Advertisement for orthosearch.org.uk
Results 1 - 20 of 95
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims. Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE. Methods. This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates. Results. Compared with non-stiff aTSAs, stiff aTSAs had poorer passive FE and active external rotation (ER), whereas there were no significant postoperative differences between stiff rTSAs and non-stiff rTSAs. There were no significant differences in preoperative function when comparing stiff aTSAs with stiff rTSAs. However, stiff rTSAs had significantly greater postoperative active and passive FE (p = 0.001 and 0.004, respectively), and active abduction (p = 0.001) compared with stiff aTSAs. The outcome scores were significantly more favourable in stiff rTSAs for the Shoulder Pain and Disability Index, Simple Shoulder Test, American Shoulder and Elbow Surgeons score, University of California, Los Angeles score, and the Constant score, compared with stiff aTSAs. When comparing the proportion of stiff aTSAs versus stiff rTSAs that exceeded the minimal clinically important difference and substantial clinical benefit, stiff rTSAs achieved both at greater rates for all measurements except active ER. The complication rate did not significantly differ between stiff aTSAs and stiff rTSAs, but there was a significantly higher rate of revision surgery in stiff aTSAs (p = 0.007). Conclusion. Postoperative overhead ROM, outcome scores, and rates of revision surgery favour the use of a rTSA rather than aTSA in patients with glenohumeral OA, an intact rotator cuff and limited FE, with similar rotational ROM in these two groups. Cite this article: Bone Joint J 2023;105-B(12):1303–1313


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 33 - 33
1 Dec 2022
Chen H Pike J Huang A
Full Access

The purpose of this prospective pilot study is to examine the feasibility of a physiotherapist led rapid access shoulder screening clinic (RASC). The goal of this study is to assess for improvements in patient access to care, patient reported outcome measures, patient reported experience measures, and cost outcomes using time driven activity based costing methods. Patient recruitment began in January 2021. Consultation requests from general practitioners and emergency rooms are analyzed and triaged through a central system. One half of patients awaiting consultation were triaged to the traditional route used at our center while the other half were triaged to be assessed at the RASC. Outcome measures consisting of the Simple Shoulder Test and SF-12 were recorded at the initial consultation and at follow up appointments. Cost benefit analysis was conducted using time driven activity based costing methods (TD-ABC). From January to August of 2021, 123 new patients were triaged for RASC assessment. On average, the RASC gets 10 new referrals per month. As of September 2021, there are 65 patients still on waitlist for RASC assessment with 58 having been assessed. Of the 58, 11% were discharged through the RASC, 48% pursued private physiotherapy, 14% had injections, 19% proceeded on for surgical consultation, and 8% did not show. Over time same time period, approximately 15 new patients were seen in consultation by the surgeon's office. Thirty-five responses were obtained from RASC patients during their initial intake assessment. The average age of respondents was 54.7 with 21 females and 14 males. Median SF-12 scores in the physical dimension (PCS-12) for RASC patients were 36.82 and mental (MCS-12) 49.38927. Median Simple Shoulder Test scores measured 6. Of the patients who responded to the follow up questionnaires after completing physiotherapy at the RASC, both the SF-12 and Simple Shoulder Test scoring improved. Median PCS-12 measured 47.08, MCS-12 of 55.87, and Simple Shoulder Test measured 8. RASC assessments by PT saved $172.91 per hour for consultation and $157.97 per hour for patient follow ups. Utilization of a physiotherapy led rapid access shoulder clinic resulted in improvements in patient outcomes as measured by the SF-12 and Simple Shoulder Test as well as significant direct cost savings. Proper triage protocols to identify which patients would be suitable for RASC assessment, buy-in from physiotherapists, and timely assessment of patients for early initiation of rehabilitation for shoulder pain is paramount to the success of a RASC system at our centre. Future research direction would be geared to analyzing a larger dataset as it becomes available


