A 66-year-old man presented with an infected
Introduction: Peri-prosthetic fractures following hip resurfacing arthroplasty are difficult fractures to treat. The surgeon is faced with the task of either attempting to fix the fracture if feasible or revise the resurfacing implant to a conventional total hip replacement. Method &
Results: Here we report of a novel way of fixing a peri-prosthetic fracture following
Introduction: Femoral neck failure due to avascular necrosis (AVN) is one of the most significant complications following
Correct positioning of the femoral component in
Aims: To compare the results of
Introduction: The Resurfacing Hip has been increasingly popular for younger patients. Femoral neck fractures are still the main complication. The problems associated with cement such as thermal necrosis, cement debris and lack of long-term biological fixation, combined with the general use of cementless fixation in young patients invite the question whether a cementless component can be used for
We examined the relationships between the serum levels of chromium and cobalt ions and the inclination angle of the acetabular component and the level of activity in 214 patients implanted with a metal-on-metal
Background. Hip arthroscopy is well established as a diagnostic and therapeutic tool in the native hip joint. However, its application in the symptomatic post-hip arthroplasty patient is still being explored. Aims and Methods. We have described the use of hip arthroscopy in symptomatic patients following total hip replacement,
Analysis of the different phases of the gait cycle has been shown to demonstrate differences in pathological osteoarthritic gait. These differences can be quantified and their improvement following total hip arthroplasty has been shown, allowing use of gait analysis as a tool in evaluating function after total hip replacements. The purpose of this study was to determine the degree of improvement in gait attained after
Aim: The purpose of the study was to compare the position of the femoral guide wire for during hip resurfacing, computer navigation and an alignment device. Materials and Methods: 26 cadaver specimens divided in 3 randomly selected groups and 25 patients were used to evaluate the position of the femoral guide wire in
Aims: To determine the pathological changes in the femur following
Background: Resurfacing hip replacement is becoming increasingly used surgical option for young active patients with disabling hip arthritis.However there is a paucity of published literature describing complications and their avoidance. Objective The objective of this study was to analyse 6 cases of postoperative subcapital fracture following hip resurfacing with a cohort of 54 cases that did not have a fracture and to identify factors associated with fractures risk. Materials and Methods Between January 1999 and October 2003, 60 hips in 54 patients were treated with metal on metal
Introduction and Aims: The use of
Seven psoas bursae filled with purulent fluid and inspissated debris were revealed at revision operations for failed
We report the outcome of total hip replacement in 29 failed metal-on-metal
This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip arthroplasty for aseptic loosening. We conducted a cohort study of first-time, single-stage revision hip arthroplasties (RHAs) performed for aseptic loosening and recorded in the National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man between 2003 and 2019. Patient identifiers were used to link records to national mortality data, and to NJR data to identify subsequent re-revision procedures. Multivariable Cox proportional hazard models with restricted cubic splines were used to define associations between volume and outcome.Aims
Methods
Background. Since the development of modern total hip replacement (THR) more than 50 years ago, thousands of devices have been developed in attempt to improve patient outcomes and prolong implant survival. Modern THR devices are often broadly classified according to their method of fixation; cemented, uncemented or hybrid (typically an uncemented acetabular component with a cemented stem). Due to early failures of THR in young active patients, the concept of hip resurfacing was revisited in the 1990's and numerous prostheses were developed to serve this patient cohort, some with excellent clinical results. Experience with metal-on-metal (MoM) bearing related issues particularly involving the ASR (DePuy Synthes, Warsaw, Indiana) precipitated a fall in the use of hip resurfacing (HR) prostheses in Australia from a peak of 30.2% in 2004 to 4.3% in 2015. The effects of poorly performing prostheses and what is now recognised as suboptimal patient selection are reflected in the AOANJRR cumulative percent revision (CPR) data which demonstrates 13.2% revision at 15 years for all
Aims. In metal-on-metal (MoM)
The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Australian National Joint Registry reported an inverse relationship between the size of the head component and the risk of revision in
The metal on metal implants was introduced without the proper stepwise introduction. The ASR