Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims. Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results. Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion. While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article: Bone Jt Open 2022;3(6):495–501


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 21 - 21
1 Oct 2020
Yang J Olsen AS Serino J Terhune EB Della Valle CJ
Full Access

Introduction. The proportion of arthroplasties performed in the ambulatory setting has increased substantially. However, concerns remain regarding whether same-day discharge may increase the risk of complications. The purpose of this study was to compare 90-day outcomes between inpatients and patients having surgery at an ambulatory surgery center (ASC). Methods. Among a single-surgeon cohort of 721 patients who underwent arthroplasty at a free-standing ASC, 611 (84.7%) were matched one-to-one to inpatients based on age, gender, American Society of Anesthesiologists (ASA) score, and Body Mass Index (110 patients could not be adequately matched). The cohort included 208 total hip arthroplasties (34.0%), 196 total knee arthroplasties (32.1%), 178 unicompartmental knee arthroplasties (29.1%), 25 hip resurfacings (4.1%), two revision hip arthroplasties (0.3%) and two revision knee arthroplasties (0.3%). Post-operative outcomes including readmissions, reoperations, unplanned clinic visits, emergency department visits, and complications were compared. Complications were classified as either major (i.e. death, periprosthetic joint infection, pulmonary embolism) or as minor (i.e. delayed wound healing, rashes, urinary retention). Results. The inpatient and outpatient groups were similar in all demographic variables, reflecting successful matching. The rates of any complications (4.1% outpatient vs. 5.1% inpatient, p=0.41), minor complications (2.6% vs. 3.4%; p=0.40), readmissions (1.6% vs. 2.0%; p= 0.67), reoperations (0.7% vs. 1.1%; p=0.36), and unplanned clinic visits (5.4% vs 6.7%; p=0.34) were all lower amongst the outpatient group but did not reach significance with the sample size studied. The rate of major complications was the same in both groups (1.6% for both; p=1.0) while patients who underwent surgery at an ASC had significantly fewer emergency department visits (1.0% vs. 3.1%; p=0.009). Conclusions. Arthroplasty performed in the ambulatory setting appears to be safe in properly selected patients. However, this finding may be partly due to selection bias and intangible characteristics that were not adequately controlled for through matching


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 31 - 31
1 Oct 2018
Wyles CC Robinson WA Maradit-Kremers H Houdek MT Trousdale RT Mabry TM
Full Access

Introduction. Bilateral total knee arthroplasty (TKA) can be performed under a single-anesthetic (SA) or staged under a two-anesthetic (TA) technique. Recently, our institution began piloting a two-surgeon team SA method for bilateral TKA. The purpose of this study was to compare the inpatient costs and clinical outcomes in the first 90 days after surgery between the team SA, single-surgeon SA, and single-surgeon TA approaches for bilateral TKA. Methods. All primary TKA performed from 2007–2017 by the two participating surgeons for each of the 3 groups of interest were identified: team SA (N=42 patients; 84 knees), single-surgeon SA (N=146 patients; 292 knees), single-surgeon TA (N=242 patients; 484 knees). No patients were lost to follow-up. Results. Median hospital cost (per TKA) for the episode(s) of care was as follows: team SA $20,962, single-surgeon SA $22,057, single-surgeon TA $31,145 (p<0.001 overall; p=0.0905 team SA vs single-surgeon SA). Rate of 90-day complications was 2.4% for team SA, 11.0% for single-surgeon SA, and 8.3% for single-surgeon TA (p=0.2090). Discharge to skilled nursing facilities or rehab was as follows: team SA 31%, single-surgeon SA 53% and single-surgeon TA after the second operation 34% (p<0.001). Conclusions. This pilot project suggests that team SA bilateral TKA is a potentially cost-effective option with fewer complications compared to single-surgeon SA bilateral TKA. The less frequent disposition to skilled nursing facilities in the team SA group in conjunction with more efficient OR utilization may further enhance the financial benefits


