Advertisement for orthosearch.org.uk
Results 1 - 20 of 254
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1331 - 1340
3 Oct 2020
Attard V Li CY Self A Mann DA Borthwick LA O’Connor P Deehan DJ Kalson NS

Aims. Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. Methods. Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosis. 1. (n = 8) underwent an MRI scan with advanced metal suppression (Slice Encoding for Metal Artefact Correction, SEMAC) with gadolinium contrast. Fibrotic tissue (low intensity on T1 and T2, low-moderate post-contrast enhancement) was quantified (presence and tissue thickness) in six compartments: supra/infrapatella, medial/lateral gutters, and posterior medial/lateral. Results. Fibrotic tissue was identified in all patients studied. However, tissue was significantly thicker in fibrotic patients (4.4 mm ± 0.2 mm) versus non-fibrotic (2.5 mm ± 0.4 mm) and normal TKAs (1.9 mm ± 0.2 mm, p = < 0.05). Significant (> 4 mm thick) tissue was seen in 26/48 (54%) of compartments examined in the fibrotic group, compared with 17/30 (57%) non-fibrotic, and 10/66 (15%) normal TKAs. Although revision surgery did improve range of movement (ROM) in all fibrotic patients, clinically significant restriction remained post-surgery. Conclusion. Stiff TKAs contain intra-articular fibrotic tissue that is identifiable by MRI. Studies should evaluate whether MRI is useful for surgical planning of debridement, and as a non-invasive measurement tool following interventions for stiffness caused by fibrosis. Revision for stiffness can improve ROM, but outcomes are sub-optimal and new treatments are required. Cite this article: Bone Joint J 2020;102-B(10):1331–1340


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims. To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps. Methods. In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used. Results. Overall mean ROM in stiff knees increased preoperatively from 67° (0° to 80°) to 114° postoperatively (65° to 135°) (p < 0.001). Mean knee flexion improved from 82° (0° to 110°) to 115° (65° to 135°) and mean flexion contracture decreased from 14° (0° to 50°) to 1° (0° to 10°) (p < 0.001). The mean Knee Society Score (KSS) improved from 34 (0 to 71) to 88 (38 to 100) (p < 0.001) and the KSS Functional Score from 43 (0 to 70) to 86 (0 to 100). Seven knees (7%) required manipulations under anaesthesia (MUA) and none of the knees had flexion instability. The mean overall ROM in the control group improved from 117° (100° to 140°) to 123° (100° to 130°) (p < 0.001). Mean knee flexion improved from 119° (100° to 140°) to 123° (100° to 130°) (p < 0.001) and mean flexion contracture decreased from 2° (0° to 15°) to 0° (0° to 5°) (p < 0.001). None of the knees in the control group had flexion instability or required MUA. The mean KSS Knee Score improved from 48 (0 to 80) to 94 (79 to 100) (p < 0.001) and the KSS Functional Score from 52 (5 to 100) to 95 (60 to 100) (p < 0.001). Mean improvement in ROM (p < 0.001) and KSS Knee Score (p = 0.017) were greater in knees with preoperative stiffness compared with the control group, but the KSS Functional Score improvement was comparable (p = 0.885). Conclusion. TKA with a 2 mm increased flexion gap provided a significant improvement of ROM in knees with preoperative stiffness. While the improvement in ROM was greater, the absolute postoperative ROM was less than in matched non-stiff knees. PS TKA with patellar resurfacing and a 2 mm increased flexion gap, in combination with adequate soft tissue balancing, provides excellent ROM and knee function when stiffness of the knee had been present preoperatively. Cite this article: Bone Joint J 2020;102-B(4):426–433


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 622 - 627
1 May 2016
Donaldson JR Tudor F Gollish J

