Advertisement for orthosearch.org.uk
Results 1 - 20 of 99
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 236 - 236
1 Sep 2012
Roche J Joss B DeSteiger R Miller L Nivbrant B Wood D
Full Access

There is ongoing debate on the benefits of fixed versus mobile bearing Unicompartmental Knee Replacement (UKR). We report the results from a randomised controlled trial comparing fixed and mobile bearing of the same UKR prosthesis. Forty patients were randomized to receive identical femoral components and either a fixed or mobile bearing tibial component. At 6.5 years follow-up 37% of the mobile bearing design had been revised and 14% for the fixed bearing design. The main reasons for revision were pain and loosening. These results were compared with data from The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) that show a cumulative percent revision of 24.2% for the mobile bearing Preservation UKR at 6.5 years. All locally explanted mobile bearings were examined microscopically, and 83% demonstrated significant backside wear. Constraint on the undersurface of the bearing coupled with a congruent upper surface may have contributed to the excessive revision rate. This is the first randomised controlled trial examining mobile and fixed variations of the same UKR prosthesis and shows this design of UKR with the mobile bearing has an unacceptably high revision rate and patients with this knee design should be closely monitored


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 397 - 402
1 Apr 2001
Freedman KB Back S Bernstein J

We reviewed all 717 manuscripts published in the 1997 issues of the British and American volumes of the Journal of Bone and Joint Surgery and in Clinical Orthopaedics and Related Research, from which 33 randomised, controlled trials were identified. The results and sample sizes were used to calculate the statistical power of the study to distinguish small (0.2 of standard deviation), medium (0.5 of standard deviation), and large (0.8 of standard deviation) effect sizes. Of the 33 manuscripts analysed, only three studies (9%) described calculations of sample size. To perform post-hoc power assessments and estimations of deficiencies of sample size, the standard effect sizes of Cohen (small, medium and large) were calculated. Of the 25 studies which reported negative results, none had adequate power (β < 0.2) to detect a small effect size and 12 (48%) lacked the power necessary to detect a large effect size. Of the 25 studies which did not have an adequate size of sample to detect small differences, the average used was only 10% of the required number. Our findings suggest that randomised, controlled trials in clinical orthopaedic research utilise sample sizes which are too small to ensure statistical significance for what may be clinically important results


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 69 - 69
1 Jan 2013
Hanusch B Gregg P Hui A
Full Access

Introduction. High flexion knee arthroplasties have been designed to allow up to 155 degrees flexion and enable high flexion activities such as kneeling and squatting. To date randomised controlled trials have shown no difference in range of movement (ROM) between high flexion and standard designs. Objectives. The aim of this study was to determine if there is a difference in functional outcome and ROM between the standard and high flexion design of the PFC Sigma TKA system. Methods. 84 patients with the diagnosis of osteoarthritis undergoing primary total knee arthroplasty were randomised to receive either a PFC Sigma or PFC Sigma RP-F total knee arthroplasty. ROM, Oxford Knee Score, Knee Society Score, Patella score and SF-12v2 were assessed independently before and at one year after surgery. Patients were blinded to the implant they received. Results. 42 patients in each group were included in this study and underwent surgery. 77 patients (92%) completed their one-year follow-up. There was no statistically significant difference in preoperative scores between groups. At one year there was a statistically significant difference in ROM between the groups with a mean of 105 degrees in the PFC Sigma and 114 degrees in the PFC Sigma RP-F group (p=0.01). There was also a statistically significant difference in flexion with 106 degrees and 115 degrees respectively (p=0.007). The difference in improvement in ROM and flexion was also statistically significant between the groups (p=0.009 and p=0.008). There was no statistically significant difference in any of the functional outcome scores. Conclusions. This is the first randomised controlled trial to show a statistically significant difference in ROM and flexion between a standard and a high flexion design TKA. Further follow-up will be carried out to determine if these differences persist over time and to evaluate the long-term survival of the different designs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 72 - 72
1 Jan 2013
Hamilton D Gaston P Patton S Burnett R Howie C Simpson H
Full Access