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 8 - 8
1 Jul 2022
Dalal S Guro R Kotwal R Chandratreya A
Full Access

Abstract. Methodology. Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. 76 cases (mean age of 33.2 years) who had primary ACL reconstruction with BTB or quadriceps tendon with bone block, were divided into 2 matched groups (age, sex and type of graft) of 38 each based on the method of femoral fixation used (interference screw or adjustable cortical suspension). Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Complications and return to theatre were noted. Paired two-tailed student t-tests and Chi-square tests were employed for statistical analysis. Results. At a mean follow-up of 82 months, peri-operative mean EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.05), but no significant difference between the two groups (p>0.05). Mean graft length and diameter was 77mm and 9.3 respectively. Mean interval from injury to surgery was 10.5 months. 18(23.7%) patients had associated meniscal tear with 73.3 % undergoing repair. 10 cases (13.2 %) returned to theatre including, MUA for arthrofibrosis (n=2) and intra-substance graft failure (n=2). 3 cases had to be converted to interference screw fixation due to the tightrope cutting through from the femoral bone block as a result of a technical pitfall. Conclusion. Primary ACL reconstruction using adjustable cortical suspension on femoral side for BTB or quadriceps bone-block tendon graft is a safe technique with added advantages of 360 degree bone ingrowth and no screw in the femoral tunnel


Bone & Joint Open
Vol. 2, Issue 5 | Pages 305 - 313
3 May 2021
Razii N Clutton JM Kakar R Morgan-Jones R

Aims. Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Two-stage revision has traditionally been considered the gold standard of treatment for established infection, but increasing evidence is emerging in support of one-stage exchange for selected patients. The objective of this study was to determine the outcomes of single-stage revision TKA for PJI, with mid-term follow-up. Methods. A total of 84 patients, with a mean age of 68 years (36 to 92), underwent single-stage revision TKA for confirmed PJI at a single institution between 2006 and 2016. In all, 37 patients (44%) were treated for an infected primary TKA, while the majority presented with infected revisions: 31 had undergone one previous revision (36.9%) and 16 had multiple prior revisions (19.1%). Contraindications to single-stage exchange included systemic sepsis, extensive bone or soft-tissue loss, extensor mechanism failure, or if primary wound closure was unlikely to be achievable. Patients were not excluded for culture-negative PJI or the presence of a sinus. Results. Overall, 76 patients (90.5%) were infection-free at a mean follow-up of seven years, with eight reinfections (9.5%). Culture-negative PJI was not associated with a higher reinfection rate (p = 0.343). However, there was a significantly higher rate of recurrence in patients with polymicrobial infections (p = 0.003). The mean Oxford Knee Score (OKS) improved from 18.7 (SD 8.7) preoperatively to 33.8 (SD 9.7) at six months postoperatively (p < 0.001). The Kaplan-Meier implant survival rate for all causes of reoperation, including reinfection and aseptic failure, was 95.2% at one year (95% confidence interval (CI) 87.7 to 98.2), 83.5% at five years (95% CI 73.2 to 90.3), and 78.9% at 12 years (95% CI 66.8 to 87.2). Conclusion. One-stage exchange, using a strict debridement protocol and multidisciplinary input, is an effective treatment option for the infected TKA. This is the largest single-surgeon series of consecutive cases reported to date, with broad inclusion criteria. Cite this article: Bone Jt Open 2021;2(5):305–313


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 108 - 116
1 Jan 2020
Burger JA Kleeblad LJ Laas N Pearle AD

