Advertisement for orthosearch.org.uk
Results 1 - 20 of 1846
Results per page:
Bone & Joint Research
Vol. 13, Issue 8 | Pages 372 - 382
1 Aug 2024
Luger M Böhler C Puchner SE Apprich S Staats K Windhager R Sigmund IK

Aims. Serum inflammatory parameters are widely used to aid in diagnosing a periprosthetic joint infection (PJI). Due to their limited performances in the literature, novel and more accurate biomarkers are needed. Serum albumin-to-globulin ratio (AGR) and serum CRP-to-albumin ratio (CAR) have previously been proposed as potential new parameters, but results were mixed. The aim of this study was to assess the diagnostic accuracy of AGR and CAR in diagnosing PJI and to compare them to the established and widely used marker CRP. Methods. From 2015 to 2022, a consecutive series of 275 cases of revision total hip (n = 129) and knee arthroplasty (n = 146) were included in this retrospective cohort study. Based on the 2021 European Bone and Joint Infection Society (EBJIS) definition, 144 arthroplasties were classified as septic. Using receiver operating characteristic curve (ROC) analysis, the ideal thresholds and diagnostic performances were calculated. The areas under the curve (AUCs) were compared using the z-test. Results. AGR, CAR, and CRP were associated with PJI (p < 0.001). Sensitivities were 62.5% (95% CI 54.3 to 70.0), 73.6% (95% CI 65.8 to 80.1), and 71.5% (95% CI 63.6 to 78.3), respectively. Specificities were calculated with 84.7% (95% CI 77.5 to 89.9), 86.3% (95% CI 79.2 to 91.2), and 87.8% (95% CI 80.9 to 92.4), respectively. The AUC of CRP (0.797 (95% CI 0.750 to 0.843)) was significantly higher than the AUC of AGR (0.736 (95% CI 0.686 to 0.786), p < 0.001), and similar to AUC of CAR (0.799 (95% CI 0.753 to 0.846), p = 0.832). Decreased sensitivities were observed in PJIs caused by low-virulence organisms (AGR: 60%, CAR: 78%) compared to high-virulence pathogens (AGR: 80%, p = 0.042; CAR: 88%, p = 0.158). Higher sensitivities were seen in acute haematogenous (AGR: 83%, CAR: 96%) compared to chronic PJIs (AGR: 54%, p = 0.001; CAR: 65%, p < 0.001). Conclusion. Serum AGR and CAR showed limited diagnostic accuracy (especially in low-grade and chronic infections) and did not outperform the established marker CRP in our study. Hence, neither parameter can be recommended as an additional tool for diagnosing PJI. Cite this article: Bone Joint Res 2024;13(8):372–382


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results. We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion. This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential. Cite this article: Bone Joint J 2023;105-B(7):775–782


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 68 - 68
24 Nov 2023
Luger M Windhager R Sigmund I
Full Access

Aim. Serum parameters continue to be a focus of research in diagnosing periprosthetic joint infections (PJI). Several workgroups have recently proposed serum Albumin-Globulin-Ratio (AGR) as a potential new biomarker. Due to controversies in the literature, its usability in clinical practice remains uncertain. The aim of this study was to assess the value of serum AGR in diagnosing PJI preoperatively, especially in comparison with the well-established marker C-reactive Protein (CRP). Method. From January 2015 to June 2022, patients with indicated revision hip (rTHA) and knee (rTKA) arthroplasty were included in this retrospective cohort study of prospectively collected data. A standardized diagnostic workup was performed using the 2021 European Bone and Joint Infection Society (EBJIS) definition of PJI, excluding CRP. Diagnostic accuracies of serum AGR and CRP were calculated by receiver operating characteristic curve (ROC) analysis. A z-test was used to compare the area under the curves (AUC). Results. A total of 275 patients with rTHA and rTKA were included, 144 joints (52.4%) were identified as septic. Decreased AGR and elevated CRP were strongly associated with PJI, optimal diagnostic thresholds were calculated with 1.253 and 9.4 mg/L, respectively. Sensitivities were 62.5% (95%-confidence interval: 54.3–70.0) and 73.6% (65.8–80.1), and specificities 84.7% (77.5–89.9) and 87.8% (80.9–92.4), respectively. CRP showed a significantly higher AUC than AGR (0.807 (0.761–0.853) and 0.736 (0.686–0.786); p<0.0001). Subgroup analysis of acute versus chronic infections yielded significantly higher diagnostic accuracies in acute PJI for both parameters (p<0.0001). Similar results were observed when focusing on the causative microorganism; a better diagnostic performance was observed in high-virulence PJI compared to low-virulence PJI (p≤0.005). Furthermore, higher AUCs were calculated in knee PJI compared with hip PJI, with a significant difference for AGR (p=0.043). Conclusions. Due to its limited diagnostic accuracy, serum AGR cannot be recommended as an additional marker for diagnosing PJI. Serum parameters are generally unspecific and can be influenced by comorbidities and other foci of infection. Additionally, parameters may remain within normal levels in low-grade PJI. Evaluating AGR, further possible pitfalls must be considered, for example an increased latency until bottom values are reached and the impact of malnutrition


