Results 1 - 20 of 26
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 66 - 66
17 Nov 2023
Rajab A Ponsworno K Keehan R Ahmad R
Full Access

Abstract. Background. Post operative radiographs following total joint arthroplasty are requested as part of routine follow up in many institutions. These studies have a significant cost to the local departments, in terms of financial and clinic resources, however, previous research has suggested they may not alter the course of the patients treatment. The purpose of this study was to assess the significance of elective post operative radiographs on changes in management of patients who underwent total joint arthroplasty. Method. All patients who underwent total knee arthroplasty and total hip arthroplasty at a District General Hospital from 2019 to 2020 were included. Data was collected retrospectively from medical records and radiograph requests. Alterations to clinical management based on radiographic findings were reviewed in clinic letters. Results. A total of 227 Total joint arthroplasty were retrieved. With 111(49%) total hip arthroplasty and 116 (51%) total knee arthroplasty. 54 were excluded due to having no clinical follow up and 173 met inclusion criteria. 56 (32%) had their post operative elective radiograph, while 93 (53.8%) patients had none. There were no abnormalities detected from the elective radiographs and none of the patients returned to the theatre. 24 patients (13%) presented with symptoms and had non-elective radiographs, 16 (67%) did not have any interventions and 8 (4.6%) required intervention and were taken to theatre. Discussion: Not performing these radiographs saves time, cost, and prevents unnecessary radiation exposure. In our institution, a 2-view joint radiograph costs £29 and takes roughly 15 minutes. This does not include indirect costs of additional clinic time and patient waiting time. In the larger context, the cost associated with elective radiographs is significant and our data suggests that routine post-operative radiographs are not beneficial as part of standard post-operative protocol for asymptomatic patients. However, performing imaging remains beneficial for patients who re-present with symptoms. Conclusion. Routine elective post-operative joint radiographs did not detect any true abnormalities. Information from elective radiographs has no clinical significance and did not change management. Therefore, this study recommends that there is no rationale requesting elective post-operative joint radiographs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 54 - 54
17 Nov 2023
Bishop M Zaffagnini S Grassi A Fabbro GD Smyrl G Roberts S MacLeod A
Full Access

Abstract. Background. Distal femoral osteotomy is an established successful procedure which can delay the progression of arthritis and the need for knee arthroplasty. The surgery, however, is complex and lengthy and consequently it is generally the preserve of highly experienced specialists and thus not widely offered. Patient specific instrumentation is known to reduce procedural complexity, time, and surgeons’ anxiety levels. 1. in proximal tibial osteotomy procedures. This study evaluated a novel patient specific distal femoral osteotomy procedure (Orthoscape, Bath, UK) which aimed to use custom-made implants and instrumentation to provide a precision correction while also simplifying the procedure so that more surgeons would be comfortable offering the procedure. Presenting problem. Three patients (n=3) with early-stage knee arthritis presented with valgus malalignment, the source of which was predominantly located within the distal femur, rather than intraarticular. Using conventional techniques and instrumentation, distal femoral knee osteotomy cases typically require 1.5–2 hours surgery time. The use of bi-planar osteotomy cuts have been shown to improve intraoperative stability as well as bone healing times. 2. This normally also increases surgical complexity; however, multiple cutting slots can be easily incorporated into patient specific instrumentation. Clinical management. All three cases were treated at a high-volume tertiary referral centre (Istituto Ortopedico Rizzoli, Bologna) using medial closing wedge distal femoral knee osteotomies by a team experienced in using patient specific osteotomy systems. 3. Virtual surgical planning was conducted using CT-scans and long-leg weight-bearing x-rays (Orthoscape, Bath, UK). Patient specific surgical guides and custom-made locking plates were design for each case. The guides were designed to allow temporary positioning, drilling and bi-planar saw-cutting. The drills were positioned such that the drills above and below the osteotomy became parallel on closing following osteotomy wedge removal. This gave reassurance of the achieved correction allowed the plate to be located precisely over the drills. All screw lengths were pre-measured. Discussion. The surgical time reduced to approximately 30 minutes by the third procedure. It was evident that surgical time was saved because no intraoperative screw length measurements were required, relatively few x-rays were used to confirm the position of the surgical guide, and the use of custom instrumentation significantly reduced the surgical inventory. The reduced invasiveness and ease of surgery may contribute to faster patient recovery compared to conventional techniques. The final post-operative alignment was within 1° of the planned alignment in all cases. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 5 - 5
1 Dec 2022
Lombardo MDM Mangiavini L Peretti GM
Full Access

