Advertisement for orthosearch.org.uk
Results 1 - 20 of 153
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 115 - 115
1 Nov 2018
Beaulé P
Full Access

Total hip arthroplasty (THA) is one of the most successful surgery. However, patients' expectations have increased over the last two decades in regards to hip function after joint replacement, the patients assume to return their daily and sport activities without major limitations. This presentation will examine the effect of surgical approaches and implant designs as well as rehabilitation protocol on the clinical and biomechanical outcomes after THA. The new implant designs for THA aim to improve joint function whereas the surgical approaches intend to reduce muscle damage to regain muscle strength. One important determinant measured from gait analysis is the hip abduction moment as the abductors play a key role in stabilizing the pelvis in the frontal plane, particularly in phases of transition, such as the single leg stance in walking or stair climbing. This showed that muscle strength needs to be preserved. To minimize the risk of hip joint instability, a strong focus of implant development has been carried out. To illustrate this important concept within the context of gait analysis, I will present two studies that examine the influence of surgical approach and biomechanical reconstruction; and the second, is a prospective RCT comparing a dual mobility implant to a standard total hip replacement


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 108 - 108
1 Dec 2020
Bayrak A Çelik M Duramaz A Başaran SH Kural C Kızılkaya C Kural A Şar M
Full Access

The aim of the study is to determine the histological, biochemical, and biomechanical efficacy of fibrin clot and vitamin C in the healing of Achilles tendon ruptures (ATR) in a rat model.52 adult Wistar Albino rats (300–450 g) were used in the study. 12 groups were divided into four groups as Monitor (Group I), Control (Group II), Fibrin Clot (Group III), Fibrin Clot with vitamin C (Group IV). Four rats were used to obtain fibrin clots. Fibroblast Growth Factor (FGF) and Vascular Endothelial Growth Factor (VEGF) were measured in the blood of tail vein (1 cc) on the 3rd, 7th, 14th, and 21st day. Four rats were sacrificed on the 21st day from each group for histological evaluation. The rest of the rats were sacrificed at 42nd day, half for biomechanical and a half for histological evaluation. The 42nd-day HSS scores in group III and group IV were significantly lower than those of group I and group II (p =0.036 and 0.019; respectively). The 42nd-day HSS score of group IV was significantly lower than group III (p =0.036). The Maximum force N value of group III and group IV was significantly higher than those of group I and group II (p <0.05). Group IV showed a significantly higher Maximum force N value than group III (p =0.025). The blood FGF and VEGF levels of group III and group IV on the 3rd, 7th, 14th, and 21st days were higher than those of group I and group II (p <0.05). In the experimentally formed ATR model, fibrin clot and vitamin C produced a stronger tendon structure in terms of biomechanics while providing histological and biochemically better quality tendon healing in the surgical treatment of ATR. We believe that this model can be used to accelerate high-quality tendon healing after ATR


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 120 - 120
2 Jan 2024
Camera A Biggi S Capuzzo A Cattaneo G Tedino R Bolognesi G
Full Access

Fractures of the prosthetic components after total knee arthroplasty (TKA) are rare but dangerous complications, sometimes difficult to diagnose and to manage. Aim of this study is to evaluate the incidence of component breakage and its treatment in our single institution's experience. We retrospectively review our institution registry. From 605 revision knee arthroplasties since 2000 to 2018, we found 8 cases of component breakage, of these 3 belonged to UKA, and 5 belonged to TKA. The UKA fractures were all on the metal tibial component; while 4 TKA fractures were ascribed to the liner (2 Posterior-Stabilized designs and 2 constrained designs) and only one case was on the femoral component. For every patient a revision procedure was performed, in two cases a tibial tubercle osteotomy was performed, while in one case (where the fracture was of the post cam) an arthroscopy was performed prior to the arthrotomy. All of the UKA fractures were treated with a standard revision implant. As regard the TKA, 2 liner fractures were treated with the only liner exchange, while the other 2 liner fractures and the fracture of the metallic component were treated with total knee revision. No intra- and post-operative complications were found. Component breakage after TKA is a serious complication. Its treatment, always surgical, can hide pitfalls, especially if the timing is not correct; indeed apart from the revision of one or more components, the surgeons must address any issues of management of bone defect and ligamentous stability.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 46 - 47
1 Oct 2022
Das A


