Advertisement for orthosearch.org.uk
Results 1 - 20 of 84
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 60 - 60
1 Apr 2013
Morii H Fukushima K Kamimura N Ooae K Harada M Nishikata K Hanaishi G Matsutani S
Full Access

Background. pelvic fractures in elderly patients often result in poor prognosis due to immobilization associated complications. Thus, the target of the treatment in this patient group is early mobilization in order to reduce the risk of these complications. We report outcomes of 4 cases of pelvic fracture in elderly patients, who were treated with percutaneous screw fixation. Material and method. We examined medical records and images of 4 elderly patients between January 2012 and May 2012 in our center. Mean age of the patients was 88.8 years old (range 86–92 years). The causes of injury were motor vehicle accident in 3 patients, and a fall in 1 patient. Fracture types were ao type a in 1 patient, type b in 2 patients and type c in 1 patient. Mean injury severity score was 25 (10–57). We assessed functional status after the follow-up period using majeed. s. grading score for pelvic fractures. Result. No major complication including sever infection and deep vein thrombosis was observed during the follow-up period. Minor complication observed was screw loosening in 1 case, and screw prominence in another. Functional outcome by majeed. s. score were excellent in 1 case, and fair in 3 cases. The mean period between the operation and the first ride on the wheel chair was 3.5 (2–6) days. Conclusion. Early mobilization significantly affects the prognosis in multiple trauma patients. Percutaneous screw fixation may improve the prognosis in elderly patients with pelvic fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 66 - 71
1 Jan 2008
McQueen MM Gelbke MK Wakefield A Will EM Gaebler C

We randomly allocated 60 consecutive patients with fractures of the waist of the scaphoid to percutaneous fixation with a cannulated Acutrak screw or immobilisation in a cast. The range of movement, the grip and pinch strength, the modified Green/O’Brien functional score, return to work and sports, and radiological evidence of union were evaluated at each follow-up visit. Patients were followed sequentially for one year. Those undergoing percutaneous screw fixation showed a quicker time to union (9.2 weeks vs 13.9 weeks, p < 0.001) than those treated with a cast. There was a trend towards a higher rate of nonunion in the non-operative group, although this was not statistically significant. Patients treated by operation had a more rapid return of function and to sport and full work compared with those managed conservatively. There was a very low complication rate. We recommend that all active patients should be offered percutaneous stabilisation for fractures of the waist of the scaphoid


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 6 - 6
1 Sep 2012
Upadhyay P Beazley J Dunbar M Costa M
Full Access

Introduction. Locking compression plate (LCP) fixation is an established method of treatment of distal third tibial fractures. No biomechanical data exists in the literature regarding their use. Additionally no data exists on the biomechanical advantage of locking screw fixation over non-locking screw fixation for these fractures. In this study the axial and torsional stiffness, axial load to failure and fatigue performance of a 3.5 mm LCP medial distal tibia Synthes plate was evaluated for the stabilisation of distal third tibial fractures. Additionally the performance of the plate in uni and bicortical locked mode as well as non-locked mode was evaluated. Methods. A standardized oblique fracture pattern was created in the tibial metaphysis of 3rd generation composite tibias, 40 mm from the distal end of the tibia (AO 43-A2.3). A 10mm fracture gap was used to model a comminuted metaphyseal fracture. A 3.5 mm medial distal tibia LCP was applied with bi or unicortical locking or bicortical non-locking screws to 5 tibias respectively. All the bio-mechanical tests were performed on a Bose 3510 Electroforce material testing machine. A ramp to load, loading profile was used to determine the static axial and torsional performance of the construct. Fatigue testing simulated a 6 week gradual weight bearing régime with the load increasing every two weeks by 400N until either 250,000 cycles were completed or the construct failed. Results. The non-locked plate demonstrated a significantly higher load to failure than both the bicortical and unicortical locked plates, 683N vs. 575N vs. 483N respectively(p<0.01). The non locked plate also demonstrated significantly higher mean axial stiffness than the bicortical locked plate and unicortical locked plate 632±13 N/mm, 337±12N/mm and 266±6 N/mm respectively (p <0.01). The non locked plate demonstrated the highest torsional stiffness followed by the bi and unicortical locking plates 1.16 ±.08 Nmm vs. 0.79 ± .06 Nmm vs.0.40 ± 0.02 Nmm respectively (p < 0.01). The non locked plate demonstrated higher endurance than the bi and unicortical locking plates over a 6 week simulated fatigue cycle with 1.75mm, 2.10mm and 2.3mm residual displacement at 1600N respectively (p < 0.01). Discussion. This is the first study that has examined the biomechanical properties of the LCP when used for distal third tibial fractures. A review of the literature suggests LCPs outperform dynamic compression plates in osteoporotic bone but demonstrates no clear biomechanical advantage in using a locking construct in non-osteoporotic bone. In our study the non locked construct outperformed the locked constructs in all parameters assessed. We conclude there is no advantage in using a locking construct for distal third tibial fractures in good quality bone