Aims. The aim of this study was to examine the results of revision total knee arthroplasty (TKA) undertaken for stiffness in the absence of sepsis or loosening. Patients and Methods. We present the results of revision surgery for stiff TKA in 48 cases (35 (72.9%) women and 13 (27.1%) men). The mean age at revision surgery was 65.5 years (42 to 83). All surgeries were performed by a single surgeon. Stiffness was defined as an arc of flexion of < 70° or a flexion contracture of > 15°. The changes in the range of movement (ROM) and the Western Ontario and McMasters Osteoarthritis index scores (WOMAC) were recorded. Results. At a mean follow up of 59.9 months (12 to 272) there was a mean improvement in arc of movement of 45.0°. Mean flexion improved from 54.4° (5° to 100°) to 90° (10° to 125°) (p <  0.05) and the mean flexion contracture decreased from 12.0° (0° to 45°) to 3.5° (0° to 25°) (p < 0.05). The mean WOMAC scores improved for pain, stiffness and function. In patients with extreme stiffness we describe a novel technique, which we have called the ‘sloppy’ revision. This entails downsizing the polyethylene insert by 4 mm and using a more constrained liner to retain stability. Conclusion. To our knowledge, this is the largest series of revision surgeries for stiffness reported in the literature where infection and loosening have been excluded. . Take home message: Whilst revision surgery is technically demanding, improvements in ROM and outcome can be achieved, particularly when the revision is within two years of the primary surgery. Cite this article: Bone Joint J 2016;98-B:622–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 103 - 111
1 Nov 2012
Vince KG

Seven stiff total knee arthroplasties are presented to illustrate the roles of: 1) manipulation under general anesthesia; 2) multiple concurrent diagnoses in addition to stiffness; 3) extra-articular pathology; 4) pain as part of the stiffness triad (pain and limits to flexion or extension); 5) component internal rotation; 6) multifactorial etiology; and 7) surgical exposure in this challenging clinical problem


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 12 - 12
1 Oct 2020
Wooster BM Abdel MP Berry DJ Pagnano MW
Full Access

Introduction. Arthrofibrosis remains a persistent complication following total knee arthroplasty (TKA). Although manipulation under anesthesia (MUA) is an effective early treatment, the risks and value of this procedure beyond 3 months after TKA remain controversial. The purpose of this study was to examine the safety and efficacy of late MUAs for arthrofibrosis. Methods. From our institutional total joint registry, 82 TKAs (77 patients) who underwent MUA >3 months after primary (83%) or revision (17%) TKA were identified. Mean time to MUA was 7 months: 66% performed between 4–6 months, 18% between 7–12 months, 16% beyond 12 months. MUAs were coupled with arthroscopic assistance in 26% (12% limited lysis of adhesions, 13% formal arthroscopic debridement). Mean age was 61 years, 59% females, and mean BMI was 33kg/m. 2. Mean follow-up was 5 years. Results. No fractures, extensor mechanism disruptions, or other complications related to late MUA occurred. The mean ROM gained after MUA was 18° (76° to 94°, p<0.001). Substantial ROM gains (≥20°) occurred in 50%, while 21% made no gains or lost ROM after MUA. ROM gains ≥20° occurred in 54% of primary TKAs and 28% of revision TKAs. While ROM gains were higher when performed between 3–6 months (21°) compared to 6–12 months (13°) and >12 months (11°), these differences did not reach statistical significance (p=0.26). No differences in mean ROM gains were observed in MUAs performed with or without arthroscopic assistance (19° versus 15°, p=0.54). Kaplan Meier survivorship free of repeat MUA and revision TKA were 85% and 80% at 20 years, respectively. Conclusion. Late MUA, coupled with arthroscopic assistance in selected patients, was safe in a broad range of stiff primary and revision TKAs with no fractures or extensor disruptions occurring. While mean ROM improvements were modest, a substantial subset of patients achieved clinically important ROM gains ≥20°. Summary. Late MUA substantially improved ROM in a subset of patients with stiff TKAs and was done safely. In selected patients, arthroscopic lysis of adhesions or formal debridement aided the perceived safety and efficacy


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1357 - 1360
1 Oct 2005
Hutchinson JRM Parish EN Cross MJ

Stiffness is an uncommon but potentially debilitating complication following total knee replacement (TKR). The treatment of this condition remains difficult and controversial. We present the results of 13 patients who underwent open arthrolysis for stiffness. The mean time between TKR and arthrolysis was 14 months. The mean follow-up was 7.2 years (2 to 10). The mean range of movement prior to arthrolysis was 55°. This increased to 91°, six months after arthrolysis (p < 0.005). The improved range of movement was maintained during the follow-up period. No patient has required revision of their components. We have found arthrolysis to be a useful and successful approach to post-TKR stiffness


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 217 - 221
1 Feb 2010
Hahn SB Choi YR Kang HJ Lee SH