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 35 - 35
1 Dec 2021
Sigmund IK Holinka J Sevelda F Staats K Lass R Kubista B Giurea A Windhager R
Full Access

Aim. Although established serum inflammatory biomarkers, such as serum C-reactive protein (CRP) and serum white blood cell count (WBC), showed low accuracies in the literature, they are still commonly used in diagnosing periprosthetic joint infections (PJI). For a sufficient preoperative diagnosis novel more accurate serum parameters are needed. The aim of our study was to evaluate the performances of the established and novel routinely available serum parameters in diagnosing periprosthetic joint infections when using the proposed European Bone and Joint Infection Society (pEBJIS) criteria. Method. In this retrospective study, 177 patients with an indicated revision surgery after a total joint replacement were included from 2015 to 2019. The easily accessible and routinely available serum parameters CRP, WBC, the percentage of neutrophils (%N), the neutrophils to lymphocytes ratio (NLR), fibrinogen and the platelet count to mean platelet volume ratio (PC/mPV) were evaluated preoperatively. The performances were examined via receiver operating characteristic (ROC) curve analysis (AUC). The curves were compared using the z-test. Seventy-five cases (42%) showed a PJI based on the pEBJIS-criteria. Results. The sensitivities of serum CRP (cut-off: ≥10mg/L), WBC (≥10×10^9 cells/L), %N (≥69.3%), NLR(≥ 3.82), fibrinogen (≥ 457 mg/dL), and PC/mPV (≥ 29.4) were calculated with 68% (95% CI: 57–78), 36% (26 – 47), 66% (54 – 76), 63% (51 – 73), 69% (57 – 78), and 43% (32 – 54), respectively. Specificities were 87% (79 – 93), 89% (81 – 94), 67% (57 76), 73% (63 – 81), 89% (80 – 93), and 81% (72 – 88), respectively. Serum CRP and fibrinogen showed better performances than the other evaluated serum parameters (p<0.0001). The median serum CRP (17.6 mg/L) in patients with PJI caused by a low virulence microorganism was lower compared with infections caused by high virulence organisms (49.2 mg/L; p=0.044). Synovial fluid leucocyte count and histology showed better accuracies than serum CRP, serum WBC, %N, NLR, serum fibrinogen, and PC/mPV (p<0.0001). Conclusions. Although serum CRP and fibrinogen showed the best performances among the evaluated serum inflammatory markers, their results should be interpreted with caution in clinical practice. Serum parameters may remain normal in chronic infections or may be elevated in patients with other inflammatory conditions. In addition, they also correlated poorly with synovial fluid leukocyte count and histology. Therefore, serum parameters are still insufficient to confirm or exclude a periprosthetic joint infection. Hence, they can only be recommended as suggestive criteria in diagnosing PJI


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 38 - 38
1 Dec 2021
Yacovelli S Goswami K Shohat N Shahi A Parvizi J
Full Access

Aim. D-dimer is a widely available serum test that detects fibrinolytic activities that occur during infection. Prior studies have explored its utility for diagnosis of chronic periprosthetic joint infections (PJI), but not explored its prognostic value for prediction of subsequent treatment failure. The purpose of this study was to: (1) assess the ability of serum D-dimer and other standard-of-care serum biomarkers to predict failure following reimplantation, and (2) establish a new cutoff value for serum D-dimer for prognostic use prior to reimplantation. Method. This prospective study enrolled 92 patients undergoing reimplantation between April 2015 and March 2019 who had previously undergone total hip/knee resection arthroplasty with placement of an antibiotic spacer for treatment of chronic PJI. Serum D-dimer level, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) levels were measured preoperatively for all patients. Failure following implantation was defined per the Delphi consensus criteria. Optimal cutoffs for D-dimer, ESR, and CRP were calculated based on ROC curves and compared in their association with failure following reimplantation criteria at minimum 1-year follow-up. Results. 15/92(16.3%) patients failed reimplantation surgery at mean follow up of 2.9 years (range 1.0–4.8). Optimal thresholds for D-Dimer, ESR and CRP were determined to be 1300ng/mL, 30mm/hr, and 1mg/L, respectively. The failure rate in patient with positive D-dimer was significantly higher at 32.0% (8/25) compared to those with negative D-dimer 10.6% (7/66); p=0.024. In comparison, 17.8% (8/45) of patients with ESR above threshold failed, compared to 13.89% (5/41) below (p=0.555) and 16.0% (4/25) of patients with CRP above threshold failed, compared to 16.1% (10/62) below (p=1.000). Conclusions. Patients with elevated D-Dimer appear to be at higher risk of failure after reimplantation surgery. This serum marker may be used to generate an additional data point in patients undergoing reimplantation surgery, especially in circumstances when optimal timing of reimplantation cannot be determined based on clinical circumstances


