Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_8 | Pages 4 - 4
1 May 2021
Nicholas PRM Shields DW Mthethwa J Jamal B
Full Access

Gavril Ilizarov advocated a fine wire tension of between 900N and 1200N for circular frame construction. Wire tension can be achieved via a tensioning device or ‘Russian tensioning’ (a fixed wire lengthening around a bolt). There is limited information on the latter technique. This study explored the tensions achieved via Russian tensioning and reports the impact of a second wire on construct tension. A single 160mm stainless-steel ring was constructed, then 1.8mm stainless steel wires were secured using a Russian fixation bolt and Russian tensioned with a 2nd bolt. The angle subtended by tensioning using the 2nd bolt was measured using a goniometer. Angles of 45°, 70° and 90° were repeated in triplicates, with wire tension measured using a calibrated tensiometer. A second, orthogonal wire was added and tensioned to the same angle. Tensions of both wires were remeasured and recorded. Unpaired t-tests were used to compare mean tensions. A value of p<0.05 was considered significant. Tensioning at all angles was insufficient to achieve the target range of 900–1200N (range 99–110N). A second, orthogonal wire changed frame dynamics such that a 90° angle resulted in both wires achieving adequate tension (mean 1143N, SD 307N). Increases were significant across all tensioning angles (p=<0.002) however only biomechanically relevant for 90°. Russian tensioning is insufficient with a single wire, however the addition of an orthogonal wire increases tension in both wires, reaching the target range at 90° deflection. Further study using wire tensioners is warranted, and also the impact of non-orthogonal wire constructs


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1343 - 1347
1 Oct 2017
Yalizis MA Ek ETH Anderson H Couzens G Hoy GA

Aims

To determine whether an early return to sport in professional Australian Rules Football players after fixation of a non-thumb metacarpal fracture was safe and effective.

Patients and Methods

A total of 16 patients with a mean age of 25 years (19 to 30) identified as having a non-thumb metacarpal fracture underwent open reduction and internal plate and screw fixation. We compared the players’ professional performance statistics before and after the injury to determine whether there was any deterioration in their post-operative performance.