The aim of this study was to explore current use of the Global Fragility Fracture Network (FFN) Minimum Common Dataset (MCD) within established national hip fracture registries, and to propose a revised MCD to enable international benchmarking for hip fracture care. We compared all ten established national hip fracture registries: England, Wales, and Northern Ireland; Scotland; Australia and New Zealand; Republic of Ireland; Germany; the Netherlands; Sweden; Norway; Denmark; and Spain. We tabulated all questions included in each registry, and cross-referenced them against the 32 questions of the MCD dataset. Having identified those questions consistently used in the majority of national audits, and which additional fields were used less commonly, we then used consensus methods to establish a revised MCD.Aims
Methods
Aims. Bone health assessment and the prescription of medication for
Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.Aims
Methods
The aim of this study was to describe the current pathways of care for patients with a fracture of the hip in five low- and middle-income countries (LMIC) in South Asia (Nepal and Sri Lanka) and Southeast Asia (Malaysia, Thailand, and the Philippines). The World Health Organization Service Availability and Readiness Assessment tool was used to collect data on the care of hip fractures in Malaysia, Thailand, the Philippines, Sri Lanka, and Nepal. Respondents were asked to provide details about the current pathway of care for patients with hip fracture, including pre-hospital transport, time to admission, time to surgery, and time to weightbearing, along with healthcare professionals involved at different stages of care, information on discharge, and patient follow-up.Aims
Methods
Current levels of hip fracture morbidity contribute greatly to the overall burden on health and social care services. Given the anticipated ageing of the population over the coming decade, there is potential for this burden to increase further, although the exact scale of impact has not been identified in contemporary literature. We therefore set out to predict the future incidence of hip fracture and help inform appropriate service provision to maintain an adequate standard of care. Historical data from the Scottish Hip Fracture Audit (2017 to 2021) were used to identify monthly incidence rates. Established time series forecasting techniques (Exponential Smoothing and Autoregressive Integrated Moving Average) were then used to predict the annual number of hip fractures from 2022 to 2029, including adjustment for predicted changes in national population demographics. Predicted differences in service-level outcomes (length of stay and discharge destination) were analyzed, including the associated financial cost of any changes.Aims
Methods
The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors.Aims
Methods
A consecutive series of 320 patients with an
intracapsular fracture of the hip treated with a dynamic locking
plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients
were followed for a minimum of two years. During the follow-up period
109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed
nonunion or re-displacement and five (4.5%) developed avascular
necrosis of the femoral head. Revision to an arthroplasty was required
for five patients (4.5%). A further six patients (5.4%) had elective
removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed
nonunion or re-displacement and 23 (11.1%) developed avascular necrosis.
A further four patients (1.9%) developed a
Introduction. In elderly patients, the incidence of a second fracture in the contralateral hip within 2 years of a femoral neck fracture (FNF), ranges from 7 to 12%. Hypothesis. We want to evaluate the safety and efficacy of the Prevention Nail System (PNS), a titanium screw with a hydroxyapatite-coated thread, developed to prevent contralateral FNFs in severe osteoporotic patients. Materials and methods. From September 2008 to May 2012, 80 osteoporotic FNF patients (Tscore<;−2.5) were recruited. Patients received standard care for the fractured hip and were randomized to receive either the PNS (Group A), or nothing (Group B) in the contralateral hip. DXA, CT and X-rays of the reinforced hip were scheduled at 3, 12 and 24 months postoperative. Results. Average follow-up was 26 months. Twenty-one patients reported secondary falls. Group A: 13 patients with 9 osteoporotic fractures (3 contralateral subtrochanteric); Group B: 6 patients with a second osteoporotic fracture (3 contralateral FNF). CT scans showed no radiolucencies or PNS loosenings. Discussion and Conclusion. In Group A the hip fractures had a spiroid rime beginning from the lateral cortical entry hole; FNFs were fixed with the PNS plate. The