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims. We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients. Methods. A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up. Results. We included 428 primary aTSAs with a mean follow-up of 2.4 years (SD 0.6). Our cohort consisted of 251 non-smokers, 138 former smokers who quit a mean 21 years (SD 14) prior to surgery (25 pack-years (SD 22)), and 39 current smokers (23 pack-years (SD 20)). At two- to four-year follow-up, former smokers had less favourable SPADI, SST, and FE strength compared to non-smokers, and current smokers had less favourable SPADI, SST, ASES score, UCLA score, Constant-Murley score, FE, abduction, and ER strength compared to non-smokers. Non-smokers exhibited higher revision-free survival rates at two, five, eight, and ten years postoperatively compared to former smokers and current smokers, who had similar rates. Conclusion. Our study suggests that smoking has a negative effect on aTSA functional outcomes that may persist even after quitting. Cite this article: Bone Joint J 2024;106-B(11):1263–1272


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims. The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula. Methods. We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification. Results. The ten-year disease-specific survival was 76%. High tumour grade (hazard ratio (HR) 4.27; p = 0.016) and a total resection of the scapula (HR 3.84; p = 0.015) were associated with worse survival. The ten-year metastasis-free and local recurrence-free survivals were 82% and 86%, respectively. Total scapular resection (HR 6.29; p = 0.004) was associated with metastatic disease and positive margins were associated with local recurrence (HR 12.86; p = 0.001). At final follow-up, the mean shoulder forward elevation and external rotation were 79° (SD 62°) and 27° (SD 25°), respectively. The most recent functional outcomes evaluated included the mean Musculoskeletal Tumor Society Score (76% (SD 17%)), the American Shoulder and Elbow Score (73% (SD 20%)), and the Simple Shoulder Test (7 (SD 3)). Preservation of the glenoid (p = 0.001) and scapular spine (p < 0.001) improved clinical outcomes; interestingly, preservation of the scapular spine without the glenoid improved outcomes (p < 0.001) compared to preservation of the glenoid alone (p = 0.05). Conclusion. Resection of the scapula is a major undertaking with an oncological outcome related to tumour grade, and a functional outcome associated with the status of the scapular spine and glenoid. Positive resection margins are associated with local recurrence. Cite this article: Bone Joint J 2023;105-B(12):1314–1320


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 34 - 34
10 May 2024
Penumarthy R Turner P
Full Access

Aim. Clavicular osteotomy was described as an adjunct to deltopectoral approach for improved exposure of the glenohumeral joint. This study aims to present contemporary outcomes and complications associated with the routine use of clavicular osteotomy by a single surgeon in a regional setting within New Zealand. Methods. A retrospective case series of patients who have undergone any shoulder arthroplasty for any indication between March 2017 to August 2022. This time period includes all patients who had clavicular osteotomy(OS) and patients over an equal time period prior to the routine use of osteotomy as a reference group (N-OS). Oxford Shoulder Score (OSS) and a Simple Shoulder Test (STT) were used to assess functional outcomes and were compared with the reported literature. Operative times and Complications were reviewed. Results. 66 patients were included in the study. 33 patients in the OS group and 33 in the N-OS group. No difference in age, sex, indications for operative intervention and the surgery provided was identified. No significant difference in operative time between groups (N-OS 121 minutes; OS 128 minutes). No clinically significant difference was identified in the OSS (N-OS; mean 38 vs OS 39) or the STT (N-OS 8.3 vs OS 9). The outcomes scores of both groups are in keeping with published literature. Two post operative clavicle fractures, one prominent surgical knot occurred in the OS that required further surgical intervention. Two cases of localized pain over the clavicle and one case of the prominent lateral clavicle were reported in the OS group. Two cases of localized pain over clavicle reported in the N-OS group. Conclusion. Use of clavicular osteotomy is not associated with inferior patient reported. The osteotomy introduces specific risks, however, the study provides evidence that these complications are infrequent and avoidable. Surgeons should feel confident in using this adjunct when exposure to the shoulder is difficult


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 573 - 573
1 Oct 2010
Lorbach O Anagnostakos K Kohn D Pape D Scherf C
Full Access