Introduction. Many prosthetic design changes have been introduced in attempt to improve outcomes following TKA; however there is no consensus as to whether these changes confer benefits to patients. This study aimed to assess whether patients treated with a modern implant design had an enhanced patient outcome compared to a traditional model in a double blind randomised controlled trial. Methods. 212 consecutive patients were prospectively randomised to receive either a modern (Triathlon) or a traditional (Kinemax) TKA (both Stryker Orthopaedics). 6 surgeons at a single unit performed all procedures in a standardised manner. A single researcher, blinded to implant allocation, performed all assessments. Patients were assessed pre-operatively, and at 6, 26, 52 weeks post-surgery with the Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, goniometry, timed functional assessment, lower limb power (Leg Extensor Power Rig) and pain numerical rating scales (NRS). Change in scores and between group differences were assessed with Two-Way Repeated Measures ANOVAs. Results. Both groups benefited from TKA demonstrating significant improvement in all parameters (p = < 0.001 in all cases). Significant interaction of the implant was observed in 1 year change score of OKS (F = 4.28, p = 0.04), knee flexion (F = 8.42, p = 0.004), lower limb power output (F = 11.33, p = 0.001) and maximal pain report (F = 7.44, p = 0.001), the modern implant superior in each case. Larger change scores were observed in WOMAC and timed functional assessments, but were not statistically significant. Conclusions. In a large prospective double blind randomised controlled trial, patients receiving a modern implant design demonstrated a significantly enhanced patient outcome in terms of knee range of motion, lower limb power output, reduced maximal pain report, and a clinically meaningful reduction in the OKS compared to a traditional design


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 67 - 67
1 Jan 2013
Liddle A Pandit H Jenkins C Price A Gill H Dodd C Murray D
Full Access

Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A randomised controlled trial was established with 63 knees (62 patients) randomised to either cemented (32 patients) or cementless UKR (30 patients). Fixation was assessed with fluoroscopic radiographs aligned to the bone-implant interface at one and five years. Outcome scores were collected pre-operatively and at one, two and five years, including Oxford Knee Score (OKS), American Knee Society Score, objective and functional (AKSS-O/F) and Tegner Activity Scale (TAS), expressed as absolute scores and 0–5 year change (δ) scores. Four patients died during the study period. There were no revisions. Mean operative time was 11 minutes shorter in the cementless group (p=0.029). At five years, there was no significant difference in any outcome measure except AKSS-F and δAKSS-F which were significantly better in the cementless group (both p=0.003). There were no femoral radiolucencies in either group. There were significantly more tibial radiolucencies in the cemented group (20/30 vs 2/27, p< 0.001). There were nine complete radiolucencies in the cemented group and none in the cementless group (p< 0.001). Cementless fixation provides improved fixation at five years compared to cemented fixation in UKR, maintaining equivalent or superior clinical outcomes with a shorter operative time and no increase in complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 245 - 245
1 Sep 2012
Khan L Will E Keating J
Full Access

Introduction

The aims of this study were to undertake a prospective randomised trial to compare functional outcome, strength and range of motion after treatment of medial collateral ligament injuries by either early unprotected mobilisation or mobilisation with a hinged brace.

Methods

Patients were randomised into either unprotected mobilisation or mobilisation with a hinged brace. Assessments occurred at 2 weeks, 6 weeks, 3 months and 6 months. Outcome measures included validated questionnaires (International Knee Documentation Committee and Knee Injury and Osteoarthritis Outcome Score scores), range of motion measurements and strength testing.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 91 - 91
1 Sep 2012
Raman R Singh J Johnson G Sharma H Day N Shaw C
Full Access

Introduction

Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20.

Methods

Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID's for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 78 - 78
1 Sep 2012
McKay G Harvie P Sloan K Beaver R
Full Access

We report our five-year functional results comparing navigated and conventional total knee replacement. To our knowlege this represents the first Level 1 study comparing function in navigated and conventional total knee replacement at five years.

