Rotator cuff tears are common in middle-aged and elderly patients. Despite advances in the surgical repair of rotator cuff tears, the rates of recurrent tear remain high. This may be due to the complexity of the tendons of the rotator cuff, which contributes to an inherently hostile healing environment. During the past 20 years, there has been an increased interest in the use of biologics to complement the healing environment in the shoulder, in order to improve rotator cuff healing and reduce the rate of recurrent tears. The aim of this review is to provide a summary of the current evidence for the use of forms of biological augmentation when repairing rotator cuff tears. Cite this article:
Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation.Aims
Methods
Background: Recent studies of arthroscopic rotator cuff repairs have shown high failure. The different suture configurations were mostly tested in non degenerative animal tendon specimen. We used instead fresh-frozen degenerative human cadaver
Aims. Failure of healing is a well-known problem after repair of the rotator cuff. This study aimed to investigate if early repair of trauma-related full-thickness rotator cuff tears (FTRCTs) could prevent this failure. Patients and Methods. In this prospective trial, 62 consecutive patients (14 women (23%), 48 men (77%); median age 61 years (interquartile range (IQR) 54 to 65)) with trauma-related FTRCT underwent arthroscopic single-row repair within six weeks of trauma. Tendon integrity was assessed one year after surgery using the Sugaya score on MR images. Patients were followed up with Western Ontario Rotator Cuff (WORC) index, EuroQol visual analogue scale (EQ VAS), and the Constant–Murley score (CS) two years after repair. Results. A total of 57 patients (92%) had MR images available at one year; 59 patients (95%) had CS (one year), WORC (two years), and EQ VAS scores (two years). Intact repair was found on MRI in 36 patients (63%); 13 patients (23%) displayed healing failure of at least one repaired tendon and eight patients (14%) displayed total healing failure. Median WORC index and relative CS improved from 30.8 points (IQR 20.1 to 38.6) at baseline to 85.0 points (IQR 60.6 to 95.7) at two years and 26.5 points (IQR 21.2 to 37.4) to 83.2 points (IQR 71.9 to 97.5) at one year, respectively. The relative CS at one year was significantly better among those with intact repairs compared with those with healing failure (91.6 vs 78.1 points; p = 0.031). Conclusion. Although early repair of trauma-related FTRCT improved patient relevant outcomes over two years for the entire cohort, only two out of three repaired
Rotator cuff tears are the most common cause of shoulder disability, affecting 10% of the population under 60 and 40% of those aged 70 and above. Massive irreparable rotator cuff tears account for 30% of all tears and their management continues to be an orthopaedic challenge. Traditional surgical techniques, that is, tendon transfers are performed to restore shoulder motion, however, they result in varying outcomes of stability and complications. Superior capsular reconstruction (SCR) is a novel technique that has shown promise in restoring shoulder function, albeit in limited studies. To date, there has been no biomechanical comparison between these techniques. This study aims to compare three surgical techniques (SCR, latissimus dorsi tendon transfer and lower trapezius tendon transfer) for irreparable rotator cuff tears with respect to intact cuff control using a clinically relevant biomechanical outcome of rotational motion. Eight fresh-frozen shoulder specimens with intact
We investigated the function of biceps in 18 patients (19 shoulders) with lesions of the rotator cuff. Their mean age was 59 years. Another series of 18 patients (19 shoulders) with normal
The role of inflammatory cells and their products in tendinopathy is not completely understood. Pro-inflammatory cytokines are upregulated after oxidative and other forms of stress. Based on observations that increased cytokine expression has been demonstrated in cyclically-loaded tendon cells we hypothesised that because of their role in oxidative stress and apoptosis, pro-inflammatory cytokines may be present in rodent and human models of tendinopathy. A rat supraspinatus tendinopathy model produced by running overuse was investigated at the genetic level by custom micro-arrays. Additionally, samples of torn supraspinatus tendon and matched intact subscapularis tendon were collected from patients undergoing arthroscopic shoulder surgery for rotator-cuff tears and control samples of subscapularis tendon from ten patients with normal
