Aim. Rifampicin and fluoroquinolone based therapy is generally considered as first-choice targeted oral antimicrobial therapy for staphylococcal prosthetic joint infections (PJI) treated with debridement, antibiotics and implant retention (DAIR). Alternative equally effective antimicrobial strategies are urgently needed due to toxicity and drug-drug interactions that frequently occur with this strategy. Data from recent clinical studies suggests equipoise for other antimicrobial treatment regimens. The objective of the Rifampicin Combination Therapy versus Targeted Antimicrobial Monotherapy in the Oral Antimicrobial Treatment Phase of Staphylococcal Prosthetic Joint Infection (RiCOTTA)-trial is to evaluate whether monotherapy with clindamycin is non-inferior to rifampicin/fluoroquinolone combination therapy in patients with staphylococcal PJI that are treated with DAIR. Method. The RiCOTTA-trial is a multicenter, non-inferiority, open-label, randomized controlled trial evaluating clindamycin versus rifampicin/fluoroquinolone combination therapy in the oral treatment phase in patients with staphylococcal PJI managed with DAIR. The trial is performed in 16 hospitals in the Netherlands. Eligible patients are adults with staphylococcal knee or hip PJI managed by DAIR. Patients are included one to six days before antibiotic treatment is switched from intravenous to oral therapy. Patients with a contraindication for rifampicin, with a megaprosthesis or who receive intravenous antibiotics for more than three weeks after initial debridement are excluded. Primary outcome is treatment success one year after finishing antimicrobial treatment. Success is defined as the absence of: i. Infection related re-surgery, ii. New episode of antibiotic treatment for infection of the index joint after the initial treatment phase of 12 weeks, iii. Ongoing use of antibiotics for the index joint at the end of follow-up, iv. Death. The estimated treatment success of rifampicin combination therapy is 85% and the monotherapy strategy is considered not inferior when the difference in treatment success will be less than 10%. Enrolment of 158 patients per group (316 in total) is needed to confirm non-inferiority of monotherapy with a power of 80%. The trial is currently open for enrolment. The study is approved by the Medical Ethics Committee Leiden, the Hague, Delft, the Netherlands and registered under EU trial number 2022-501620-26-00 in Clinical Trial Information System. Conclusions. Currently, the RiCOTTTA study is the largest
There has been ongoing debate for many years on the relative merits of routine tourniquet use while performing a total knee replacement. Interestingly there have been many retrospective reviews and opinion articles on the topic, but little in the way of well powered prospective
There has been ongoing debate for many years on the relative merits of routine tourniquet use while performing a total knee replacement. Interestingly there have been many retrospective reviews and opinion articles on the topic, but little in the way of well powered prospective
Resurfacing the patella is performed the majority of the time in the United States and in many regions it is considered standard practice. In many countries, however, the patella is left un-resurfaced an equal amount of the time or even rarely ever resurfaced. Patella resurfacing is not a simple or benign procedure. There are numerous negative sequelae of resurfacing including loosening, fragmentation, avascular necrosis, lateral facet pain, stress fracture, acute fracture, late fracture, and restricted motion. In a study by Berend, Ritter, et al, failures of the patella component were reported 4.2% of the time at an average of only 2.6 years. A study was undertaken at Washington University in recent years to determine rather more clinical problems were observed following total knee replacement with or without patella resurfacing. Records were maintained on all problem total knees cases with well localised anterior knee pain. The referral area for this clinic is St. Louis which is among the largest American cities, with the highest percentage of total knees that are performed without patella resurfacing. During 4 years of referrals of total knee patients with anterior knee pain, 47 cases were identified of which 36 had a resurfaced patella and 11 had a non-resurfaced patella. Eight of 36 resurfaced patellae underwent surgery while only 2 of 11 non-resurfaced patellae underwent subsequent surgery. More than 3 times as many painful total knees that were referred for evaluation had already had their patella resurfaced. In spite of the fact that approximately equal number of total knees were performed in this area without patella resurfacing, far more patients presented to clinic with painful total knee in which the patella had been resurfaced. The numerous pathologies requiring a treatment following patella resurfacing included patella loosening, fragmentation of the patella, avascular necrosis patella, late stress fracture, lateral facet pain, oblique resurfacing, and too thick of a patellar composite. In a large multi-center