An origianl cohort of 71 patients undergoing Duracon (Stryker Orthopaedics, St. Leonards, Australia) total knee replacement without patellar resurfacing were prospectively randomised to undergo operation using computer navigation (Stryker Image Free Computer Navigation System (version 1.0; Stryker Orthopaedics))(n=35) or a jig-based method (n=36). The two groups were matched for age, gender, height, weight, BMI, ASA grade abd pre-operative deformity. All operations were performed by a single surgeon. Reviews were undertaken by senior physiotherpist blinded to participant status using validated outcome scoring tools (Knee Society Score, WOMAC Score and Short Form SF-36 Score). All patients underwent CT scanning of the implanted prosthesis as per Perth CT Knee Protocol to assess component alignment.

After 5 years 24 patients in the navigated group and 22 patients in the conventional group were available for review. At 5 years no statistically significant difference was seen in any of the aforementioned outcome scores when comparing navigated and conventional groups. No statistically significant differencewas seen between 2- and 5-year results for either group.

Due to the relatively low numbers in each group these data were compared with retrospective cohorts of navigated (n=100) and conventional (n=70) Duracon total knee replacements performed outwith this study over the same 5-year period. WITHIN the retrospective cohorts no statistically significant differences were found when comparing any of the aforementioned outcome scores. In addition, when comparing parallel scores between prospective and retrospective groups again no statistically significant differences were identified.

At 5-years post-operatively the functional outcome between computer navigated and conventional total knee replacement appears to be no different despite the better alignment achieved using navigation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 27 - 27
1 Sep 2012
Dawson-Bowling S Yeoh D Edwards H East D Ellens N Miles K Butler-Manuel P Apthorp H
Full Access

Introduction

Debate continues regarding the relative advantages of ceramic-on-ceramic (CoC) and metal-on-polyethylene (MoP) articulations in total hip arthroplasty (THA). Perceived benefits of CoC include longevity, and low wear - in turn limiting the effects of particulate wear debris. However, CoC bearings cost significantly more, and concern remains over the risk of ceramic fracture; a complication not seen with MoP bearings, which are also cheaper.

Method

We electronically randomised 268 consecutive patients undergoing THA to receive either a CoC or MoP articulation. Patients aged over 72 were excluded. In all patients the prosthesis used was an uncemented ABG II (Stryker, USA), implanted by one of the two senior authors (HDA, ABM). Patients were scored preoperatively, and at annual follow-up clinics, using SF36, Visual Analogue (VAS), Merle d'Aubigné (MD) and Oxford Hip (OHS) Scores. Satisfaction levels were also documented.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 71 - 71
1 Sep 2012
Hanratty B Thompson N Bennett D Robinson A Mullan C Beverland D
Full Access

Increasing knee flexion following total knee arthroplasty (TKA) has become an important outcome measure. Surgical technique is one factor that can influence knee motion. In this study, it was hypothesised that stripping of the posterior knee capsule could improve flexion and range of motion (ROM) following TKA. Patients who were undergoing TKA were prospectively randomised into two groups - one group (62 patients) were allocated stripping of the posterior knee capsule (PCS), the other group (66 patients) no stripping (no-PCS). The primary outcome was change in flexion and ROM compared to pre-operative measurements at three time points; after wound closure, 3months and 1year post-operatively. Secondary outcomes were absolute measurements of flexion, extension, ROM and complications. All operations were performed by a single surgeon using the same implant and technique. All patients received identical post-operative rehabilitation. There was a significant gain in flexion after wound closure in the PCS group (p=0.022), however there was no significant difference at 3months or 1year post-operatively. Absolute values of extension (p=0.008) and flexion (p=0.001) 3months post-operatively were significantly reduced for the PCS group. The absolute value of ROM was significantly higher for the no-PCS group at 3months (p=0.0002) and 1year (p=0.005). There were no significant difference in the rate of complications. Posterior capsular stripping causes a transient increase in flexion that does not persist post-operatively. We do not recommend routine stripping of the posterior knee capsule in patients undergoing TKA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 36 - 36
23 Feb 2023
Ma N Gogos S Moaveni A
Full Access