Background: Comparison of intra-articular corticoid injections and oral corticosteroids in the treatment of adhesive capsulitis of the shoulder. Methods: In a prospective randomized evaluation two different treatment regimen were compared. 40 patients with idiopathic adhesive capsulitis of the shoulder were treated either with an oral (20) corticoid treatment regimen for 4 weeks or intra-articular (20) injection series of corticosteroids (3 injections- 4, 8, 12 weeks).Patient groups were comparable in sex, age and affected side. Follow-up periods were after 4,8,12 weeks, 6 and 12 months. For the clinical evaluation the Constant and Murley Score, the Simple Shoulder Test and visual analog scales for pain, function and satisfaction were used. Results: In the patients group treated with oral glucocorticoids significant improvements were found for the Constant and Murley Score (p< .0001), the Simple Shoulder Test (p=.035) and range of motion for flexion (p< .0001), abduction (p< .0001), external (p=.001) and internal rotation (p=.028) already at 4 weeks follow-up. The visual analog scales for pain, function and patient satisfaction also improved significantly after 4 weeks of treatment (p< .0001).). The patient group treated with an intra-articular glucocorticoid injection series also showed significant improvements for the Constant and Murley Score (p< .0001), the Simple Shoulder Test (p< .0001) and the visual analog scales for pain, function and patient satisfaction (p< .0001) after 4 weeks and also at any other follow up. Significant improvements were also seen in abduction (p< .0001), flexion (p< .0001) and external rotation (p=.001) and internal rotation (p=.035) after 4 weeks of treatment. These results were confirmed at any other follow up. Comparison of the two treatment regimen showed superior short term results for the intra-articular treatment regimen in range of motion, Constant Score and Simple Shoulder Test and patient satisfaction (p< .05). No significant differences were found in the visual analog scales for pain and function (p> .05). Conclusion: The use of cortisone in the treatment of idiopathic adhesive capsulitis of the shoulder leads to fast pain relief and improves range of motion. Intra-articular injections of glucocorticoids showed superior short term results in objective shoulder scores, range of motion and patient satisfaction compared with a short course of oral corticosteroids


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims. Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA. Patients and Methods. We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10). Results. Six patients (22%) developed complications requiring further revision surgery, at a mean of 1.7 years (0.1 to 5.3) postoperatively. The indication for further revision was dislocation in two, glenoid loosening in one, fracture of the humeral component in one, disassociation of the glenosphere in one, and infection in one. The five-year survival free of further revision was 85%. Five additional RSAs developed complications that did not need surgery, including dislocation in three and periprosthetic fracture in two. Overall, patients who did not require further revision had excellent pain relief, and significant improvements in elevation and external rotation of the shoulder (p < 0.01). The mean postoperative American Shoulder and Elbow Surgeons (ASES), and simple shoulder test (SST) scores were 66 and 7, respectively. Radiological results were available in 26 patients (96.3%) at a mean of 4.3 years (1.5 to 9.5). At the most recent follow-up, six patients (23%) had glenoid lucency, which were classified as grade III or higher in three (12%). Smokers had a significantly increased risk of glenoid lucency (p < 0.01). Conclusion. Revision RSA, when used to salvage a failed primary RSA, can be a successful procedure. At intermediate follow-up, survival rates are reasonable, but dislocation and glenoid lucency remain a concern, particularly in smokers. Cite this article: Bone Joint J 2018;100-B:1493–98


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 174 - 174
1 Sep 2012
Katthagen JC Voigt C Jensen G Lill H
Full Access

Implant removal is necessary in up to 25% of patients with plate osteosynthesis after proximal humeral fracture. Our new technique of arthroscopic implant removal offers all advantages of minimal invasive surgery. Additionally treatment of concomitant intraarticular lesions is possible. This study outlines the first results after arthroscopic implant removal in comparison with those of open implant removal. A prospective series of 40 consecutive treated patients had implant removal and arthrolysis after plate osteosynthesis of proximal humeral fracture. Implant removal was carried out due to limitation in range of movement, secondary implant dislocation and implant impingement. 30 patients (median age 63 (30–82) years) had arthroscopic, ten patients (median age 53 (34–76) years) had open implant removal. Median 10 months after implant removal subjective patient satisfaction, Constant Murley Score (CMS) and Simple Shoulder Test were determined. Arthroscopic implant removal showed comparable first results as open implant removal. There was no significant difference between CMS of both groups. The active shoulder abduction, flexion and external rotation improved significantly after arthroscopic and open implant removal. The simple shoulder test outlined advantages for the arthroscopic technique. After arthroscopic implant removal patients showed higher subjective satisfaction as well as faster pain reduction and mobilization. Analysis of perioperative data showed less blood loss in the group with arthroscopic implant removal. In 85% of patients with arthroscopic implant removal concomitant intraarticular lesions were observed and treated. The arthroscopic implant removal after plate osteosynthesis of proximal humeral fractures offers all advantages of minimal invasive surgery and comparable first results as the open implant removal. The subjective and objective satisfaction of patients is high. The technique can be applied and established by all arthroscopic trained shoulder surgeons