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 13 - 13
19 Aug 2024
DeBenedetti A Weintraub MT Valle CJD Jacobs JJ Nam D
Full Access

The purpose of this randomized controlled trial was to evaluate serum metal levels in patients undergoing total hip arthroplasty (THA) with a conventional compared to a modular dual-mobility bearing. Patients undergoing primary THA for osteoarthritis were randomized to receive either a modular dual-mobility or conventional polyethylene bearing. All patients received the same titanium acetabular and femoral component and a ceramic femoral head. Serum metal levels were drawn pre-operatively then annually for a minimum of two years postoperatively. An a priori power analysis determined that 40 patients (20 per cohort) were needed to identify a clinically relevant difference in serum cobalt of 0.35 ng/ml (ppb) at 90% power. Forty-six patients were randomized to a modular dual-mobility (n=25) or conventional bearing (n=21) with 40 at a minimum follow-up of two years. No differences in serum cobalt (mean 0.14 ppb [range, 0.075–0.29] vs. 0.20 ppb [range, 0.075–0.57], p=0.39) or chromium levels (mean 0.14 ppb [range, 0.05–0.50] vs. 0.12 ppb [range, 0.05–0.35], p=0.65) were identified between the modular dual-mobility and conventional cohorts, respectively. There was no statistically significant difference in serum Co or Cr at two years postoperatively in subjects implanted with a ceramic head and this particular dual mobility bearing in comparison to a ceramic head and a conventional acetabular component. While modest expected elevations in serum Co and Cr were observed in the dual mobility group, in no case did the Co level exceed the laboratory reference range nor the threshold of one part per billion that has been associated with adverse local tissue reactions to mechanically-assisted crevice corrosion


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 34 - 34
11 Apr 2023
Kale S Mehra S Mehra K Shetty S Langade D Gunjotikar A Singh S
Full Access

Higher uric acid levels or hyperuricemia is a product of more uric acid production, dysfunctional renal excretion, or a combination of both leading to deposition of urate crystals in the joints and kidneys and has been strongly linked with the development of gout, that is, acute inflammatory arthritis. Uric acid levels have been suggested to depend on multiple factors including lifestyle, diet, alcohol consumption, etc. As these are risk parameters for hyperuricemia and since lifestyle choices vary amongst different Indian communities, we sought to study the prevalence of hyperuricemia in these communities. Also, large-scale data (in terms of gender, age, lifestyle, community) on the prevalence of hyperuricemia in subjects amongst different community populations, Hindu, Muslim, Sikh, and Christian was generated. In a retrospective study conducted at Dr. D. Y. Patil School of Medicine & Research Centre, Navi Mumbai from April 2018 to May 2021, information was gathered from four major communities on a range of indicators including serum uric acid levels followed by a thorough multilevel logistic analysis. We evaluated uric acid levels in 10,378 patients of four different communities. Outcomes were assessed biochemically as well as clinically based on the levels of serum uric acid. The mean serum uric acid levels were highest in Sikhs (7.6 mg%, n=732) followed by Christians (7.3 mg%, n=892) and then by Hindus (5.9 mg%, n=6846) and Muslims (5.6 mg%, n=1908). About 83.7% of Christians consumed meat in a non-vegetarian diet followed by 45.7% Muslims. Percentage of Christians who binge drink were highest whereas percentage of Sikh people in the heavy drinkers’ category were 5.2%. Further, 9.5% Hindus were current smokers followed by 7.8% Sikhs who smoked at present. Overall, our study of 10,378 patients demonstrated that the serum uric acid levels varied from one Indian community to another due to varying external factors like diet, age, lifestyle, and addictions. Thus, lifestyle modification in communities with higher serum uric acid levels is highly advocated and this may reduce the healthcare burden of gouty arthritis in these communities


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 904 - 911
1 Jul 2020
Sigmund IK Dudareva M Watts D Morgenstern M Athanasou NA McNally MA