The purpose of this diagnostic, cross-sectional study, was to determine the predictive value of clinical examination versus ultrasonographic evaluation in rheumatoid arthritis patients, suspected of having rotator cuff disease. The left and right shoulders of fifty consecutive patients from the rheumatoid clinic were subjected to clinical examination by a senior registrar in the department. Impingement was evaluated using the Neer, Hawkins and posterior impingement tests. The supra-spinatus tendon insertion (Jobe test), infraspinatusteres minor tendon insertions (resisted external rotation) and subscapularis tendon insertion (Gerber lift-off and push-off tests) into the rotator cuff were evaluated for a possible tear. A Professional Sport Sonographer, located in a separate examination room then performed an ultrasonographic evaluation on all of the patients. The clinical results were compared to the ultrasound results, hoping to find a method that will improve our current screening of rheumatoid patients for rotator cuff disease and planning of possible surgical treatment. A significant difference was found between the clinical and sonographic evaluation of the
Two dimensional ultrasound of the shoulder joint has become a well established diagnostic tool. Difficult interpretation of ultrasonographic findings, however, suggests that ultrasound appears not to be an always reliable method, especially in partial thickness tears. The present study was performed to determine whether the use of three dimensional (3D) sonography further increases the diagnostic yield of ultrasound. On a total of 22 externally intact appearing
Aim: Revision of shoulder replacements in patients with irreparably damaged
Purpose of the study: The aim of this biomechanical study was to assess the performance of the deltoid muscle in the absence of a rotator cuff using different models for shoulder prosthesis. Material and methods: A computer model reproducing the three dimensions of the glenohumeral joint was use to analyze the force of the deltoid muscle during abduction movements in shoulders devoid of a rotator cuff. The three heads of the deltoid were analyzed in order to determine the most effective level of muscle tension. The lever arm of the deltoid was measured from 0–90° abduction. Using this 3D model, we simulated implantation of six different models of reversed prostheses in order to assess the biomechanical situation which would be the most favorable for the deltoid. Performance of the normal deltoid was compared with the performance of the deltoid after implantation of an anatomic prosthesis and after implantation of an reversed prosthesis. Several variables were studied: medial offset of the center of rotation, lateral offset of the humerus, lengthening of the deltoid muscle. Results: Optimal deltoid performance (especially from 60–90° abduction) was observed if the center of rotation was offset medially and the humerus was offset laterally and lowered. A 10% increase in the length of the muscle fibres increased muscle performance 18%. Exaggerated lateral offest of the humerus increased deltoid performance between 30 and 60° abduction but lost its beneficial effect at 90° abduction. From 15° abduction, a scapular notch appeared when the humerus was off set medially. This could be avoided if the humerus was offset laterally with a less medial center of rotation. Beyond 150° abduction, superior impingement appeared irrespective of the type of prosthesis. Discussion and conclusion: This biomechanical study proved the superiority of reversed prostheses compared with anatomic prostheses for massive rotator cuff tears. Medial offset of the center of rotation reduced shear forces on the glenoid. Lateral offset of the humerus increase via a pulley effect the lowering force of the deltoid. Lowering the humerus pulled on the muscle fibers of the deltoid and increased their performance. Dosing these three variables with an appropriate («ideal») design for the reversed prosthesis would optimize deltoid performance in patients with deficient
Purpose: Determine the ideal form of subacromial decompression. Method: Six cadaveric shoulders with intact