Minimally invasive fixation of pelvic fragility fractures is recommended to reduce pain and allow early mobilization. The purpose of this study was to evaluate the outcome of two different stabilization techniques in bilateral fragility fractures of the sacrum (BFFS). A non-randomized, prospective study was carried out in a level 1 trauma centre. BFFS in 61 patients (mean age 80 years (SD 10); four male, 57 female) were treated surgically with bisegmental transsacral stablization (BTS; n = 41) versus spinopelvic fixation (SP; n = 20). Postoperative full weightbearing was allowed. The outcome was evaluated at two timepoints: discharge from inpatient treatment (TP1; Fitbit tracking, Zebris stance analysis), and ≥ six months (TP2; Fitbit tracking, Zebris analysis, based on modified Oswestry Disability Index (ODI), Majeed Score (MS), and the 12-Item Short Form Survey 12 (SF-12). Fracture healing was assessed by CT. The primary outcome parameter of functional recovery was the per-day step count; the secondary parameter was the subjective outcome assessed by questionnaires.Aims
Methods
We report four patients who sustained
Introduction. Since 2001 we use the flexible intramedullary nailing (FIN) in bone lengthening in children. This study estimates results of EF+FIN association considering the duration of external fixation and complications. Materials and Methods. Since 2001 we performed 294 bone lengthenings (338 segments of UL and LL) in 250 children 3 to 16 years old (11.01±0.23 in average). The length discrepancy was congenital in 163 cases, the sequelae of trauma or osteomyelitis were observed in 87 patients. In group I (195 cases) the Ilizarov fixator alone was applied, in group II the Ilizarov fixator (91 cases) or TSF® (8cases) were combined with FIN. The healing index was compared between the groups of the same etiology with similar type of distraction osteosynthesis. The date of consolidation corresponded to the day of removal of the external fixator, while intramedullary nails remained in place thus protecting the bone. Healing index was calculated by relating the duration of wearing of the external fixator (in days) and the amount of lengthening (in cm). Results. Reduction of the healing index is noted in each compared category. Thus, in congenital shortening in monofocal distraction osteosynthesis of the femur the healing index decreased from 29.8 (group I) to 20.4 days per cm, in bifocal tibial lengthening from 22.7 (group I) to 16.3d/cm (group II), in humeral lengthening – from 30.2 to 21.3 d/cm. In fact, it appears that the association of the external fixator of the Ilizarov type or TSF® with FIN allows to reduce the healing index significantly: in 12 of 16 compared categories the reduction of the index was from 20% to 40% or from 4.0 to 19.1 days per cm. In group I four cases of deep infection of soft tissues, 2 osteomyelitis, 21 fractures or deformities after frame removal were manifested. In group II – onlyone case of deformation after frame removal, absence of severe infectious complications, 8 cases of migration of the intramedullary wires. Discussion. FIN creates an elastic and resistant system during the lengthening. We even suggest that it stimulates the formation considering an apparent decrease of the healing index. On the other hand, the elasticity of nails prevents
In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up.Aims
Patients and Methods
Aims. Dual SC Screw (DSCS) is a novel fixation device for the femoral neck fracture. DSCS is comprised of screw and barrel allowing sliding of the screw and preventing protrusion of the screw end. Two types of the barrels are available, threaded barrel (TB) and plate barrel (PB). Ordinarily, both barrels are implanted. Concept of the design is that the PB contributes stability to the screw against the varus force of the femoral head while the additional screw with TB prevents rotational deformity. The aim of this study was to represent clinical results after DSCS operation in patients with femoral neck fracture. Method. Fifty-one patients with femoral neck fractures treated using DSCS and at least 3 months follow up are included and their clinical was evaluated. Result. Most fractures healed uneventfully. Cut out was occurred in two patients, perforation of the femoral head in one, femoral head necrosis in two, subtrochanteric fracture in one and 1backout of screw in one. The cases except that are excellent postoperative results. Discussion and Conclusion. Most complication was associated with some technical problems and all but one patients without that showed excellent results even for displaced
INTRODUCTION. In recent years the age of world's population has risen and with it there has been a significant increase in the frequency of hip fractures in the elderly. These fractures are known to increase morbidity and mortality. However, little is known about the frequency and characteristics of patients who sustain a second hip fracture. We examined the incidence and the underlying associated medical disorders of patients with a second fracture in the other hip. MATERIAL & METHODS. This study consists of 132/1208 Pts. (10.9%) treated in our department between 1998–2006 that had a
Fractures of the distal femur can be challenging to manage and
are on the increase in the elderly osteoporotic population. Management
with casting or bracing can unacceptably limit a patient’s ability
to bear weight, but historically, operative fixation has been associated
with a high rate of re-operation. In this study, we describe the outcomes
of fixation using modern implants within a strategy of early return
to function. All patients treated at our centre with lateral distal femoral
locking plates (LDFLP) between 2009 and 2014 were identified. Fracture
classification and operative information including weight-bearing