Surgical site infections following orthopaedic surgery are a serious complication associated with increased morbidity and mortality. Intra-wound antibiotic powder may be able to provide infection prophylaxis locally with less systemic adverse effects, and promising results have been reported in systematic reviews of its use in spine surgery. This study aims to analyse the efficacy and adverse effect profile of intra-wound antibiotics in reducing surgical site infections in orthopaedic surgery for traumatic pelvic and lower limb fractures. A systematic review was conducted for studies reporting on the incidence of surgical site infections following administration of intra-wound antibiotic powder in pelvic and lower limb trauma surgery. Randomised controlled trials, cohort and case-control studies were included. A meta-analysis was conducted for deep surgical site infections. Seven studies were included in the systematic review including six retrospective case-control studies and one randomised controlled trial. Results of the meta-analysis suggest a potential 23% reduction in the odds of developing a deep surgical site infection in patients treated with intra-operative antibiotic powder compared with those managed with intravenous antibiotics alone (OR 0.77, 95% CI 0.52 – 1.13), although the results did not reach statistical significance. Notable selective bias against intra-wound antibiotics and suboptimal study design were found in the retrospective studies, however the randomised controlled trial reported a significant reduction in deep surgical site infections with intra-wound vancomycin powder. There were no reports of systemic adverse outcomes and minimal risk of wound complications with the use of intra-wound antibiotics. This review suggests the use of intra-wound antibiotic powder in pelvic and lower limb trauma surgery may reduce the incidence of deep surgical site infections. Further powered studies including randomised controlled trials are required to confirm the results highlighted in this study


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 23 - 23
10 May 2024
Leary J Lynskey T Muller A
Full Access

Objective. Carpal tunnel release surgery is a commonly performed procedure for alleviating symptoms of median nerve compression and restoring hand function. With pressure on theatre time these procedures are now commonly performed in a step-down out-patient facility under local anaesthetic. The choice of suture for skin closure in this procedure can impact the quality of wound healing, patient outcomes and the follow-up required however the question of the best type of suture remains unanswered. The purpose of this study was to compare the outcomes of absorbable and non-absorbable sutures using a randomised control trial design. Methods. Eighty patients diagnosed with bilateral carpal tunnel syndrome were enrolled and underwent outpatient carpal tunnel release surgery under local anaesthetic in a staged fashion. Random number generation was used to assign each hand to receive interrupted nylon or Vicryl Rapide sutures. Pre-operative data collection included patient demographics, ASA, inflammatory conditions, smoking status as well as a Boston Carpal Tunnel Questionnaire (BCTQ) for each hand. Patients were followed up at 2 and 6 weeks after each operation and the BCTQ was repeated along with the Patient and Observer Scar Assessment Scale and the VAS score for wound discomfort. This study has approval from the DHB ethics committee, Local Iwi, HDC and ANZ Clinical Trials:ACTRN12623000100695. Results. Statistical analysis assessed patient preference and the scores between the groups. Multi-variate analysis was performed to assess the factors that may be contributing to patient choice. Conclusion. Insights into patient preference and clinical outcomes associated with absorbable sutures and non-absorbable sutures in the setting of out-patient surgery are discussed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 69 - 69
10 Feb 2023
Tong Y Holmes S Sefton1 A
Full Access

There is conjecture on the optimal timing to administer bisphosphonate therapy following operative fixation of low- trauma hip fractures. Factors include recommendations for early opportunistic commencement of osteoporosis treatment, and clinician concern regarding the effect of bisphosphonates on fracture healing. We performed a systematic review and meta-analysis to determine if early administration of bisphosphonate therapy within the first month post-operatively following proximal femur fracture fixation is associated with delay in fracture healing or rates of delayed or non-union. We included randomised controlled trials examining fracture healing and union rates in adults with proximal femoral fractures undergoing osteosynthesis fixation methods and administered bisphosphonates within one month of operation with a control group. Data was pooled in meta-analyses where possible. The Cochrane Risk of Bias Tool and the GRADE approach were used to assess validity. For the outcome of time to fracture union, meta-analysis of three studies (n= 233) found evidence for earlier average time to union for patients receiving early bisphosphonate intervention (MD = −1.06 weeks, 95% CI −2.01 – −0.12, I. 2. = 8%). There was no evidence from two included studies comprising 718 patients of any difference in rates of delayed union (RR 0.61, 95% CI 0.25–1.46). Meta-analyses did not demonstrate a difference in outcomes of mortality, function, or pain. We provide low-level evidence that there is no reduction in time to healing or delay in bony union for patients receiving bisphosphonates within one month of proximal femur fixation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 96 - 96
10 Feb 2023
Blundell J Hope M
Full Access