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 9 - 9
1 Jan 2017
Pegg E Gill H MacLeod A
Full Access

Femoral head collapse is a possible complication after surgical treatment of femoral neck fractures. The purpose of this study was to examine whether implantation of a Sliding Hip Screw (SHS) or an X-Bolt could increase the risk of femoral head collapse. Similar to traditional hip screws, the X-Bolt is implanted through the femoral neck; however, it uses an expanding cross-shape to improve rotational stability. The risk of collapse was investigated alongside patient factors, such as osteonecrosis. This numerical study assessed the risk of femoral head collapse using linear eigenvalue buckling (an established method [1]), and also from the maximum von Mises stress within the cortical bone. The femoral head was loaded using the pressures reported by Yoshida et al. for a patient sitting down (reported to put the femoral head at greatest risk of collapse [2]), with a peak pressure of 9.4 MPa and an average pressure of 1.59 MPa. The femur was fixed in all degrees of freedom at a plane through the femoral neck. The X-Bolt and SHS were implanted in accordance with the operative techniques. The femoral head and implants were meshed with quadratic tetrahedral elements, and cortical bone was meshed with triangular thin shell elements. A converged mesh seeding density of 1.2 mm was used. All models were create and solved using ABAQUS finite element software (version 6.12, Simulia, Dassault Systèmes, France). The influence of implant type and presence was examined alongside a variety of patient factors:. Osteonecrosis, modelled as a cone of bone of varying angle, and varying modulus values. Cortical thinning. Reduced cortical modulus. Femoral head size. Twenty-two finite element models were run for each implant condition (intact; implanted with the X-Bolt; implanted with a SHS), resulting in a total of 66 models. The finite element models were validated using experimental tests performed on five 4. th. generation composite Sawbones femurs (Malmö, Sweden), and verified against previously published results [1]. No significant difference was found between the X-Bolt and the SHS, for either critical buckling pressure (p=0.964), or the maximum von Mises stress (p=0.274), indicating no difference in the risk of femoral head collapse. The maximum von Mises stress (and therefore the risk of collapse) within the cortical bone was significantly higher for the intact femoral head compared to both implants (X-Bolt: p=0.048, SHS: p=0.002). Of the factors examined, necrosis of the femoral head caused the greatest increase in risk. The study by Volokh et al. [1] concluded that deterioration of the cancellous bone underneath the cortical shell can greatly increase the risk of femoral head collapse, and the results of the present study support this finding. Interestingly the presence of either an X-Bolt or SHS implant appeared to reduce the risk of femoral head collapse


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 31 - 31
1 Jun 2012
Hussain S Cairns D Mann C Horey L Patil S Meek R
Full Access

The objective was to compare vastus lateralis muscle splitting verses muscle sparing surgical approach to proximal femur for fixation of intertrochanteric fracture. Of the 16 patients in this prospective randomised double blind study 8 were randomised to vastus lateralis muscle splitting and rest to muscle sparing group. Main outcome measurement was assessment of status of vastus lateralis muscle at 2 and 6 weeks using nerve conduction study. Preoperative demographics were identical for both the groups. There was no statistically significant difference between the groups with regards to velocity, latency, and amplitude. The postoperative haemoglobin drop, heamatocrit, position of the dynamic hip screw and mobility status were identical. Both clinical and neurophysiological outcome suggest that damage done to vastus lateralis either by splitting or elevating appears to be identical


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 25 - 25
1 Apr 2018
de Bot R Stevens J Hermus J Staal H van Rhijn L Witlox A
Full Access

Purpose

Flat feet are an important cause of foot problems in children. The flexible flat foot is the most common form and is normally physiological and asymptomatic. Further assessment is necessary when a symptomatic flat foot persists. Surgical interventions are indicated when conservative therapies have failed. The Kalix arthroereisis is a surgical option and is placed in the subtalar joint of the foot, thereby preventing hyperpronation, and stabilizes the foot against excessive movements. The purpose of this study was to evaluate the functional and radiological outcomes of pediatric patients who had undergone a Kalix implantation for the treatment of a symptomatic flexible flat foot.