Menisci are crucial structures for knee homeostasis: they provide increase of congruence between the articular surfaces of the distal femur and tibial plateau, bear loading, shock absorption, lubrication, and proprioception. After a meniscal lesion, the golden rule, now, is to save as much meniscus as possible: only the meniscus tissue which is identified as unrepairable should be excised and meniscal sutures find more and more indications. Several different methods have been proposed to improve meniscal healing. They include very basic techniques, such as needling, abrasion, trephination and gluing, or more complex methods, such as synovial flaps, meniscal wrapping, or the application of fibrin clots. Basic research of meniscal substitutes has also become very active in the last decades. The features needed for a meniscal scaffold are: promotion of cell migration, it should be biomimetic and biocompatible, it should resist forces applied and transmitted by the knee, it should slowly biodegrade and should be easy to handle and implant. Several materials have been tested, that can be divided into synthetic and biological. The first have the advantage to be manufactured with the desired shapes and sizes and with precise porosity dimension and biomechanical characteristics. To date, the most common polymers are polylactic acid (PGA); poly-(L)-lactic acid (PLLA); poly- (lactic-co-glycolic acid) (PLGA); polyurethane (PU); polyester carbon and polycaprolactone (PCL). The possible complications, more common in synthetic than natural polymers are poor cell adhesion and the possibility of developing a foreign body reaction or aseptic inflammation, leading to alter the joint architecture and consequently to worsen the functional outcomes. The biological materials that have been used over time are the periosteal tissue, the perichondrium, the small intestine submucosa (SIS), acellular porcine meniscal tissue, bacterial cellulose. Although these have a very high biocompatibility, some components are not suitable for tissue engineering as their conformation and mechanical properties cannot be modified. Collagen or proteoglycans are excellent candidates for meniscal engineering, as they maintain a high biocompatibility, they allow for the modification of the porosity texture and size and the adaptation to the patient meniscus shape. On the other hand, they have poor biomechanical characteristics and a more rapid degradation rate, compared to others, which could interfere with the complete replacement by the host tissue. An interesting alternative is represented by hydrogel scaffolds. Their semi-liquid nature allows for the generation of scaffolds with very precise geometries obtained from diagnostic images (i.e. MRI). Promising results have been reported with alginate and polyvinyl alcohol (PVA). Furthermore, hydrogel scaffolds can be enriched with growth factors, platelet-rich plasma (PRP) and Bone Marrow Aspirate Concentrate (BMAC). In recent years, several researchers have developed meniscal scaffolds combining different biomaterials, to optimize the mechanical and biological characteristics of each polymer. For example, biological polymers such as chitosan, collagen and gelatin allow for excellent cellular interactions, on the contrary synthetic polymers guarantee better biomechanical properties and greater reliability in the degradation time. Three-dimensional (3D) printing is a very interesting method for meniscus repair because it allows for a patient-specific customization of the scaffolds. The optimal scaffold should be characterized by many biophysical and biochemical properties as well as bioactivity to ensure an ECM-like microenvironment for cell survival and differentiation and restoration of the anatomical and mechanical properties of the native meniscus. The new technological advances in recent years, such as 3D bioprinting and mesenchymal stem cells management will probably lead to an acceleration in the design, development, and validation of new and effective meniscal substitutes


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 52 - 52
1 Dec 2021
Wang J Hall T Musbahi O Jones G van Arkel R
Full Access

Abstract. Objectives. Knee alignment affects both the development and surgical treatment of knee osteoarthritis. Automating femorotibial angle (FTA) and hip-knee-ankle angle (HKA) measurement from radiographs could improve reliability and save time. Further, if the gold-standard HKA from full-limb radiographs could be accurately predicted from knee-only radiographs then the need for more expensive equipment and radiation exposure could be reduced. The aim of this research is to assess if deep learning methods can predict FTA and HKA angle from posteroanterior (PA) knee radiographs. Methods. Convolutional neural networks with densely connected final layers were trained to analyse PA knee radiographs from the Osteoarthritis Initiative (OAI) database with corresponding angle measurements. The FTA dataset with 6149 radiographs and HKA dataset with 2351 radiographs were split into training, validation and test datasets in a 70:15:15 ratio. Separate models were learnt for the prediction of FTA and HKA, which were trained using mean squared error as a loss function. Heat maps were used to identify the anatomical features within each image that most contributed to the predicted angles. Results. FTA could be predicted with errors less than 3° for 99.8% of images, and less than 1° for 89.5%. HKA prediction was less accurate than FTA but still high: 95.7% within 3°, and 68.0 % within 1°. Heat maps for both models were generally concentrated on the knee anatomy and could prove a valuable tool for assessing prediction reliability in clinical application. Conclusions. Deep learning techniques could enable fast, reliable and accurate predictions of both FTA and HKA from plain knee radiographs. This could lead to cost savings for healthcare providers and reduced radiation exposure for patients


Bone & Joint Research
Vol. 6, Issue 5 | Pages 259 - 269
1 May 2017
McKirdy A Imbuldeniya AM

Objectives. To assess the clinical and cost-effectiveness of a virtual fracture clinic (VFC) model, and supplement the literature regarding this service as recommended by The National Institute for Health and Care Excellence (NICE) and the British Orthopaedic Association (BOA). Methods. This was a retrospective study including all patients (17 116) referred to fracture clinics in a London District General Hospital from May 2013 to April 2016, using hospital-level data. We used interrupted time series analysis with segmented regression, and direct before-and-after comparison, to study the impact of VFCs introduced in December 2014 on six clinical parameters and on local Clinical Commissioning Group (CCG) spend. Student’s t-tests were used for direct comparison, whilst segmented regression was employed for projection analysis. Results. There were statistically significant reductions in numbers of new patients seen face-to-face (140.4, . sd. 39.6 versus 461.6, . sd. 61.63, p < 0.0001), days to first orthopaedic review (5.2, . sd. 0.66 versus 10.9, . sd. 1.5, p < 0.0001), discharges (33.5, . sd. 3.66 versus 129.2, . sd. 7.36, p < 0.0001) and non-attendees (14.82, . sd. 1.48 versus 60.47, . sd. 2.68, p < 0.0001), in addition to a statistically significant increase in number of patients seen within 72-hours (46.4% 3873 of 8345 versus 5.1% 447 of 8771, p < 0.0001). There was a non-significant increase in consultation time of 1 minute 9 seconds (14 minutes 53 seconds . sd. 106 seconds versus 13 minutes 44 seconds . sd. 128 seconds, p = 0.0878). VFC saved the local CCG £67 385.67 in the first year and is set to save £129 885.67 annually thereafter. Conclusions. We have shown VFCs are clinically and cost-effective, with improvement across several clinical performance parameters and substantial financial savings for CCGs. To our knowledge this is the largest study addressing clinical practice implications of VFCs in England, using robust methodology to adjust for pre-existing trends. Further studies are required to appreciate whether our results are reproducible with local variations in the VFC model and payment tariffs. Cite this article: A. McKirdy, A. M. Imbuldeniya. The clinical and cost effectiveness of a virtual fracture clinic service: An interrupted time series analysis and before-and-after comparison. Bone Joint Res 2017;6:–269. DOI: 10.1302/2046-3758.65.BJR-2017-0330.R1