Resurfacing the patella is performed the majority of the time in the US and in many regions it is considered standard practice. In many countries, however, the patella is left unresurfaced an equal amount of the time or even rarely ever resurfaced. Patella resurfacing is not a simple or benign procedure. There are numerous negative sequelae of resurfacing including loosening, fragmentation, avascular necrosis, lateral facet pain, stress fracture, acute fracture, late fracture, and restricted motion. In a study by Berend, Ritter, et al, failures of the patella component were reported 4.2% of the time at an average of only 2.6 years. A study was undertaken at Washington University in recent years to determine whether more clinical problems were observed following total knee replacement with or without patella resurfacing. Records were maintained on all problem total knees cases with well localised anterior knee pain. The referral area for this clinic is St. Louis which is among the largest American cities, with the highest percentage of total knees that are performed without patella resurfacing. During 4 years of referrals of total knee patients with anterior knee pain, 47 cases were identified of which 36 had a resurfaced patella and 11 had a non-resurfaced patella. Eight of 36 resurfaced patellae underwent surgery while only 2 of 11 non-resurfaced patellae underwent subsequent surgery. More than 3 times as many painful total knees that were referred for evaluation had already had their patella resurfaced. In spite of the fact that approximately equal number of total knees were performed in this area without patella resurfacing, far more patients presented to clinic with painful total knee in which the patella had been resurfaced. The numerous pathologies requiring a treatment following patella resurfacing included patella loosening, fragmentation of the patella, avascular necrosis patella, late stress fracture, lateral facet pain, oblique resurfacing, and too thick of a patellar composite. In a large multi-center
Durable humeral component fixation in shoulder arthroplasty is necessary to prevent painful aseptic loosening and resultant humeral bone loss. Causes of humeral component loosening include stem design and material, stem length and geometry, ingrowth vs. ongrowth surfaces, quality of bone available for fixation, glenoid polyethylene debris osteolysis, exclusion of articular particulate debris, joint stability, rotator cuff function, and patient activity levels. Fixation of the humeral component may be achieved by cement fixation either partial or complete and press-fit fixation. During the past two decades, uncemented humeral fixation has become more popular, especially with short stems and stemless press fit designs. Cemented humeral component fixation risks difficult and complicated revision surgery, stress shielding of the tuberosities and humeral shaft periprosthetic fractures at the junction of the stiff cemented stem and the remaining humeral shaft. Press fit fixation may minimise these cemented risks but has potential for stem loosening. A
Over the past 30 years, cemented, cementless, and hybrid fixation options have been utilised with various total knee arthroplasty (TKA) implant systems. While cemented components are widely used and considered the most reliable method of fixation, historical results may not be applicable to contemporary patients, who are increasingly younger than 65 years of age. Moreover, the literature is not definitive on which method of TKA fixation obtains the best clinical, functional, and radiographic results. A recent Cochrane meta-analysis on roentgen stereophotogrammetric analysis (RSA) included five
Tranexamic acid (TXA) is an effective medication to limit blood loss and transfusion requirements in association with contemporary total joint arthroplasty. TXA is in a class of medications termed anti-fibrinolytics due to their action to limit the breakdown of clot that has already been formed. It is useful to note that TXA does not promote the formation of clot, it simply limits the breakdown of already established clot. A recent systematic review and meta-analysis of
Total hip arthroplasty (THA) has been cited as one of the most successful surgical procedures performed today. However, as hip surgeons, we desire constantly improving outcomes for THA patients with more favorable complication rates. At the same time, patients desire hip pain relief and return to function with as little interruption of life as possible. The expectation of patients has changed; they have more physical demands for strength and flexibility, and aspire to achieve more in their recreational pursuits. Additionally, health care system constraints require the THA episode of care to become more efficient as the number of procedures increases with time. These factors, over the past fifteen years, have led to a search for improved surgical approaches and peri-operative pain and rehabilitation protocols for primary THA. The orthopaedic community has seen improved pain control, length of stay, and reduction in complications with changes in practice and protocols. However, the choice of surgical approach has provided significant controversy in the orthopaedic literature. In the 2000s, the mini-posterior approach (MPA) was demonstrated as the superior tissue sparing approach. More recently, there has been a suggestion that the direct anterior approach (DAA) leads to less muscle damage, and improved functional outcomes. A recent prospective randomised trial has shown a number of early deficits of the posterior approach when compared to the direct anterior approach. The posterior approach resulted in patients taking an additional 5 days to discontinue a walker, discontinue all gait aids, discontinue narcotics, ascend stairs with a gait aid, and to walk 6 blocks. Patients receiving the posterior approach required more morphine equivalents in the hospital, and had higher VAS pain scores in the hospital than the direct anterior approach. Interestingly, activity monitoring at two weeks post-operatively also favored DAA with posterior approach patients walking 1600 steps less per day than DAA patients. There has been little difference in the radiographic outcomes or complications between approaches in prospective randomised trials. A number of
