Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 52 - 52
1 May 2012
S. C C. D F. V A. C
Full Access

Background. Rotator cuff tears pose a huge socioeconomic burden. Our study uses Fourier transform infrared spectroscopy (FTIR) as it is a quick, non-manipulative and non-destructive test, which can identify a wide range of chemical targets from small intraoperatively obtained specimens. The aim of this study was (i) to characterise the chemical and structural composition of rotator cuff tendons and (ii) to identify structural differences between anatomically distinct tear sizes. Such information may help to identify specific biomarkers of rotator cuff tear pathologies, which in turn could allow early identification and monitoring of disease progression. FTIR may provide insight into the different healing rates of different tear sizes. Methods. The infrared spectra of 81 torn rotator cuff tendons were measured using a FTIR spectrometer. The rotator cuff tear sizes were classified as partial, small, medium, large and massive, and compared to 14 normal controls. All spectra were classified using standard multivariate analysis; principal component analysis, partial least square and discriminant function analysis. Results. FTIR readily differentiated between normal and torn tendons, and different tear sizes. We identified the key discriminating molecules and spectra altered in torn tendons as: (i) carbohydrates/phospholipids (1030-1200 cm. -1. ), (ii) collagen (1300-1700, 3000-3350 cm. -1. ) and (iii) lipids (2800-3000 cm. -1. ). Partial tears were chemically distinct from normal and small tears, and primarily involved a reduction in collagen type II. Conclusion. This study has demonstrated that FTIR can identify different sizes of rotator cuff tear based upon distinguishable chemical and structural features. The onset of rotator cuff tear pathology is mainly due to alterations of the collagen structural arrangements, with associated changes in lipids and carbohydrates. The approach described is rapid and has the potential to be used intraoperatively to determine the quality of the tendon and extent of disease, thus guiding surgical repairs or for monitoring of treatments


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 49 - 49
1 Jul 2020
Lapner P Laneuville O Uhthoff HK Zhang T Howard L Pollock J Ruggiero S Trudel G
Full Access

Tears of the rotator cuff tendons are a very common entity. Despite recent advances in arthroscopic rotator cuff repair, the re-tear rate remains high. Thus, new methods to improve healing rates following rotator cuff repair must be sought. The purpose of this prospective randomized double-blind controlled study is to compare the functional outcomes and healing rates of an adjuvant pre-operative bone microfracture technique prior to arthroscopic cuff repair. Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a percutaneous bone microfracture of the supraspinatus footprint or a “soft tissue needling” technique, in which the pin was passed through the peripheral edges of the rotator cuff, five-seven days prior to index surgery, under ultrasound guidance. Follow-ups were completed at 3, 6, 12 and 24 months post-operatively. Healing status was determined by ultrasound at 6 and 24 months. The primary objective was to compare the WORC score at 24 months. Secondary objectives included the healing status via ultrasound, the Constant, and the ASES scores. A sample size calculation determined that 90 patients provided 80% power to detect a statistical difference between groups. Baseline demographic data did not differ between groups. No statistical differences were detected in the WORC outcome at any time points (p=0.47, baseline, p=0.60, 3 months, p=0.79, 6 months, p=0.50, 12 months, p=0.54, 24 months). Healing rates did not differ between groups (P=0.34) and no differences were observed in the ASES or Constant Scores at all time-points. Statistically significant improvements occurred in both groups from baseline to all time points in all clinical outcome scores (p < 0 .0001). No statistically significant differences in primary or secondary outcomes were identified between pre-operative bone microfracture and soft tissue needling techniques prior to arthroscopic rotator cuff repair. This study does not support pre-operative microfracture as a adjuvant technique prior to arthroscopic cuff repair


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 3 - 3
1 Feb 2020
Hartwell M Sweeney RHP Marra G Saltzman M
Full Access