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 67 - 67
1 Dec 2021
MacLeod A Belvedere C Fabbro GD Grassi A Nervuti G Leardini A Casonato A Zaffagnini S Gill H
Full Access

Abstract. Objectives. High tibial osteotomy for knee realignment is effective at relieving symptoms of knee osteoarthritis but the operation is surgically challenging. A new personalised treatment with simpler surgery using pre-operatively planned measurements from computed tomography (CT) imaging and 3D-printed implants and instrumentation has been designed and is undergoing clinical trial. The aim of this study was to evaluate the early clinical results of a preliminary pilot study evaluating the safety of this new personalised treatment. Methods. The single-centre prospective clinical trial is ongoing (IRCCS Istituto Ortopedico Rizzoli; IRB-0013355; ClinicalTrials.gov NCT04574570), with recruitment completed and all patients having received the novel custom surgical treatment. To preserve the completeness of the trial reporting, only surgical aspects were evaluated in the present study. Specifically, the length of the implanted osteosynthesis screws was considered, being determined pre-operatively eliminating intraoperative measurements, and examined post-operatively (n=7) using CT image processing (ScanIP, Synopsys) and surface distance mapping. The surgical time, patient discharge date and ease of wound closure were recorded for all patients (n=25). Results. Over the study period the average surgical time (skin incision to suture) reduced from 54 to 31 minutes (range: 17–62, n=25). It was noted that wound closure was easier than the conventional surgery due to the lower profile of the implant. Over seventy percent of patients were discharged day 2 post-op. The position, orientation and length of all screws matched the pre-operative configuration to within approximately 1mm. Conclusions. The early trial results are promising from a clinical perspective. It was evident that surgical time was saved because no intraoperative screw length measurements were required, and the use of custom instrumentation significantly reduced the surgical inventory. The reduced invasiveness and ease of surgery may contribute to faster patient recovery compared to conventional techniques. The full trial results will be reported later this year. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 46 - 46
1 Mar 2021
Valverde J Kabariti R Smith J Kelly M Murray J
Full Access

Pre-operative anaemia can present in up to 30% of elective arthroplasty patients. The presence of anaemia increases the risk of requiring blood transfusion post-operatively as well as acts as an independent risk factor for poor outcome such as prosthetic joint infection. Recent international consensus on this topic has recommended a specific care pathway for screening patients with pre-operative anaemia using a simple bedside Heaemacue finger-prick test to detect in a simple and cost-effective manner, and then allow treatment of preoperative anaemia. This pathway was therefore incorporated in our trust. This was a retrospective study done at a single tertiary-referral arthroplasty centre. Our data collection included the Heamacue test results and formal haemoglobin levels if they were performed as well as compliance and costs of each of the tests for patients listed for an elective shoulder, hip and knee arthroplasty between September and December 2018. Medical records and demographics were also collected for these patients for subgroup analysis. Our exclusion criteria comprised patients listed for revision arthroplasty surgery. 87 patients were included in this study. Our compliance rate was 15%. The mean difference between a Haemacue test and a formal FBC result was only 17.6g/L suggesting that it has a reasonably high accuracy. With regards to costs, we found that a Haemacue test costs £2, compared to £7.50 for a full blood count and Haematinics combined. This gave an overall cost saving of £5.50 per patient. Extrapolation of this date locally for 2017 at our hospital, where 1575 primary joint arthroplasties were done, a cost saving of £8,662.5 could have been achieved. Within the UK using data extrapolated from the National Joint Registry a total of £1,102,205.5 (1,221,894 Euros) could have been saved. The use of a single, Haemacue test to screen for pre-operative anaemia in elective arthroplasty patients is more cost effective compared to a formal full count and haematinics tests. However, we found that compliance with the care pathway is variable due to system limitations. This may be addressed through implementing changes to our electronic system in which patients are booked for surgery. We also noted a significant cost reduction if this pathway were to be used Nation-wide. Thus, we encourage other centres to consider the use of the Haemacue test pre-operatively in elective arthroplasty instead of formal full blood counts at the time of decision to treat with arthroplasty; this allows sufficient time for correction of pre-operative anaemia thus improving patient outcomes from arthroplasty


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 123 - 123
1 Mar 2021
Jelsma J Schotanus M van Kuijk S Buil I Heyligers I Grimm B
Full Access