Aims. Limited evidence is available on mid-term outcomes of robotic-arm assisted (RA) partial knee arthroplasty (PKA). Therefore, the purpose of this study was to evaluate mid-term survivorship, modes of failure, and patient-reported outcomes of RA PKA. Methods. A retrospective review of patients who underwent RA PKA between June 2007 and August 2016 was performed. Patients received a fixed-bearing medial or lateral unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA), or bicompartmental knee arthroplasty (BiKA; PFA plus medial UKA). All patients completed a questionnaire regarding revision surgery, reoperations, and level of satisfaction. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed using the KOOS for Joint Replacement Junior survey. Results. Mean follow-up was 4.7 years (2.0 to 10.8). Five-year survivorship of medial UKA (n = 802), lateral UKA (n = 171), and PFA/BiKA (n = 35/10) was 97.8%, 97.7%, and 93.3%, respectively. Component loosening and progression of osteoarthritis (OA) were the most common reasons for revision. Mean KOOS scores after medial UKA, lateral UKA, and PFA/BiKA were 84.3 (SD 15.9), 85.6 (SD 14.3), and 78.2 (SD 14.2), respectively. The vast majority of the patients reported high satisfaction levels after RA PKA. Subgroup analyses suggested tibial component design, body mass index (BMI), and age affects RA PKA outcomes. Five-year survivorship was 98.4% (95% confidence interval (CI) 97.2 to 99.5) for onlay medial UKA (n = 742) and 99.1% (95% CI 97.9 to 100) for onlay medial UKA in patients with a BMI < 30 kg/m. 2. (n = 479). Conclusion. This large single-surgeon study showed high mid-term survivorship, satisfaction levels, and functional outcomes in RA UKA using metal-backed tibial onlay components. In addition, favourable results were reported in RA PFA and BiKA. Cite this article: Bone Joint J 2020;102-B(1):108–116


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1033 - 1042
1 Aug 2018
Kayani B Konan S Pietrzak JRT Huq SS Tahmassebi J Haddad FS

Aims. The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA. Patients and Methods. This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (. sd. 6.8) vs 64.1 years (. sd. 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (. sd. 2.7) vs 28.1 kg.m2 (. sd. 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications. Results. Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time (p < 0.001) and surgical team confidence levels (p < 0.001). Cumulative robotic experience did not affect accuracy of implant positioning (p = 0.52), posterior condylar offset ratio (p = 0.71), posterior tibial slope (p = 0.68), native joint line preservation (p = 0.55), and postoperative limb alignment (p = 0.65). Robotic-arm assisted UKA improved accuracy of femoral (p < 0.001) and tibial (p < 0.001) implant positioning with no additional risk of postoperative complications compared to conventional jig-based UKA. Conclusion. Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time and surgical team confidence levels but no learning curve for accuracy of implant positioning. Cite this article: Bone Joint J 2018;100-B:1033–42


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 33 - 39
1 Jul 2019
Lachiewicz PF O’Dell JA

Aims. There is insufficient evidence to recommend the use of alternative polyethylene bearings in modular, fixed-bearing total knee arthroplasty (TKA). The purpose of this study was to compare standard polyethylene (SP) and highly crosslinked polyethylene (XLP) tibial liners in posterior-stabilized TKA, with osteolysis as the primary outcome and clinical results and the rate of re-operation as the secondary outcomes. Patients and Methods. This is a single-surgeon, prospective randomized study involving one design of modular posterior-stabilized TKA. An analysis of 122 TKAs with an SP compression moulded liner and 123 with an XLP liner was performed, with a mean follow-up of six years (2 to 11). Patients were evaluated clinically using the Knee Society score, Lower Extremity Activity Score (LEAS), and the presence of an effusion, and standard radiographs were assessed for radiolucent lines and osteolytic lesions. Results. Osteolysis was present in four TKAs (3.3%) in the SP group, and no knees in the XLP group (p = 0.06). There were no significant differences between the Knee Society total score, change in total score, knee function score, change in function score, LEAS, and change in LEAS in the two groups. There was a significant difference in the presence of an effusion (10/122 with SP liners, 1/123 with XLP liners; p = 0.02). There was no significant difference in the rate of re-operation between the two groups (p = 0.36). There were no complications related to the XLP liner. Conclusion. At this length of follow-up, there were no advantages and no complications related to the use of this XLP tibial liner. The presence of effusion and small osteolytic lesions was more frequent with SP than XLP liners, but of unknown clinical significance. Cite this article: Bone Joint J 2019;101-B(7 Supple C):33–39


