Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 421 - 421
1 Sep 2012
Young L Kent M Rehmatullah N Chojnowski A
Full Access

Purpose. To analyse the early results of unconstrained pyrocarbon joint replacements in patients with osteo-arthritis of the metacarpo-phalangeal joints. Background. Silicone arthroplasty, as introduced by Swanson in 1962 has remained the most popular procedure to treat arthritis of the metacarpo-phalangeal (MCP) joints. However, despite providing good pain relief, they have shown to demonstrate breakage rates up to 82% at 5 years. This is of great concern in the osteoarthritis (OA) patient group, who tend to be younger and have higher functional demands compared to their rheumatoid counterparts. The newer unconstrained pyrolytic carbon MCP joint prostheses may therefore be more suitable in OA patients whose soft tissue constraints are intact and whose hand function is strong. This study is the first to analyse the results of this implant in a cohort of OA patients only, with prospective data. Methods. 19 primary pyrocarbon metacarpo-phalangeal joint replacements, in 11 patients (5 men and 6 women) were reviewed, with prospective data collection. The diagnosis was primary osteoarthritis in all patients. The mean age at operation was 66.4 years (range 55–82 years). 2 patients underwent concomitant trapiezectomy and one underwent DIPJ fusion. All patients were right hand dominant −75% underwent surgery in their dominant hand. Eleven of the nineteen joints were performed in the index finger, with the remainder in the middle finger. Mean follow up is 22.1 months (range 11–37). Results. At the 3 month post-operative hand therapy assessment, the arc of motion had improved from a mean of 32 degrees to 45 degrees and flexion had improved from a mean of 51 degrees to 66 degrees. Grip strength improved from a mean 20 to 27Kg. DASH scores significantly improved from a mean of 40 to 10 (p=0.01). All patients were satisfied with their outcomes and would have the surgery again. Pre-operative radiographs demonstrated joint narrowing in all patients but no evidence of heterotopic ossification, cystic change or erosions. Post-operatively, there has been no radiographic evidence of joint dislocation, resorption stress-shielding, loosening, migration or heterotopic ossification. There were three intra-operative complications of phalangeal fractures that were immediately treated with a cerclage wire. In one patient there has been a fracture of the proximal phalangeal implant at 14 months which was asymptomatic. One patient has required revision for mal-rotation of the implant leading to loss of index finger supination. Conclusion. Our results demonstrate excellent early results of pyrocarbon MCP joint arthroplasty in OA patients


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246).

We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions.

Cite this article: Bone Joint J 2014;96-B:548–54.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 825 - 830
1 Jun 2013
Abram SGF Pollard TCB Andrade AJMD

The Gamma nail is frequently used in unstable peri-trochanteric hip fractures. We hypothesised that mechanical failure of the Gamma nail was associated with inadequate proximal three-point fixation. We identified a consecutive series of 299 Gamma nails implanted in 299 patients over a five-year period, 223 of whom fulfilled our inclusion criteria for investigation. The series included 61 men and 162 women with a mean age of 81 years (20 to 101). Their fractures were classified according to the Modified Evans’ classification and the quality of fracture reduction was graded. The technical adequacy of three points of proximal fixation was recorded from intra-operative fluoroscopic images, and technical inadequacy for each point was defined. All patients were followed to final follow-up and mechanical failures were identified. A multivariate statistical analysis was performed, adjusting for confounders. A total of 16 failures (7.2%) were identified. The position of the lag screw relative to the lateral cortex was the most important point of proximal fixation, and when inadequate the failure rate was 25.8% (eight of 31: odds ratio 7.5 (95% confidence interval 2.5 to 22.7), p < 0.001).

Mechanical failure of the Gamma nail in peri-trochanteric femoral fractures is rare (< 1%) when three-point proximal fixation is achieved. However, when proximal fixation is inadequate, failure rates increase. The strongest predictor of failure is positioning the lateral end of the lag screw short of the lateral cortex. Adherence to simple technical points minimises the risk of fixation failure in this vulnerable patient group.

Cite this article: Bone Joint J 2013;95-B:825–30.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.