Hip resurfacing arthroplasty (HRA) became a popular procedure in the early 90s because of the improved wear characteristic, preserving nature of the procedure and the optimal stability and range of motion. Concerns raised since 2004 when metal ions were seen in blood and urine of patients with a MoM implant. Design of the prosthesis, acetabular component malpositioning, contact-patch-to-rim distance (CPR) and a reduced joint size all seem to play a role in elevated metal ion concentrations. Little is known about the influence of physical activity (PA) on metal ion concentrations. Implant wear is thought to be a function of use and thus of patient activity levels. Wear of polyethylene acetabular bearings was positively correlated with patient's activity in previous studies. It is hypothesized that daily habitual physical activity of patients with a unilateral resurfacing prosthesis, measured by an activity monitor, is associated with habitual physical activity. A prospective, explorative study was conducted. Only patients with a unilateral hip resurfacing prosthesis and a follow-up of 10 ± 1 years were included. Metal ion concentrations were determined using ICP-MS. Habitual physical activity of subjects was measured in daily living using an acceleration-based activity monitor. Outcome consisted of quantitative and qualitative activity parameters. In total, 16 patients were included. 12 males (75%) and 4 females (25%) with a median age at surgery of 55.5 ± 9.7 years [43.0 – 67.9] and median follow-up of 9.9 ± 1.0 years [9.1 – 10.9]. The median cobalt and chromium ion concentrations were 25 ± 13 and 38 ± 28 nmol/L. A significant relationship, when adjusting for age at surgery, BMI, cup size and cup inclination, between sit-stand transfers (p = .034) and high intensity peaks (p = .001) with cobalt ion concentrations were found (linear regression analysis). This study showed that a high number of sit-stand transfers and a high number of high intensity peaks is significantly correlated with high metal ion concentrations, but results should be interpreted with care. For patients it seems save to engage in activities with low intensity peaks like walking or cycling without triggering critical wear or metal ions being able to achieve important general health benefits and quality of life, although the quality (high intensity peaks) of physical activity and behaviour of patients (sit-stand-transfers) seem to influence metal ion concentrations


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 25 - 25
1 Mar 2021
Sephton B Edwards TC Bakhshayesh P Nathwani D
Full Access

In recent years, reduction in the length of stay in patients undergoing UKA has gained considerable interest. This has led to development of ‘fast-track' and even day-case protocols aimed at decreasing length of stay (LOS), enhancing post-operative recovery and decreasing post-operative morbidity. One potential barrier to faster discharge and patient recovery is the need for post-operative haemoglobin checks and allogenic blood transfusion; which has been shown to increase LOS. Allogenic blood transfusion itself is not without risk, including immunological reactions, transfusion associated lung injury, infection and transmission of disease, thus reducing blood loss and the need for transfusion is imperative. Currently there is a knowledge gap regarding post-operative transfusion need and blood loss following UKA. We aimed to investigate blood loss and transfusion rates following UKA. Our primary aim was to evaluate the extent of post-operative transfusion need following UKA and identify which patients are at higher risk of needing transfusion. Following institutional approval, a retrospective analysis of all patients undergoing unicompartmental knee arthroplasty (UKA) at our level one academic university hospital was conducted. Operative records of all patients undergoing primary UKA were reviewed between March 2016 and March 2019. Patients' pre-operative haemoglobin and haematocrit, BMI, co-morbidities, application of tourniquet, tourniquet time, administration of Tranexamic Acid, need for post-operative blood transfusion, hospital length of stay, complications and re-admission were all recorded. Blood loss was estimated using the post-operative haematocrit. A total number of 155 patients were included. There were 70 females (45%) and 85 males (55%). The mean age was 66±10 years. Median pre-op blood volume was 4700mls (IQR; 4200–5100). Median blood loss was 600 mls (IQR; 400–830). Mean pre-op Haemoglobin was 135±14g/L and mean post-op Haemoglobin was 122±13g/L. No patient had a post-op Haemoglobin under 80g/L (Range 93–154). No patients in our study needed transfusion. A further comparison group of high-blood loss and low-blood loss patients was included in analysis. High-blood loss patients were defined as those losing greater than 20% of their pre-operative blood volume whilst low-blood loss patients were defined as those losing ≤20% of their blood volume. Results of these groups are presented in Table 3. No significance was found between the two groups in patient's demographics and in terms of intra-operative factors including TXA usage (p=0.68) and tourniquet time (p=0.99). There was no difference in terms of post-operative complications (p=1.0), length of stay (p=0.36) or readmission rates (p=0.59). The results of our study indicated that post-operative haemoglobin and haematocrit check proved unnecessary in all of our patients and could have been omitted from post-operative routines. We conclude that routine post UKA check of haemoglobin and haematocrit can be avoided and be saved for special circumstances depending on patient's physiology


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 114 - 114
1 Dec 2020
Cullu E Olgun H Tataroğlu C Ozgezmez FT Sarıerler M
Full Access

Thermal osteonecrosis is a side effect when used Kirschner (K) wires and drills in orthopaedic surgeries. This osteonecrosis may endanger the fixation. Orthopaedic surgeons sometimes have to use unsharpened K-wires in emergent surgery. The thermal effect of used and unsharpened K wire is ambiguous to the bone. This experimental study aims to assess the thermal osteonecrosis while drilling bone with three different types of K-wires especially a previously used unsharpened wire and its thermographic measurements correlation. Two different speeds of rotation were chosen to investigate the effect of speed on thermal necrosis to the bone. A total of 16 New Zealand white rabbits weighing a mean of 2.90 kg (2.70 – 3.30 kg) were used. All rabbits were operated under general anaesthesia in a sterile operating room. Firstly, 4 cm longitudinal lateral approach was used to the right femur and then the femur was drilled with 1.0 mm trochar tip, spade tip and previously used unsharpened K-wires and 1.0 mm drill bit at 1450 rpm speed. Left femur was drilled with same three type K-wires and drill bit at 330 rpm speed. One cm distance was left among four penetrations on the femur. The thermal changes were recorded by Flir® E6 Thermal Camera from 50 cm distance and 30-degree angle. Thermographic measurements saved for every drilling process and recorded for the highest temperature (°C) during the drilling. All subjects were sacrificed post-operatively on the eighth day and specimens were prepared for the histological examination. The results of osteonecrosis assessment score and thermographic correlation were evaluated statistically. Histological specimens were evaluated by the scoring of osteonecrosis, osteoblastic activity, haemorrhage, microfracture and inflammation. Results were graded semi-quantitatively as none, moderate or severe for osteonecrosis, haemorrhage and inflammation. The microfracture and osteoblastic activity were evaluated as present or absent. There was no meaningful correlation between osteonecrosis and the drilling speed (p=0.108). There was less microfracture zone which was drilled with trochar tip K-wires at 1450 rpm speed (p=0.017). And the drilling temperature of trochar tip K-wires was higher than the others(p=0.001). Despite this evaluation, osteonecrosis zone of spade and unsharpened tip K-wires were more than trochar tip K-wires (p=0.039). The drill bit at 330 rpm caused the least osteonecrosis and haemorrhage and respectfully the lowest drilling temperature (p=0,001). The osteoblastic activity shows no difference between the groups. (p=0,122; 0,636;0.289). On the contrary to the literature, our experiment showed that there is no meaningful correlation between osteonecrosis score and temperature produced by drilling. The histological assessment showed the osteonecrosis during short drilling time but, not clarify the relation with drilling temperature. Eventually, the osteonecrosis showed a positive correlation with drilling time independently of drilling temperature at 330 rpm. (p=0,042) These results show that we need more studies to understand about osteonecrosis and its relationship with drilling heat temperature. Trochar tip K-wires creates higher drilling temperature but less osteonecrosis than a spade and unsharpened cut tip K-wires. Using unsharpened tip K-wire causes more osteonecrosis. Previously used and, unsharpened K-wires should be discarded