Background. Rotator cuff atrophy evaluated with computed tomography scans has been associated with asymmetric glenoid wear and humeral head subluxation in glenohumeral arthritis. Magnetic resonance imaging has increased sensitivity for identifying rotator cuff pathology and has not been used to investigate this relationship. The purpose of this study was to use MRI to assess the association of rotator cuff muscle atrophy and glenoid morphology in primary glenohumeral arthritis. Methods. 132 shoulders from 129 patients with primary GHOA were retrospectively reviewed and basic demographic information was collected. All patients had MRIs that included appropriate orthogonal imaging to assess glenoid morphology and rotator cuff pathology and were reviewed by two senior surgeons. All patients had intact rotator cuff tendons. Glenoid morphology was assigned using the modified-Walch classification system (types A1, A2, B1, B2, B3, C, and D) and rotator cuff fatty infiltration was assigned using Goutallier scores. Results. 46 (35%) of the shoulders had posterior wear patterns (23 type B2s, 23 type B3s). Both the infraspinatus and teres minor independently had significantly more fatty infiltration in B2 and B3 type glenoids compared to type A glenoids (p<0.001). There was a greater imbalance in posterior rotator cuff muscle fatty atrophy in B2 and B3 type glenoids compared to type A glenoids (p<0.001). However, there was no difference in axial plane imbalance between B2 and B3 glenoids (p=1.00). There was increased amount fatty infiltration of the infraspinatus among B2 and B3-type glenoids compared to type A glenoids on multivariate analysis controlling for age and gender (p<0.001). Conclusions. These results identify significant axial plane rotator cuff muscle imbalances in B2 and B3-type glenoids compared to concentrically worn glenoids, favoring a relative increase in fatty infiltration of the infraspinatus and teres minor compared to the subscapularis in glenoids with patterns of posterior wear. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 57 - 57
1 Jul 2020
Chevrier A Hurtig M Lacasse F Lavertu M Potter H Pownder S Rodeo S Buschmann M
Full Access

Surgical reattachment of torn rotator cuff tendons can lead to satisfactory clinical outcome but failures remain common. Ortho-R product is a freeze-dried formulation of chitosan (CS) that is solubilized in platelet-rich plasma (PRP) to form injectable implants. The purpose of the current pilot study was to determine Ortho-R implant acute residency, test safety of different implant doses, and assess efficacy over standard of care in a sheep model. The infraspinatus tendon (ISP) was detached and immediately repaired in 22 skeletally mature ewes. Repair was done with four suture anchors in a suture bridge configuration (n = 6 controls). Freeze-dried formulations containing 1% w/v chitosan (number average molar mass 35 kDa and degree of deacetylation 83%) with 1% w/v trehalose (as lyoprotectant) and 42.2 mM calcium chloride (as clot activator) were solubilized with autologous leukocyte-rich PRP and injected at the tendon-bone interface and on top of the repaired site (n = 6 with a 1 mL dose and n = 6 with a 2 mL dose). Acute implant residency was assessed histologically at 1 day (n = 2 with a 1 mL dose and n = 2 with a 2 mL dose). Outcome measures included MRI assessment at baseline, 6 weeks and 12 weeks, histopathology at 12 weeks and clinical pathology. MRI images and histological slides were scored by 2 blinded readers (veterinarian and human radiologist, and veterinarian pathologist) and averaged. The Generalized Linear Model task (SAS Enterprise Guide 7.1 and SAS 9.4) was used to compare the different groups with post-hoc analysis to test for pairwise differences. Ortho-R implants were detected near the enthesis, near the top of the anchors holes and at the surface of ISP tendon and muscle at 1 day. Numerous polymorphonuclear cells were recruited to the implant in the case of ISP tendon and muscle. On MRI, all repair sites were hyperintense compared to normal tendon at 6 weeks and only 1 out 18 repair sites was isointense at 12 weeks. The tendon repair site gap seen on MRI, which is the length of the hyperintense region between the greater tuberosity and tendon with normal signal intensity, was decreased by treatment with the 2 mL dose when compared to control at 12 weeks (p = 0.01). Histologically, none of the repair sites were structurally normal. A trend of improved structural organization of the tendon (p = 0.06) and improved structural appearance of the enthesis (p = 0.1) with 2 mL dose treatment compared to control was seen at 12 weeks. There was no treatment-specific effect on all standard safety outcome measures, which suggests high safety. Ortho-R implants (2 mL dose) modulated the rotator cuff healing processes in this large animal model. The promising MRI and histological findings may translate into improved mechanical performance, which will be assessed in a future study with a larger number of animals. This study provides preliminary evidence on the safety and efficacy of Ortho-R implants in a large animal model that could potentially be translated to a clinical setting