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 74 - 74
1 Feb 2020
DeVito P Damodar D Berglund D Vakharia R Moeller E Giveans M Horn B Malarkey A Levy J
Full Access

Background. The purpose of this study was to determine if thresholds regarding the percentage of maximal improvement in the Simple Shoulder Test (SST) and American Shoulder and Elbow Surgery (ASES) score exist that predict “excellent” patient s­atisfaction (PS) following reverse total shoulder arthroplasty (RSA). Methods. Patients undergoing RSA using a single implant system were evaluated pre-operatively and at a minimum 2-year follow-up. Receiver-operating-characteristic (ROC) curve analysis determined thresholds to predict “excellent” PS by evaluating the percentage of maximal improvement for SST and ASES. Pre-operative factors were analyzed as independent predictors for achieving SST and ASES thresholds. Results. 198 (SST) and 196 (ASES) patients met inclusion criteria. For SST and ASES, ROC analysis identified 61.3% (p<.001) and 68.2% (p<.001) maximal improvement as the threshold for maximal predictability of “excellent” satisfaction respectively. Significant positive correlation between the percentage of maximum score achieved and “excellent” PS for both groups were found (r=.440, p<.001 for SST score; r=0.417, p<.001 for ASES score). Surgery on the dominant hand, greater baseline VAS Pain, and cuff arthropathy were independent predictors for achieving the SST and ASES threshold. Conclusion. Achievement of 61.3% of maximal SST score improvement and 68.3% of maximal ASES score improvement represent thresholds for the achievement of “excellent” satisfaction following RSA. Independent predictors of achieving these thresholds were dominant sided surgery and higher baseline pain VAS scores for SST, and rotator cuff arthropathy for ASES. Keywords. Percentage of maximal improvement; Predictors; American Shoulder and Elbow Surgery Score; Simply Shoulder Test; Reverse shoulder Arthroplasty; Satisfaction. Level of Evidence. Level III


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 504 - 510
1 Apr 2009
Henkus HE de Witte PB Nelissen RGHH Brand R van Arkel ERA

In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of acromion was classified according to Bigliani. Patients were assessed at follow-up using the Constant score, the simple shoulder test and visual analogue scores for pain and functional impairment. One patient was lost to follow-up. At a mean follow-up of 2.5 years (1 to 5) both bursectomy and acromioplasty gave good clinical results. No statistically significant differences were found between the two treatments. The type of acromion and severity of symptoms had a greater influence on the clinical outcome than the type of treatment. As a result, we believe that primary subacromial impingement syndrome is largely an intrinsic degenerative condition rather than an extrinsic mechanical disorder


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 576 - 576
1 Oct 2010
Verhelst L Berghs B Liekens K Schepens A Vandekerckhove P Vanhoonacker P
Full Access