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 24 - 24
1 Nov 2018
Mantovani D
Full Access

Over the last 50 years, biomaterials, prostheses and implants saved and prolonged the life of millions of humans around the globe. The main clinical complications for current biomaterials and artificial organs still reside in an interfacial mismatch between the synthetic surface and the natural living tissue surrounding it. Today, nanotechnology, nanomaterials and surface modifications provides a new insight to the current problem of biomaterial complications, and even allows us to envisage strategies for the organ shortage. Advanced tools and new paths towards the development of functional solutions for cardiovascular clinical applications are now available. In this talk, the potential of nanostructured metallic degradable metals to provide innovative solutions at medium term for the cardiovascular field will be depicted. Focus will be on Fe-based biodegradable metals with exceptional resistance, ductility and elasticity, for pushing innovative vascular applications. The intrinsic goal of this talk is to present an extremely personal look at how biodegradable metals can impact materials, surfaces and interfaces, and how the resulting unique properties allowed biomedical functional applications to progress, from their introduction, to the promising future that biodegradable metals may or may not hold for improving the quality of the life of millions worldwide


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 13 - 13
1 Jul 2014
Emohare O Cagan A Dittmer A Morgan R Switzer J Polly D
Full Access

Summary Statement. Using abdominal CT scans to evaluate bone mineral density following acute fractures of the thoracic and lumbar spine demonstrates significant levels of osteoporosis in older patients; this approach may help save on time and resources, and reduce unnecessary radiation exposure. Introduction. While a reduction in bone mineral density (BMD) is associated with aging, relatively few patients have formal dual-energy X-ray absorptiometry (DXA) to quantify the magnitude of bone loss, as they age. This loss of bone may predispose to fractures. Recent data, which correlates mean Hounsfield units (HU) in an area of the L1 vertebra with BMD, now makes it possible to screen for osteoporosis using incidental abdominal Computed Tomography (CT) scans to measure bone density. This innovation has the potential to reduce both cost and radiation exposure, and also make it easier to identify patients who may be at risk. The aims of this study were to evaluate the utility of this approach in patients with acute thoracic and lumbar spine fractures and to evaluate the impact of aging on BMD, using CT screening. Patients & Methods. Following institutional review board approval, we performed a retrospective study of patients who presented to a level I trauma center with acute fractures of the thoracic and lumbar spine between 2010 and 2013; patients also had to have had an abdominal (or L1) CT scan either during the admission or in the 6 months before or after their injury. Using a picture archiving and communication (PACS) system, we generated regions of interest (ROI) of similar size in the body of L1 (excluding the cortex) and computed mean values for HU. Values derived were compared against threshold values which differentiate between osteoporosis and osteopenia - for specificity of 90%, a threshold of 110 was set; for balanced sensitivity and specificity, a threshold of <135 HU was set and for 90% sensitivity a threshold of <160 HU was set. A student's t test was used to compare the age stratified mean HU (younger than 65yrs; 65yrs and older), while Fisher's exact test was used to perform aged stratified comparisons between the proportions of patients above and below the thresholds outlined (in each of the three threshold groups). Results. A total of 124 patients were evaluated, with 74 having thoracic and 50 having lumbar fractures. Among those with thoracic fractures, there were 33patients in the younger cohort, who also had a mean BMD of 196.51HU and 41 in the older cohort, who had mean BMD of 105.90HU (p<0.001). In patients with lumbar fractures, 27 patients were in the younger cohort, with mean BMD of 192.26HU and 23 patients in the older cohort with mean BMD of 114.31HU (p<0.001). At the threshold of 110 HU, set for specificity, the magnitude of difference between the age stratified cohorts was greater in the thoracic spine (p<0.001 vs. p=0.003). At the other thresholds: 135HU (balanced for sensitivity and specificity) and 160 HU (90% sensitivity), age of 65 years or older was significantly associated with reduction in CT derived measure of BMD (p<0.001 in all cases). Discussion. This study demonstrates the relative frequency of osteoporosis in acute fractures of the thoracic and lumbar spine, and how this changes with age; it is also the first study to do this using opportunistic CT scans. There seems to be a strong association between a reduction in bone mineral density and advanced age, in patients presenting with acute fractures of the spine. This approach may save on the extra cost and additional radiation exposure that may be associated with DXA scanning; in addition, it may help provide clinicians and patients with an approach to monitor developing problems with BMD before it becomes clinically apparent, especially in younger patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 50 - 50
1 May 2017
Roberton A Patel N Hockings M
Full Access