Aims. The aim of this study was to evaluate the diagnostic value of preoperative serum CRP, white blood cell count (WBC), percentage of neutrophils (%N), and neutrophil to lymphocyte ratio (NLR) when using the fracture-related infection (FRI) consensus definition. Methods. A cohort of 106 patients having surgery for suspected septic nonunion after failed fracture fixation were studied. Blood samples were collected preoperatively, and the concentration of serum CRP, WBC, and differential cell count were analyzed. The areas under the curve (AUCs) of diagnostic tests were compared using the z-test. Regression trees were constructed and internally cross-validated to derive a simple diagnostic decision tree. Results. Using the FRI consensus definition, 46 patients (43%) were identified as infected. Sensitivity, specificity, and AUC of CRP were 67% (95% confidence interval (CI) 52% to 80%), 61% (95% CI 47% to 74%), and 0.64 (95% CI 0.54 to 0.74); of WBC count were 17% (95% CI 9% to 31%), 95% (95% CI 86% to 99%), and 0.57 (95% CI 0.50 to 0.62); of %N 13% (95% CI 6% to 26%), 87% (95% CI 76% to 93%), and 0.50 (95% CI 0.43 to 0.56); and of NLR 28% (95% CI 17% to 43%), 80% (95% CI 68% to 88%), and 0.54 (95% CI 0.46 to 0.63), respectively. A better performance of serum CRP was shown in comparison to the leucocyte count (p = 0.006), %N (p < 0.001), and NLR (p = 0.001). A statistically lower serum CRP level was shown in patients with an infection caused by a low virulence microorganism in comparison to high virulence bacteria (p = 0.008). We found that a simple decision tree approach using only low serum neutrophils (< 3.615 × 10. 9. /l) and low CRP (< 2.45 mg/l) may allow better identification of aseptic cases. Conclusion. The evaluated serum inflammatory markers showed limited diagnostic value in the preoperative diagnosis of FRI when using the uniform FRI Consensus Definition. Therefore, they should remain as suggestive criteria in diagnosing FRI. Although CRP showed a higher performance in comparison to the other serum markers, it is insufficiently accurate to diagnose a septic nonunion, especially when caused by low virulence microorganisms. Cite this article: Bone Joint J 2020;102-B(7):904–911


Bone & Joint Research
Vol. 7, Issue 1 | Pages 85 - 93
1 Jan 2018
Saleh A George J Faour M Klika AK Higuera CA

Objectives. The diagnosis of periprosthetic joint infection (PJI) is difficult and requires a battery of tests and clinical findings. The purpose of this review is to summarize all current evidence for common and new serum biomarkers utilized in the diagnosis of PJI. Methods. We searched two literature databases, using terms that encompass all hip and knee arthroplasty procedures, as well as PJI and statistical terms reflecting diagnostic parameters. The findings are summarized as a narrative review. Results. Erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) were the two most commonly published serum biomarkers. Most evidence did not identify other serum biomarkers that are clearly superior to ESR and CRP. Other serum biomarkers have not demonstrated superior sensitivity and have failed to replace CRP and ESR as first-line screening tests. D-dimer appears to be a promising biomarker, but more research is necessary. Factors that influence serum biomarkers include temporal trends, stage of revision, and implant-related factors (metallosis). Conclusion. Our review helped to identify factors that can influence serum biomarkers’ level changes; the recognition of such factors can help improve their diagnostic utility. As such, we cannot rely on ESR and CRP alone for the diagnosis of PJI prior to second-stage reimplantation, or in metal-on-metal or corrosion cases. The future of serum biomarkers will likely shift towards using genomics and proteomics to identify proteins transcribed via messenger RNA in response to infection and sepsis. Cite this article: A. Saleh, J. George, M. Faour, A. K. Klika, C. A. Higuera. Serum biomarkers in periprosthetic joint infections. Bone Joint Res 2018;7:85–93. DOI: 10.1302/2046-3758.71.BJR-2017-0323


Bone & Joint Research
Vol. 12, Issue 11 | Pages 691 - 701
3 Nov 2023
Dai Z Chen Y He E Wang H Guo W Wu Z Huang K Zhao Q

Aims. Osteoporosis is characterized by decreased trabecular bone volume, and microarchitectural deterioration in the medullary cavity. Interleukin-19 (IL-19), a member of the IL-10 family, is an anti-inflammatory cytokine produced primarily by macrophages. The aim of our study was to investigate the effect of IL-19 on osteoporosis. Methods. Blood and femoral bone marrow suspension IL-19 levels were first measured in the lipopolysaccharide (LPS)-induced bone loss model. Small interfering RNA (siRNA) was applied to knock down IL-19 for further validation. Thereafter, osteoclast production was stimulated with IL-19 in combination with mouse macrophage colony-stimulating factor (M-CSF) and receptor activator of nuclear factor-κB ligand (RANKL). The effect of IL-19 was subsequently evaluated using tartrate-resistant acid phosphatase (TRAP) staining and quantitative real-time polymerase chain reaction (RT-qPCR). The effect of IL-19 on osteoprotegerin (OPG) was then assessed using in vitro recombinant IL-19 treatment of primary osteoblasts and MLO-Y4 osteoblast cell line. Finally, transient transfection experiments and chromatin immunoprecipitation (ChIP) experiments were used to examine the exact mechanism of action. Results. In the LPS-induced bone loss mouse model, the levels of IL-19 in peripheral blood serum and femoral bone marrow suspension were significantly increased. The in vivo results indicated that global IL-19 deletion had no significant effect on RANKL content in the serum and bone marrow, but could increase the content of OPG in serum and femoral bone marrow, suggesting that IL-19 inhibits OPG expression in bone marrow mesenchymal stem cells (BMSCs) and thus increases bone resorption. Conclusion. IL-19 promotes bone resorption by suppressing OPG expression in BMSCs in a LPS-induced bone loss mouse model, which highlights the potential benefits and side effects of IL-19 for future clinical applications. Cite this article: Bone Joint Res 2023;12(11):691–701


