Advertisement for orthosearch.org.uk
Results 1 - 20 of 47
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 32 - 32
1 Sep 2012
Friedl W Wright J
Full Access

The avulsion fracture of the V-th metatarsal and Jones fractures often show delayed and non-union. The tension belt osteosynthesis shows often soft tissue problems due to the thin soft tisshe covering. A new minimal invasive method with the 3,5mm XXS nail and the clinical results are presented. Percutaneously the fracture is reduced with a K-wire as a joy stick. This or if the direction needed is different a second K-wire as guide is introduced and with a canulated 3,5 mm drill the place for the nail is prepared. Proximal and distal to the fracture one threaded wire locking and fracture compression through the nail (proximal longitudinal holes) are performed. 77 patients with a XXS nail fixation of MT V fractures were treated from July 1999 to Jan.2006. Clinical and radiological re-examination at 1 to 6 years were performed. The AOFAS was 22 pre- and 96 postoperatively. No pseudarthrosis but in 53 patients implant removal was done in part due to local discomfort. This was strictly correlated to the length of the threaded wires to the bone surface. 95% reached pretrauma activity levels. Satisfaction was 9 from 10 points. The XXS nails allow a percutaneous stable fixation of the avulsion and Jones fractures of the V-th metatarsus. The complication rate is low


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 358 - 361
1 Mar 2006
Prathapkumar KR Garg NK Bruce CE

Several techniques are available for the treatment of displaced fractures of the neck of the radius in children. We report our experience in 14 children treated by indirect reduction and fixation using an elastic stable intramedullary nail. The patients were followed up for a mean of 28 months. One developed asymptomatic avascular necrosis. The rest had excellent results. One had a neuropraxia of the posterior interosseous nerve, which recovered within six weeks. We advocate elastic stable intramedullary nailing for the closed reduction and fixation of these fractures in children.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 766 - 771
1 Jun 2020
Coughlin TA Nightingale JM Myint Y Forward DP Norrish AR Ollivere BJ

Aims. Hip fractures in patients < 60 years old currently account for only 3% to 4% of all hip fractures in England, but this proportion is increasing. Little is known about the longer-term patient-reported outcomes in this potentially more active population. The primary aim is to examine patient-reported outcomes following isolated hip fracture in patients aged < 60 years. The secondary aim is to determine an association between outcomes and different types of fracture pattern and/or treatment implants. Methods. All hip fracture patients aged 18 to 60 years admitted to a single centre over a 15-year period were used to identify the study group. Fracture pattern (undisplaced intracapsular, displaced intracapsular, and extracapsular) and type of operation (multiple cannulated hip screws, angular stable fixation, hemiarthroplasty, and total hip replacement) were recorded. The primary outcome measures were the Oxford Hip Score (OHS), the EuroQol five-dimension questionnaire (EQ-5D-3L), and EQ-visual analogue scale (VAS) scores. Preinjury scores were recorded by patient recall and postinjury scores were collected at a mean of 57 months (9 to 118) postinjury. Ethics approval was obtained prior to study commencement. Results. A total of 72 patients were included. There was a significant difference in pre- and post-injury OHS (mean 9.8 point reduction (38 to -20; p < 0.001)), EQ-5D (mean 0.208 reduction in index (0.897 to -0.630; p < 0.001)), and VAS , and VAS (mean 11.6 point reduction (70 to -55; p < 0.001)) Fracture pattern had a significant influence on OHS (p < 0.001) with extracapsular fractures showing the least favourable long-term outcome. Fixation type also impacted significantly on OHS (p = 0.011) with the worst outcomes in patients treated by hemiarthroplasty or angular stable fixation. Conclusion. There is a significant reduction in function and quality of life following injury, with all three patient-reported outcome measures used, indicating that this is a substantial injury in younger patients. Treatment with hemiarthroplasty or angular stable devices in this cohort were associated with a less favourable hip score outcome. Cite this article: Bone Joint J 2020;102-B(6):766–771


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 172 - 172
1 Sep 2012
Wirtz C Herold F Gerber Popp A
Full Access