Background. Best practice tariff (BPT) for hip fracture was introduced in April 2010, offering financial incentive to encourage trusts to implement best practice and improve quality of care. This equates to £1335. An early indicator of a patient's outcome is the time to operation from admission, with best practice targets of <36hours as a key marker of quality. As well as being detrimental to patient experience, delays in the time to operation have clear links to increased mortality rates. Method. We performed a retrospective audit of neck of femur fracture patients from 01.01.14 for 12 months, investigating time to theatre, other BPT targets, and attainment of BPT. A cost analysis was also performed from financial data. Results. Of 471 patients, 461 operations were performed. Our median time to surgery was 24.9 hours. 140 (30%) of patients were not operated on within 36 hours. 134 of these (96%) would have met the BPT had they been operated on within the 36 hour target i.e. all other BPT targets were met. This equates to a loss of £178,890. Conclusions. We achieved time to theatre target for 70% of patients (compared to 71.7% reported nationally), which is suboptimal. A solution is to dedicate more theatre time to hip fractures on theatre lists or lengthened daily trauma lists. However, at £1200 per hour running theatre, this on its own would not be cost effective. Improved theatre utilisation by 10% can potentially save the trust £3,960,000 in a year. We have put forward plans to audit our current theatre usage, potentially improving utilisation and efficiency (e.g. planned hip fracture first on list from previous day to avoid start delay). Additionally we have introduced a “Time of breach” onto our trauma board to concentrate attention on this part of best practice. Level of Evidence. Level 3


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 42 - 42
1 Oct 2016
Pasko K Hall R Neville A Tipper J
Full Access

Surgical interventions for the treatment of chronic neck pain, which affects 330 million people globally [1], include fusion and cervical total disc replacement (CTDR). Most of the currently clinically available CTDRs designs include a metal-on-polymer (MoP) bearing. Numerous studies suggest that MoP CTDRs are associated with issues similar to those affecting other MoP joint replacement devices, including excessive wear and wear particle-related inflammation and osteolysis [2,3]. A device with a metal-on-metal (MoM) bearing has been investigated in the current study. Six MoM CTDRs made from high carbon cobalt-chromium (CoCr) were tested in a six-axis spine simulator, under standard ISO testing protocol (ISO-18192-1) for a duration of 4 million cycles (MC). Foetal bovine calf serum (25%v/v), used as a lubricant, was changed every 3.3×10. 5. cycles and saved for particle analysis. Components were taken down for measurements after each 10. 6. cycles; surface roughness, damage modes and gravimetric wear were assessed. The mean wear rate of the MoM CTDRs was 0.24mm. 3. /MC (SD=0.03), with the total volume of 0.98mm. 3. (SD=0.01) lost over the test duration. Throughout the test, the volumetric wear was linear; no significant bedding-in period was observed. The mean pre-test surface roughness decreased from 0.019μm (SD=0.005) to 0.012μm (SD=0.002) after 4MC of testing. Prior to testing, fine polishing marks on the bearing surfaces were observed using light microscopy. Following 4MC of testing, these polishing marks had been removed. Consistently across all components, surface discolouration and multidirectional, criss-crossing, circular wear tracks, caused by abrasive wear, were observed. The wear results showed low wear rates exhibited by MoM CTDRs (0.24mm. 3. /MC), when compared CTDR designs incorporating metal-on-polymer bearings (0.56mm. 3. /MC) [4] as well as MoM lumbar CTDRs [5,6] (0.76mm3/MC – 6.2mm. 3. /MC). These findings suggest that MoM CTDRs are more wear resistant than MoP CTDRs, however the particle characterisation and biological consequences of wear remain to be determined


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 46 - 46
1 Jan 2017
Errani C Leone G Cevolani L Spazzoli B Frisoni T Donati D
Full Access

The purpose of our study was to identify possible risk factors of patients with GCT of the long bones after curettage and packing the bone cavity with bone cement or bone allografts. We retrospectively reviewed the records of 249 patients with GCT of the limbs treated at Musculoskeletal Oncology Department of our institution between 1990 and 2013, confirmed histologically and recorded in the Bone Tumor Registry. We reviewed 219 cases located in the lower limb and 30 of the upper limb. This series includes 135 females and 114 males, with mean age 32 years (ranging 5 to 80 yrs). According to Campanacci's grading system, 190 cases were stage 2, 48 cases stage 3, and 11 cases stage 1. Treatment was curettage (intralesional surgery). Local adjuvants, such as phenol and cement, were used in 185 cases; whereas in the remaining 64 cases the residual cavity was filled with allografts or autografts only. Oncological outcome shows 203 patients alive and continuously disease-free (CDF), 41 patients NED1 after treatment of local recurrence (LR), 2 patients NED1 after treatment of lung metastases, 2 AWD with lung metastases. One patient died of unrelated causes (DOD). LR rate was 15.3% (38 pts). Lung metastases rate was 1.6% (4 pts). In patients treated by curettage and cement (185 cases) LR was 12% (22 pts). Conversely, in patients treated curettage and bone allografts it was higher (16/64 cases), with an incidence of 25% of cases (p=0.004). Oncological complications seemed to be related with site, more frequently occurring in the proximal femur (p=0.037). LR occurred only in stage 2 or 3 tumors without statistical significance (p>0.05). The mean interval between the first surgical treatment and LR was 22 months (range: 3–89 mos). However, in the multivariate analysis no significant statistical effect on local recurrence rate could be identified for gender, patient's age, Campanacci's grading, or cement vs allografts. The only independent risk factor related to the local recurrence was the site, with a statistical significance higher risk for patients with GCT of the proximal femur (p= 0.008). Our observation on the correlation of tumor location and risk of local recurrence is new. Therefore, special attention must be given to GCTs in the proximal femur. In fact, primary benign bone tumors in the proximal femur are difficult to treat due to the risk of secondary osteonecrosis of the femoral head or pathologic fracture. Numerous methods of reconstructions have been reported. Among these, total hip arthroplasty (THA) or bipolar hip arthroplasty (BHA) should be avoided when possible as more cases are observed in young patients. Therefore, we do not suggest different approach for the proximal femur. GCT in the proximal femur is much more difficult to treat than in other sites, but if curettage is feasible, the best way is to save the joint with a higher risk of local recurrence, knowing that the sacrifice of the hip articulation in case of recurrence is always possible with THA or BHA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 23 - 23
1 Aug 2013
Ellapparadja P
Full Access