Study design: Retrospective study of 34 patients with a massive rotator cuff tear, who were treated with an arthroscopic tuberoplasty, debridement of the degenerate cuff and biceps tenotomy. Objectives: To evaluate the clinical outcome of a reversed decompression at the medium term follow up. Summary of background data: Rotator cuff repair can become impossible for massive tears in the elderly. If conservative management fails, a reverse total shoulder arthroplasty (RSA) is commonly used. However, Fenlin described in 2002 a tuberoplasty for this pathology and reported good to excellent results. This procedure appears to be well tolerated as it is arthroscopic, not time consuming and not depending on intensive physiotherapy. In case of failure, a primary RSA is still possible. Methods: 36 patients treated with a tuberoplasty between February 2002 and September 2006 were identified. One patient deceased, one patient developed Alzheimer dementia, leaving 34 patients available for follow-up. They completed the SF-36 questionnaire and the Simple shoulder test. They were clinically reviewed and scored with the Constant-Murley score. All 34 had complete radiographic work-up (x-ray; ultrasound) preoperatively and at final follow up. Results: Median age at operation was 71 years (range: 52,5 – 82,16). Mean follow-up was 3,1 years (SD: +/− 0,75). Mean operating time was 35 minutes (SD: +/− 12.33). There were no surgical complications. Postoperatively, there was an uneventful recovery in all patients. At final follow-up, two patients were revised to a RSA. One patient was revised after 9 months because of continuous pain and loss of function. The second patient developed a complete osteonecrosis and was revised after one year. The 32 remaining patients had a preoperative Constant-Murley score adjusted for age and gender of 34,8. This improved to an average of 84 at final follow up. The simple shoulder test improved from an average of 1,8 to 8,4. The average decrease of subacromial space was 2,34 mm and the loss of glenohumeral joint space was 0,57. Finally, the preoperative grade of arthrosis was 0,46 compared to a postoperative average of 1,1. At final follow-up, 85% (27/32) were either satisfied or very satisfied with the result. 12,5% (4/32) appreciated the result as only fair. 2,5% (1/32) was dissatisfied, but didn’t consider revision surgery. Conclusion: We conclude that a tuberoplasty with rotator cuff debridement and biceps tenotomy is a reliable treatment for massive rotator cuff tears in the elderly at medium follow up. In case of failure, revision to RSA is still a valuable option


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154). Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications. We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 51 - 52
1 Mar 2008
Sahajpal D Drosdowech D Macdermid J Patterson S Faber K
Full Access

This study prospectively evaluated the functional outcome and strength of patients after rotator cuff surgery. Thirty-three patients were evaluated pre-operatively and post-operatively for one year. Each patient underwent clinical evaluation of shoulder range of motion and machine strength testing. Additionally they completed the SF-36, DASH, Western Ontario Rotator Cuff, and Washington Simple Shoulder Test questionnaires. The study showed that patients with small and large tears showed improvement after surgery. Smaller tears had better outcomes. Workplace Safety and Insurance Board (WSIB) patients had lower functional outcomes despite strength and range of motion showing no difference with non- WSIB patients. This study prospectively evaluated strength and functional outcome after rotator cuff surgery. Thirty-three patients, mean age 55.6, were evaluated pre-operatively and post-operatively for one year. Twenty-eight patients were male and five were female. Seventeen patients involved the Workplace Safety and Insurance Board and sixteen patients had non-WSIB related tears. The patients were also divided based on tear size into two groups (< 3cm and > 3.1cm). Allpatients underwent an acromioplasty. Twenty-two also had an open or mini-open repair. Two underwent arthroscopic repair. Five patients had a debridement and four patients had Latissimus Dorsi Transfer. All had an evaluation of range of motion(ROM), machine isometric strength testing, and completion of the SF-36, DASH, Western Ontario Rotator Cuff (WORC) and Washington Simple Shoulder Test (WST) at each visit. Based on tear size, there was a significant difference in functional outcome on the SF-36 (p< 0.05), DASH (p< 0. 005), WORC (p< 0.001) and WST (p< 0.01). Within each group there was significant improvement in strength (p< 0.01) over time. The smaller tear group showed significantly greater strength. The ROM was improved within each group over time (p< 0.01), though no statistical difference was determined between groups. In comparing the sample based on WSIB status, functional outcomes were better in Non-WSIB patients (p< 0.01). Although no statistical difference in strength and ROM was noted. Patients with both small and large tears showed improved functional outcome, strength and ROM over time, with the smaller tear group having better outcomes. WSIB patients had lower functional outcomes despite strength and ROM showing no difference between the two groups


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 138 - 138
1 Jul 2020
Bois A Knight P Alhojailan K Bohsali K Wirth M
Full Access