Patients awaiting resolution of swelling and oedema prior to ankle surgery can represent a significant burden on hospital beds. Our study assessed whether external pneumatic intermittent compression (EPIC) can reduce delays to surgery. Our prospective randomised controlled trial (n= 20) compared outcomes of patients treated with EPIC vs control group managed with ice and elevation. Included were patients aged <18 years with isolated closed ankle fractures admitted for management of swelling prior to surgery. Excluded were open fractures, injuries to contralateral leg, diabetes, absent pulses, peripheral vascular disease, inability to consent, no requirement for admission. Eligible patients were randomised to active or control arms. All patients were managed initially with reduction and back slab application. Patients in active arm fitted with EPIC (Hydroven 3000) device over the back slab. Assessment by treating team determined the time at which patient is assessed ready for surgery. Patients in the treatment arm were assessed as ready for surgery sooner, (123 hrs vs 168hrs, T score = 1.925, P 0.035) and had a shorter time to surgery (167 hrs vs 216 hrs, T score = 1.748, P 0.047) Length of stay was reduced bud did not reach statistical significance. (259 hrs vs 269 hrs, T score 0.229, P 0.41). Our results showed a statistically and clinically significant reduction in time that patients were assessed ready for surgery and time to surgery in the treatment cohort. We conclude that although further data is needed to achieve an adequately powered study and assess the safety profile of the EPIC, incorporation of EPIC into routine clinical practice has the potential for significant cost savings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 82 - 82
23 Feb 2023
Rossignol SL Boekel P Rikard-Bell M Grant A Brandon B Doma K O'Callaghan W Wilkinson M Morse L
Full Access

Glenoid baseplate positioning for reverse total shoulder replacements (rTSR) is key for stability and longevity. 3D planning and image-derived instrumentation (IDI) are techniques for improving implant placement accuracy. This is a single-blinded randomised controlled trial comparing 3D planning with IDI jigs versus 3D planning with conventional instrumentation. Eligible patients were enrolled and had 3D pre-operative planning. They were randomised to either IDI or conventional instrumentation; then underwent their rTSR. 6 weeks post operatively, a CT scan was performed and blinded assessors measured the accuracy of glenoid baseplate position relative to the pre-operative plan. 47 patients were included: 24 with IDI and 23 with conventional instrumentation. The IDI group were more likely to have a guidewire placement within 2mm of the preoperative plan in the superior/inferior plane when compared to the conventional group (p=0.01). The IDI group had a smaller degree of error when the native glenoid retroversion was >10° (p=0.047) when compared to the conventional group. All other parameters (inclination, anterior/posterior plane, glenoids with retroversion <10°) showed no significant difference between the two groups. Both IDI and conventional methods for rTSA placement are very accurate. However, IDI is more accurate for complex glenoid morphology and placement in the superior-inferior plane. Clinically, these two parameters are important and may prevent long term complications of scapular notching or glenoid baseplate loosening. Image-derived instrumentation (IDI) is significantly more accurate in glenoid component placement in the superior/inferior plane compared to conventional instrumentation when using 3D pre-operative planning. Additionally, in complex glenoid morphologies where the native retroversion is >10°, IDI has improved accuracy in glenoid placement compared to conventional instrumentation. IDI is an accurate method for glenoid guidewire and component placement in rTSA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 29 - 29
1 Dec 2022
Alolabi B Shanthanna H Czuczman M Moisiuk P O'Hare T Khan M Forero M Davis K Moro JK Foster G Thabane L
Full Access