Between 1987 and 2006 we performed a modified Thompson’s quadricepsplasty on 40 fracture-related stiff knees and followed the patients for a mean of 7.9 years (2 to 11.1). The factors affecting the final gain of movement were investigated. A total of 15 knees required lengthening of the rectus femoris. The mean flexion gain was 70.2° (42.3° to 112.5°). According to Judet’s criteria, the results were excellent in 30 knees, good in seven, and fair in three. The range of movement which was achieved intra-operatively was related to the gain of knee flexion on univariate analysis. Five patients had complications: deep infection in one, recurrent patellar dislocation in one, and rupture of the extensor mechanism in three. This modified technique gives satisfactory results. Achieving maximum knee flexion intra-operatively seems to be the most important factor in enhancing the outcome in patients with stiffness of the knee following fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 992 - 995
1 Sep 2000
Hahn SB Lee WS Han DY

Between March 1987 and March 1997, we performed a modified Thompson quadricepsplasty on 20 stiff knees and followed the patients for a mean of 35 months (24 to 52). After the operation, the knee was immobilised in flexion and periodically extended. At the final follow-up, the mean active flexion was 113.5° (75 to 150). The final mean gain in movement was 67.6° (5 to 105). One patient had a deep infection which resolved after wound care and intravenous antibiotics. The modified Thompson quadricepsplasty with appropriate postoperative care can give good results


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 333 - 336
1 Mar 2005
Bae DK Yoon KH Kim HS Song SJ

Between July 1986 and August 1996, we performed 32 total knee arthroplasties (TKA) on 32 patients with partially or completely ankylosed knees secondary to infection. Their mean age at surgery was 40 years (20 to 63) and the mean follow-up was ten years (5 to 13). The mean post-operative range of movement was 75.3° (30 to 115) in those with complete and 98.7° (60 to 130) in those with partial ankylosis. The mean Hospital for Special Surgery knee score increased from 57 to 86 points post-operatively. There were complications in four knees (12.5%), which included superficial infection (one), deep infection (one), supracondylar femoral fracture (one) and transient palsy of the common peroneal nerve (one). Although TKA in the ankylosed knee is technically demanding and has a considerable rate of complications, reasonable restoration of function can be obtained by careful selection of patients, meticulous surgical technique, and aggressive rehabilitation.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1640 - 1644
1 Dec 2015
Dzaja I Vasarhelyi EM Lanting BA Naudie DD Howard JL Somerville L McCalden RW MacDonald SJ

The purpose of this study was to compare clinical outcomes of total knee arthroplasty (TKA) after manipulation under anaesthesia (MUA) for post-operative stiffness with a matched cohort of TKA patients who did not requre MUA. . In total 72 patients (mean age 59.8 years, 42 to 83) who underwent MUA following TKA were identified from our prospective database and compared with a matched cohort of patients who had undergone TKA without subsequent MUA. Patients were evaluated for range of movement (ROM) and clinical outcome scores (Western Ontario and McMaster Universities Arthritis Index, Short-Form Health Survey, and Knee Society Clinical Rating System) at a mean follow-up of 36.4 months (12 to 120). MUA took place at a mean of nine weeks (5 to 18) after TKA. In patients who required MUA, mean flexion deformity improved from 10° (0° to 25°) to 4.4° (0° to 15°) (p < 0.001), and mean range of flexion improved from 79.8° (65° to 95°) to 116° (80° to 130°) (p < 0.001). There were no statistically significant differences in ROM or functional outcome scores at three months, one year, or two years between those who required MUA and those who did not. There were no complications associated with manipulation. At most recent follow-up, patients requiring MUA achieved equivalent ROM and clinical outcome scores when compared with a matched control group. While other studies have focused on ROM after manipulation, the current study adds to current literature by supplementing this with functional outcome scores. Cite this article: Bone Joint J 2015;97-B:1640–4


Bone & Joint Research
Vol. 11, Issue 1 | Pages 32 - 39
27 Jan 2022
Trousdale WH Limberg AK Reina N Salib CG Thaler R Dudakovic A Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen A Abdel MP