Bone & Joint Research
Vol. 9, Issue 9 | Pages 587 - 592
5 Sep 2020
Qin L Li X Wang J Gong X Hu N Huang W

Aims. This study aimed to explore whether serum combined with synovial interleukin-6 (IL-6) measurement can improve the accuracy of prosthetic joint infection (PJI) diagnosis, and to establish the cut-off values of IL-6 in serum and synovial fluid in detecting chronic PJI. Methods. Patients scheduled to have a revision surgery for indications of chronic infection of knee and hip arthroplasties or aseptic loosening of an implant were prospectively screened before being enrolled into this study. The Musculoskeletal Infection Society (MSIS) definition of PJI was used for the classification of cases as aseptic or infected. Serum CRP, ESR, IL-6, and percentage of polymorphonuclear neutrophils (PMN%) and IL-6 in synovial fluid were analyzed. Statistical tests were performed to compare these biomarkers in the two groups, and receiver operating characteristic (ROC) curves and area under the curve (AUC) were analyzed for each biomarker. Results. A total of 93 patients were enrolled. There was no difference in demographic data between both groups. Synovial fluid IL-6, with a threshold of 1,855.36 pg/ml, demonstrated a mean sensitivity of 94.59% (95% confidence interval (CI) 81.8% to 99.3%) and a mean specificity of 92.86% (95% CI 82.7 to 98.0) for detecting chronic PJI. Then 6.7 pg/ml was determined to be the optimal threshold value of serum IL-6 for the diagnosis of chronic PJI, with a mean sensitivity of 97.30% (95% CI 85.8% to 99.9%) and a mean specificity of 76.79% (95% CI 63.6% to 87.0%). The combination of synovial IL-6 and serum IL-6 led to improved accuracy of 96.77% in diagnosing chronic PJI. Conclusion. The present study identified that a combination of IL-6 in serum and synovial IL-6 has the potential for further improvement of the diagnosis of PJI. Cite this article: Bone Joint Res 2020;9(9):587–592


Bone & Joint Research
Vol. 12, Issue 7 | Pages 423 - 432
6 Jul 2023
Xie H Wang N He H Yang Z Wu J Yang T Wang Y

Aims. Previous studies have suggested that selenium as a trace element is involved in bone health, but findings related to the specific effect of selenium on bone health remain inconclusive. Thus, we performed a meta-analysis by including all the relevant studies to elucidate the association between selenium status (dietary intake or serum selenium) and bone health indicators (bone mineral density (BMD), osteoporosis (OP), or fracture). Methods. PubMed, Embase, and Cochrane Library were systematically searched to retrieve relevant articles published before 15 November 2022. Studies focusing on the correlation between selenium and BMD, OP, or fracture were included. Effect sizes included regression coefficient (β), weighted mean difference (WMD), and odds ratio (OR). According to heterogeneity, the fixed-effect or random-effect model was used to assess the association between selenium and bone health. Results. From 748 non-duplicate publications, 19 studies were included. We found a significantly positive association between dietary selenium intake (β = 0.04, 95% confidence interval (CI) 0.00 to 0.07, p = 0.029) as well as serum selenium (β = 0.13, 95% CI 0.00 to 0.26, p = 0.046) and BMD. Consistently, those with higher selenium intake had a lower risk of OP (OR = 0.47, 95% CI 0.31 to 0.72, p = 0.001), and patients with OP had a significantly lower level of serum selenium than healthy controls (WMD = -2.01, 95% CI -3.91 to -0.12, p = 0.037). High dietary selenium intake was associated with a lower risk of hip fracture (OR = 0.44, 95% CI 0.37 to 0.52, p < 0.001). Conclusion. Selenium was positively associated with BMD and inversely associated with OP; dietary selenium intake was negatively associated with hip fracture. The causality and therapeutic effect of selenium on OP needs to be investigated in future studies. Cite this article: Bone Joint Res 2023;12(7):423–432


Bone & Joint Research
Vol. 11, Issue 8 | Pages 528 - 540
1 Aug 2022
Dong W Postlethwaite BC Wheller PA Brand D Jiao Y Li W Myers LK Gu W