Interscalene brachial plexus block is the standard regional analgesic technique for shoulder surgery. Given its adverse effects, alternative techniques have been explored. Reports suggest that the erector spinae plane block may potentially provide effective analgesia following shoulder surgery. However, its analgesic efficacy for shoulder surgery compared with placebo or local anaesthetic infiltration has never been established. We conducted a randomised controlled trial to compare the analgesic efficacy of pre-operative T2 erector spinae plane block with peri-articular infiltration at the end of surgery. Sixty-two patients undergoing arthroscopic shoulder repair were randomly assigned to receive active erector spinae plane block with saline peri-articular injection (n = 31) or active peri-articular injection with saline erector spinae plane block (n = 31) in a blinded double-dummy design. Primary outcome was resting pain score in recovery. Secondary outcomes included pain scores with movement; opioid use; patient satisfaction; adverse effects in hospital; and outcomes at 24 h and 1 month. There was no difference in pain scores in recovery, with a median difference (95%CI) of 0.6 (-1.9-3.1), p = 0.65. Median postoperative oral morphine equivalent utilisation was significantly higher in the erector spinae plane group (21 mg vs. 12 mg; p = 0.028). Itching was observed in 10% of patients who received erector spinae plane block and there was no difference in the incidence of significant nausea and vomiting. Patient satisfaction scores, and pain scores and opioid use at 24 h were similar. At 1 month, six (peri-articular injection) and eight (erector spinae plane block) patients reported persistent pain. Erector spinae plane block was not superior to peri-articular injection for arthroscopic shoulder surgery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 81 - 81
10 Feb 2023
Kioa G Hunter S Blackett J
Full Access

Routine post-operative bloods following all elective arthroplasty may be unnecessary. This retrospective cohort study aims to define the proportion of post-operative tests altering clinical management. Clinical coding identified all elective hip or knee joint replacement under Hawkes Bay District Health Board contract between September 2019-December 2020 (N=373). Uni-compartmental and bilateral replacements, procedures performed for cancer, and those with insufficient data were excluded. Demographics, perioperative technique, and medical complication data was collected. Pre- and post-operative blood tests were assessed. Outcome measures included clinical intervention for abnormal post-operative sodium (Na), creatinine (Cr), haemoglobin (Hb), or potassium (K) levels. A cost-benefit analysis assessed unnecessary testing. 350 patients were Included. Median age was 71 (range 34-92), with 46.9% male. Only 26 abnormal post-operative results required intervention (7.1%). 11 interventions were for low Na, 4 for low K, and 4 for elevated Cr. Only 7 patients were transfused blood products. Older age (p=0.009) and higher ASA (p=0.02) were associated with intervention of any kind. Abnormal preoperative results significantly predicted intervention for Na (p<0.05) and Cr (p<0.05). All patients requiring treatment for K used diuretic medication. Preoperative Hb level was not associated with need for transfusion. Overall, there were 1027 unnecessary investigations resulting in $18,307 excess expenditure. Our study identified that the majority of elective arthroplasty patients do not require routine postoperative blood testing. We recommend investigations for patients with preoperative electrolyte abnormality, those taking diuretics, and patients with significant blood loss noted intra-operatively. In future, a larger, randomised controlled trial would be useful to confirm these factors


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 49 - 49
10 Feb 2023
Erian C Erian M Ektas N Scholes C Bell C
Full Access

Anterior cruciate ligament (ACL) ruptures are debilitating injuries, often managed via ACL reconstruction (ACLR). Reduced range of motion (ROM), particularly loss of extension (LOE), is the most significant contributor to post-operative patient dissatisfaction. LOE may preclude return to sport, increase re-rupture rates and precipitate osteoarthritis. Passive LOE rates following ACLR have been reported at 15%. However, LOE incidence during active tasks are poorly characterised. Our review sought to determine knee extension angles for active tasks following an ACL injury or ACLR. We hypothesised greater incidences of active LOE following ACL injury or ACLR, compared to uninjured contralateral limbs or controls. We systematically searched MEDLINE, Embase, Cochrane Library, Scopus, SPORTDiscus, and relevant trials databases for English articles. Included were cohort, cross-sectional, case-controlled or randomised controlled trials analysing adults with ACL injury treated surgically or otherwise, with at least 12-weeks follow-up and reporting either active knee extension angle, active LOE angles or incidence of active knee LOE during functional tasks. The protocol was registered on PROSPERO (CRD42018092295). Subsequent meta-analysis was performed. After screening, 71 eligible articles were included. Studies were heterogenous in design and quality. Included tasks were overground walking (n=44), running (n=3), hopping/jumping/cutting (n=11) single-leg landing (n=7), and stair climbing (n=6). LOE incidence varied depending on functional activities (33.95-92.74%). LOE incidence did not vary depending on ACL status (67.26% vs. 65.90% vs. 62.57% for ACL intact, ACLD and ACLR, respectively). We observed no difference in active LOE incidence according to ACL status. Importantly, the observed incidence for active LOE was reliably higher than previously reported rates for passive measures. Given the discrepancy between active and passive LOE incidence, clinicians may advisably prioritise active ROM during ACL rehabilitation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 118 - 118
23 Feb 2023
Zhou Y Dowsey M Spelman T Choong P Schilling C
Full Access