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 11 - 11
1 Oct 2019
Held MB Grosso MJ Gazgalis A Sarpong NO Jennings E Shah RP Cooper HJ Geller JA
Full Access

Introduction. Robotic-assisted total knee arthroplasty (TKA) was introduced to improve limb alignment, component positioning, and soft-tissue balance, yet the effect of adoption of this technology has not been established. This study was designed to evaluate whether robotic-assisted TKA leads to improved patient reported outcome measures (PROMs) and patient satisfaction as compared to conventional TKA at 3 and 12 months. Methods. This IRB-approved single-surgeon retrospective cohort analysis of prospectively collected data compared 113 conventional TKA patients with 145 imageless robotic-assisted TKA patients (Navio™ Surgical System, Smith&Nephew®, Memphis TN). Basic demographic information, intraoperative and postoperative data, and PROMs (SF-P, SF-M, WOMAC pain, WOMAC stiffness, WOMAC Physical Function, KSS) were collected and recorded preoperatively, at 3 months, and at 12 months following surgery. Range of motion (ROM), blood loss, surgical duration, and complication rates between groups were also collected. Continuous measures such as mean difference in PROMs and ROM were compared using unpaired t-tests. Categorical measures such as the percentage of patients with complications were compared using chi-square analysis. Results. There were no baseline demographic differences or preoperative PROMs between groups. Following TKA, there were no differences between groups with respect to ROM or any of the PROMs (SF-P, SF-M, WOMAC pain, WOMAC stiffness, WOMAC Physical Function, and KS scores) at 3- or 12-months. Difference between the group included larger EBL(242 vs 209 mL, p<.001) and longer surgical duration (119 vs 107minutes, p<.001) for robotic-assisted surgery. There were no differences between the two groups in total post operative complications however subgroup analysis demonstrated that the robotic assisted cohort had fewer periprosthetic joint infections (1 vs 3, p=.048) and total reoperations (1 vs 7, p=.0114). Conclusions. Imageless robotic-assisted TKA resulted in similar function and satisfaction scores when compared to conventional TKA at 3 and 12 months. While EBL and surgical duration were greater with robotic-assisted TKA, this technique resulted in fewer reoperations and periprosthetic wound infections. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1209 - 1214
1 Nov 2022
Owen AR Amundson AW Larson DR Duncan CM Smith HM Johnson RL Taunton MJ Pagnano MW Berry DJ Abdel MP

Aims

Spinal anaesthesia has seen increased use in contemporary primary total knee arthroplasties (TKAs). However, controversy exists about the benefits of spinal in comparison to general anaesthesia in primary TKAs. This study aimed to investigate the pain control, length of stay (LOS), and complications associated with spinal versus general anaesthesia in primary TKAs from a single, high-volume academic centre.

Methods

We retrospectively identified 17,690 primary TKAs (13,297 patients) from 2001 to 2016 using our institutional total joint registry, where 52% had general anaesthesia and 48% had spinal anaesthesia. Baseline characteristics were similar between cohorts with a mean age of 68 years (SD 10), 58% female (n = 7,669), and mean BMI of 32 kg/m2 (SD 7). Pain was evaluated using oral morphine equivalents (OMEs) and numerical pain rating scale (NPRS) data. Complications including 30- and 90-day readmissions were studied. Data were analyzed using an inverse probability of treatment weighted model based on propensity score that included many patient and surgical factors. Mean follow-up was seven years (2 to 18).