A reverse total shoulder arthroplasty (RSA) is frequently performed in the revision setting. The purpose of this study was to report the clinical outcomes and complication rates following revision RSA (RRSA) stratified according to the primary shoulder procedure undergoing revision, including failed hemiarthroplasty (HA), anatomic total shoulder arthroplasty (TSA), RSA, soft tissue repair (i.e., rotator cuff repair), and open reduction internal fixation (ORIF). A systematic review of the literature was performed using four databases (EMBASE, Medline, SportDISCUS, and Cochrane Controlled Trials Register) between January 1985 and September 2017. The primary outcomes of interest included active range-of-motion (ROM), pain, and functional outcome measures including the American Shoulder and Elbow Surgeons Score (ASES), Simple Shoulder Test (SST), and Constant-Murley (CS) Score. Secondary outcomes included complication rates, such as infection, dislocation, perioperative fracture, base plate failure, neurovascular injury, soft tissue injury, and radiological evidence of scapular notching. Clinical outcome data was assessed for differences between preoperative and postoperative results and complication results were reported as pooled complication rates. Forty-five studies met the inclusion criteria for analysis, which included 1,016 shoulder arthroplasties with a mean follow-up of 45.2 months (range, 31.1 to 57.2 months) (Fig. 1). The mean patient age at revision was 60.2 years (range, 36 to 65.2 years). Overall, RSA as a revision procedure for failed HA revealed favorable outcomes with respect to forward elevation (FE), CS pain, ASES, SST, and CS outcome assessment scores, with mean improvements of 52.5° ± 21.8° (P = < 0 .001), 6.41 ± 4.01 SD (P = 0.031), 20.1 ± 21.5 (P = 0.02), 5.2 ± 8.7 (P = 0.008), and 30.7 ± 9.4 (P = < 0 .001), respectively. RSA performed as a revision procedure for failed TSA demonstrated an improvement in the CS outcome score (33.8 ± 12.4, P = 0.016). RSA performed as a revision procedure for failed soft tissue repair demonstrated significant improvements in FE (60.2° ± 21.2°, P = 0.031) and external rotation (20.8° ± 18°, P = 0.016), respectively. Lastly, RSA performed as a revision procedure for failed ORIF revealed favorable outcomes in FE (61° ± 20.2°, P = 0.031). There were no significant differences noted in RSA performed as a revision procedure for failed RSA, or when performed for a failed TSA, soft tissue repair, and ORIF in any other outcome of interest. Pooled complication rates were found to be highest in failed RSA (10.9%), followed by soft tissue repair (7.1%), HA (6.8%), TSA (5.4%) and ORIF (4.7%). When compared to other revision indications, RRSA for failed HA demonstrated the most favorable outcomes, with significant improvements in ROM, pain, and in several outcome assessments. Complication rates were determined and stratified as per the index procedure undergoing RRSA, patients undergoing revision of a failed RSA were found to have the highest complication rates. With this additional information, orthopaedic surgeons will be better equipped to provide preoperative education regarding the risks, benefits and complication rates to those patients undergoing a RRSA. For any figures or tables, please contact authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1184 - 1187
1 Sep 2007
Rispoli DM Sperling JW Athwal GS Schleck CD Cofield RH

We have examined the relief from pain and the functional outcome in 18 patients who underwent resection arthroplasty of the shoulder as a salvage operation between 1988 and 2002. The indications included failed shoulder replacement in 17, with infection in 13, and chronic septic arthritis in one. The mean follow-up was 8.3 years (2.5 to 16.6). Two intra-operative fractures of the humerus occurred, both of which healed. The level of pain was significantly decreased (t-test, p < 0.001) but five patients continued to have moderate to severe pain. The mean active elevation was 70° (0° to 150°) postoperatively and represented an improvement from 39° (0° to 140°) (t-test, p = 0.003), but internal and external rotation were hardly changed. The mean number of positive answers on the 12-question Simple Shoulder Test was 3.1 (0 to 12) but the shoulder was generally comfortable when the arm was positioned at rest by the side. The mean post-operative American Shoulder and Elbow Surgeon’s score was 36 (8 to 73). Despite applying this procedure principally to failed shoulder replacements, the results were similar to those reported in the literature for patients after severe fracture-dislocation. Reduction of pain is possible in one half to two-thirds of patients. The outcome of this operation in providing relief from pain cannot be guaranteed, but the shoulder is usually comfortable at rest, albeit with profound functional limitations