Aims. This study investigated the effects of β-caryophyllene (BCP) on protecting bone from vitamin D deficiency in mice fed on a diet either lacking (D-) or containing (D+) vitamin D. Methods. A total of 40 female mice were assigned to four treatment groups (n = 10/group): D+ diet with propylene glycol control, D+ diet with BCP, D-deficient diet with control, and D-deficient diet with BCP. The D+ diet is a commercial basal diet, while the D-deficient diet contains 0.47% calcium, 0.3% phosphorus, and no vitamin D. All the mice were housed in conditions without ultraviolet light. Bone properties were evaluated by X-ray micro-CT. Serum levels of klotho were measured by enzyme-linked immunosorbent assay. Results. Under these conditions, the D-deficient diet enhanced the length of femur and tibia bones (p < 0.050), and increased bone volume (BV; p < 0.010) and trabecular bone volume fraction (BV/TV; p < 0.010) compared to D+ diet. With a diet containing BCP, the mice exhibited higher BV and bone mineral density (BMD; p < 0.050) than control group. The trabecular and cortical bone were also affected by vitamin D and BCP. In addition, inclusion of dietary BCP improved the serum concentrations of klotho (p < 0.050). In mice, klotho regulates the expression level of cannabinoid type 2 receptor (Cnr2) and fibroblast growth factor 23 (Fgf23) through CD300a. In humans, data suggest that klotho is connected to BMD. The expression of klotho is also associated with bone markers. Conclusion. These data indicate that BCP enhances the serum level of klotho, leading to improved bone properties and mineralization in an experimental mouse model. Cite this article: Bone Joint Res 2022;11(8):528–540


Bone & Joint Research
Vol. 9, Issue 3 | Pages 146 - 151
1 Mar 2020
Waldstein W Koller U Springer B Kolbitsch P Brodner W Windhager R Lass R

Aims. Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing. Methods. The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery. Results. The median cobalt concentration in the MoM group was 1.04 μg/l (interquartile range (IQR) 0.64 to 1.70) at a mean of 21 years (20 to 24) postoperatively and these values were similar (p = 0.799) to cobalt levels at five years. In the CoP control group, the median cobalt levels were below the detection limit (< 0.3 μg/l; median 0.15 μg/l, IQR 0.15 to 0.75) at 20 years. The mean Harris Hip Score was 91.4 points (61 to 100) in the MoM group and 92.8 points (63 to 100) in the CoP group. Conclusion. This study represents the longest follow-up series evaluating the serum cobalt levels after 28 mm head MoM bearing THA and shows that serum cobalt concentrations remain at low levels at a mean of 21 years (20 to 24) after implantation. Cite this article:Bone Joint Res. 2020;9(3):145–150


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 21 - 21
1 Nov 2021
DeBenedetti A Della Valle CJ Jacobs JJ Nam D
Full Access

The purpose of this randomized controlled trial was to evaluate serum metal ion levels in patients undergoing THA with either a standard or modular dual-mobility bearing. Patients undergoing primary THA for osteoarthritis were randomized to receive either a modular dual-mobility or a standard polyethylene bearing. All patients received the same titanium acetabular and femoral component and a ceramic femoral head. Only patients without a prior history of metal implants in their body were eligible for inclusion, thus isolating serum metal ions to the prosthesis itself. Serum metal ion levels were drawn pre-operatively and at 1 year postoperatively. Power analysis determined that 40 patients (20 in each group) were needed to identify a clinically relevant difference in serum cobalt of 0.35 ng/ml (ppb) at 90% power assuming a pooled standard deviation of 0.31 ppb and alpha=0.05; an additional 30% were enrolled to account for potential dropouts. 53 patients were enrolled, with 22 patients in the modular dual-mobility group and 20 in the standard cohort with data available at one-year. No differences in the serum cobalt (0.17 ppb [range 0.07 to 0.50] vs. 0.19 ppb [range 0.07 to 0.62], p = 0.51) or chromium levels (0.19 ppb [range 0.05 to 0.56] vs. 0.16 ppb [range 0.05 to 0.61], p = 0.23) were identified. At 1 year postoperatively, no differences in serum cobalt or chromium levels were identified with this design of a modular dual mobility bearing when compared to a standard polyethylene bearing


Bone & Joint Research
Vol. 8, Issue 3 | Pages 146 - 155
1 Mar 2019
Langton DJ Natu S Harrington CF Bowsher JG Nargol AVF