Methods

Patient files of our institution were searched for patients who underwent a Kalix implantation between 2009 and 2014. Sixteen patients (26 feet) with symptomatic flexible flat feet were clinically and radiographically evaluated in this retrospective study. The calcaneal pitch and Meary”s angle were measured on the pre-, and postoperative follow-up radiographs and patient satisfaction survey was performed at follow-up to gain insight into functional outcome and satisfaction after the intervention.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 140 - 140
11 Apr 2023
Gens L Marchionatti E Steiner A Stoddart M Thompson K Mys K Zeiter S Constant C
Full Access

Autologous cancellous bone graft is the gold standard in large bone defect repair. However, studies using autologous bone grafting in rats are rare and donor sites as well as harvesting techniques vary. The aim of this study was to determine the feasibility of autologous cancellous bone graft harvest from 5 different anatomical sites in rats and compare their suitability as donor sites for autologous bone graft. 13 freshly euthanised rats were used to describe the surgical approaches for autologous bone graft harvest from the humerus, iliac crest, femur, tibia and tail vertebrae (n=4), determine the cancellous bone volume and microstructure of those five donor sites using µCT (n=5), and compare their cancellous bone collected qualitatively by looking at cell outgrowth and osteogenic differentiation using an ALP assay and Alizarin Red S staining (n=4). It was feasible to harvest cancellous bone graft from all 5 anatomical sites with the humerus and tail being more surgically challenging. The microstructural analysis showed a significantly lower bone volume fraction, bone mineral density, and trabecular thickness of the humerus and iliac crest compared to the femur, tibia, and tail vertebrae. The harvested volume did not differ between the donor sites. All donor sites apart from the femur yielded primary osteogenic cells confirmed by the presence of ALP and Alizarin Red S stain. Bone samples from the iliac crest showed the most consistent outgrowth of osteoprogenitor cells. The tibia and iliac crest may be the most favourable donor sites considering the surgical approach. However, due to the differences in microstructure of the cancellous bone and the consistency of outgrowth of osteoprogenitor cells, the donor sites may have different healing properties, that need further investigation in an in vivo study


Introduction. This study aims to investigate the relationship between ulnar fixation and postoperative satisfaction among patients with distal radius fractures accompanied by ulna styloid fractures, with a particular focus on how sociodemographic factors influence outcomes. Method. A retrospective cohort study was conducted involving 120 patients aged 26-53 who underwent surgical treatment for distal radius fractures with concomitant ulna styloid fractures between January 2018 and December 2022. Patients were divided into two groups based on whether ulnar fixation was performed. Sociodemographic data, including age, gender, socioeconomic status, education level, and occupation, were collected. All patients underwent similar physical therapy protocols in the postoperative period, and no complications were observed in any patient. Postoperative satisfaction was assessed using the Patient-Rated Wrist Evaluation (PRWE) and the Disabilities of the Arm, Shoulder, and Hand (DASH) scores at 6 and 12 months post-surgery. Statistical analysis was conducted to evaluate the influence of ulnar fixation and sociodemographic factors on patient satisfaction. Result. Patients who underwent ulnar fixation (n=60) reported significantly higher satisfaction levels compared to those who did not (n=60), as evidenced by lower PRWE and DASH scores (p < 0.05). Age, gender, and socioeconomic status were significant predictors of postoperative satisfaction. Younger patients, females, and those with higher socioeconomic status exhibited greater improvements in functional outcomes and satisfaction. However, education level and occupation did not significantly influence satisfaction scores. Conclusion. Ulnar fixation in the surgical treatment of distal radius fractures accompanied by ulna styloid fractures is associated with improved postoperative satisfaction. Sociodemographic factors, particularly age, gender, and socioeconomic status, play a crucial role in patient-reported outcomes. Tailoring postoperative care to address these sociodemographic differences may enhance overall patient satisfaction and recovery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 143 - 143
4 Apr 2023
Kröger I Pätzold R Brand A Wackerle H Klöpfer-Krämer I Augat P
Full Access