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 3 - 10
1 Oct 2016
Hamilton TW Pandit HG Lombardi AV Adams JB Oosthuizen CR Clavé A Dodd CAF Berend KR Murray DW

Aims. An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre. Patients and Methods. Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature. Results. The sensitivity and specificity of the Decision Aid was 92% and 88%, respectively. Excluding knees where a clear pre-operative plan was made to perform TKA, i.e. patient request, the sensitivity was 93% and specificity 96%. The false-positive rate was low (2.4%) with all affected patients readily identifiable during joint inspection at surgery. In patients meeting Decision Aid criteria and receiving UKA, the five-year survival was 99% (95% confidence intervals (CI) 97 to 100). The false negatives (3.5%), who received UKA but did not meet the criteria, had significantly worse functional outcomes (flexion p < 0.001, American Knee Society Score - Functional p < 0.001, University of California Los Angeles score p = 0.04), and lower implant survival of 93.1% (95% CI 77.6 to 100). Conclusion. The radiographic Decision Aid safely and reliably identifies appropriate patients for meniscal-bearing UKA and achieves good results in this population. The widespread use of the Decision Aid should improve the results of UKA. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):3–10


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 362 - 366
1 Mar 2010
Kennedy J Jackson MP O’Kelly P Moran R

We reviewed a single-surgeon series of 300 athletic patients who had undergone reconstruction of the anterior cruciate ligament in order to establish the relationship between the timing of the reconstruction and the incidence of meniscal and chondral pathology. The patients were divided into five groups according to the time from their injury to surgery as follows: less than two months, two to six months, six to 12 months, 12 to 18 months and more than 18 months. The presence of meniscal tears was recorded and chondral pathology was scored according to the system of the French Society of Arthroscopy. There was a significantly higher chance of a medial meniscal tear occurring in patients undergoing reconstruction after one year from their injury (odds ratio (7.99, p = 0.004). The odds of having a lateral meniscal tear did not change significantly with an increasing interval to reconstruction. The chance of patients developing degenerative changes was found to be significantly higher in the groups operated on after six months from injury (odds ratio 4.04, p = 0.005). We advocate that patients with deficiency of the anterior cruciate ligament should be counselled that there is a significant relationship between the duration of the instability of their knee and the subsequent incidence of both chondral changes and meniscal tears. In order to minimise these risks, we recommend that reconstruction be performed within the first year from injury


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1608 - 1614
1 Dec 2007
Baker PN Khaw FM Kirk LMG Esler CNA Gregg PJ

We report the long-term survival of a prospective randomised consecutive series of 501 primary knee replacements using the press-fit condylar posterior cruciate ligament-retaining prosthesis. Patients received either cemented (219 patients, 277 implants) or cementless (177 patients, 224 implants) fixation. Altogether, 44 of 501 knees (8.8%) underwent revision surgery (24 cemented vs 20 cementless). For cemented knees the 15-year survival rate was 80.7% (95% confidence interval (CI) 71.5 to 87.4) and for cementless knees it was 75.3% (95% CI 63.5 to 84.3). There was no significant difference between the two groups (cemented vs cementless; hazard ratio (HR) 0.83, 95% CI 0.45 to 1.52, p = 0.55). When comparing the covariates there was no significant difference in the rates of survival between the side of operation (HR 0.58, p = 0.07), age (HR 0.97, p = 0.10) and diagnosis (HR 1.25 p = 0.72). However, there was a significant gender difference, with males having a higher failure rate with cemented fixation (HR 2.48, p = 0.004). Females had a similar failure rate in both groups. This single-surgeon series, with no loss to follow-up, provides reliable data of the revision rates of one of the most commonly-used total knee replacements. The survival of the press-fit condylar total knee replacement remained good at 15 years, irrespective of the method of fixation


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims

A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation.

Methods

This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 442 - 448
1 Apr 2020
Kayani B Konan S Ahmed SS Chang JS Ayuob A Haddad FS

Aims

The objectives of this study were to assess the effect of anterior cruciate ligament (ACL) resection on flexion-extension gaps, mediolateral soft tissue laxity, maximum knee extension, and limb alignment during primary total knee arthroplasty (TKA).