Torus (Buckle) fractures of distal radius are common in children and form a major workload of any fracture clinic. They are usually stable and do not displace. Recent evidence has shown that these fractures can be safely treated in a futura splint. In UK, many of the hospitals are still treating these patients with full plaster. Bringing back these patients to fracture clinic for plaster removal means more workload and places more financial burden in the NHS. Our study is a completed audit cycle where we successfully implemented treatment with futura splint. Over a period of 6 months, 25 torus fractures were diagnosed & treated in A/E back slab. Mean age was 8.24 (Range: 3–12 yrs). Most common MOI was fall on outstretched hand. All cases had presented to A/E within 24 hours. 5 were given futura splint at the fracture clinic. 21 cases received full plaster. They were seen back in clinic in 3–4 weeks for plaster removal. After this audit was presented, we started treating these fractures with futura splint. Reauditing 6 months later revealed that of 31 cases, we had successfully treated 28 with Futura splint. 2 were treated with plaster on parent's insistence. The remaining one was treated in plaster as we could not fit a futura splint. There were no problems reported with futura splint. By definition, torus fractures are stable. The major problem with these fractures lies in the correct diagnosis. We have treated this fracture successfully with futura splint. Recent papers have shown that every patient treated with futura splint saves nearly £53 when compared to plaster treatment. Implementing this treatment has reduced plaster related problems. We hope this audit will help in changing practice in other hospitals in NHS


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 52 - 52
1 Aug 2013
Howie D Kinninmonth A
Full Access

There has not been any published work quantifying the volume cement used/needed for knee arthroplasty. The number of mixes of cement used is at the discretion of the surgeon, based on their own experience/training. The objective of this study was to quantify the volume of cement used for knee arthroplasty in our institution, and to observe variations between surgeons and implant size. The study then aimed to calculate the theoretical volumes required and observe the volume of cement actually implanted before commenting on cost implications of cement usage. Prospective data for 85 consecutive knee arthroplasties performed by 9 consultants was examined. A single mix in this institution refers to 40g of Palacos R+G. Significant variation between surgeons was seen, with a range of one to three mixes being used. Several surgeons used one mix exclusively, independent of implant size, whilst others exclusively used two mixes. The departmental average was 1.4 mixes per knee. The total surface area of our largest implants (Size 8 Triathlon Femoral and Tibial components) was measured-108cm. 2. and compared to the volume of a single mix of cement −49 cm. 3. Even using the largest component size, a single mix will provide 4.5mm of uniform cement coverage. The volume of cement actually implanted during 10 knee arthroplasties was examined by weighing the residual cement. The average volume of cement implanted was 18cm. 3. per knee. In 2009 1085 knee replacements were performed in this institution. If all surgeons in the department used a single mix of cement this could potentially save £16,357.46 per year. (Presuming average usage was 1.4 mixes per knee, 434 ‘extra’ mixes were used, costing £37.69 each) We conclude that a single mix of cement will cover the area required for all Triathlon implants and that less than half a mix (on average) is actually implanted


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 14 - 14
1 Jul 2014
Emohare O Dittmer A Cagan A Polly D Gertner E
Full Access

Summary Statement. It is now possible to diagnose osteoporosis using incidental CT scans; this approach has been used to objectively demonstrate the role of osteoporosis in fracture in ankylosing spondylitis patients. Background. In advanced disease, Ankylosing Spondylitis (AS) is frequently associated with a reduction in bone mineral density (BMD), this contributes to pain and predisposes to fractures. Quantifying this reduction in BMD is complicated by the simultaneous processes occurring, in which there is both an overgrowth of bone (syndesmophytes) and a concurrent loss of trabecular bone. Traditional methods such as dual-energy X-ray absorptiometry (DXA) struggle to generate accurate estimates for BMD in these patients. It has recently become possible to diagnose osteoporosis, with a high sensitivity and specificity, using incidental CT scans of the L1 vertebra. The purpose of this study was to evaluate the use of opportunistic CT screening in the diagnosis of osteoporosis in patients with AS who had sustained vertebral fractures. Patients & Methods. Following Institutional review board approval, patients with AS who presented, with acute fractures of the spine, to our facility between 2004 and 2013 were reviewed to assess whether or not they had a Computed Tomography (CT) scan of the abdomen on admission or in the 6 months before or after injury. In addition, patients were also required to have signs of advanced AS such as the presence of syndesmophytes and syndesmophyte bridging; patients with fractures through L1 were excluded. Of those fitting the criteria, a region of Interest (ROI) was generated over the body of L1, Hounsfield unit (HU) were then measured. Results. Of the 42 patients reviewed, a total of 17 AS patients fit the above criteria. 15 were male and 2 were female, mean age of the whole cohort was 69.9years (range 22–85; SD 15.9). Using a threshold balanced for sensitivity and specificity (<135 HU) which differentiates between osteopenia and osteporosis, 14 (82%) patients were found to have a BMD less than 135HU; a higher threshold (<160 HU) with 90 % sensitivity for differentiating osteoporosis from osteopenia was applied to the group, and 15 patients (88%) were found to be osteoporotic. Of note all the females in the study were osteoporotic. Discussion and Conclusion. This study demonstrates, for the first time, using opportunistic CT screening, that a high proportion of AS patients who sustain fractures have osteoporosis; this overcomes the difficulties that have been encountered with the use of DXA in this unique group of patients. This simple and accessible method saves on excess cost and exposure to radiation. With a high sensitivity, patients identified using this method can then be managed more proactively. We believe these data have the potential to significantly impact the day to day management of patients with spondyloarthropathies