Aims. Outcomes of current operative treatments for arthrofibrosis after total knee arthroplasty (TKA) are not consistently positive or predictable. Pharmacological in vivo studies have focused mostly on prevention of arthrofibrosis. This study used a rabbit model to evaluate intra-articular (IA) effects of celecoxib in treating contracted knees alone, or in combination with capsular release. Methods. A total of 24 rabbits underwent contracture-forming surgery with knee immobilization followed by remobilization surgery at eight weeks. At remobilization, one cohort underwent capsular release (n = 12), while the other cohort did not (n = 12). Both groups were divided into two subcohorts (n = 6 each) – one receiving IA injections of celecoxib, and the other receiving injections of vehicle solution (injections every day for two weeks after remobilization). Passive extension angle (PEA) was assessed in live rabbits at 10, 16, and 24 weeks, and disarticulated limbs were analyzed for capsular stiffness at 24 weeks. Results. IA celecoxib resulted in greater mean PEA at ten weeks (69.6° (SD 4.6) vs 45.2° (SD 9.6), p = 0.004), 16 weeks (109.8° (SD 24.2) vs 60.9° (SD10.9), p = 0.004), and 24 weeks (101.0° (SD 8.0) vs 66.3° (SD 5.8), p = 0.004). Capsular stiffness was significantly reduced with IA celecoxib (2.72 Newton per cm (N·cm)/° (SD 1.04), p = 0.008), capsular release (2.41 N·cm/° (SD 0.80), p = 0.008), and capsular release combined with IA celecoxib (3.56 N·cm/° (SD 0.99), p = 0.018) relative to IA vehicle (6.09 N·cm/° (SD 1.64)). Conclusion. IA injections of a celecoxib led to significant improvements in passive extension angles, with reduced capsular stiffness, when administered to rabbit knees with established experimental contracture. Celecoxib was superior to surgical release, and the combination of celecoxib and a surgical release did not provide any additional value. Cite this article: Bone Joint Res 2022;11(1):32–39


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 5 - 5
1 Jul 2022
Smith J Stephens T Paulson K Schneider P Martin CR
Full Access

Abstract. Introduction. All-tissue quadriceps tendon (QT) is becoming an increasingly popular alternative to hamstrings tendon (HT) and bone-tendon-bone (BTB) autograft for anterior cruciate ligament (ACL) reconstruction. The relatively short graft length however dictates that one, or both, ends rely on suture fixation. The strength of this construct is therefore extremely important. This study evaluates whether the use of a novel fixation technique can improve the tensile properties of the construct compared to a Krackow suture, and a looped tendon (suture free) gold standard. Methods. Eighteen porcine flexor tendons were tested, across three groups; suture-tape Krackow, looped tendon, and the novel ‘strain suture’. Biomechanical testing simulated the different stages of ACL graft preparation and loading (60N preload for 10 minutes, 10 cycles from 10N to 75N, and 1000 cycles from 100N to 400N). Elongation and load to failure were recorded, and stiffness calculated for each construct. Results. The mean elongation was significantly improved for the strain suture compared to the suture tape Krackow for preload, 10 cycle and 1000 cycle testing protocols respectively (1.36mm vs 4.93mm, p<001; 0.60mm vs 2.72mm, p<0.001; 2.95mm vs 29.08mm, p<0.001). Compared with the looped tendon, the strain suture demonstrated similar results for preload and 10 cycle elongation, but greater elongation during the 1000 cycle stage. Stiffness of the latter two constructs was similar. Conclusions. Augmentation of the suture fixation using this novel technique provides a construct that is significantly superior to currently practised suture techniques, and similar in elongation and stiffness to a looped graft


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 47 - 47
7 Aug 2023
Reason L Jonas S Evans JT Eyres KS Toms AD Kalson NS Phillips JR
Full Access

Abstract. Introduction. Choosing a hinged implant in the revision knee arthroplasty (rTKA) setting is challenging and limited data on implant performance exists. We present the survivorship and reason for failure in rTKA performed at our institution using the LINK hinge prosthesis, predominantly the cemented modular Endo-Model prosthesis. Methodology. 260 consecutive revision knee cases performed between 2012 and 2020 were reviewed retrospectively. Mean follow up was 27 months (range 0 to 107). Survivorship was analysed in Stata using a Log Rank test to compare performance in patients stratified according to age (≥80 years old (76 cases), 70–79 years (104 cases) and ≤70 years (80 cases). Results. 53 patients died and 48/207 (23%) cases in 40 patients underwent re-revision. Reasons for re-revision were aseptic loosening (21), infection (12), instability (4), extensor failure (1), stiffness (1), fracture (1) and other (8). Loosening was seen in the femur (8), tibia (5), and both the femur and tibia (8). Sub-group analysis of patients according to age showed a significantly higher failure rate in younger patients (6 failures (8%) in patients ≥80, 27 failures (26%) in 70–79 and 15 (19%) in ≤70 (p = 0.02). Failure in patients ≤70 was predominantly due to aseptic loosening (8/15). Conclusion. Here we report a significantly higher rate of LINK hinge prostheses failure in patients <70 undergoing rTKA. Consent should consider the risk of re-revision in this patient group