Methods

This prospective study included 140 patients with symptomatic knee osteoarthritis undergoing primary robotic-arm assisted TKA. All operative procedures were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess study outcomes pre- and post-ACL resection with knee extension and 90° knee flexion. This study included 76 males (54.3%) and 64 females (45.7%) with a mean age of 64.1 years (SD 6.8) at time of surgery. Mean preoperative hip-knee-ankle deformity was 6.1° varus (SD 4.6° varus).


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 647 - 652
1 May 2017
Abdel MP Ledford CK Kobic A Taunton MJ Hanssen AD

Aims

The number of revision total knee arthroplasties (TKA) that are performed is expected to increase. However, previous reports of the causes of failure after TKA are limited in that they report the causes at specific institutions, which are often dependent on referral patterns. Our aim was to report the most common indications for re-operations and revisions in a large series of posterior-stabilised TKAs undertaken at a single institution, excluding referrals from elsewhere, which may bias the causes of failure.

Patients and Methods

A total of 5098 TKAs which were undertaken between 2000 and 2012 were included in the study. Re-operations, revisions with modular component exchange, and revisions with non-modular component replacement or removal were identified from the medical records. The mean follow-up was five years (two to 12).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1517 - 1521
1 Nov 2012
Niinimäki TT Eskelinen A Mann BS Junnila M Ohtonen P Leppilahti J

Previous studies from single centres or single-surgeon series report good early and mid-term results for high tibial osteotomy (HTO) in the treatment of osteoarthritis of the knee. However, the survivorship of HTO at a national level is unknown. This registry-based study included 3195 high HTOs performed between 1987 and 2008. Kaplan-Meier analysis revealed an overall survivorship of 89% (95% confidence interval (CI) 88 to 90) at five years and 73% (95% CI 72 to 75) at ten years, when conversion to total knee replacement was taken as the endpoint. Females and patients aged > 50 years had worse survivorship than males or patients aged ≤ 50 years (hazard ratio (HR) 1.26 (95% CI 1.11 to 1.43) and HR 1.41 (95% CI 1.23 to 1.64), respectively). The survivorship of HTOs performed between 1998 to 2008 was worse than for those performed between 1987 and 1997.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1067 - 1070
1 Aug 2012
Melton JTK Mayahi R Baxter SE Facek M Glezos C

A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one.

Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised.

These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1096 - 1099
1 Aug 2010
Sutherland AG Cooper K Alexander LA Nicol M Smith FW Scotland TR

We identified a series of 128 patients who had unilateral open reconstruction of the anterior cruciate ligament (ACL) by a single surgeon between 1993 and 2000. In all, 79 patients were reviewed clinically and radiologically eight to 15 years after surgery. Assessment included measurement of the Lysholm and Tegner scores, the ACL quality-of-life score and the Short Form-12 score, as well as the International Knee Documentation Committee clinical assessment, measurement of laxity by the KT-1000 arthrometer, a single-leg hop test and standardised radiography of both knees using the uninjured knee as a control.

Of the injured knees, 46 (57%) had definite radiological evidence of osteoarthritis (Kellgren-Lawrence grade 2 or 3), with a mean difference between the injured and non-injured knees of 1.2 grades. The median ACL quality-of-life score was 80 (interquartile range (IQR) 60 to 90), the Lysholm score 84 (IQR 74 to 95), the Short Form-12 physical component score 54 (IQR 49 to 56) and the mean Hop Index 0.94 (0.52 to 1.52). In total 58 patients were graded as normal, 20 as nearly normal and one as abnormal on the KT-1000 assessment and pivot-shift testing. Taking the worst-case scenario of assuming all non-attenders (n = 48), two septic failures and one identified unstable knee found at review to be failures, the failure rate was 40%. Only two of the patients reviewed stated that they would not have similar surgery again.

Open reconstruction of the ACL gives good, durable functional results, but with a high rate of radiologically evident osteoarthritis.