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 36 - 36
1 Aug 2012
Grange S Wills G Gilbert L Santer M Recio A Kanani M Zhang P Smitham P
Full Access

Background and objectives. The prevention of osteoporotic fractures is a global problem. Key to this strategy is efficient identification of ‘at risk’ patients in order to address the osteoporosis pandemic, including the identification of previously sustained fractures. GP practices are now integrating touch screens as a method of registering patients' attendance for an appointment, so all ages of patients are becoming familiar with this channel of communication. Our touch screen patient administered questionnaire system intends to provide an effective solution. Methods. The Virtual Research Integration Collaboration (VRIC) framework supports the integration of basic science and clinical research. It enables the management of research lifecycles by integrating scientific approaches with everyday work practice in a virtual research environment (VRE). ‘Catch Before a Fall’ (CBaF) is a clinical research project using VRIC, using a dedicated interface, co-designed by orthopaedic surgeons and basic scientists, adapted for sensory and IT impaired subjects to capture such information, since approximately 75% of registered over 65 year olds visit their GP each year. Results. Established in test sites across the UK, Data analysis is conducted via the VRIC ‘on-line’ portal. The conclusion of the research process is followed up within that tool. Using the validated osteoporosis risk questionnaire augmented by self reporting of height loss to identify missed vertebral fractures, we calculate the patients' risk factor of developing osteoporosis and of having an osteoporosis related fracture within the next 10 years. Patients' data are collected through CBaF (figure 1) and stored in data structures matching the VRIC architecture for automatic importing via a dedicated script and offering direct clinical service provider feedback. Conclusion. Patients recollect a previous fracture including other risk factors, so we are automating the secure data collection process to improve efficiency and save resources. We should see a ‘win’ for the patient who will receive better informed care. CBaF supports the practice who will streamline their pathway for effective osteoporosis management. The insight into personalised care management is a pathfinder, demonstrating improvement of services for our community, should reduce the greater silent population of osteoporosis sufferers worldwide, addressing the acute service burden ‘at source’


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 12 - 12
1 Jul 2014
Emohare O Cagan A Dittmer A Switzer J Polly D
Full Access

Summary Statement. It is now possible to diagnose osteoporosis using incidental abdominal CT scans; applying this approach to fractures of the cervical spine demonstrates levels of osteoporosis in patients over 65. Introduction. Recently published data now makes it possible to screen for osteoporosis in patients who, in the course of their hospital stay, have had Computed Tomography (CT) scans of their abdomen for reasons other than direct imaging. This is as a result of CT derived bone mineral density (BMD) in the first lumbar vertebra (L1) being correlated BMD derived from Dual-energy X-ray absorptiometry (DEXA) scans. The advantage of this is the reduction in both cost and radiation exposure. Although age has a detrimental effect on BMD, relatively few patients have formal DEXA studies. The aims of this study were to evaluate the utility of this new technique in a cohort of patients with acute fractures of the cervical spine and to compare relative values for BMD in patients aged over 65 with those aged under 65, and thus define the role of osteoporosis in these injuries. Methods & Patients. Following Institutional review board approval, we performed a retrospective study of patients who presented to a level I trauma center with acute fractures of the cervical spine between 2010 and 2013; patients also had to have had a CT scan of their L1 vertebra either during the admission or within 6 months of their admission (for any other clinical reason). Using a picture archiving and communication (PACS) system, we generated regions of interest (ROI) of similar size in the body of L1 (excluding the cortex), in line with the publication by Pickhardt et al., and computed the mean values for Hounsfield units (HU). These values were compared against established threshold values which differentiate between osteoporosis and osteopenia; for a balanced sensitivity and specificity, <135 HU is the threshold and for 90% sensitivity a HU threshold of <160 HU is set. Comparisons were also performed between age stratified groups. Results. A total of 187 patients were reviewed for eligibility, 91 patients met the criteria with 53 patients aged 64 years or younger (range 23–64) and 38 patients aged above 65 years (range 65–98). In the younger cohort, 6/53 (11% were osteoporotic, using the lower threshold, while the higher threshold indicated 5/53 (17%) of patients under 65 years were osteoporotic; mean HU for the group was 195.8 (SD 43.3). In the older cohort, 24/38 (63%) were osteoporotic using the lower threshold, whereas 34/38 (89%) were osteoporotic using the higher threshold. Mean HU for the cohort aged over 65 years was 118.7 (SD 38.4). Age based comparison of the mean values, regardless of threshold, was statistically significant (p<0.001) in both cases. Discussion and Conclusions. This study demonstrates, for the first time in the cervical spine (including C2), the role of age related osteoporosis in acute fractures of the cervical spine. This new technique harnessing the presence of opportunistic CT scans of the abdomen saves on the extra cost and radiation exposure that may be associated with DEXA scanning. In younger patients, the higher threshold indicated 17% were osteoporotic – in the setting of an opportunistic scan, this may afford them the opportunity to commence prophylactic treatment to prevent future fractures. We believe these result have the potential to significantly impact future clinical practice