Tibial shaft fractures require surgical stabilization preferably by intramedullary nailing. However, patients often report functional limitations even years after the injury. This study investigates the influence of the surgical approach (transpatellar vs. parapatellar) on gait performance and patient reported outcome six months after surgery. Twenty-two patients with tibial shaft fractures treated by intramedullary nailing through a transpatellar approach (TP: n=15, age 41±15, BMI 24±3) or a parapatellar approach (PP: n=7, age 34±15, BMI 23±2) and healthy, matched controls (n=22, age 39±13, BMI 24±2) were assessed by instrumented motion analysis six months after intramedullary nailing. Short musculoskeletal function assessment questionnaire (SMFA) as well as kinematic and kinetic gait data were collected during level walking. Comparisons among approach methods and control group were performed by analysis of variance and Mann-Whitney test. Six months after surgery, knee kinetics in both groups differed significantly compared to controls (p <.04). The approach method affected gait speed (TP: p = .002; PP: p = .08) and knee kinematics in the early stance phase (TP: p = .011; PP: p = .082), with the parapatellar approach showing a more favorable outcome. However, the difference between patient groups was not significant for any of the assessed gait parameters (p > .2). Also, no differences could be found in the bother index (BI) or function index (FI) of SMFA between surgical approach methods (BI: TP: Mdn = 7.2, PP: Mdn = 9.4; FI: TP: Mdn = 10.3, PP: Mdn = 9.2, p > .7). Our study demonstrates, that six months after surgery for tibial shaft fractures functional limitations remain. These limitations appear not to be different for either a trans- or a parapatellar approach for the insertion of the intramedullary nail. The findings of this study are limited by the relatively short follow up time period and small number of patients. Future studies should investigate the source of the functional limitation after intramedullary nailing of tibial shaft fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 21 - 21
17 Apr 2023
Zioupos S Westacott D
Full Access

Flat-top talus (FTT) is a complication well-known to those treating clubfoot. Despite varying anecdotal opinions, its association with different treatments, especially the Ponseti method, remains uncertain. This systematic review aimed to establish the aetiology and prevalence of FTT, as well as detailing management strategies and their efficacy. A systematic review was conducted according to PRISMA guidelines to search for articles using MEDLINE, EMBASE and Web of Science until November 2021. Studies with original data relevant to one of three questions were included: 1) Possible aetiology 2) Prevalence following different treatments 3) Management strategies and their outcomes. 32 original studies were included, with a total of 1473 clubfeet. FTT may be a pre-existing feature of the pathoanatomy of some clubfeet as well as a sequela of treatment. It can be a radiological artefact due to positioning or other residual deformity. The Ponseti method is associated with a higher percentage of radiologically normal tali (57%) than both surgical methods (52%) and non-Ponseti casting (29%). Only one study was identified that reported outcomes after surgical treatment for FTT (anterior distal tibial hemiepiphysiodesis). The cause of FTT remains unclear. It is seen after all treatment methods but the rate is lowest following Ponseti casting. Guided growth may be an effective treatment. Key words:. Clubfoot, Flat-top talus, Ponseti method, guided growth. Disclosures: The authors have no relevant disclosures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 7 - 7
4 Apr 2023
Bottomley J Al-Dadah O
Full Access

Meniscal tears are the most common injury in the knee, affecting 66/100,000 people/year. Surgical treatment includes arthroscopic meniscectomy or meniscal repair. Little is known regarding medium-term outcomes following these procedures in isolated meniscal tears. This study aims to quantitatively evaluate patients with meniscal tears, and those who have undergone meniscectomy and meniscal repair using validated patient reported outcome measures (PROMs), further exploring factors which affect surgical outcomes. This observational study screened 334 patients who underwent arthroscopic surgery at South Tyneside Hospital since August 2013. 134 patients with isolated meniscal tears were invited to complete postal PROMs. A combination of patient notes and radiological imaging was used to collect information of interest including age, gender, knee-laterality, injured meniscus, tear pattern, procedure performed, complications, and associated injuries. A total of 115 patients (pre-operative patients with current meniscal tear (n=36), meniscectomy (n=63), meniscal repair (n=16)) were included in the analysis with 96% successful PROM completion. Both meniscectomy and meniscal repairs (mean 55-months follow-up) showed better outcomes than pre-operative patients with meniscal tears. Meniscal repairs demonstrated superior outcomes across all PROMs when compared to meniscectomy, with a greater mean overall KOOS score of 17.2 (p=0.009). Factors including higher pre-operative Kellgren-Lawrence Grade, pre-operative articular cartilage lesions and bilateral meniscectomies were shown to negatively influence outcomes. Both meniscectomy and meniscal repair maintain clinical benefit at mean 55-months follow-up, affirming their use for treatment of meniscal tears. When feasible, meniscal repair should be performed preferentially over meniscectomy in isolated meniscal tears. Identified predictive factors allow adequate treatment stratification in specific patient groups