Purpose of the study: The aim of this study was to evaluate the anatomical and technical limits of endoscopic rotator cuff repair. Anatomical results were also compared with functional assessment of the shoulder. Material and methods: A multicentric serie of 87 patients presenting a full thickness rotator cuff tear repaired endoscopically was retrospectively reviewed at 25.4 months (mean) post surgery. Limits of the surgical technique were studied in correlation with functional results and anatomic radiographic evaluation (arthroscans in 93 p. 100). Results: Anatomical repair (normal thickness and no contrast in the subacromial space on arthroscan) was achieved in 83 p. 100 of the
Aim: To assess the outcome of arthroscopic subacromial decompression on rotator cuff muscles. Material: 44 patients with impingement syndrome and intact
Purpose: There is still debate on classification, pathogenesis, and treatment of partial non-full thickness tears of the rotator cuff. We assessed mid-term outcome after arthroscopic repair. Material and methods: Between 1990 and 1998, 208 partial tears of the
Aim: To investigate the effect of Arthroscopic Subacromial Decompression and rehabilitation on rotator cuff muscle strength and function. Material: 24 patients with primary impingement syndrome and intact
The June 2024 Shoulder & Elbow Roundup360 looks at: Reverse versus anatomical total shoulder replacement for osteoarthritis? A UK national picture; Acute rehabilitation following traumatic anterior shoulder dislocation (ARTISAN): pragmatic, multicentre, randomized controlled trial; acid for rotator cuff repair: a systematic review and meta-analysis of randomized controlled trials; Metal or ceramic humeral head total shoulder arthroplasty: an analysis of data from the National Joint Registry; Platelet-rich plasma has better results for long-term functional improvement and pain relief for lateral epicondylitis: a systematic review and meta-analysis of randomized controlled trials; Quantitative fatty infiltration and 3D muscle volume after nonoperative treatment of symptomatic rotator cuff tears: a prospective MRI study of 79 patients; Locking plates for non-osteoporotic proximal humeral fractures in the long term; A systematic review of the treatment of primary acromioclavicular joint osteoarthritis.
Orthopaedic surgery requires grafts with sufficient mechanical strength. For this purpose, decellularized tissue is an available option that lacks the complications of autologous tissue. However, it is not widely used in orthopaedic surgeries. This study investigated clinical trials of the use of decellularized tissue grafts in orthopaedic surgery. Using the ClinicalTrials.gov (CTG) and the International Clinical Trials Registry Platform (ICTRP) databases, we comprehensively surveyed clinical trials of decellularized tissue use in orthopaedic surgeries registered before 1 September 2022. We evaluated the clinical results, tissue processing methods, and commercial availability of the identified products using academic literature databases and manufacturers’ websites.Aims
Methods
Rotator cuff disease (RCD) can considerably decrease quality of life. Here, we investigated whether health-related quality of life (HRQoL) influences the need for surgery in patients with RCD. We performed an analysis of 417 patients with symptomatic RCD who were recruited from two hospitals between June 2008 and December 2014 to be randomized to receive non-surgical or surgical treatment. After a three-month rehabilitation period, 36-Item Short-Form Health Survey questionnaire (SF-36), shoulder pain (visual analogue scale (VAS)), and shoulder function (Constant-Murley score) data were available from 191 still-symptomatic patients who were eligible for surgery. A control group was formed from 87 excluded patients who were no longer eligible for surgery due to relief of symptoms.Aims
Methods
Rotator cuff muscle atrophy and fatty infiltration affect the clinical outcomes of rotator cuff tear patients. However, there is no effective treatment for fatty infiltration at this time. High-intensity interval training (HIIT) helps to activate beige adipose tissue. The goal of this study was to test the role of HIIT in improving muscle quality in a rotator cuff tear model via the β3 adrenergic receptor (β3AR). Three-month-old C57BL/6 J mice underwent a unilateral rotator cuff injury procedure. Mice were forced to run on a treadmill with the HIIT programme during the first to sixth weeks or seventh to 12th weeks after tendon tear surgery. To study the role of β3AR, SR59230A, a selective β3AR antagonist, was administered to mice ten minutes before each exercise through intraperitoneal injection. Supraspinatus muscle, interscapular brown fat, and inguinal subcutaneous white fat were harvested at the end of the 12th week after tendon tear and analyzed biomechanically, histologically, and biochemically.Aims
Methods