Approximately 20% of patients feel unsatisfied 12 months after primary total knee arthroplasty (TKA). Current predictive tools for TKA focus on the clinician as the intended user rather than the patient. The aim of this study is to develop a tool that can be used by patients without clinician assistance, to predict health-related quality of life (HRQoL) outcomes 12 months after total knee arthroplasty (TKA). All patients with primary TKAs for osteoarthritis between 2012 and 2019 at a tertiary institutional registry were analysed. The predictive outcome was improvement in Veterans-RAND 12 utility score at 12 months after surgery. Potential predictors included patient demographics, co-morbidities, and patient reported outcome scores at baseline. Logistic regression and three machine learning algorithms were used. Models were evaluated using both discrimination and calibration metrics. Predictive outcomes were categorised into deciles from 1 being the least likely to improve to 10 being the most likely to improve. 3703 eligible patients were included in the analysis. The logistic regression model performed the best in out-of-sample evaluation for both discrimination (AUC = 0.712) and calibration (gradient = 1.176, intercept = -0.116, Brier score = 0.201) metrics. Machine learning algorithms were not superior to logistic regression in any performance metric. Patients in the lowest decile (1) had a 29% probability for improvement and patients in the highest decile (10) had an 86% probability for improvement. Logistic regression outperformed machine learning algorithms in this study. The final model performed well enough with calibration metrics to accurately predict improvement after TKA using deciles. An ongoing randomised controlled trial (ACTRN12622000072718) is evaluating the effect of this tool on patient willingness for surgery. Full results of this trial are expected to be available by April 2023. A free-to-use online version of the tool is available at . smartchoice.org.au.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 25 - 25
23 Feb 2023
Marinova M Sundaram A Holtham K Ebert J Wysocki D Meyerkort D Radic R
Full Access

Cryocompression therapy is a non-invasive and non-pharmacological modality used in managing acute post-operative inflammation and pain. A prospective, randomised controlled trial (RCT) was undertaken to evaluate the effectiveness of a post-operative cryocompression protocol using the Game Ready™ (GR) device versus usual care on recovery following total knee arthroplasty (TKA). A single centre RCT was conducted with 70 TKAs (68 patients) randomised to a 2-week intervention period consisting of treatment with GR cryocompression (n=33, 33.3% males) or a usual care protocol of ice with static compression using tubigrip (n=35, 54.3% males). Knee range of movement (ROM) (flexion and extension), a visual analogue pain score (VAS) and limb circumference were documented at day 1, 2 and 14, as well as 6 and 12 weeks post-surgery. ROM was also recorded at day 90, while medication use and length of hospital stay were documented. Patient reported outcome measures (PROMs) including the KOOS and patient satisfaction questionnaire were employed. The GR group demonstrated 2.3° more (p=0.05) knee extension ROM overall, as well as 2. 8° more at day 1 (p=0.048), 3.8° at day 14 (p=0.007) and 5.4° at 3 months (p=0.017). There were no group differences (p>0.05) observed in pain (VAS), flexion ROM, limb circumference, opioid use or other PROMs. Across the full cohort, higher pain levels resulted in increased opioid intake (p=0.002), older patients used significantly less opioids (p<0.001) and males reported significantly less pain (VAS) than females (p=0.048). Using GR following TKA is a safe, non-invasive tool that can be used to aid in the post-operative recovery period. Patients using the GR cryocompression device gained significantly more extension ROM compared to the conventional ice with compression group, despite no other group differences