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 69 - 69
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Bispo C
Full Access

Radial head fractures are among the most common fractures around the elbow. Radial head arthroplasty is one of the surgical treatment options after complex radial head fractures. This surgery is usually done under general anaesthesia. However, there is a recent anaesthetic technique - wide awake local anaesthesia no tourniquet (WALANT) - that has proven useful in different surgical settings, such as in distal radius or olecranon fractures. It allows a good haemostatic control without the use of a tourniquet and allows the patient to actively collaborate during the surgical procedure. Furthermore, there are no side effects or complications caused by the general anaesthesia and there's an earlier patient discharge. The authors present the case of a seventy-six-year-old woman who presented to the emergency department after a fall from standing height with direct trauma to the left elbow. The radiological examination revealed a complete intra-articular comminuted fracture of the radial head (Mason III). Clinical management: The patient was submitted to surgery with radial head arthroplasty, using WALANT. The surgery was successfully completed without pain. There were no intra or immediate post-operative complications and the patient was discharged on the same day. Six weeks after surgery, the patient had almost full range of motion and was very pleased with the functional outcome, with no limitations on her activities of daily living. The use of WALANT has been expanded beyond the hand and wrist surgery. It is a safe and simple option for patients at high risk of general anaesthesia, allowing similar surgical outcomes without the intraoperative and postoperative complications of general anaesthesia and permitting an earlier hospital discharge. Furthermore, it allows the patient to actively collaborate during the surgery, providing the surgeons the opportunity to evaluate active mobility and stability, permitting final corrections before closing the incision


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 40 - 40
17 Apr 2023
Saiz A Kong S Bautista B Kelley J Haffner M Lee M
Full Access

With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test. 209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05). PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal comminution, and be isolated; whereas, NDFF tend to occur in younger patients, have less metaphyseal comminution, and be associated with other fractures. When controlling for variables, PDFF are at increased risk of unplanned revision reoperation. Surgeons should be aware of these increased risks in PDFFs and future research should focus on these unique fracture characteristics to improve outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 60 - 60
4 Apr 2023
MacLeod A Mandalia V Mathews J Toms A Gill H
Full Access

High tibial osteotomy (HTO) is an effective surgical treatment for isolated medial compartment knee osteoarthritis; however, widespread adoption is limited due to difficulty in achieving the planned correction, and patient dissatisfaction due to soft tissue irritation. A new HTO system – Tailored Osteotomy Knee Alignment (TOKA®, 3D Metal Printing Ltd, Bath, UK) could potentially address these barriers having a custom titanium plate and titanium surgical guides featuring a unique mechanism for precise osteotomy opening as well as saw cutting and drilling guides. The aim of this study was to assess the accuracy of this novel HTO system using cadaveric specimens; a preclinical testing stage ahead of first-in-human surgery according to the ‘IDEAL-D’ framework for device innovation. Local ethics committee approval was obtained. The novel opening wedge HTO procedure was performed on eight cadaver leg specimens. Whole lower limb CT scans pre- and post-operatively provided geometrical assessment quantifying the discrepancy between pre-planned and post-operative measurements for key variables: the gap opening angle and the patient specific surgical instrumentation positioning and rotation - assessed using the implanted plate. The average discrepancy between the pre-operative plan and the post-operative osteotomy correction angle was: 0.0 ± 0.2°. The R2 value for the regression correlation was 0.95. The average error in implant positioning was −0.4 ± 4.3 mm, −2.6 ± 3.4 mm and 3.1 ± 1.7° vertically, horizontally, and rotationally respectively. This novel HTO surgery has greater accuracy and smaller variability in correction angle achieved compared to that reported for conventional or other patient specific methods with published data available. This system could potentially improve the accuracy and reliability of osteotomy correction angles achieved surgically


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 99 - 99
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