OBJECTIVES. In elderly patients the temporary loss of function of the upper extremity due to immobilization for treatment of unstable proximal humeral fractures is a very disabling condition. Stable fixation of such fractures allowing immediate functional aftercare may contribute to early social reintegration in this group of patients. Aim of this study is to present the surgical technique of humeral blade plate fixation and the clinical and radiographic results after fixation of unstable surgical neck fractures with this implant followed by immediate functional treatment in patients older than 60 years. PATIENTS. 20 patients (4 male, 16 female) with a mean age of 74 years (59y–93y) were included in this study and treated consecutively for an unstable/displaced surgical neck fracture with a humeral blade plate. Postoperatively functional treatment was allowed. All but one patient had a clinical and radiographic follow-up 6 weeks po. At an average final follow-up of 18,8 months (12–24 months) 4 patients had died from causes unrelated to surgery. RESULTS. Surgery was performed in all patients without local or general complications despite comorbidities. In all patients anatomic reduction and stable fixation could be achieved. 6 weeks po all patients (N=20) were free of pain at rest, 7 patients had low pain (VAS < 4) when actively moving the arm. All patients used their operated arm for ADL and were back home or in the institution they came from at the time of trauma. All fractures were deamed to be healed without implant failure. In two cases a clinically asymptomatic 1–2mm protrusion of the blade through the subchondral bone was observed, but did not required further surgery. At final follow-up (N=8) the average absolute Constant/Murley Score was 68,6 points (contralateral 71,4). Radiographically all fractures had healed without complications. Implant removal was not required. CONCLUSION. Humeral blade plate fixation combined with suture tension-banding of the rotator cuff allows indirect reduction, dynamic and stable osteosynthesis of unstable surgical neck fractures even in osteoporotic bone. In our small series, this technique has shown to be a safe and reliable therapeutic option allowing immediate functional treatment and thus early social reintegration in elderly patients


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 503 - 509
1 Apr 2007
Giannoudis PV Tzioupis C Moed BR

Our aim was to evaluate the efficacy of a two-level reconstruction technique using subchondral miniscrews for the stabilisation of comminuted posterior-wall marginal acetabular fragments before applying lag screws and a buttress plate to the main overlying posterior fragment. Between 1995 and 2003, 29 consecutive patients with acute comminuted displaced posterior-wall fractures of the acetabulum were treated operatively using this technique. The quality of reduction measured from three standard plain radiographs was graded as anatomical in all 29 hips. The clinical outcome at a mean follow-up of 35 months (24 to 90) was considered to be excellent in five patients (17%), very good in 16 (55%), good in six (21%) and poor in two (7%). The use of the two-level reconstruction technique appears to provide stable fixation and is associated with favourable results in terms of the incidence of post-traumatic osteoarthritis and the clinical outcome. However, poor results may occur in patients over the age of 55 years


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 332 - 335
1 Apr 2000
Paramasivan ON Younge DA Pant R

Nonunion of fractures of the olecranon fossa of the humerus presents a difficult surgical problem. The distal fragment is usually small and osteoporotic and stable fixation is not easy to achieve. We describe a modification of the technique of locked nailing by which the distal aspect of the nail is placed in the subchondral region of the trochlea. Good results were obtained in seven out of eight patients with this technique


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 340 - 344
1 Apr 2000
Jakob M Rikli DA Regazzoni P

Stable fixation of fractures of the distal radius can be achieved by using two 2.0 mm titanium plates placed on the radial and intermediate columns angled 50° to 70° apart. We describe our results with this method in a prospective series of 74 fractures (58 severely comminuted) in 73 consecutive patients. Early postoperative mobilisation was possible in all except four wrists. All of the 73 patients, except two with other injuries, returned to work and daily activities with no limitations. The anatomical results were excellent or good in 72 patients and fair in one. Our discussion includes details of important technical considerations based on an analysis of the specific complications which were seen early in the series


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 748 - 752
1 Sep 1997
Song H Cho S Jeong S Park Y Koo K

Stable fixation after a corrective supracondylar osteotomy in adults is difficult because of the irregularity of the area of bony contact, displacement of the fragments, the predominance of cortical bone, and the need for early mobilisation. We have used the Ilizarov apparatus for fixation in 15 patients who were treated by complex osteotomies with displacement of fragments for cubitus varus or valgus. Most patients with cubitus varus required medial displacement with rotation of the distal fragment. Those with cubitus valgus required lateral shift of the distal fragment to reduce the medial prominence of the elbow that would otherwise result. All osteotomies united within the expected time without loss of correction, despite early mobilisation. Complications related to the fixation were few and had resolved at the long-term follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1206 - 1209
1 Sep 2007
Moonot P Ashwood N Hamlet M

Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population. This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 227 - 227
1 Sep 2012
Vaculik J Horak M Malkus T Majernicek M Dungl P Podskubka A
Full Access

Unstable intertrochanteric fractures may be treated by several types of implants, most frequently by dynamic sliding hip screw or some form of intramedullary implant. Intramedullary implants began to be used in cases with an expectation of further improvement of osteosynthesis stability. A need to determine the advantages of single implants for selected types of fractures in randomized trials was defined. In addition to biomechanical principles, bone quality is considered, together with increasing possibilities in recent years of further improving density measurements, especially qCT with respect to local specificity. A series of 86 patients (24 men, 62 women, average age 77,6 years) was operated on from September 6, 2005 to June 30, 2009 for unstable intertrochanteric fracture (31 A2.1, A2.2, A2.3), either by DHS of PFN osteosynthesis after randomization. A CT examination of both hip joints in a predefined manner was performed before surgery. Using special software the relative density of the central spherical part of the femoral head 2 and 3 centimetres in diameter was determined. After fracture healing, the dynamization of the neck screw of both implants and the reduction of vertical distance between the tip of the neck screw and subchondral bone of the femoral head were determined. In addition to evaluation of osteosynthesis stability and osteosyntheis failure, clinical parameters such as surgical time, blood loss and length of hospital stay were compared between the two groups of patients. Survival of patients was evaluated with respect to April 21, 2010. In the patient series, 4 failures of DHS osteosynthesis (cut out) and 2 failures of PFN osteosynthesis (cut out) were noted. Sliding of the DHS was on average 11,9 mm, and was significantly higher in comparison to dynamization of the PFN neck screw, which was 6,9 mm (p=0,005). When comparing the vertical distance between the tip of the neck screw and subchondral bone of the femoral head immediately after surgery and after fracture healing the average reduction of the vertical distance was 1,6 mm in DHS osteosynthesis and 0,8 mm in PFN osteosynthesis. The difference was statistically significant (p=0,025). PFN seems to provide a more stable fixation, based on the measurements. The number of failed DHS osteosyntheses is higher in comparison to the number of failed PFN osteosyntheses but the difference is not statistically significant. The influence of femoral head density on osteosynthesis failure could not be determined due to a low number of failed osteosyntheses in both patient groups. At the same time, after statistical analysis, influence of the relative femoral head density on vertical distance reduction between the screw tip and femoral head subchondral bone in healed fractures was not proven. Statistically, average length of surgical time, length of hospital stay, mean blood loss and survival did not differ significantly between the two patient groups


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 497 - 497
1 Sep 2012
Spalazzi J Baldini T Efird C Traub S Hiza E Cook S Rioux-Forker D Mccarty E
Full Access