Abstract. INTRODUCTION. The anatomic distal femoral locking plate (DF-LCP) has simplified the management of supracondylar femoral fractures with stable knee prostheses. Osteoporosis and comminution seem manageable, but at times, the construct does not permit early mobilization. Considerable soft tissue stripping during open reduction and internal fixation (ORIF) may delay union. Biological plating offsets this disadvantage, minimizing morbidity. Materials. Thirty comminuted periprosthetic supracondylar fractures were operated from October 2010 to August 2016. Fifteen (group A) were treated with ORIF, and fifteen (group B) with closed (biological) plating using the anatomical DF-LCP. Post-operatively, standard rehabilitation protocol was followed in all, with hinged-knee-brace supported physiotherapy. Clinico-radiological follow-up was done at 3 months, 6 months, and then yearly (average duration, 30 months), and time to union, complications, failure rates and function were evaluated. Results. Average time to union was 4.5 months (range, 3–6 months) in group A, and 3.5 months (range, 2.5–5 months) in group B. Primary bone grafting was done in twelve patients (all group A). At final follow-up, all fractures had healed, and all (but two) patients were walking unsupported, with no pain or deformity, with average knee range of motion (ROM) of 90° (range, 55 to 100°). Two patients had superficial infection (group A), two had knee stiffness (group A), one had shortening of 1.5cm (group B) and one had valgus malalignment of 10 degrees (group B). Conclusion. Biological plating in comminuted supracondylar fractures about stable TKA prostheses is an excellent option, may obviate need for bone grafting, and reducing complications


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 3 - 3
1 Jul 2022
Sheridan G Cassidy R McKee C Hughes I Hill J Beverland D
Full Access

Abstract. Introduction. With respect to survivorship following total knee arthroplasty (TKA), joint registries consistently demonstrate higher revision rates for both sexes in those less than 55 years. The current study analyses the survivorship of 500 cementless TKAs performed in this age group in a high-volume primary joint unit where cementless TKA has traditionally been used for the majority of patients. Methods. This was a retrospective review of 500 consecutive TKAs performed in patients under the age of 55 between March 1994 and April 2017. The primary outcome measure for the study was all-cause revision. Secondary outcome measures included clinical, functional and radiological outcomes. Results. The all-cause revision rate was 1.6% (n=8) at a median of 55.7 months. Four were revised for infection, 2 for stiffness, 1 for aseptic loosening of the tibial component and 1 patella was resurfaced for anterior knee pain. The aseptic revision rate was 0.8% (n=4). Twenty-seven (5.4%) patients underwent a manipulation under anaesthetic (MUA). Including those who underwent MUA, 6.8% (n=34) underwent other non-revision procedures. Conclusion. Survivorship in our unit in this young patient cohort was excellent with an aseptic revision rate of 0.8% at 59.7 months using a fully cementless construct. The MUA rate was higher than expected


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 38 - 38
1 Jul 2022
Fu H Peacock C Wang C Kader D Clement N Asopa V Sochart D
Full Access