The covid-19 pandemic had a great impact in the daily clinical and surgical practice. Concerning patients with a femoral neck fracture, there is the need of a negative Sars-CoV-2 test or an established isolation period for the positive cases, pre-operatively. The goal of this study was to evaluate the impact of the pandemic in the management of patients with femoral neck fractures, who were submitted to surgical treatment with hemiarthroplasty, in our hospital. A retrospective, observational study was performed, analysing the patients with femoral neck fractures submitted to hip hemiarthroplasty, during the years 2019 (before the pandemic) and 2020 (first year of the pandemic). We analysed the first 5 patients operated in each month of the mentioned years. We analysed 56 and 60 patients submitted to surgery in the years 2019 and 2020, respectively. The inpatient days were, in average, 14.1 and 13.1. Patients were operated, in average, 3.0 and 3.8 days after admission (corrected to 2.5 and 3.6 days if the time of discontinuation of anticoagulants or antiplatelets needed before surgery is deducted). There were peri-operative complications in 53.6% and 46.7% of the patients, in 2019 and 2020 respectively. The most common complication in both groups was a low postoperative haemoglobin level needing red blood cell transfusion. One-year postoperative mortality rate was 17.9% and 13.3%, respectively. Despite the changes triggered by the new pandemic, there was an overall maintenance of the quality of the management of these patients, with only a slight increase in the interval between admission and surgery. Some of the remaining variables even showed an improvement when comparing the two groups of patients. Nevertheless, it is important to mention that there were patients infected with Covid-19 who died before being submitted to surgery, therefore not being present in these statistics


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 95 - 95
4 Apr 2023
Troiano E Giacomo P Di Meglio M Nuvoli N Mondanelli N Giannotti S Orlandi N
Full Access

Infections represent a devastating complication in orthopedic and traumatological surgery, with high rates of morbidity and mortality. An early intervention is essential, and it includes a radical surgical approach supported by targeted intravenous antimicrobial therapy. The availability of parenteral antibiotics at the site of infection is usually poor, so it is crucial to maximize local antibiotic concentration using local carriers. Our work aims to describe the uses of one of these systems, Stimulan®, for the management and prevention of infections at our Institution. Analysing the reported uses of Stimulan®, we identified two major groups: bone substitute and carrier material for local antibiotic therapy. The first group includes its application as a filler of dead spaces within bone or soft tissues resulting from traumatic events or previous surgery. The second group comprehends the use of Stimulan® for the treatment of osteomyelitis, post-traumatic septic events, periprosthetic joint infections, arthroplasty revision surgery, prevention in open fractures, surgery of the diabetic foot, oncological surgery and for all those patients susceptible to a high risk of infection. We used Stimulan® in several complex clinical situations: in PJIs, in DAPRI procedure and both during the first and the second stage of a 2-stage revision surgery; furthermore, we started to exploit this antibiotic carrier also in prophylaxis of surgical site infections, as it happens in open fractures, and when a surgical site remediation is required, like in osteomyelitis following ORIF. Stimulan® is an extremely versatile and polyhedric material, available in the form of beads or paste, and can be mixed to a very broad range of antibiotics to better adapt to different bacteria and their antibiograms, and to surgeon's needs. These properties make it a very useful adjuvant for the management of complex cases of infection, and for their prevention, as well


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 72 - 72
17 Apr 2023
Hsieh Y Hsieh M Shu Y Lee H
Full Access

A spine compression fracture is a very common form of fracture in elderly with osteoporosis. Injection of polymethyl methacrylate (PMMA) to fracture sites is a minimally invasive surgical treatment, but PMMA has considerable clinical risks. We develop a novel type thermoplastic injectable bone substitute contains the proprietary composites of synthetic ceramic bone substitute and absorbable thermoplastic polymer. We used thermoplastic biocompatible polymers Polycaproactone (PCL) to encapsulate calcium-based bone substitutes hydroxyapatite (Ca10(PO4)6(OH)2, HA) and tricalcium phosphate (TCP) to form a biodegradable injectable bone composite material. The space occupation ration PCL:HA/TCP is 1:9. After heating process, it can be injected to fracture site by specific instrument and then self-setting to immediate reinforce the vertebral body. The thermoplastic injection bone substitute can obtain good injection properties after being heated by a heater at 90˚C for three minutes, and has good anti-washout property when injected into normal saline at 37˚C. After three minutes, solidification is achieved. Mechanical properties were assessed using the material compression test system and the mechanical support close to the vertebral spongy bone. In vitro cytotoxicity MTT assay (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) was performed and no cell cytotoxicity was observed. In vivo study with three New Zealand rabbits was performed, well bone growth into bone substitute was observed and can maintain good mechanical support after three months implantation. The novel type thermoplastic injection bone substitute can achieve (a) adequate injectability and viscosity without the risk of cement leakage; (b) adequate mechanical strength for immediate reinforcement and prevent adjacent fracture; (c) adequate porosity for new bone ingrowth; (e) biodegradability. It could be developed as a new option for treating vertebral compression fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 6 - 6
2 Jan 2024
Orellana F Grassi A Wahl P Nuss K Neels A Zaffagnini S Parrilli A
Full Access

