cohort


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 26 - 26
1 Apr 2018
Rustenburg C Blom R Stufkens S Kerkhoffs G Emanuel K
Full Access

Background. Ankle fractures are often associated with ligamentous injuries of the distal tibiofibular syndesmosis, the deltoid ligament and are predictive of ankle instability, early joint degeneration and long-term ankle dysfunction. Detection of ligamentous injuries and the need for treatment remain subject of ongoing debate. In the classic article of Boden it was made clear that injuries of the syndesmotic ligaments were of no importance in the absence of a deltoid ligament rupture. Even in the presence of a deltoid ligament rupture, the interosseous membrane withstood lateralization of the fibula in fractures up to 4.5mm above the ankle joint. Generally, syndesmotic ligamentous injuries are treated operatively by temporary fixation performed with positioning screws. But do syndesmotic injuries need to be treated operatively at all?. Methods. The purpose of this biomechanical cadaveric study was to investigate the relative movements of the tibia and fibula, under normal physiological conditions and after sequential sectioning of the syndesmotic ligaments. Ten fresh-frozen below-knee human cadaveric specimens were tested under normal physiological loading conditions. Axial loads of 50 Newton (N) and 700N were provided in an intact state and after sequential sectioning of the following ligaments: anterior-inferior tibiofibular (AITFL), posterior-inferior tibiofibular (PITFL), interosseous (IOL), and whole deltoid (DL). In each condition the specimens were tested in neutral position, 10 degrees of dorsiflexion, 30 degrees of plantar flexion, 10 degrees of inversion, 5 degrees of eversion, and externally rotated up to 10Nm torque. Finally, after sectioning of the deltoid ligament, we triangulated Boden's classic findings with modern instruments. We hypothesized that only after sectioning of the deltoid ligament; the lateralization of the talus will push the fibula away from the tibia. Results. During dorsiflexion and external rotation the ankle syndesmosis widened, and the fibula externally rotated after sequential sectioning of the syndesmotic ligaments. After the AITFL was sectioned the fibula starts rotating externally. However, the external rotation of the fibula significantly reduced when the external rotation torque was combined with axial loading up to 700N as compared to the external rotation torque alone. The most relative moments between the tibia and fibula were observed after the deltoid ligament was sectioned. Conclusion. Significant increases in movements of the fibula relative to the tibia occur when an external rotation torque is provided. However, axial pressure seemed to limit external rotation because of the bony congruence of the tibiotalar surface. The AITFL is necessary to prevent the fibula to rotate externally when the foot is rotating externally. The deltoid ligament is the main stabilizer of the ankle mortise