Objectives. We investigated the reliability of the cobalt-chromium (CoCr) synovial joint fluid ratio (JFR) in identifying the presence of a severe aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) response and/or suboptimal taper performance (SOTP) following metal-on-metal (MoM) hip arthroplasty. We then examined the possibility that the CoCr JFR may influence the serum partitioning of Co and Cr. Methods. For part A, we included all revision surgeries carried out at our unit with the relevant data, including volumetric wear analysis, joint fluid (JF) Co and Cr concentrations, and ALVAL grade (n = 315). Receiver operating characteristic curves were constructed to assess the reliability of the CoCr JFR in identifying severe ALVAL and/or SOTP. For part B, we included only patients with unilateral prostheses who had given matched serum and whole blood samples for Co and Cr analysis (n = 155). Multiple regression was used to examine the influence of JF concentrations on the serum partitioning of Co and Cr in the blood. Results. A CoCr JFR > 1 showed a specificity of 83% (77% to 88%) and sensitivity of 63% (55% to 70%) for the detection of severe ALVAL and/or SOTP. In patients with CoCr JFRs > 1, the median blood Cr to serum Cr ratio was 0.99, compared with 0.71 in patients with CoCr JFRs < 1 (p < 0.001). Regression analysis demonstrated that the blood Cr to serum Cr value was positively associated with the JF Co concentration (p = 0.011) and inversely related to the JF Cr concentration (p < 0.001). Conclusion. Elevations in CoCr JFRs are associated with adverse biological (severe ALVAL) or tribocorrosive processes (SOTP). Comparison of serum Cr with blood Cr concentrations may be a useful additional clinical tool to help to identify these conditions. Cite this article: D. J. Langton, S. Natu, C. F. Harrington, J. G. Bowsher, A. V. F. Nargol. Is the synovial fluid cobalt-to-chromium ratio related to the serum partitioning of metal debris following metal-on-metal hip arthroplasty? Bone Joint Res 2019;8:146–155. DOI: 10.1302/2046-3758.83.BJR-2018-0049.R1


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 92 - 92
1 Dec 2019
Sigmund IK Morgenstern M Dudareva M Athanasou N McNally M
Full Access

Background. Preoperative diagnosis of fracture related infections can be challenging, especially when confirmatory criteria such as sinus tract and purulent discharge are absent. Although serum parameters, such as CRP and white blood cell count (WBC), showed poor accuracy in the literature, they are still often used in clinical practice. The European Bone and Joint Infection Society (EBJIS) defined evidence-based criteria for fracture related infection. Elevated serum inflammatory markers were regarded as suggestive criteria only, as the literature was of limited quality. This study assessed the diagnostic value of the serum parameters CRP, WBC and differential cell count in the diagnosis of fracture related infections defined by the EBJIS-criteria for fracture related infections. Methods. In this retrospective cohort study, 94 patients who underwent surgical treatment for suspected infected non unions after failed fracture fixation were included. Preoperatively, blood samples including serum inflammatory markers were taken. For this study, cut-offs of 5 mg/L for CRP, 10×10⁁9 cells/L for WBC, and >70% for the percentage of neutrophils were regarded as positive for infection. All patients had intraoperative samples taken for microbiology and histology. Analysis of diagnostic accuracy was based on the receiver-operating characteristic (ROC). Results. Based on the EBJIS criteria, 40 patients (43%) were diagnosed with a fracture related infection. 11/94 (12%) patients had an elevated serum WBC count, 13/94 (14%) an increased percentage of neutrophils, and 43/82 (52%) an elevated serum CRP. The mean values of CRP concentration, WBC count, and percentage of neutrophils in the infection group were 7.9 mg/L (IQR:6.4 – 9.7), 18.3 G/l (IQR: 3.9 – 24.9), and 63% (IQR: 58 – 67%), respectively. The sensitivity, specificity, and area under the curve of serum WBC count were 20% (95% CI: 10 −35%), 94.4% (84 −99%), and 0.57 (0.50 – 0.64), respectively; of percentage of neutrophils 12.5% (5 – 27%), 85.2% (73 −93%), and 0.49 (0.42 – 0.56); and of serum CRP 67.6% (51 – 90%), 60.0% (45 – 73%), and 0.64 (0.53 – 0.74), respectively. A statistically significant difference between the AUCs of all three serum parameters and AUC of tissue culture as well as AUC of histology was shown (p <0.0001). A simple decision tree approach using only low WBC and CRP may allow identification of aseptic cases. Conclusion. Based on the standardized and evidence-based EBJIS criteria, the three inflammatory serum markers showed an insufficient accuracy for the diagnosis of fracture related infections. They also correlate poorly with culture or histological diagnosis. Therefore, they should not be used alone as a confirmatory test


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 540 - 547
1 Jun 2024
Nandra RS Elnahal WA Mayne A Brash L McBryde CW Treacy RBC

Aims. The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. Methods. The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken. Results. Overall implant survival was 83.50% (95% confidence interval (CI) 0.79 to 0.90) at 25 years, and the number at risk was 79. Survival in male patients at 25 years was 89.5% (95% CI 0.83 to 0.96) compared to 66.9% for female patients (95% CI 0.51 to 0.83). Ten additional failures occurred in the period of ten to 25 years. These involved an adverse reaction to metal debris in four patients, a periprosthetic femoral neck fracture affecting five patients, and aseptic loosening in one patient. The median chromium levels were 49.50 nmol/l (interquartile range (IQR) 34 to 70), and the median cobalt serum levels were 42 nmol/l (IQR 24.50 to 71.25). The median OHS at last follow-up was 35 (IQR 10 to 48). During the 25-year study period, 29 patients died. Patient survival at 25 years was 75.10% (95% CI 0.67 to 0.83). Conclusion. This study demonstrates that MoM hip resurfacing using the BHR provides a durable alternative to total hip arthroplasty (THA), particularly in younger male patients with osteoarthritis wishing to maintain a high level of function. These results compare favourably to the best results for THAs. Cite this article: Bone Joint J 2024;106-B(6):540–547