A comprehensive understanding of the self-repair abilities of menisci and their overall function in the knee joint requires three-dimensional information. However, previous investigations of the meniscal blood supply have been limited to two-dimensional imaging methods, which fail to accurately capture tissue complexity. In this study, micro-CT was used to analyse the 3D microvascular structure of the meniscus, providing a detailed visualization and precise quantification of the vascular network. A contrast agent (μAngiofil®) was injected directly into the femoral artery of cadaver legs to provide the proper contrast enhancement. First, the entire knee joint was analysed with micro-CT, then to increase the applicable resolution the lateral and medial menisci were excised and investigated with a maximum resolution of up to 4 μm. The resulting micro-CT datasets were analysed both qualitatively and quantitatively. Key parameters of the vascular network, such as vascular volume fraction, vessel radius, vessel length density, and tortuosity, were separately determined for the lateral and medial meniscus, and their four circumferential zones defined by Cooper. In accordance with previous literature, the quantitative micro-CT data confirm a decrease in vascular volume fraction along the meniscal zones. The highest concentration of blood vessels was measured in the meniscocapsular region 0, which is characterized by vascular segments with a significantly larger average radius. Furthermore, the highest vessel length density observed in zone 0 suggests a more rapid delivery of oxygen and nutrients compared to other regions. Vascular tortuosity was detected in all circumferential regions, indicating the occurrence of vascular remodelling in all tissue areas. In conclusion, micro-CT is a non-invasive imaging technique that allows for the visualization of the internal structure of an object in three dimensions. These advanced 3D vascular analyses have the potential to establish new surgical approaches that rely on the healing potential of specific areas of the meniscus. Acknowledgements: The authors acknowledge R. Hlushchuk, S. Halm, and O. Khoma from the University of Bern for their help with contrast agent perfusions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 28 - 28
11 Apr 2023
Wither C Lawton J Clarke D Holmes E Gale L
Full Access

Range of Motion (ROM) assessments are routinely used during joint replacement to evaluate joint stability before, during and after surgery to ensure the effective restoration of patient biomechanics. This study aimed to quantify axial torque in the femur during ROM assessment in total hip arthroplasty to define performance criteria against which hip instruments can be verified. Longer term, this information may provide the ability to quantitatively assess joint stability, extending to quantitation of bone preparation and quality. Joint loads measured with strain-gaged instruments in five cadaveric femurs prepared using posterior approach were analysed. Variables such as surgeon-evaluator, trial offset and specimen leg and weight were used to define 13 individual setups and paired with surgeon appraisal of joint tension for each setup. Peak torque loads were then identified for specific motions within the ROM assessment. The largest torque measured in most setups was observed during maximum extension and external rotation of the joint, with a peak torque of 13Nm recorded in a specimen weighing 98kg. The largest torque range (19.4Nm) was also recorded in this specimen. Other motions within the trial reduction showed clear peaks in applied torque but with lower magnitude. Relationships between peak torque, torque range and specimen weight produced an R2 value greater than 0.65. The data indicated that key influencers of torsional loads during ROM were patient weight, joint tension and limb motion. This correlation with patient weight should be further investigated and highlights the need for population representation during cadaveric evaluation. Although this study considered a small sample size, consistent patterns were seen across several users and specimens. Follow-up studies should aim to increase the number of surgeon-evaluators and further vary specimen size and weight. Consideration should also be given to alternative surgical approaches such as the Direct Anterior Approach