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 418 - 421
1 May 1997
Inoue G Shionoya K

We describe a semi-closed method of Herbert screw fixation for acute fractures of the scaphoid. All 40 patients treated achieved solid union with satisfactory wrist function. This technique gave a significantly shorter time to union and allowed an earlier return to manual labour compared with conservative treatment. There were no complications. Semi-closed insertion requires considerable skill, but produces consistently satisfactory results after minimal exposure of the scaphoid


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 71 - 71
1 Sep 2012
Nesnidal P Stulik J Kryl J
Full Access

Purpose of the Study. At our Department, we prefer surgical treatment of all patients with Type II and III fractures of the dens, regardless of the age, with the exception of non-displaced fractures or perfectly reduced fractures in young patients. Material and Methods. We treated surgically 28 patients 65 years old and older with dens fractures. The group consisted of 13 men and 15 women with a mean age of 77.4 years (range, 65–90 years). According to the type of treatment, anterior srew fixation or posterior C1–C2 fixation, the whole cohort was divided into 2 groups that were subdivided into two age groups of patients 65–74 years old and 75 years old and older. The age group of patients 65–74 years old included 8 patients with a mean age of 68.5 years and the mean age of the age group of patients 75 and more years old was 81 years. The injury was caused in 22 cases by a fall, in 5 by a car accident. Only in 1 case the injury was caused differently. Neurological deficits were found in three patients, all of them Frankel D type. All patients with injury to the dens underwent radiograph examination in the lateral and transoral projections and CT scan including the sagittal and frontal reconstructions of the atlantoaxial complex and in most cases also MRI examination to eliminate injury to the transverse ligament of the atlas. Based on these examinations, the type of injury was determined and method of treatment indicated. Final retrospective evaluation of the patients was carried out at the interval of 12 to 78 months after the primary surgery (mean 31.3 months) taking into account aetiology of the injury, type of injury, neurological finding, method of treatment, union of the dens fracture line or, where appropriate, C1–C2 fusion, stability of the spine and the final outcome. Statistical analysis was based on X2-test. Results. Comparison of the two age groups showed a statistically significant difference in the mortality (p<0.05), with 0% in the younger group and 40% in the older group. In total, mortality within 6 weeks after the injury accounted for 28.6%. Comparison of surgical techniques revealed 21.4% mortality after anterior screw fixation of the dens and 35.7% mortality after posterior instrumented fusion. The difference was statistically insignificant (p>0.05). Of the 20 surviving patients, 11 were treated with anterior screw fixation and 9 with posterior instrumented fusion. In the two groups there was only one case of nonunion of the dens (9.1%) and one fibrous callus in the region of C1–C2 fusion and the fracture line in the dens (11.1%). The difference was again insignificant (p>0.05). Conclusions. Active surgical treatment conduces considerably to the improvement of the quality of life of elderly patients after dens fractures. Surgical technique should be tailored to the patient's general condition, and osteoporosis and degenerative changes of the spine in particular. Mortality is influenced by the patient's age rather than by the surgical technique used. Elderly patients with a neurological deficit mostly die of associated diseases regardless of the method of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1520 - 1523
1 Nov 2005
Attias N Lindsey RW Starr AJ Borer D Bridges K Hipp JA

We created virtual three-dimensional reconstruction models from computed tomography scans obtained from patients with acetabular fractures. Virtual cylindrical implants were placed intraosseously in the anterior column, the posterior column and across the dome of the acetabulum. The maximum diameter which was entirely contained within the bone was determined for each position of the screw. In the same model, the cross-sectional diameters of the columns were measured and compared to the maximum diameter of the corresponding virtual implant.