status, rates of union, re-operation, failure of implants and mortality
rate, were recorded.Aims
Patients and Methods
The spiral blade modification of the Dynamic
Hip Screw (DHS) was designed for superior biomechanical fixation
in the osteoporotic femoral head. Our objective was to compare clinical
outcomes and in particular the incidence of loss of fixation. In a series of 197 consecutive patients over the age of 50 years
treated with DHS-blades (blades) and 242 patients treated with conventional
DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were
identified from a prospectively compiled database in a level 1 trauma
centre. Using propensity score matching, two groups comprising 177
matched patients were compiled and radiological and clinical outcomes
compared. In each group there were 66 males and 111 females. Mean
age was 83.6 (54 to 100) for the conventional DHS group and 83.8
(52 to 101) for the blade group. Loss of fixation occurred in two blades and 13 DHSs. None of
the blades had observable migration while nine DHSs had gross migration
within the femoral head before the fracture healed. There were two
versus four implant cut-outs respectively and one side plate pull-out
in the DHS group. There was no significant difference in mortality
and eventual walking ability between the groups. Multiple logistic
regression suggested that poor reduction (odds ratio (OR) 11.49,
95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation
by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent
predictors of loss of fixation. The spiral blade design may decrease the risk of implant migration
in the femoral head but does not reduce the incidence of cut-out
and reoperation. Reduction of the fracture is of paramount importance
since poor reduction was an independent predictor for loss of fixation
regardless of the implant being used. Cite this article:
This multicentre prospective clinical trial aimed
to determine whether early administration of alendronate (ALN) delays
fracture healing after surgical treatment of fractures of the distal
radius. The study population comprised 80 patients (four men and
76 women) with a mean age of 70 years (52 to 86) with acute fragility
fractures of the distal radius requiring open reduction and internal
fixation with a volar locking plate and screws. Two groups of 40 patients
each were randomly allocated either to receive once weekly oral
ALN administration (35 mg) within a few days after surgery and continued
for six months, or oral ALN administration delayed until four months
after surgery. Postero-anterior and lateral radiographs of the affected
wrist were taken monthly for six months after surgery. No differences
between groups was observed with regard to gender (p = 1.0), age
(p = 0.916), fracture classification (p = 0.274) or bone mineral
density measured at the spine (p = 0.714). The radiographs were
assessed by three independent assessors. There were no significant
differences in the mean time to complete cortical bridging observed
between the ALN group (3.5 months ( Cite this article:
Osteoporosis and fragility fractures in men constitute a considerable burden in healthcare. We have reviewed 2035 men aged over 50 years with 2142 fractures to clarify the epidemiology of these injuries and their underlying risk factors. The prevalence of osteoporosis ranged between 17.5% in fractures of the ankle and 57.8% in those of the hip. The main risk factors associated with osteoporosis were smoking (47.4%), alcohol excess (36.2%), body mass index <
21 (12.8%) and a family history of osteoporosis (8.4%). Immobility, smoking, self-reported alcohol excess, a low body mass index, age ≥72 and loss in height were significantly more common among men with fractures of the hip than in those with fractures elsewhere.
Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture.
We determined the age-specific incidence of a second fracture of the hip and compared it with that of a primary fracture in a study population drawn from 6331 patients admitted to Nottingham University Hospital with a primary fracture of the hip over a period of 8.5 years. The incidence of a second fracture was determined using survival analysis. The mean age-specific incidence rates of primary hip fracture were calculated using census data. The overall incidence of a second fracture was 2.7% at one year and 7.8% at 8.5 years. That of a primary fracture was 50 per 100 000 in women aged 55 to 64 years rising to 3760 in those aged 84 years and over. The incidence of a second fracture in women aged 55 to 64 years was 2344 per 100 000. Patients of this age had a relative risk of 45 (95% confidence interval 13 to 155) for further fracture when compared with the population at risk of a first fracture. The incidence of a second fracture in women aged >
84 years was 2451 per 100 000 (relative risk 0.7, 95% confidence interval 0.5 to 0.9). A similar trend was seen in men. Patients sustaining a primary fracture of the hip between the ages of 55 and 64 years have a much greater risk of further fracture than the normal population, whereas those over 84 years have a similar risk. These findings have important implications for the provision of fracture prevention services in primary and secondary care.