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 30 - 30
1 Aug 2013
de Beer M
Full Access

Purpose:. The objective of this study was to determine the tensile strength of the different components of the rotator cuff tendons and their relationship to rotator cuff tears. Method:. The tests were done on a newly designed and built test-bench that performed the tests at a consistent rupture speed. The tests were done on four fresh frozen cadaver shoulders. The capsular and tendinous layers of the rotator cuff were divided leaving them only attached on the humeral side. Separate tensile tests were done on these tendons, after they were divided into 10 mm wide strips before testing. The tendon thickness was also measured. Results:. The maximum force tolerated by these tendons is comparable. The elongation however is not the same; the tendinous part of the tendon elongated more. The strength of the “rotatorhood” was then determined. This is a thin layer of tendon extending beyond the greater tuberosity, connecting the supra-spinatus to the sub-scapularis via the bicipital groove. The 10 mm of the “rotator hood” ruptured at an average force of 70 Newtons. Conclusion:. 1. The two layers of the rotator cuff contribute equally to the cuff's strength. 2. The difference in elongation of the tendinous and capsular layers makes the capsular layer more vulnerable to elongation stress. 3. The “rotatorhood” is a strong important structure with a mechanically advantageous insertion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 34 - 34
1 Feb 2012
White C Bunker T Hooper R
Full Access

Given that there is limited time available to the surgeon in arthroscopic rotator cuff repair, how is the time best spent? Should they place one Modified Mason-Allen, two mattress or four simple sutures? This study reverses current thought. In an in-vitro biomechanical single pull to failure study we compared the ultimate tensile strength of simple, mattress and grasping sutures passed with an arthroscopic suture passer (Surgical Solutions Express-Sew). The aim was to determine which suture configurations would most simply, repeatably and reliably repair the rotator cuff. The ultimate tensile strength and mode of failure of six different suture configurations was repeatedly tested on a validated porcine rotator cuff tendon model, using a standard suture material (Number 2 Fiberwire) passed with the Surgical Solutions Express-sew, in a Hounsfield type H20K-W digital tensometer. Standardising the number of suture passes to four, the strongest construct was two mattress sutures (Mean 169N), followed by single Modified Kessler (Mean 161N), four simple sutures (Mean 155N) and finally a single Mason Allen suture (Mean 140N). Suture configurations involving two passes were all weaker than those with four (one way analysis of variance p=0.026), even when Number 2 Fibertape was used to augment strength. These results show little difference in strength for varying complexity of four pass suture passage (one way analysis of variance p=0.61). In simple terms there is no demonstrable difference in the strength of construct whether the surgeon uses four simple, two mattress or one grasping suture. This study allows the surgeon to justify using the simplest configuration of suture passage that works in his hands in order to obtain a reliable and repeatable repair of the rotator cuff arthroscopically


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 84 - 84
1 Nov 2016
Hawkins R Thigpen C Kissenberth M Hunt¸ S.J. Tolan Q Swinehart S Gutta C Tokish J
Full Access