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1088 - 1092
1 Aug 2011
Lizaur A Sanz-Reig J Gonzalez-Parreño S

The purpose of this study was to review the long-term outcomes of a previously reported prospective series of 46 type III acromioclavicular dislocations. These were treated surgically with temporary fixation of the acromioclavicular joint with wires, repair of the acromioclavicular ligaments, and overlapped suture of the deltoid and trapezius muscles. Of the 46 patients, one had died, four could not be traced, and three declined to return for follow-up, leaving 38 patients in the study. There were 36 men and two women, with a mean age at follow-up of 57.3 years (41 to 71). The mean follow-up was 24.2 years (21 to 26). Patients were evaluated using the Imatani and University of California, Los Angeles (UCLA) scoring systems. Their subjective status was assessed using the Disabilities of the Arm, Shoulder and Hand and Simple Shoulder Test questionnaires, and a visual analogue scale for patient satisfaction. The examination included radiographs of the shoulder. At a follow-up of 21 years, the results were satisfactory in 35 (92.1%) patients and unsatisfactory in three (7.9%). In total, 35 patients (92.1%) reported no pain, one slight pain, and two moderate pain. All except two patients had a full range of shoulder movement compared with the opposite side. Unsatisfactory results were the result of early redisplacement in two patients, and osteoarthritis without redisplacement in one. According to the Imatani and UCLA scores, there was no difference between the operated shoulder and the opposite shoulder (p > 0.05). Given the same situation, 35 (92.1%) patients would opt for the same surgical treatment again. Operative treatment of type III acromioclavicular joint injuries produces satisfactory long-term results


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 19 - 19
1 Apr 2018
Martens S Lipperts M Samijo S Walbeehm R Grimm B
Full Access

Background. Shoulder pain limits range of motion (ROM) and reduces performing activities of daily living (ADL). Objective assessment of shoulder function could be of interest for diagnosing shoulder pathology or functional assessment of the shoulder after therapy. The feasibility of 2 wearable inertial sensors for functional assessment to differentiate between healthy subjects and patients with unilateral shoulder pathology is investigated using parameters as asymmetry. Methods. 75 subjects were recruited into this study and were measured for at least 8 h a day with the human activity monitor (HAM) sensor. In addition, patients completed the Disability of the Arm, Should and Hand (DASH) score and the Simple Shoulder Test (SST) score. From 39 patients with a variety of shoulder pathologies 24 (Age: 53.3 ± 10.5;% male: 62.5%) complete datasets were successfully collected. From the 36 age-matched healthy controls 28 (Age: 54.9 ± 5.8;% male = 57.1%) full datasets could be retrieved. Activity parameters were obtained using a self-developed algorithm (Matlab). Outcome parameters were gyroscope and accelerometry-based relative and absolute asymmetry scores (affected/unaffected; dominant/non-dominant) of movement intensity. Results & Discussion. The absolute and relative asymmetry scores of the accelerometry-based intensity results for a threshold of > 0.1 g (AUC 0.821 and AUC 0.827) proved to be slightly more distinctive to the gyroscope-based intensity results for a threshold of > 10 deg/s (AUC 0.807 and 0.795) to distinguish between the healthy group and the shoulder group. Asymmetry (< 1%) was nearly absent in healthy controls (5/56 subjects) using the accelerometry-based intensity (> 0.1g) results but common in patients (29/48 subjects). A moderate, significant correlation was found between the asymmetry scores and the DASH score, thus complementary use is advised. The asymmetry scores had no correlation to the SST score. Conclusion. Ambulant assessment of shoulder activity using human activity monitors, containing a gyroscope and accelerometer, during ADL is feasible. The accelerometry-based and gyroscope-based absolute and relative asymmetry scores are promising parameters to diagnose or assess function of the shoulder. A moderate correlation was found between the DASH score and the activity monitor parameters, suggesting both could be used complementary to assess function


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 466 - 466
1 Nov 2011
Koerver R Heyligers I Samijo S Grimm B
Full Access