We found that the mean maximum diameter of virtual implant accommodated by the anterior columns was 6.4 mm and that the smallest diameter of the columns was larger than the maximum diameter of the equivalent virtual implant.

This study suggests that the size of the screw used for percutaneous fixation of acetabular fractures should not be based solely on the measurement of cross-sectional diameter and that virtual three-dimensional reconstructions might be useful in pre-operative planning.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 59 - 59
1 Sep 2012
Demura S Kawahara N Murakami H Fujimaki Y Kato S Okamoto Y Hayashi H Inoue K Tsuchiya H
Full Access

Introduction

Correction and arthrodesis for cervical kyphosis associated with atetoid cerebral palsy has been considered to be difficult because of their involuntary neck movements and severe deformity. The aim of this study is to evaluate the surgical outcome of midline T-saw laminoplasty and posterior arthrodesis using pedicle screws.

Methods

15 patients were retrospectively reviewed. There were 6 women and 9 men, with a mean age 52.9 years (range 31–71 years). Mean follow-up period was 43 months (range 24–84 months). For clinical evaluation, the Japanese Orthopaedic Association (JOA) score and Barthel index (BI) which shows independence in ADL were used. For radiographic evaluation, change of C2–C7 Cobb angle of sagittal alignment, adjacent segment instability after the surgery were evaluated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 555 - 555
1 Sep 2012
Starks I Frost A Wall P Lim J
Full Access

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability.

The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7.

A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 411 - 418
1 Apr 2003
Ziran BH Smith WR Towers J Morgan SJ

Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated.

A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of iliosacral screws is a safe, feasible, and cost-effective alternative to radiologically-guided placement in the operating theatre in selected patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 31 - 31
1 Sep 2012
Gjertsen J Vinje T Fevang J Lie SA Furnes O Havelin LI Engesaeter LB
Full Access

Introduction

Displaced femoral neck fractures in elderly are normally treated with 2 screws/pins (IF) or bipolar hemiarthroplasty (HA). The aim of this study was to compare IF and HA as treatment for displaced femoral neck fractures using reoperations and functional result (patient satisfaction, pain, and quality of life) as outcome.

Material and Methods

From January 2005 all hip fractures in Norway are reported to the Norwegian Hip Fracture Register. At 4, 12, and 36 months postoperatively a questionnaire assessing satisfaction (VAS 0-100), pain (VAS 0-100), and quality of life (EQ-5D) is sent to the patients. To ensure more than 3 years follow-up, only patients operated in 2005 were included in the present study. Consequently 1,968 patients over 70 years of age operated with IF (n = 958) or HA (n = 1,010) due to displaced femoral neck fractures were included in the analyses on reoperations. Of these, 280 patients responded to all questionnaires and were included in the analyses on functional results (IF: n = 135, HA: n = 145). The patients remained in the same treatment group according to the intention-to-treat principle.