Over the past 30 years, cemented, cementless, and hybrid fixation options have been utilised with various total knee arthroplasty (TKA) implant systems. While cemented components are widely used and considered the most reliable method of fixation, historical results may not be applicable to contemporary patients, who are increasingly younger than 65 years of age. Moreover, the literature is not definitive on which method of TKA fixation obtains the best clinical, functional, and radiographic results. A recent Cochrane meta-analysis on roentgen stereophotogrammetric analysis (RSA) included five
Bearing surfaces in Total Hip Arthroplasty (THA) may affect implant longevity and hence patient outcomes. This
Tranexamic acid (TXA) is an effective medication to limit blood loss and transfusion requirements in association with contemporary total joint arthroplasty. TXA is in a class of medications termed anti-fibrinolytics due to their action to limit the breakdown of a clot that has already been formed. It is useful to note that TXA does not promote the formation of a clot, it simply limits the breakdown of already established clots. A recent systematic review and meta-analysis of
In recent years, cementless stems have dominated the North American market. There are several categories of cementless stems, but in the past 20 years, the two most popular designs in the United States have been the extensively coated cylindrical cobalt-chrome (CoCr) stem and the proximally coated tapered titanium stem, which in recent years has become the most common. The 10-year survival for both stem types has been over 95% with a distinction made on factors other than stem survival, including thigh pain, stress shielding, complications of insertion, and ease of revision. Conventional wisdom holds that proximally coated titanium stems have less stress shielding, less thigh pain, and a higher quality clinical result. Recent studies, however, including
For 3 decades surgeons have vigorously debated whether it is reasonable to offer simultaneous bilateral total knee replacement (TKA) to patients. Even after this substantial period of time there remain no
Any arthroplasty that offers superior function needs to be assessed using metrics that are capable of detecting those functions. The Oxford Hip Score (OHS), the Harris Hip Score (HHS) and WOMAC are patient reported outcome measures (PROMs) with well documented ceiling effects: following hip arthroplasty, many patients are clustered close to full marks following surgery. Two recent well conducted
Over the past 30 years, cemented, cementless, and hybrid fixation options have been utilised with various total knee arthroplasty (TKA) implant systems. While cemented components are widely used and considered the most reliable method of fixation, historical results may not be applicable to contemporary patients, who are increasingly younger than 65 years of age. Moreover, the literature is not definitive on which method of TKA fixation obtains the best clinical, functional, and radiographic results. A recent Cochrane meta-analysis on roentgen stereophotogrammetric analysis (RSA) included five
The Oxford Hip Score (OHS), the Harris Hip Score (HHS) and WOMAC are examples of patient reported outcome measures (PROMs) have well documented ceiling effects, with many patients clustered close to full marks following arthroplasty. Any arthroplasty that offers superior function would therefore fail to be detectable using these metrics. Two recent well conducted
Only a little over a decade ago the vast majority of primary total hip replacements performed in North America, and indeed globally, employed a conventional polyethylene insert, either in a modular version or in a cemented application. Beginning in the early 2000's there was an explosion in technology and options available for the bearing choice in total hip arthroplasty. Highly crosslinked polyethylene was introduced in 1998, and within a few short years the vast majority of polyethylene inserts performed in North America were manufactured from this material. Globally there was a mixed picture with variable market penetration. Surgeons had seen historically poor results with attempts at “improving” polyethylene in the past and many were hesitant to use this new technology. Many
Only a little over a decade ago the vast majority of primary total hip replacements performed in North America, and indeed globally, employed a conventional polyethylene insert, either in a modular version or in a cemented application. Beginning in the early 2000's there was an explosion in technology and options available for the bearing choice in total hip arthroplasty. Highly cross-linked polyethylene was introduced in 1998, and within a few short years the vast majority of polyethylene inserts performed in North America were manufactured from this material. Globally there was a mixed picture with variable market penetration. Surgeons had seen historically poor results with attempts at “improving” polyethylene in the past and many were hesitant to use this new technology. Many
In recent years, cementless stems have dominated the North American market. There are several categories of cementless stems, but in the past 20 years, the two most popular designs in the United States have been the extensively coated cylindrical cobalt-chrome (Co-Cr) stem and the proximally coated tapered titanium stem, which in recent years has become the most common. The 10-year survival for both stem types has been over 95% with a distinction made on factors other than stem survival, including thigh pain, stress shielding, complications of insertion, and ease of revision. Conventional wisdom holds that proximally coated titanium stems have less stress shielding, less thigh pain, and a higher quality clinical result. Recent studies, however, including