Summary. Strong mechanical fixation is critical to the success of rotator cuff repairs. In this comparative study in cadaveric shoulders, single-tendon full-thickness supraspinatus tears were repaired using two different types of PEEK knotless suture anchors-ReelX STT (Stryker) and Opus Magnum PI (Arthrocare)-using a single-row technique in both instances. Cyclic testing was performed followed by loading until mechanical failure. No significant difference was observed in gap formation, measured as the distance between the supraspinatus tendon and bone at the repair site, during cyclic loading. However, the maximum load was statistically higher for repairs with the ReelX anchor. Purpose. The objective of this study was to compare the gap formation during cyclic loading and maximum repair strength of single-row full thickness supraspinatus repairs performed using two different types of PEEK knotless suture anchors in a cadaveric model. Methods. Nine matched pairs of cadaveric shoulders were used in this study. All soft tissue was removed except for the supraspinatus, and a full thickness tear was formed. Single-row repairs were performed with two anchors per repair using either the Opus Magnum PI (Arthrocare) or the ReelX STT (Stryker). The specimens were mounted to an Instron at 45° to simulate an anatomic direction of load, and fiducial markers were placed on the repair in anterior and posterior positions. A 10 N preload was applied and held for 60 seconds, and then the tendon was cycled from 10 N to 90 N at 0.25 Hz for 500 cycles, followed by load to failure at 1 mm/s. A video digitizing system was used to track the markers and measure gap formation during loading. Gap formation was calculated by subtracting the distance between the markers at 10 N preload from the maximum displacement at 5 and 500 cycles. Paired t-tests were used to compare the cyclic displacement and max load. Results. One specimen from each of two matched pairs (one from each anchor group) failed during cyclic loading, leaving seven matched pairs for analysis. No significant difference was found in cyclic displacement between the two groups in either anterior or posterior positions at 5 and 500 cycles. However, maximum load to failure was significantly greater for repairs performed with the ReelX STT anchors (289N ± 57N) as compared to the OPUS anchors (178N ± 36N), with a p=0.009. Conclusions. These results suggest that the anchor type chosen for cuff repairs may affect the overall stability of the repair. Achieving stable fixation is critical for promoting healing of the tendon back to bone and to the long-term success of the repair, and using anchors that provide stronger fixation may decrease the occurrence of post-surgical tears and instability. The ReelX STT anchor outperformed the Opus Magnum PI anchor in terms of supporting significantly higher loads before failure, potentially leading to stronger repairs clinically


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 50 - 50
1 Sep 2012
Maempel J Ward A Chesser T Kelly M
Full Access

Background. Tightrope fixation has been suggested as an alternative to screw stabilisation for distal tibiofibular joint diastasis that provides stability but avoids the problems of rigid screws across the joint. Recent case series (of 6 and 16 patients) have however, reported soft tissue problems and infections in 19–33% of patients. This study aims to review treatment and complications of distal tibiofibular diastasis fixation in our unit with the use of Tightrope or diastasis screws. Methods. Retrospective review of all patients undergoing primary ankle fixation between May 2008 and October 2009. Exclusions included revision procedures, or ankle fixation prior to the current fracture. Those undergoing Tightrope or diastasis screw fixation were studied for any complications or further procedures. Clinical records and XRAYs were reviewed, family practitioners of the patients were contacted and any consultations for ankle related problems noted. Results. 187 primary ankle fixation procedures were performed. 35 ankles required stabilisation of the distal tibiofibular joint. In 12, this was achieved using the Tightrope and in 23, syndesmotic screws were used. There was no difference in the adequacy of reduction in the two groups. Of those stabilised with a Tightrope, 6 were Maisonneuve injuries, 5 Weber C and 1 Weber B. 1 was lost to followup. Of the remaining 11, none had complications attributable to the method of fixation documented in hospital or family practitioner records. One had a small stitch abscess that settled on removal of the suture material. None underwent subsequent procedures. Of 23 stabilised with screws, 4 were Weber B, 14 Weber C, 4 Maisonneuve and 1 syndesmotic injury associated with an isolated posterior malleolus fracture. In this group of patients with primary ankle fixation involving a diastasis screw there was 1 deep infection requiring removal of metalwork, 1 superficial wound infection after syndesmotic screw removal and 1 wound breakdown after syndesmotic screw removal. A patient developed superficial peroneal nerve palsy at operation and 1 syndesmotic fixation failed and underwent revision surgery. This patient subsequently developed infection and had revision to a hindfoot nail. 19 patients underwent screw removal. The 23 patients underwent 45 procedures (mean 1.96 procedures per patient). Conclusion. In a consecutive series of 187 ankle procedures, 12 had the distal tibiofibular joint stabilised with a Tightrope with no noted complications attributable to the implant and no additional procedures. 23 patients underwent diastasis screw fixation with 19 screw removal procedures and 5 complications of various severity, 2 of which were attributable to screw removal. Tightrope fixation has provided stable fixation of the injured syndesmosis in our unit and we have not to date encountered complications previously described in the literature


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 99 - 99
1 Sep 2012
Maempel J Coathup M Calleja N Maempel FZ Briggs T Cannon S Blunn G
Full Access