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 658 - 664
1 May 2011
Karantana A Boulton C Bouliotis G Shu KSS Scammell BE Moran CG

We examined prospectively collected data from 6782 consecutive hip fractures and identified 327 fractures in 315 women aged ≤65 years. We report on their demographic characteristics, treatment and outcome and compare them with a cohort of 4810 hip fractures in 4542 women aged > 65 years. The first significant increase in age-related incidence of hip fracture was at 45, rather than 50, which is when screening by the osteoporosis service starts in most health areas. Hip fractures in younger women are sustained by a population at risk as a result of underlying disease. Mortality of younger women with hip fracture was 46 times the background mortality of the female population. Smoking had a strong influence on the relative risk of ‘early’ (≤ 65 years of age) fracture. Lag screw fixation was the most common method of operative treatment. General complication rates were low, as were re-operation rates for cemented prostheses. Kaplan-Meier implant survivorship of displaced intracapsular fractures treated by reduction and lag screw fixation was 71% (95% confidence interval 56 to 81) at five years. The best form of treatment remains controversial


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 26 - 26
1 Sep 2012
Gjertsen J Fevang J Vinje T Matre K Engesaeter LB
Full Access

Introduction. Undisplaced femoral neck fractures have been given little attention in the literature. By using data from the Norwegian Hip Fracture Register, this study investigates risk for reoperation and the clinical results, including pain, patient satisfaction, and quality of life, after undisplaced femoral neck fractures in elderly patients. Material and Methods. Data on 4,468 patients over 70 years of age with undisplaced femoral neck fractures operated with internal fixation (IF) were compared to 10,289 patients with displaced femoral neck fractures treated with IF (n = 3,389) or bipolar hemiarthroplasty (n = 6,900). The evaluation was based on number of reported reoperations and patients' assessment (visual analogue scales concerning pain (0–100) and patient satisfaction (0–100), and quality of life (EQ-5D)) four and twelve months postoperatively. The patients were followed for 0–1 year. The Cox multiple regression model was used to construct adjusted survival curves. Subanalyses were performed on undisplaced femoral neck fractures to investigate different risk factors for reoperation. Results. The survival rate of implants after one year was 89% after screw fixation for undisplaced fractures, 79% after screw fixation for displaced fractures, and 97% after hemiarthroplasty for displaced fractures (Kaplan Meier). Adjusted for age, sex, ASA-classification, and cognitive function the displaced fractures operated with internal fixation had higher risk of reoperation compared to the undisplaced fractures operated with internal fixation (RR 1.92, 95% CI: 1.69–2.17; p<0.001). The displaced fractures operated with hemiarthroplasty had a lower risk of reoperation compared to the undisplaced fractures (RR 0.32, 95%CI: 0.27–0.38; p<0.001). Patients treated with IF for undisplaced fractures were more satisfied, had less pain, and higher quality of life compared to patients treated with IF after displaced fractures (p<0.05). The patients treated with bipolar hemiarthroplasty for displaced fractures had, however, the least pain, were most satisfied, and reported the highest quality of life. Discussion and Conclusion. The clinical outcome after undisplaced femoral neck fractures treated with screw fixation was better than the results of screw fixation for displaced fractures, but poorer than the clinical results for patients with displaced femoral neck fractures operated with a bipolar hemiarthroplasty. However, the differences in clinical outcome were smaller than what is considered to be of clinical importance. One year postoperatively screw osteosynthesis of undisplaced femoral neck fractures in elderly patients still seems to be a good alternative


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_18 | Pages 6 - 6
1 Dec 2018
Semple E Campbell D Maclean J
Full Access

Historically avoidance of avascular necrosis (AVN) has been the primary objective in the management of an acute unstable slipped upper femoral epiphysis (SUFE). When achieved through pinning in situ it was invariably associated with significant malunion. With increasing appreciation of the consequences of femoroacetabular impingement, modern techniques aim to correct deformity and avoid AVN. Exactly what constitutes an acute unstable SUFE is a source of debate but should represent 5–10% of all cases. This audit reviewed cases over the past 25 years treated in one region. Of 89 patients with 113 slips, 21 hips were recorded as unstable. During this period the management has evolved from closed reduction and stabilization through pinning in situ, to open reduction. Radiographic outcomes following these three treatment methods were compared with record of any subsequent surgery in the form of osteotomy or total hip arthroplasty. Currently the lowest reported incidence of AVN in patients with an acute unstable slip is associated with the Parsch technique which combines open arthrotomy, digital reduction and screw fixation. Early outcomes with this technique are in accordance with those reported in the literature and represents a significant improvement in outcome when compared to earlier techniques used in the management of the severe unstable SUFE


Bone & Joint Open
Vol. 4, Issue 9 | Pages 676 - 681
5 Sep 2023
Tabu I Goh EL Appelbe D Parsons N Lekamwasam S Lee J Amphansap T Pandey D Costa M

Aims

The aim of this study was to describe the current pathways of care for patients with a fracture of the hip in five low- and middle-income countries (LMIC) in South Asia (Nepal and Sri Lanka) and Southeast Asia (Malaysia, Thailand, and the Philippines).