Studies have shown that the trees minor plays an important role after total (TSA) and reverse (RSA) shoulder arthroplasty, as well as in maintenance of function in the setting of infraspinatus wasting. In this regard, teres minor hypertrophy has been described as a compensatory change in response to this infraspinatus wasting, and has been suggested that this compensatory hypertrophy may mitigate the loss of infraspinatus function in the patient with a large rotator cuff tear. The purpose of this study was to determine the prevalence of teres minor hypertrophy in a cohort of patients undergoing rotator cuff repair, and to determine its prognostic effect, if any, on outcomes after surgical repair. Over a 3 year period, all rotator cuff repairs performed in a single practice by 3 ASES member surgeons were collected. Inclusion criteria included both preoperative and postoperative validated outcomes measures (minimum 2 year), and preoperative Magnetic Resonance Imaging (MRI) scanning. 144 patients met all criteria. MRIs were evaluated for rotator cuff tear tendon involvement, tear size, and Goutallier changes of each muscle. In addition, occupational ratios were determined for the supraspinatus, infraspinatus, and teres minor muscles. Patients were divided into 2 groups, based upon whether they had teres minor hypertrophy or not, based on a previously established definition. A 2 way ANOVA was used to determine the effect of teres minor hypertrophy(tear size by hypertrophy) and Goutallier. Teres minor hypertrophy was a relatively common finding in this cohort of rotator cuff patients, with 51% of all shoulders demonstrating hypertrophy. Interestingly, in patients without an infraspinatus tear, teres minor hypertrophy was still present in 19/40 (48%) of patients. Teres minor hypertrophy had a significant, negative effect ASES scores after rotator cuff repair in patients with and without infraspinatus tearing, infraspinatus atrophy, and fatty infiltrative changes (P<0.05). In general, the presence of teres minor hypertrophy showed 10–15% less improvement (Figure 1) than when no hypertrophy was present, and this was consistent across all tear sizes, independent of Goutallier changes. Teres minor hypertrophy is a common finding in the setting of rotator cuff tearing, including in the absence of infraspinatus tearing. Contrary to previous publications, the presence of teres minor hypertrophy in patients with rotator cuff repair does not appear to be protective as a compensatory mechanism. While further study is necessary to determine the mechanism or implication of teres minor hypertrophy in setting of rotator cuff repair, our results show it is not a positive of outcomes following rotator cuff repair


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 576 - 576
1 Dec 2013
Wang C Wong T
Full Access

Background:. Massive rotator cuff tear can cause functional disability due to instability and degenerative changes of the shoulder joint. In patients with massive irreparable rotator cuff tear, tendon transfer is often used as the salvage procedure. Latissimus dorsi and pectoris major transfer are technically demanding procedures and may incur complications. The biceps tendon transfer may provide a biologically superior tissue patch that improves the biomechanics of the shoulder joint in patients with irreparable rotator cuff tear. This study evaluated the functional outcomes of biceps tendon transfer for irreparable rotator cuff tear in 6 patients with two years and longer follow-up. Methods:. Between September 2006 and October 2011, 50 patients with 50 shoulders underwent surgical repair for MRI confirmed rotator cuff tear. Among them, six patients with massive irreparable rotator cuff tear were identified intraoperatively, and underwent proximal biceps tendon transfer to reconstruct the rotator cuff tear. The biceps tendon was tenodesed at the bicipital groove, and the proximal intra-articular portion of the biceps tendon was transected. The biceps graft was fanned out and the distal end fixed to the cancellous trough around the greater tuberosity with suture anchor. The anterior edge was sutured to the subscapularis and the posterior edge to the infraspinatus tendon or supraspinatus if present. Postoperative managements included sling protection and avoidance of strenuous exercises for 6 weeks, and then progressive rehabilitation until recovery. Results:. The evaluation parameters included VAS pain score, UCLA score, Constant score and AHES score, and X-rays of the shoulder. At follow-up of 25.3 ± 25.0 (range 22 to 63) months, the mean VAS pain score decreased from 9.3 ± 0.8 preoperatively to 1.7 ± 1.4 postoperatively (p < 0.001). All patients presented with significant improvements in pain and function of the shoulder for daily activities after surgery, however, only one patient achieved excellent results. There is no correlation of functional outcome with age, gender and body mass index. There was no infection or neurovascular complication. Discussion:. The biceps transfer provides soft tissue coverage of the humeral head, and restores the superior stability of the shoulder joint. The transferred biceps tendon also improves the mechanics and increases the compression force of the humeral head to the glenoid fossa. The results of the current study showed significant pain relief and improvement of shoulder function after biceps tendon transfer for irreparable rotator cuff tear. Conclusion:. Biceps tendon transfer is effective in the management of massive irreparable rotator cuff tear. The procedure is technically accessible with minimal surgical risks


Bone & Joint Research
Vol. 3, Issue 6 | Pages 193 - 202
1 Jun 2014
Hast MW Zuskov A Soslowsky LJ

Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing.

Cite this article: Bone Joint Res 2014;3:193–202.