header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 2 - 2
1 Nov 2014
Harris N Hendricson A Rydholm U Knutson K Popelka S
Full Access

Introduction:. We present the early results of 220 Rebalance Total Ankle Replacements performed in 6 centres in 4 different countries. Methods:. The Rebalance Total Ankle Replacement is a new 3 component uncemented mobile bearing prosthesis with a surface coating of ‘bonemaster’ and an ‘e’ poly bearing. The prosthesis was released in a limited way in May 2011. Since then 220 replacements have been implanted in 218 patients in 6 centres in 4 different countries (UK, Sweden, Canada, Czech Republic). All the x-rays and case notes were reviewed.63 prostheses have a minimum follow up of 2 years. Outcome measures included revision of the prosthesis, and the incidence of progressive and non-progesssive radiolucent lines around the prosthesis. Results:. 7 patients underwent revision or are awaiting revision of their prosthesis. Reasons for revision included loosening(2), infection(1), malposition(2), periprosthetic fracture(1), impingement(1). 9 patients had non-progressive radiolucent lines and 2 patients had progressive radiolucent lines. 1 patient with progressive radiolucent lines is waiting revision for suspected infection. 8 patients suffered fractures to the lateral malleolus and 4 to the medial malleolus. There were no cases of balloon osteolysis. 29 patients had pre-op AOFAS scores= 41(12–67). 21 had 1 year post-op AOFAS scores= 73.5(26–100). 12 had 2 year AOFAS scores= 75.5(50–100). Conclusion:. The early results are encouraging and we believe support its wider use


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 17 - 17
16 May 2024
Batten T Talbot N Sharpe I
Full Access

Revision options for a failed Total ankle arthroplasty (TAA) have historically been limited to complex hindfoot fusions, bespoke ankle arthroplasty revision or amputation. The patient outcomes of these procedures has been felt to be poor. The introduction of the INBONE-II and INVISION ankle arthroplasty revision systems has created a range of revision arthroplasty options, with the possibility of improved patient outcomes. We aim to report on the early results of 20 sequential revision TAA. All patients undergoing revision TAA with INBONE-II or INVISION had prospective collection of pre-operative and post-operative MOx-FQ and EQ-5D scores. Between September 2013 and June 2019 23 patients underwent revision TAA with mean time from implantation of 35 months (6 to 74). Those with greater than 1 year follow-up had scores included. Other outcomes included radiographic assessment for loosening and revision. 13 patients had INBONE-II and 10 INVISION. None required revision at the time of review. Pre-operative MOx-FQ averaged 40.6 (13.4 pain, 21 walking, 6.2 social). Post-operative MOx-FQ averaged 17.4 (6.2 pain, 8.1 walking, 3.1 social). Average EQ-5D improved from 8 to 6.6 and average EQ-VAS from 60 to 80. On radiograph review one patient had radiolucent lines around their INBONE-II stem evident at 1 year. This had not progressed by 4 years total follow-up. Another patient had uncoupling of part of the stem of her INBONE-II but had not required revision. This was attributed to surgeon error. Revision TAA using the INBONE-II and INVISION systems shows promising early results relating to loosening and revision and good maintained improvement in MOx-FQ and EQ-5D scores. This provides further evidence that patients with a failed TAA can safely have revision rather than having to commit to complex ankle/hindfoot fusion. This provides surgeons with flexibility particularly in those patients with other hindfoot arthritis or arthrodesis


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 793 - 798
1 Jun 2012
Bianchi A Martinelli N Sartorelli E Malerba F

The Bologna–Oxford (BOX) total ankle replacement (TAR) was developed with the aim of achieving satisfactory pain-free movement of the ankle. To date, only one single multicentre study has reported its clinical results. The aim of this study was to conduct an independent review of its mid-term results.

We retrospectively reviewed a total of 60 prospectively followed patients in whom 62 BOX TARs had been implanted between 2004 and 2008. We used the American Orthopedic Foot and Ankle Society (AOFAS) score to assess the clinical results. Standardised radiographs taken at the time of final follow-up were analysed by two observers. The overall survival was 91.9% at a mean follow-up of 42.5 months (24 to 71). The mean AOFAS score had improved from 35.1 points (sd 16.6; 4 to 73) pre-operatively to 78.0 (sd 10.7; 57 to 100) at final follow-up (p < 0.01). Tibial radiolucencies < 2 mm in width were seen around 16 TARs. Talar radiolucencies < 2 mm were seen around four TARs. A total of 47 patients (78.3%) were very satisfied or satisfied with the outcome. Five patients required revision for functional limitation or continuing pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 907 - 914
1 Jul 2009
Koivu H Kohonen I Sipola E Alanen K Vahlberg T Tiusanen H

Between 2002 and 2008, 130 consecutive ankles were replaced with an hydroxyapatite (HA) and titanium-HA-coated Ankle Evolutive System total ankle prosthesis. Plain radiographs were analysed by two independent observers. Osteolytic lesions were classified by their size and location, with cavities > 10 mm in diameter considered to be ‘marked’. CT scanning was undertaken in all patients with marked osteolysis seen on the plain radiographs.

Osteolytic lesions were seen on the plain films in 48 (37%) and marked lesions in 27 (21%) ankles. The risk for osteolysis was found to be 3.1 (95% confidence interval 1.6 to 5.9) times higher with implants with Ti-HA porous coating.

Care should be taken with ankle arthroplasty until more is known about the reasons for these severe osteolyses.