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 30 - 30
4 Apr 2023
Neunaber C Long Y Noack S Krettek C Bundkirchen K
Full Access

Due to their immunomodulatory and regenerative capacity, human bone marrow-derived mesenchymal stromal cells (hBMSCs) are promising in the treatment of polytrauma patients. However, few studies evaluated the effects of sera from polytraumatized patients on hBMSCs. The aim of this study was to explore changes in hBMSCs exposed to serum from polytrauma patients from different time points after trauma. Sera from 84 patients on day 1 (D1), 5 (D5) and 10 (D10) after polytrauma (ISS ≥ 16) were pooled respectively to test the differential influence on hBMSC. As a control, sera from three healthy age- and gender-matched donors (HS) were collected. The pooled sera were analyzed by Multicytokine Array for pro-/anti-inflammatory cytokines. For the cell culture experiments, hBMSCs from four healthy donors were used. The influence of the different sera on hBMSC regarding cell proliferation, colony forming unit-fibroblast (CFU-F) assay, cell viability and toxicity, cell migration, as well as osteogenic and chondrogenic differentiation was analyzed. One-Way-ANOVA and LSD-test were used for the parametric, Kruskal-Wallis-test for non-parametric data. p≤0.05 was considered as statistically significant. The results showed that D5 serum reduced hBMSCs cell proliferation capacity by 41.26% (p=0.000) compared with HS and increased the proportion of dead cells by 3.19% (p=0.008) and 2.25% (p=0.020) compared with D1 and D10. The frequency of CFU-F was reduced by 49.08% (p=0.041) in D5 and 53.99% (p=0.027) in D10 compared with HS, whereas the other parameters were not influenced. The serological effect of polytrauma on hBMSCs was related to the time after trauma. It is disadvantageous to use BMSCs in polytraumatized patients five days after the incidence as obvious cytological changes could be found at that time point. However, it is promising to use hBMSCs to treat polytrauma after 10 days, combined with the concept of “Damage Control Orthopaedics” (DCO)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 33 - 33
1 Dec 2021
Logoluso N Balato G Pellegrini AV De Vecchi E Romanò CL Drago L Lenzi M Ascione T
Full Access

Aim. Despite the availability of numerous tests, the diagnosis of periprosthetic infection (PJI) continues to be complex. Although several studies have suggested that coagulation-related markers, such as D-dimer and fibrinogen, may be promising tools in the diagnosis of prosthetic infections, their role is still controversial. The aim of this study is to evaluate the diagnostic accuracy of serum D-dimer and fibrinogen in patients with painful total knee replacement. Method. 83 patients with painful total knee replacement and suspected peri-prosthetic infection were included. All patients underwent pre-operative blood tests to evaluate inflammation indices (ESR and CRP) and serum D-Dimer and Fibrinogen levels. The diagnostic performance of the tests was assessed using the ICM definition as the gold standard. The diagnostic accuracy of the D-dimer and fibrinogen was measured by assessing sensitivity, specificity and by calculating the area under the ROC curve. Results. The definition of prosthetic infection based on the ICM criteria has made it possible to classify 40 peri-prosthetic infections and 43 aseptic failures. The mean value of fibrinogen, D-Dimer, VES and PCR observed in patients with prosthetic infection was significantly higher than in patients with aseptic failure [fibrinogen 468 mg / dl vs 331 mg / dl, p <0.001; D-Dimero 2177 ng/mL vs. 875 ng / mL, p <0.005], ESR 49 mm / hr vs 24 mm/h, p <0.001; PCR 25.5 mg /L vs 8.9 mg/L, p <0.001]. The optimal threshold value of the fibrinogen indicative of the presence of infection was 418 mg/dl, with a sensitivity of 72% and a specificity of 88%. The serum concentration of d-dimer greater than 945 ng / ml showed a sensitivity of 72.5% and a specificity of 76.7%. Conclusions. Although in this multicenter prospective study we found that serum D-dimer may have significantly higher statistical values in PJI than aseptic failures, its diagnostic power appears however limited when compared with other markers including plasma fibrinogen. Fibrinogen is regularly analyzed before surgery, the evaluation of this marker does not involve additional costs. The diagnostic accuracy appears to be similar to that of classic markers such as the level of PCR and VES. Plasma D-dimer may have a limited value in the diagnosis of PJI unlike plasma fibrinogen which has shown moderate sensitivity and excellent specificity. However, in our limited series of cases, both tests cannot be used alone in the diagnosis of infection but could contribute to the diagnosis if contextualized to ves and pcr