Abstract. Aim. End-stage arthropathy is a well-known complication of haemophilia, with recurrent haemarthroses leading to joint destruction, deformity, pain, and stiffness. In the knee, this is often treated with total knee arthroplasty (TKA), which can be more challenging in patients with haemophilia (PwH) and associated with poorer outcomes. We conducted a systematic literature review and meta-analysis to determine implant survivorship, functional outcomes and complication rates. Method. A systematic review was conducted using MEDLINE, EMBASE, and PubMed for studies reporting TKA outcomes with Kaplan-Meier survivorship in PwH (PROSPERO registered). Meta-analysis was performed for survivorship and outcomes, and the results were compared to outcomes from the National Joint Registry (NJR). Results. 19 studies, totalling 1187 TKAs (average age 39 years) were reviewed. In PwH, implant survivorship at 5, 10, and 15 years was 94%, 86%, and 76% respectively, whereas NJR reported survivorship for males <55 years was 94%, 90%, and 86%. Survivorship generally improved over the time period studied (1973–2017), but was inversely correlated with HIV infection (common in PwH). Range of motion improved by 10–20° post-operatively, and there were large improvements in Patient Reported Outcome Measures (PROMS). The prosthetic joint infection rate (PJI) was 6% compared to 0.5-1% in non-PwH, but the reporting of other complications, especially haematological, was inconsistent. Conclusions. TKA in PwH has similar 5-year survivorship to non-PwH, but a six-fold higher infection rate. There were marked improvements in range of motion and PROMS, but complications were poorly reported. There remains a need for larger, long-term studies with standardised reporting


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 73 - 73
1 Jul 2022
Aspinall S Godsiff S Wheeler P Hignett S Fong D
Full Access

Abstract. 20% of patients are severely dis-satisfied following total knee arthroplasty (TKA). Arthrofibrosis is a devastating complication preventing normal knee range of motion (ROM), severely impacting patient's daily living activities. A previous RCT demonstrated superiority of a high intensity stretching programme using a novel device the STAK tool compared with standard physiotherapy in TKA patients with arthrofibrosis. This study analyses the results when the previous “standard physiotherapy” group were subsequently treated with the STAK tool. Methods. 15 patients post TKA with severe arthrofibrosis and mean ROM 71° were recruited, (three cases had previously failed manipulation under anaesthetic (MUA). Patients received 8 weeks standard physiotherapy, then treatment with the STAK at home for 8 weeks. ROM, extension, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Oxford Knee Scores (OKS) were collected at various time-points. Results. Following standard physiotherapy there were small improvements in ROM (8°) (p<0.01), but no significant improvements in extension, OKS or WOMAC (p=0.39). Following the STAK treatment all outcomes significantly improved (p<0.01). STAK group; mean ROM (21° versus 8°, p < 0.001), extension 9° versus 2° (p < 0.01), WOMAC (18 points versus 3, p < 0.01), and OKS (8 points versus 4, p<0.01). No patients suffered any complications relating to the STAK. Conclusions. The STAK is effective in increasing ROM, extension and function, whilst reducing pain and stiffness. The device can be considered a cost-effective and valuable treatment following TKA. This is likely to increase the overall satisfaction rate and has potential to reduce the need for MUA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 24 - 24
1 Jul 2022
Spolton-Dean C Burden E East J Toms A Bhamber N Waterson B
Full Access

Abstract. Introduction. OtisMed Shape Match ® patient specific implant cutting jigs were designed to place TKA in kinematic alignment (KA) rather than traditional mechanical alignment (MA). This product was withdrawn from the market in 2013. It has been hypothesised that KA might lead to early implant failure. Initial evidence has not supported this. We present 10 year outcome data for the largest single centre cohort to date. Methodology. Between 2010 and 2013, 127 Shape Match® TKAs were implanted in 119 individuals. Retrospective review of long leg post-operative radiographs assessed femoral mechanical anatomical angle (FMA), tibial mechanical angle (TMA), hip-knee-ankle angle (HKA), posterior tibial slope (PTS) and femoral component flexion. Oxford Knee Scores (OKS), revision and further surgery rates were reviewed. Results. 4 (3.1%) patients underwent revision for instability, recurrent haemarthrosis, stiffness and infection respectively. In this subgroup, PTS ranged from 9–25° (SD 7.5°). PTS range for non-revision subgroup was 1–23° (SD 4.6). 1 patient with a PTS of 21° had failure of quadriceps tendon, but was not revised. Mean OKS at 1year = 38.1 (SD 1.08), 2 years = 39.3 (SD 1.08), 5 years = 40.8 (SD 4.11). PTS had the largest impact on OKS, with <10° slope conferring a higher OKS. Conclusions. At 10 year follow up, this cohort did identify several cases where excessive PTS was evident. This may have led to revision surgery and contributed post-operative complications. PTS, unlike other alignment measures, impacted OKS results. Overall revision rate and OKS were consistent with registry and other published data