Methods

The World Health Organization Service Availability and Readiness Assessment tool was used to collect data on the care of hip fractures in Malaysia, Thailand, the Philippines, Sri Lanka, and Nepal. Respondents were asked to provide details about the current pathway of care for patients with hip fracture, including pre-hospital transport, time to admission, time to surgery, and time to weightbearing, along with healthcare professionals involved at different stages of care, information on discharge, and patient follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims

To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial.

Methods

The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 566 - 572
18 Jul 2022
Oliver WM Molyneux SG White TO Clement ND Duckworth AD

Aims

The primary aim was to estimate the cost-effectiveness of routine operative fixation for all patients with humeral shaft fractures. The secondary aim was to estimate the health economic implications of using a Radiographic Union Score for HUmeral fractures (RUSHU) of < 8 to facilitate selective fixation for patients at risk of nonunion.

Methods

From 2008 to 2017, 215 patients (mean age 57 yrs (17 to 18), 61% female (n = 130/215)) with a nonoperatively managed humeral diaphyseal fracture were retrospectively identified. Union was achieved in 77% (n = 165/215) after initial nonoperative management, with 23% (n = 50/215) uniting after surgery for nonunion. The EuroQol five-dimension three-level health index (EQ-5D-3L) was obtained via postal survey. Multiple regression was used to determine the independent influence of patient, injury, and management factors upon the EQ-5D-3L. An incremental cost-effectiveness ratio (ICER) of < £20,000 per quality-adjusted life-year (QALY) gained was considered cost-effective.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 12 - 12
1 May 2013
Tsang S Aitken S Gorlay R Silverwood R Biant L
Full Access

Proximal femoral fractures remain the most common reason for admission to hospital following orthopaedic injury, with an annual cost of £1.7 billion to the National Health Service and social care services. Fragility fractures of the hip in the elderly are a substantial cause of mortality and morbidity. Revision surgery for any cause carries a higher morbidity, mortality, healthcare- and social economic burden. Which patients suffer failed surgery and the reasons for failure have not been established. The aim of this study was to determine which patients are at risk of failed proximal femoral fracture surgery, the mechanism and cause fo failed surgery and modifiable patient factors associated with failure of hip fracture surgery. From prospectively collected data of 795 consecutive proximal femoral fractures admitted between July 2007 and July 2008, all peri-operative and post-operative complications were identified. 55 (6.9%) patients were found to have developed a surgical complication requiring further intervention. Risk factors included younger age (p=0.01), smoking (p=0.01) and cannulated screw fixation (p<0.01). Cannulated screw fixation was associated with a 30.9% complication rate. Mechanical cause was the most common reason for cannulated screw failure. Hip hemiarthroplasty most commonly failed by infective causes. Inter-trochanteric and subtrochanteric fracture fixation had very low failure rates. Surgical complication was not found to be associated with an increased mortality but a post-operative medical complication (21.8%) was associated with higher rate of mortality at 4-years (78.5%) and shorter time to mortality. (Median time 0.16 years (95% CI 0.00–0.33)


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1182 - 1189
1 Oct 2024
Nisar S Lamb J Johansen A West R Pandit H

Aims

To determine if patient ethnicity among patients with a hip fracture influences the type of fracture, surgical care, and outcome.

Methods

This was an observational cohort study using a linked dataset combining data from the National Hip Fracture Database and Hospital Episode Statistics in England and Wales. Patients’ odds of dying at one year were modelled using logistic regression with adjustment for ethnicity and clinically relevant covariates.