Background/Aims. The development of extendable prostheses has permitted limb salvage surgery in paediatric patients with bone tumours in proximity to the physis. Prostheses are extended to offset limb length discrepancy as the child grows. Aseptic loosening (AL) is a recognised complication. The implant stem must fit the narrow paediatric medullary canal and remain fixed while withstanding growth and increasing physical demands. Novel designs incorporate a hydroxyapatite (HA) coated collar that manufacturers claim improves bony ongrowth and stability, providing even stress distribution in stem and shoulder regions and providing a bone-implant seal, resulting in decreased AL and prolonged survival. This study aims to assess whether there is a relationship between bony ongrowth onto a HA collar and AL. Hypothesis: Bone ongrowth onto the HA collar of extendable prostheses is associated with more stable fixation and less AL despite patient growth. Methods. Retrospective review of 51 primary partial femoral extendable prostheses implanted over 12 years from 1994–2006 (followed up to death at a mean of 2.5±2.2 years or last clinical encounter at a mean of 8.6 years) and 24 subsequent revisions, to ascertain failure rate and mode, together with a cohort study reviewing bony ongrowth onto the HA coated collar in 10 loose and 13 well fixed partial femoral, humeral and tibial implants. Patient growth was measured as a change in bone:implant-width ratio. Results. 21 (41.2%) primary femoral implants failed at a mean 42.8 months, 5 through AL. 1 secondary implant was revised for AL. 2 implants displayed evidence of progressive AL but had not failed at last follow-up. 5 of 11 tibial component revisions in distal femoral replacement were due to AL. 1 major complication occurred after revision surgery for AL in a primary implant: deep infection requiring 2 stage revision. Bony collar ongrowth was significantly higher in all 4 quadrants (anterior, posterior, medial and lateral) in the well-fixed as opposed to loose group, demonstrating a strong negative relationship in each quadrant between bony ongrowth and AL (p0.001) in the presence of patient growth as shown by increased bone:implant width ratio. In both groups, collar ongrowth was greatest in the posterior quadrant. Summary and Conclusions: AL has been confirmed as a common cause of failure in massive extendable endoprostheses. Revision surgery is difficult and may cause serious complications. For the first time, a significant relationship between a well fixed implant stem and bony ongrowth onto a HA coated collar in the context of massive implants used in tumour surgery has been demonstrated. This newly-proven relationship may result in longer-term implant survival and thus a reduced need for revision surgery. It is hoped that this study will provide the basis for further study of this relationship


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 155 - 161
1 Feb 2020
McMahon SE Diamond OJ Cusick LA

Aims

Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort.

Methods

We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 33 - 41
1 Jan 2020
Norman JG Brealey S Keding A Torgerson D Rangan A

Aims

The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures

Methods

A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1009 - 1014
1 Aug 2019
Ramoutar DN Lefaivre K Broekhuyse H Guy P O’Brien P

Aims

The aim of this study was to determine the trajectory of recovery following fixation of tibial plateau fractures up to five-year follow-up, including simple (Schatzker I-IV) versus complex (Schatzker V-VI) fractures.

Patients and Methods

Patients undergoing open reduction and internal fixation (ORIF) for tibial plateau fractures were enrolled into a prospective database. Functional outcome, using the 36-Item Short Form Health Survey Physical Component Summary (SF-36 PCS), was collected at baseline, six months, one year, and five years. The trajectory of recovery for complex fractures (Schatzker V and VI) was compared with simple fractures (Schatzker I to IV). Minimal clinically important difference (MCID) was calculated between timepoints. In all, 182 patients were enrolled: 136 (74.7%) in simple and 46 (25.3%) in complex. There were 103 female patients and 79 male patients with a mean age of 45.8 years (15 to 86).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 588 - 592
1 Jul 1996
Rikli DA Regazzoni P

Fractures of the distal end of the radius should be treated on the same principles as other fractures involving joints. Displaced articular fractures require open reduction to allow anatomical reconstruction of both the radiocarpal and the radio-ulnar joints. For extra-articular fractures with severe comminution and shortening this enables the radial length to be re-established achieving radio-ulnar congruency. Stable internal fixation can be achieved with two 2.0 AO titanium plates placed on each of the ‘lateral’ and the ‘intermediate’ columns of the wrist at an angle of 50° to 70°. This gives good stability despite the tiny dimensions of the plates, and allows early function. We report a series of 20 fractures treated by this method of internal fixation with satisfactory results in all