Introduction: In clinical orthopaedics questionnaire based outcome scores such as the DASH shoulder score suffer from a ceiling effect, subjectivity and the dominance of pain perception over functional capacity. As a result it has becomes increasingly difficult to clinically validate medical innovations in therapy or implants and to account for rising patient demands. Thus, objective functional information needs to be added to routine clinical assessment. Motion analysis with opto-electronic systems, force plates or EMG is a powerful research tool but lab-based, too expensive and time consuming for routine clinical use. Inertia sensor based motion analysis (IMA) can produce objective motion parameters while being faster, cheaper and easier to operate. In this study a simple IMA shoulder test is defined and. its reliability tested,. its diagnostic power to distinguish healthy from pathological shoulders is measured and. it is validated against gold standard clinical scores. Methods: An inertia sensor (41x63x24mm3, 39g) comprising a triaxial accelerometer (±5g) and a triaxial gyroscope (±300°/sec) was taped onto the humerus in a standardised position. One-hundred healthy subjects without shoulder complaints (40.6 ±15.7yrs) and 40 patients (55.4 ±12.7yrs) with confirmed unilateral shoulder pathology (29 subacromial impingement, 9 rotator cuff pathology, 2 other) were measured. Two motion tasks (‘hand behind the head’ and ‘hand to the back’) based on the Simple Shoulder Test (SST) were performed on both shoulders (three repetitions at self selected speed). Motion parameters were calculated as the surface area described by combing two angular rate signals of independent axes (ARS) or by combing the angular rate and the acceleration of a single axis (COMP score). The relative asymmetry between two sides was scored. Results: The test produced high intra-(r2≥0.88) and inter-observer reliability (r2≥0.82). Healthy subjects scored a mean asymmetry of 9.6% (ARS) and 14.6% (Comp). Patients with shoulder complaints showed > 3× higher asymmetry (ARS: 34.1%, Comp: 42.7%) than the healthy controls (p< 0.01). Using thresholds (ARS: 16%, Comp 27%) healthy and pathological subjects could be distinguished with high diagnostic sensitivity (e.g. ARS: 97.5% [CI: 85.3–99.9%]) and specificity (e.g. COMP: 85.5% [CI: 76.1–91.1%]). Both asymmetry scores were strongly intercorrelated (r2=0.76) as were the clinical scores (r2=0.62, DASH-SST). Asymmetry and clinical scores were hardly correlated (r2< 0.14). Discussion: The IMA shoulder test and asymmetry scores showed high reliability meeting or exceeding common clinical scores. With a fast assessment of a simple ADL tasks (test duration < 60s) it was possible to provide diagnostic power at clinically usable level making routine clinical application feasible even by nonspecialist personnel. Weak correlations with the clinical scores show that the new test adds an objective functional dimension to outcome assessment which may have the potential to differentiate new treatments or implants required to trigger new therapeutic innovation cycles. Similar motion tests and parameters could also serve lower extremity outcome assessment


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 967 - 972
1 Jul 2015
Hussey MM Hussey SE Mighell MA

Failed internal fixation of a fracture of the proximal humerus produces many challenges with limited surgical options. The aim of this study was to evaluate the clinical outcomes after the use of a reverse shoulder arthroplasty under these circumstances. Between 2007 and 2012, 19 patients (15 women and four men, mean age 66 years; 52 to 82) with failed internal fixation after a proximal humeral fracture, underwent implant removal and reverse shoulder arthroplasty (RSA). The mean follow-up was 36 months (25 to 60). The mean American Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019). The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p = 0.020), and the mean visual analogue scale for pain improved from 6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7° to 101.1° (p < 0.001), mean abduction from 58.7° to 89.1° (p = 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043) and mean internal rotation from buttocks to L4 (p = 0.034). A major complication was recorded in five patients (26%) (one intra-operative fracture, loosening of the humeral component in two and two peri-prosthetic fractures). A total of 15 patients (79%) rated their outcome as excellent or good, one (5%) as satisfactory, and three (16%) as unsatisfactory. . An improvement in outcomes and pain can be expected when performing a RSA as a salvage procedure after failed internal fixation of a fracture of the proximal humerus. Patients should be cautioned about the possibility for major complications following this technically demanding procedure. Cite this article: Bone Joint J 2015;97-B:967–72